Current Transformer Concepts| CT Burden | CT Accuracy Class
Vložit
- čas přidán 25. 06. 2024
- Current Transformer concepts, working principle, CT Burden, CT Accuracy Class and , CT polarity, CT ratio calculation are all very important topics that have been discussed in this video. Very well explained so don't skip any part in order to understand the concept of current transformer.
If you want this tutorial in power point, let me know in comment section please
#currenttransformer #ct #ctburden
Wow first time ct burden is explained in simpler manner
Too good. Wonderful explaination
Stunning well done
Perfect as usuall
Your way of explanation is awesome thank u ...keep more topics ..
Stay tuned and dont forget to subscribe plz
Nicely explained
Thanks stay tuned and dont forget to subscribe plz
This is an excellent tutorial, keep it up
Thanks. Stay tuned and dont forget to subscribe
Hi, I like your lecture. Thanks
Stay tuned and dont forget to subscribe plz
Outstanding way of teaching
good one. thank you.
Stay tuned and dont forget to subscribe plz
👍
Thanks a lot
Stay tuned and dont forget to subscribe
From which software u make this video
Thank you.
Thanks. Stay tuned and dont forget to subscribe plz
CT operating in normal mode then fault current appears in load ... how can we reduce fault current on primary side by effective changes on Secondary side... what are the changes possible on Secondary side to reduce fault current on primary side
Hi,if data markings on the CT's disappear how would one determine the correct ratio? Thank You.
Then you have to do it by hit and trial. One thing for sure the output is always 5. So by measuring secondary current and primary you can compute ratio
@@electricallectures so i basically run 100a through the line and measure Ct output amps. If its 2.5 its primary is 200a. But due to impedance and accuracy class, output can't be accurate right?
I have a question. Please could you tell me, what would happen if the flow primary current is 300 A permanently, and the ratio CT is only 200/5 A? Thanks by the answer.
Ct will saturate and 5 A will continue to flow
@@electricallectures Thanks a lot by the answer.
@@electricallectures I don't agree, please elaborate further. There are times when you can set the pick to be above the 100% rating, which is 5A. I have seen the CT's rated 600/5A and relay set at 1.2 of the primary current. Is that a wrong practice or what?
Absolutely wrong. Ct can only produce 5A. As far as pickup is concerned , 1.2 can be set if the maximum primary current is 600. Let say ur relay is supposed to trip @400A which is 1.2 times. Now ur ct is 600/5 and it will work in this situation
What happens on primary side current when burden increases on Secondary side
No effect on primary but if burden exveed the ratio will be disturbed and so as secondary current
If the Secondary winding is replaced with reactance instead of short circuit after sometime then what happens on primary side current
Sir could you please explain any practical application or uses of reduction of CTR...? It's will be much beneficial for me..Thanks in advance sir.. 🙏🙏🙏
Do you want to ask usage of CT . I dont actually understand your question. Reduction of ctr
200/2 farmola 😊
Don't understand
i cannot understand you bus or bar type?? wtf