Current Transformer Concepts| CT Burden | CT Accuracy Class

Sdílet
Vložit
  • čas přidán 25. 06. 2024
  • Current Transformer concepts, working principle, CT Burden, CT Accuracy Class and , CT polarity, CT ratio calculation are all very important topics that have been discussed in this video. Very well explained so don't skip any part in order to understand the concept of current transformer.
    If you want this tutorial in power point, let me know in comment section please
    #currenttransformer #ct #ctburden

Komentáře • 38

  • @amazingvideos673
    @amazingvideos673 Před 3 lety +4

    Wow first time ct burden is explained in simpler manner

  • @asmafarid2939
    @asmafarid2939 Před 3 lety +2

    Too good. Wonderful explaination

  • @hfaArt
    @hfaArt Před 3 lety +2

    Stunning well done

  • @wakh6260
    @wakh6260 Před 3 lety

    Perfect as usuall

  • @nuthalapatisudhakararao3515

    Your way of explanation is awesome thank u ...keep more topics ..

  • @sanjayhake6872
    @sanjayhake6872 Před 8 měsíci +1

    Nicely explained

  • @macpeleanyanwu745
    @macpeleanyanwu745 Před rokem +1

    This is an excellent tutorial, keep it up

  • @sohailjanjua123
    @sohailjanjua123 Před 2 lety +2

    Hi, I like your lecture. Thanks

  • @amazingvideos673
    @amazingvideos673 Před 3 lety +1

    Outstanding way of teaching

  • @manojillangasooriya3590
    @manojillangasooriya3590 Před 6 měsíci

    good one. thank you.

  • @abidkayani336
    @abidkayani336 Před 3 lety

    👍

  • @yibeltalassefa3619
    @yibeltalassefa3619 Před 2 lety

    Thanks a lot

  • @edupros9028
    @edupros9028 Před 3 lety

    From which software u make this video

  • @sushilkoch8625
    @sushilkoch8625 Před 7 měsíci

    Thank you.

  • @suryasreedharreddy2277

    CT operating in normal mode then fault current appears in load ... how can we reduce fault current on primary side by effective changes on Secondary side... what are the changes possible on Secondary side to reduce fault current on primary side

  • @Ragavenutb
    @Ragavenutb Před 3 lety +1

    Hi,if data markings on the CT's disappear how would one determine the correct ratio? Thank You.

    • @electricallectures
      @electricallectures  Před 3 lety

      Then you have to do it by hit and trial. One thing for sure the output is always 5. So by measuring secondary current and primary you can compute ratio

    • @Ragavenutb
      @Ragavenutb Před 3 lety

      @@electricallectures so i basically run 100a through the line and measure Ct output amps. If its 2.5 its primary is 200a. But due to impedance and accuracy class, output can't be accurate right?

  • @Artistic_S0ul_
    @Artistic_S0ul_ Před 2 lety

    I have a question. Please could you tell me, what would happen if the flow primary current is 300 A permanently, and the ratio CT is only 200/5 A? Thanks by the answer.

    • @electricallectures
      @electricallectures  Před 2 lety

      Ct will saturate and 5 A will continue to flow

    • @Artistic_S0ul_
      @Artistic_S0ul_ Před 2 lety

      @@electricallectures Thanks a lot by the answer.

    • @fabianm.2982
      @fabianm.2982 Před rokem

      @@electricallectures I don't agree, please elaborate further. There are times when you can set the pick to be above the 100% rating, which is 5A. I have seen the CT's rated 600/5A and relay set at 1.2 of the primary current. Is that a wrong practice or what?

    • @electricallectures
      @electricallectures  Před rokem

      Absolutely wrong. Ct can only produce 5A. As far as pickup is concerned , 1.2 can be set if the maximum primary current is 600. Let say ur relay is supposed to trip @400A which is 1.2 times. Now ur ct is 600/5 and it will work in this situation

  • @suryasreedharreddy2277

    What happens on primary side current when burden increases on Secondary side

    • @electricallectures
      @electricallectures  Před 3 lety

      No effect on primary but if burden exveed the ratio will be disturbed and so as secondary current

    • @suryasreedharreddy2277
      @suryasreedharreddy2277 Před 3 lety

      If the Secondary winding is replaced with reactance instead of short circuit after sometime then what happens on primary side current

  • @debarpanchanda7506
    @debarpanchanda7506 Před 2 lety

    Sir could you please explain any practical application or uses of reduction of CTR...? It's will be much beneficial for me..Thanks in advance sir.. 🙏🙏🙏

    • @electricallectures
      @electricallectures  Před 2 lety

      Do you want to ask usage of CT . I dont actually understand your question. Reduction of ctr

  • @user-uf5wg7ex2i
    @user-uf5wg7ex2i Před 7 měsíci

    200/2 farmola 😊

  • @michelvidallo7288
    @michelvidallo7288 Před 11 dny

    i cannot understand you bus or bar type?? wtf