Upgrading your T500 Boiler, two things you need to do!

Sdílet
Vložit
  • čas přidán 10. 09. 2024

Komentáře • 16

  • @MysticDonBlair
    @MysticDonBlair Před 10 měsíci

    I don’t have this still, but I really enjoyed watching.
    I think like all hobby distillers, I do want one of every type of still (and distilling gadget) available 😅
    BTW: I still learn a lot from how to videos like this one.
    Thanks for sharing 😊

    • @brewingadvice
      @brewingadvice  Před 10 měsíci

      Thank you so much @MysticDonBlair for your comments. I totally agree which is why I have 2x Air Stills, 1x Air Still Pro, 1x Water Distiller, 2x T500 boilers (1 badly dented), 3x Love Brewing Boilers Version 2, 1x Love Brewing Boilers Version 3, then a load of condensers and extras! I need a bigger house!

  • @garrymcgaw4745
    @garrymcgaw4745 Před 10 měsíci

    Thank you for that life hack I'm going to do that plug, I've already changed the tap. Cheers mate. 👍.

  • @stuartpowell4905
    @stuartpowell4905 Před 10 měsíci +1

    Good upgrade tips.Your boiler is perty dented up. Your losing internal volume like that. put a deflated basketball in side and blow it up. That will push most of the dents out. Enjoy your videos. take care

    • @brewingadvice
      @brewingadvice  Před 10 měsíci

      Hi @stuartpowell4905, many thanks for this and your other comment, I really appreciate it. Glad you like my videos.

  • @martink9785
    @martink9785 Před 10 měsíci

    Man, i gotta fit an iec socket in mine! It almost looks like i might fit an scr in there too. Thank you for making this 👍👍👍👍

    • @brewingadvice
      @brewingadvice  Před 10 měsíci +1

      Thanks @martink9785. Be careful with adding an SCR as SCR units get very hot and the base of the boiler also gets hot. Having them both in the same place will shorten the lifespan of the SCR. If you are going to do it, make sure you add a fan (with holes) so cooler air can be pulled in & also add some exit holes for the hot air. Personally I would have it external, but it may be fine.

    • @martink9785
      @martink9785 Před 10 měsíci

      @@brewingadvice that’s a good point, thanks. I think I’ll just fit it in the box that I have. But will definitely fit an iec socket to the boiler. I noticed that my cable is developing an odd shape near where it exits, presumably from bending and having stuff pushed up against it.

    • @brewingadvice
      @brewingadvice  Před 10 měsíci +1

      Yes, cable bunching or kinking can be due to compression, or the grip inside the boiler could be a little loose and some is coming outside. This isn't really an issue, but if that is the case, try to push some back inside so it doesn't get too tight internally.

  • @stuartpowell449
    @stuartpowell449 Před 10 měsíci

    Good upgrade tips . Your boiler is perty dented up. Your losing internal volume like that. Put a deflated basketball 🏀 in side and blow it up. That will push most of those dents out. Enjoy your videos. 👍

    • @brewingadvice
      @brewingadvice  Před 10 měsíci

      Great idea to use a deflated baseball. Don't worry though, I don't use this boiler. I was given it by a friend who caused the implosion. They gave it to me to adopt and play with it so I could learn and not damage my own T500.

  • @garethlister4332
    @garethlister4332 Před 10 měsíci

    The new version comes with that tap now

    • @brewingadvice
      @brewingadvice  Před 10 měsíci

      Yes, I have seen this and they have also added two power switches for the two heating elements. These are great improvements.

    • @garethlister4332
      @garethlister4332 Před 10 měsíci

      Any idea if we can run it on one element once it's up to temp?

    • @brewingadvice
      @brewingadvice  Před 10 měsíci +1

      So, the new T500 boiler that has two switches on it, yes you can run them individually or both at the same time. I think though that they are both rated at 1,250W, which might be a little low to keep it in the sweat spot for distilling (it will be running at 50% power). For a normal 25 litre wash and a heating capacity of 2,250W, you want to run the boiler at around 72% power. It is likely that a separate SCR is still required to get it working well.