One way slab Bar Bending Schedule | BBS of one way slab | Engineering tactics

Sdílet
Vložit
  • čas přidán 7. 09. 2024
  • #Engineeringtactics
    In this video I discussed about one way slab Bar Bending schedule, how to calculate steel quality of one way slab,BBS of one way slab etc.
    Step 1 :- no.of main bar and distribution bar
    Step 2 :- cutting length of main bar and distribution bar
    Step 3 :- Top Extra bar
    Engineering tactics
    Blog: ENGINEERING TACTICS
    engineeringtac...
    Follow me in INSTAGRAM: / asifansari131
    FACEBOOK account: www.facebook.c...

Komentáře • 162

  • @SanjayKumar-ew4nm
    @SanjayKumar-ew4nm Před 5 lety +11

    Thank u for the videos..ur teaching/explanation is very good too.
    One of my request is upload videos on site practical works if possible,if not all then atleast upload a video on staircase from line Dori measurement, shuttering,and rebaring..it will be very helpful and will be thankful too.
    Regards

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  Před 5 lety +2

      Thanks for such a nice comment.....sanjay sir
      Yup I will try to upload video on that as you said......👍

    • @SanjayKumar-ew4nm
      @SanjayKumar-ew4nm Před 5 lety +1

      @@ENGINEERINGTACTICS will be eagerly waiting..also if possible upload a video on foundation layout and marking with line Dori , by chuna at site by studying foundation drawing and centre line plan..my two humble request..one on staircase and another one on foundation..
      Regards

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  Před 5 lety

      Thanks for giving me this topic yes if possible I will make video on that....if started a new project then.

    • @TheDynamicEngineers
      @TheDynamicEngineers Před 4 lety

      i have uploaded videos from site works. you can watch it.

    • @ANOOPSINGH-sv5ow
      @ANOOPSINGH-sv5ow Před 3 lety

      Xxxxxxxxxxxxxxxxxxx

  • @sudhakarnarayankar7484
    @sudhakarnarayankar7484 Před 3 lety +2

    बहुत बढिया समजाया सर 🙏
    भगवान आपका भला करे 🙏

  • @arkoprovodutta2313
    @arkoprovodutta2313 Před 4 lety +10

    MISTAKES AT 2 PLACE ----
    1. No. of MAIN BAR,
    = [{8000 - (2×25)} ÷ 150] + 1
    = 54 nos.
    2. Cutting length of DISTRIBUTION BAR, (as per drg.)
    = 8000 - (2 × 25) mm
    = 7950 mm

    • @kaakib8841
      @kaakib8841 Před 2 lety

      In no. of distribution bar also we should minus the cover at both side (even though there is beam) otherwise the 1st & last distribution bar will overlap with the inner bar of beam.

  • @asif4t
    @asif4t Před 2 lety +1

    Appreciate your very informative video good job love from pakistan.

  • @nitinushinde
    @nitinushinde Před 5 lety +5

    helpful for beginners. good job.

  • @syedazharali8484
    @syedazharali8484 Před 4 lety +1

    It's very helpful for freshers engineers

  • @vasanthroyal8393
    @vasanthroyal8393 Před 3 lety +1

    Thank you for your videos..
    My doubt clarify...

  • @abdulkabir8067
    @abdulkabir8067 Před 4 lety +1

    Your way of teachin is very good

  • @Abhiyadav56114
    @Abhiyadav56114 Před 3 lety

    Apki video dekhkar interview clear kiya thanku dear

  • @sriharibehera3475
    @sriharibehera3475 Před 3 lety +1

    Very useful trick ..tq 😊 sir jii

  • @ashokkandukury2870
    @ashokkandukury2870 Před 3 lety +7

    Friend appreciate your efforts,
    But what about extra bars between alternative cranks.
    No. Main extra Bars 8000/300+1
    Length of bar L/4+beam width/2

  • @JOY-001
    @JOY-001 Před 3 lety +1

    Thanks sir ji

  • @ARMSTRUCTIONIN
    @ARMSTRUCTIONIN Před 2 lety

    Very amazing vedio thanks and keep sharing

  • @israengineerfouru5219
    @israengineerfouru5219 Před 8 měsíci

    Jazakallah
    One thousand times thanks

  • @Anonymous-kr5er
    @Anonymous-kr5er Před 4 lety +1

    Very nice explanation bro ....😍😍

  • @vikramthakur5940
    @vikramthakur5940 Před 3 lety +1

    Jay hind sir mst samjaya aap ne

  • @yashodhanchavan9206
    @yashodhanchavan9206 Před 3 lety +1

    Perfect video

  • @sothyun449
    @sothyun449 Před 5 lety +2

    Good teaching.

  • @anieketshelar5662
    @anieketshelar5662 Před 2 lety +1

    Thank you so much sir

  • @mrinmaybiswas3336
    @mrinmaybiswas3336 Před 4 lety +6

    Sir...Clear cover of slab is 25mm ...
    But u wrote on this problem...40mm

  • @vivekjagatap578
    @vivekjagatap578 Před 2 lety +1

    Very nice thanks

  • @arponbiswas3000
    @arponbiswas3000 Před rokem

    Love from 😇🥰Bangladesh

  • @adilbabusmart3563
    @adilbabusmart3563 Před 4 lety +2

    Nice

  • @vireshtotad7937
    @vireshtotad7937 Před 4 lety +2

    Super bhi

  • @swainjwalapratapsingh2955

    Thank you sir

  • @SantoshKumar-sm3bd
    @SantoshKumar-sm3bd Před 5 lety +2

    Very nice sir

  • @v.k.prt.allknowledge4271

    Sir aapki video very helpful hai aap 2 way slab ka naap band kaise todte hai slab me men sariya jab jab dusre kamre me jati hai usko kaise naapte hai

  • @AbdulWahid-ic4zm
    @AbdulWahid-ic4zm Před 2 lety

    Great information.
    Plz one way and tow way slab ka details bata daein

  • @astrude4623
    @astrude4623 Před 4 lety

    very helpfull m from nepal

  • @Waseemkhan-eq1xl
    @Waseemkhan-eq1xl Před rokem

    Good information thanks

  • @user-cr2np7hn6o
    @user-cr2np7hn6o Před 6 měsíci

    Nice sir

  • @yasiransari6338
    @yasiransari6338 Před 3 lety +1

    Sir ek confusion hai agar jisko aap top extra bar bol rhe ho to phr , top distribution bar kha hai?? Or ham extra bar (in one way slab) along the shorter span provide karte hai....to phir kase top extra bar ki cutting lenth..distribution bar cutting lenth ke equal ho gayi..answer plzzz

    • @ankitkainwal1496
      @ankitkainwal1496 Před rokem

      sahi baat hai....iss video m along longer span diya h isne top extra

  • @bharatsharma1009
    @bharatsharma1009 Před 4 lety +6

    I think you missedExtra curtailment L/5 and L/7 also provided in both direction near ends

  • @anaadikashyap2023
    @anaadikashyap2023 Před 3 lety +1

    thanks bro

  • @MuhammadIsmail-yh9zb
    @MuhammadIsmail-yh9zb Před 2 lety

    Very good .

  • @sahilzayn584
    @sahilzayn584 Před 3 lety +2

    ❤️

  • @Vivek-rw2jx
    @Vivek-rw2jx Před 3 lety

    got clear idea!!! thank you!!!

  • @vivekmohite2613
    @vivekmohite2613 Před 5 měsíci

    For distribution bar you take 40mm but clear cover is 25mm

  • @ahmadnawazcivilengnieer4225

    Very good

  • @bikashsahoo999
    @bikashsahoo999 Před 3 lety +1

    Two way slab ka bbs teaching achhe he

  • @saleemsrk789
    @saleemsrk789 Před 11 měsíci

    Tq

  • @priteshramakantshah5550

    Your explained was very best but sir I had one doubts main, and destubition bar was gone over beam lenth or gone so how

  • @satishpawar6060
    @satishpawar6060 Před rokem

    Explain of Crank bar

  • @sahilmulla2713
    @sahilmulla2713 Před 4 lety +1

    Sir,
    can u plz explain
    { how the cutting lenght is same for distribution bar and top extra bar in detail?}

  • @tankneel509
    @tankneel509 Před 3 lety +1

    sir kya cutting length me development length provide nahii hoti??? pls ans ..

  • @shwetaharle5528
    @shwetaharle5528 Před 2 lety +3

    You didn't add extra top bars between crank bars along shorter span

  • @AmithTaba
    @AmithTaba Před 3 lety

    Thank you friend

  • @vikasgautam2385
    @vikasgautam2385 Před 2 lety

    Crank bar L/4 dete Hain kis is code mein likha hua hai please reply

  • @civilengineerview681
    @civilengineerview681 Před 2 lety

    Sir 👍 explanation 1 doubt sir
    How to add lapping length sir pls tell sir

  • @vimalnath4419
    @vimalnath4419 Před 5 lety

    too good bro for bbs ....can u plz site reinforcement picture

  • @suryadev8207
    @suryadev8207 Před 5 lety +3

    Bro i need curtailment beam reinforcement calculation

  • @utkarshsingh5029
    @utkarshsingh5029 Před rokem +1

    IS 456:2000 ke hisab se toa clear cover for slab is 20mm then why are u taking 40mm

  • @deeplook8600
    @deeplook8600 Před 2 lety

    Sir one side crank bar hai to other side top extra L/4 pe lagega na sir

  • @ce_parmeshwaryadav7836
    @ce_parmeshwaryadav7836 Před 3 lety +2

    👍👍👍👍

  • @bhaveshnagphase3619
    @bhaveshnagphase3619 Před 4 lety +5

    Sir cutting length of distribution bar me 8000-(2* slab cover) Hoga na beam Ka Nahi na ? As per plan as shown in video

  • @rohits1288
    @rohits1288 Před 2 lety

    Sir isme top extra bar jo nikli h wo both sides 12 h wo bhi 8m ke span ke liye nikla h. To sir ye value 8m ke span ke liye km nhi h kya ?

  • @ronaldkumar1196
    @ronaldkumar1196 Před 3 lety

    Please calculate using side square

  • @faizanalisiddiqui1748
    @faizanalisiddiqui1748 Před 4 lety

    Bro plz mention Is code where were we got a thumb rule and formulaes

  • @dheerajkhanal7251
    @dheerajkhanal7251 Před 4 lety

    Toh kya, quantitu surveying pirs manually hi karna padtah

  • @naveenreddyemani8731
    @naveenreddyemani8731 Před 4 lety +1

    For no of bars 8000-2×covers can be done so over all problem is wrong

  • @AAProductionsofficial
    @AAProductionsofficial Před 5 lety

    Chairs also provided..
    So how we calculate chairs cutting length..

  • @sajantalks
    @sajantalks Před 3 lety

    Thank you so much mentor ❤️..

  • @rncvlogs5465
    @rncvlogs5465 Před rokem

    Top distribution baar ke baare me koi jikr hi nhi kiye sir . Kya wo jaruri nhi hota kya

  • @sathyalakshmiv7010
    @sathyalakshmiv7010 Před 4 lety +1

    Sir can we use 40d for Ld(development length)?

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  Před 4 lety

      Development length decided according to concrete grade and steel grade.....in RCC drawing, RCC consultant gives how much we can take ld.
      Some time 40d , 45d, 50d, 55d

    • @jagdishvadher3322
      @jagdishvadher3322 Před 3 lety

      Hum site engineer ko structure engineer de hi dete hai drawing me so no problem

  • @neerajbairagi723
    @neerajbairagi723 Před 2 lety

    sir ek confution hai
    apne number of extra bar in 8mm to btadi but
    number of extra bar in 10 mm nhi btaya

  • @abidkhan-ty4sy
    @abidkhan-ty4sy Před 3 lety

    Agar beam ka size upar ka 300mm hai ar neeche ka beam 230 hai to kaise karenge sir calculation

  • @sonugupta7593
    @sonugupta7593 Před 3 lety

    bend up bar kaise karte hain aur kaise uski length nikaalte Hain basic se bataiye
    Sariya ka kam chal raha hai vahan bed par kaise deni hai

  • @pareshnathmaji4194
    @pareshnathmaji4194 Před 5 lety +3

    Top extra bar crank ke andar ho raha hai kyu ji?

  • @shambhusingh3343
    @shambhusingh3343 Před 3 lety

    Yha pe extra bars or top extra bars nikalna parega..

  • @kanchanrathorekanchanratho5220

    नमस्ते सर् कोई अछी कम्पनी हो तो बताइयेगा ।

  • @mdnajmuddinshek7165
    @mdnajmuddinshek7165 Před 2 lety

    Sir aap cotyti flat hai one miter k 8 mm 62

  • @Everyday_Laughs_
    @Everyday_Laughs_ Před měsícem

    Bhai LD kyou nhi liya main bar mai

  • @khajask8113
    @khajask8113 Před 4 lety

    21x23 ko kitna ton chahiye.?

  • @opgamer115
    @opgamer115 Před 2 lety

    Sir 2 cc 25 n 40 kaise

  • @sumitkumar-ky9wf
    @sumitkumar-ky9wf Před 5 lety +1

    Sir 0.42d ke bare Mai details se bata sakte ho..

  • @easynirman9550
    @easynirman9550 Před 4 lety

    sir,
    are top extra bars are distribution bars...?

  • @rishikulshrestha8334
    @rishikulshrestha8334 Před 4 lety

    sir me Construction Work drawing , Interior Designing 3D model, House Plan ke 2D,3D banana chahata ho. leykin kya house plan ka plan Architect se PASS karvana hoga kya mujhe ?

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  Před 4 lety +1

      Agr apki wo khudki property hai or ap khud hi 2D ya 3D plan bana rhe ho...jisme government ka koi bhi involvement ni h to apko architect pass krane ki koi zarurt ni hai...
      Pr agr apko sirf confirm krna h ke jo plan ap banaye ho wo sahi h ya galat to ap sirf architect se suggestions le skte h.
      Or agr wo structure government ke under me aa raha h or sari chize on paper ho rahi h systematic to is time apko architect se pass krana hoga.

  • @CivilEngineer423
    @CivilEngineer423 Před 4 lety

    Sir Apne to Dekha bent one side but ap 1d×2why

  • @aniketraut8167
    @aniketraut8167 Před 5 lety

    Sir...ld kaise nikala

  • @ashokkandukury2870
    @ashokkandukury2870 Před 3 lety

    Cover for beams = 25 mm

  • @nikhchaudhari2167
    @nikhchaudhari2167 Před 4 lety

    Their is not ld taken while calculation of cutting length of main bar and distribution bar

  • @hassanhaider9651
    @hassanhaider9651 Před 3 lety

    sir why 45 degree multiplied by 2?

  • @rizwinetwork7786
    @rizwinetwork7786 Před rokem

    Hi

  • @mohitpanchal9648
    @mohitpanchal9648 Před 5 lety

    Sir Ji any slab ka hai fourmula

  • @sureshraika3282
    @sureshraika3282 Před 3 lety

    Top extra bar ki calculation me confusion hai

    • @kaakib8841
      @kaakib8841 Před 2 lety +1

      Easy hai.
      Jitne main bar honge.... Utne hi top extra bar hunge .... Length l/4

  • @bikramkumardutta9109
    @bikramkumardutta9109 Před 2 lety

    Sir main bar 8000mm ka tha aap to 3000mm leke calculation kiu kar rahe he

  • @ajeetnishad5151
    @ajeetnishad5151 Před 3 lety

    Sir directly Bata dijiye

  • @navedhasan3253
    @navedhasan3253 Před 2 lety

    45 degree ke chaar bend hai

  • @akankshagautam365
    @akankshagautam365 Před rokem

    Feet inch me btaiye

  • @dhirenhansdah7299
    @dhirenhansdah7299 Před 4 lety

    Cover kahaheya sir

  • @ibrahimaslam8099
    @ibrahimaslam8099 Před 4 lety +1

    Bhai jb calculation of no. Bar nikalte ho to total length se minus karenge clear cover...galat mt teach kro yr

  • @InderjeetSingh-lf4ib
    @InderjeetSingh-lf4ib Před 5 lety

    22 pehle cover to minus kar late no of bar nikalne se pehle

  • @sivaram6963
    @sivaram6963 Před 4 lety

    Bro,y there is no clear cover considered in continue slab.just (ld*2)

  • @MdSaif-ki3xx
    @MdSaif-ki3xx Před 4 lety +1

    Sir thi k h

  • @kishorekrishnapaul4698

    9d kiyu nahi kiya apne?

  • @navedhasan3253
    @navedhasan3253 Před 2 lety

    Aapne 2 liye hai

  • @satyavenipangi9966
    @satyavenipangi9966 Před 2 lety

    Sir Can u explain in english

  • @user-kf2nr1hn4n
    @user-kf2nr1hn4n Před 2 měsíci

    Sar PA ka nembar saned kar dena ❤❤

  • @dhanrajpatnure2710
    @dhanrajpatnure2710 Před 4 lety

    L/4 kaise nikalte hai

  • @bikashsahoo999
    @bikashsahoo999 Před 3 lety

    Sir one way slab ka bbs teching achha nehi lagta