Zone Control Valve Assembly | ZCV Practical | Firefighting | in Urdu/Hindi

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • This is a practical firefighting System video about the "Zone Control Valve (ZCV) Assembly" in Urdu / Hindi language. It is a practical detailed explanation video for basic learning information about the ZCV Assembly of the fire suppression system. Mostly ZCV assembly is used in a large piping network of firefighting sprinklers systems to control or monitor easily through the zone in case of fire. It is also important for Firefighting or MEP technical staff. Here sharing my experience and knowledge that will be helpful for learning & growing for Engineers & Technical staff who are interested in this topic.
    I have explained the following points here:
    1. Zone Control Valve Assembly?
    2. Supervisory Valve
    3. Pressure Reducing Valve (PRV)
    4. Flow Switch
    5. Test Drain
    I am ensured that you can get theoretical as well as practical knowledge of ZCV assembly through the above link & video if you will watch till the end.
    Related videos for your watching:
    1. NFPA-14 Pipe Schedule Method for Standpipe
    Video's link: • NFPA 14 Pipe Schedule ...
    2. NFPA-14 Flow Rate Requirements for Standpipe & Hose System
    Video's link: • NFPA 14 Flow Rate Requ...
    3. NFPA-14 Pressure Design Requirements of Standpipe & Hose System
    Video's link: • NFPA-14 Pressure Desig...
    4. NFPA-14 Classes of Standpipe Systems
    Video's link: • NFPA-14 Classes of Sta...
    5. NFPA-13 Pipe Schedule Method Designing
    Video's link: • NFPA 13 Pipe Schedule ...
    6. NFPA-13 Sprinkler Heads Distribution
    Video's link: • NFPA-13 Sprinkler Head...
    7. NFPA-13 Density & Area of Sprinkler Operation
    Video's link: • NFPA 13 Density & Area...
    8. NFPA-13 Sprinklers Discharge Characteristics
    Video's link: • NFPA-13 Sprinklers Dis...
    9. Wet Riser Landing Valve System
    Video's link: • Wet Riser Landing Valv...
    10. Testing of Wet Riser Landing Valve System
    Video's link: • Testing of Wet Riser L...
    11. Fire Hose Reel System
    Video's link: • Fire Hose Reel System ...
    12. Testing of Fire Hose Reel System
    Video's link: • Testing of Fire Hose R...
    13. Converting Pump Head to Pressure or Vise Versa
    Video's link: • Converting Pump Head t...
    14. Difference Between Pressure Reducing & Pressure Restricting Valve
    Video's link: • Difference Between Pre...
    15. Difference Between Pressure Relief & Pressure Safety Valve
    Video's link: • Difference Between Pre...
    16. Combined Firefighting System Water Demand
    Video's link: • Combination Standpipe ...
    17. Types of fire sprinkler system of fire suppression systems
    Video's link: • Types of fire sprinkle...
    18. Dry Pipe Fire Sprinkler System
    Video's link: • Dry Pipe Fire Sprinkle...
    19. Preaction Sprinkler System NFPA13
    Video's link: • Preaction Sprinkler Sy...
    20. Single Interlock Preaction Sprinkler System
    Video's link: • Single Interlock Preac...
    21. Double Interlock Preaction Sprinkler System
    Video's link: • Double Interlock Preac...
    22. Main Components of Fire Fighting Pump Room Part-1
    Link: • Main Components of Fir...
    23. Main Components of Fire Fighting Pump Room Part-2
    Link: • Main Components of Fir...
    24. Main Components of Fire Sprinkler System Part-1[Except Pump Room]
    Link: • Main Components of Fir...
    25. Main Components of Fire Sprinkler System Part-2 [Except Pump Room]
    Link: • Main Components of Fir...
    26. Testing of Fire Sprinkler System & operation of ZCV assembly
    Link: • Testing of Fire Sprink...
    = FOLLOW ME ON SOCIAL MEDIA =
    #TanweerAhmed #ZCV #Firefighting
    FACEBOOK: / tanweersethar
    LINKEDIN: / tanweer-ahmed-00142631
    CZcams: / tanweerahmed

Komentáře • 175

  • @vivekkalidas
    @vivekkalidas Před 4 lety +8

    hi sir, thanks for your videos. i have seen lots of youtube video but nothing is clear as like yours. Even in firefighting course the teach like this.

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      Thank you

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      Watch my this video, then ZCV concept will be more clear:
      czcams.com/video/QUjPHz_R6Mw/video.html

    • @ziyamasad2709
      @ziyamasad2709 Před 3 lety +1

      @@TanweerAhmed Thanks alot too you .. brother...

    • @edwinuy9443
      @edwinuy9443 Před 2 lety +1

      Mashallah very Nice video & knowledge shearing. 🌟🌟🌟🌟🌟

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Thanks

  • @kartikkapat293
    @kartikkapat293 Před 4 lety +4

    Best Chanel for fire fighting...
    Thank you sir.

  • @vashishthparikh
    @vashishthparikh Před rokem +2

    Your all videos are in so much details and depth. Even non technical person also understand. Thank you very much sir for all the knowledge you share. Really Appreciate

  • @mohammedmubeen4727
    @mohammedmubeen4727 Před 4 lety +2

    I saw this videos I got good knowledge thank you sir

  • @farazkhan2279
    @farazkhan2279 Před 4 lety +1

    Knowledge ke alawa you have very good explanatory skills.. Great job

  • @VArjun26
    @VArjun26 Před 4 lety +3

    Hi sir, please sharing videos related to fire fighting system. Very helpful information.

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      I will continue upload videos about firefighting in future. Thanks for your interest

  • @abhinavkumarsingh6792
    @abhinavkumarsingh6792 Před 3 lety +1

    thank you so much for such unique live information

  • @nisarsethar3949
    @nisarsethar3949 Před 4 lety +1

    Behtareen video hy.

  • @junedalam7381
    @junedalam7381 Před 2 lety +1

    Nice video sir video banane ke liye thanks

  • @niazhussain2993
    @niazhussain2993 Před 3 lety +1

    Sir thank you very much for site recording. Thanks thanks thanks

  • @mohammadkhan3796
    @mohammadkhan3796 Před 9 měsíci +1

    Thanks Mr tanweer

  • @atif-aftab1atif330
    @atif-aftab1atif330 Před 2 lety +1

    GREAT

  • @mzs9262
    @mzs9262 Před 4 lety +2

    Kammmmmmmallll love

  • @farhanhaider3734
    @farhanhaider3734 Před 4 lety +1

    I'm from unilever pakistan.....thanks for video

  • @sunilraj4423
    @sunilraj4423 Před rokem +1

    Good

  • @shahzadnadir8805
    @shahzadnadir8805 Před 4 lety +1

    Behtreen video

  • @mskvideo8950
    @mskvideo8950 Před 2 lety +1

    Sir aap Pakistan se ho 👍I'm from India thanks to information

  • @Irfanali-gp7ev
    @Irfanali-gp7ev Před 4 lety +1

    Zabardast video

  • @faizankhan-bo7sl
    @faizankhan-bo7sl Před 4 lety +1

    Important video

  • @MirBaqirAliSethar
    @MirBaqirAliSethar Před 2 lety +1

    Good knowledge

  • @AsgharAli-mo7gx
    @AsgharAli-mo7gx Před 4 lety +1

    السلام علیکم سر،زبردست ڈیٹیل دے دیا آپ نے شکریہ۔
    لیکن سر یہ اسمبلی وال میں جو کیبل ہیں وہ mov کیلئے ہیں یااور کوئی کنٹرول ؟
    اسکا تھوڑا سا اکسپلین کرلیں ۔ شکریہ

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      I will make video about control wiring of ZCV

    • @AsgharAli-mo7gx
      @AsgharAli-mo7gx Před 4 lety +1

      @@TanweerAhmed thanks sir, we will wait Insha Allah

  • @riyasatali6368
    @riyasatali6368 Před 7 měsíci +1

  • @AjitKumar-ol8ue
    @AjitKumar-ol8ue Před 4 lety +1

    Excellent

  • @rehanzahid9600
    @rehanzahid9600 Před 4 lety +1

    Very nice bro...

  • @habeebrk
    @habeebrk Před 4 lety +1

    Good work bro

  • @muhammadejaz8021
    @muhammadejaz8021 Před 3 lety +1

    Excellent sir g

  • @amulyapankaj3961
    @amulyapankaj3961 Před 4 lety +1

    Please make a vedio over water storage tank designing and pipe sizing methods at branch

  • @amr5125
    @amr5125 Před 3 lety

    ممتاز

  • @MohammadAli-qp7gx
    @MohammadAli-qp7gx Před 3 lety +1

    Thanks for your nice videos. Could you make a video for sprinkler hydraulic calculation method!

  • @tanvirmunna5862
    @tanvirmunna5862 Před rokem +1

    Assalamualykum sir.
    If i set the riser of sprinkler far from the stair. And set the zone controll at the middle side of the building. Is that issue ase per nfpa?

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      Standpipe system's hose connections, hose cabinets or hose compartments are required in landings of staircase and exit or entry doors therefore mostly riser pipes are installed on the staircase side. You can install a riser pipe in the middle of the building but pipes connection may be difficult/

  • @motivationalquotes2.5m84

    Sir os& y valve and supervisory valve me kya difference hai

    • @TanweerAhmed
      @TanweerAhmed  Před rokem +1

      OS&Y valve with tempering switch will be supervisory valve. Also Supervisory Butterfly valve available. Here both function will be same but physical structure change.

  • @syedasadshah3931
    @syedasadshah3931 Před 7 měsíci +1

    Boss Zone Control valve say flow switch ka distance kitna hona chiyay?

  • @MuhammadAli-cc7cm
    @MuhammadAli-cc7cm Před 4 lety +1

    السلام علیکم
    Dear Sir,
    Kindly make a video for supervisory switch and fire alarm.
    Thanks

  • @ashutoshpandey8680
    @ashutoshpandey8680 Před 4 lety +1

    High rise building me water pressure top par kitna hoga and overhead tank aur booster pump ke case me pressure distribution kaise kaam karte he please explain.

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      Kindly watch my firefighting videos and check in my playlist. I hope you will understand

  • @sherin7222
    @sherin7222 Před 4 lety +1

    Why check valve is providing in combined sprinkler riser ZCV Assembly . Please explain.

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      The requirement for a check valve to be included as part of the connection to the sprinkler system is to permit the standpipe riser to be drained and refilled in a limited amount of time should repair be necessary to any portion of the standpipe riser, fire department hose valves, pipe, and fittings, etc.

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      The check valve arrangements in
      ZCV assembly permit the standpipe system to be drained while allowing the sprinkler pipe to remain water filled. In general, the check valve between the two systems maintains the water volume supplied within the sprinkler piping, thereby limiting the drain and refill time of the overall combination standpipe/sprinkler system. In addition, when combination risers are cross connected (loop or dual feed), the check valves will limit the flow to the appropriate floor where sprinklers have activated and limit circulation of water throughout multiple levels of the building.

    • @sherin7222
      @sherin7222 Před 4 lety +1

      Thank you👍🏻👍🏻

  • @mohammadshahzeb2459
    @mohammadshahzeb2459 Před rokem +1

    Sir why we use test drain valve?

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      Because if sprinkler glass break then when have to replace sprinkler after drain pipelines. Moreover, if you drain valve without sprinkler glass break then ACV activate in pump room and FACP panel inform about zone activation

  • @PradeepKumar-uu9im
    @PradeepKumar-uu9im Před 2 lety +1

    Whater curon nozal agar chalu ho jay to floor suich signal dega ae hame pata nahi janna hai

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Yes, it will provide signal at fire alarm panel and you have reach at the zone where is happened

  • @amitsinghal5955
    @amitsinghal5955 Před 4 lety +1

    Sir I have a godown of Confectionery of 300 square yard. What fire fighting system we should install. Please guide

  • @nayeemsaleem7466
    @nayeemsaleem7466 Před 4 lety +1

    It's a Pressure reducing valve. It is required to maintain pressure not more than 175 psi.

  • @Rakib.Mahmud
    @Rakib.Mahmud Před 4 lety +1

    Vaiya please Help me. NFPA As a rule how to calculated fire centrifugal pump water pressure bar and bar to galleon to pound. How to calculation. Please Help me vaiya.

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      Watch my video i.e. " NFPA-14 Pressure Requirements" which to be helpful for you

    • @Rakib.Mahmud
      @Rakib.Mahmud Před 4 lety +1

      Thank you vaiya

  • @habeebrk
    @habeebrk Před 4 lety +1

    Bro, I have a light hazard building with 12000m2 area, Can I Provide Fire water supply with Single riser with single Alarm Check valve and multiple Zone control valves?
    Or 3 riser with 3 Alarm check valve is must? (Bcs asper nfpa single riser can serve 4000m2 area only)

  • @ajishashok6550
    @ajishashok6550 Před 4 lety +1

    Hi sir, Can you please do a video on Vertical turbine fire pump?

  • @habeebrk
    @habeebrk Před 4 lety +2

    Bro, I have a single zone wet sprinkler system, Does it required both alarm check valve and zone control valve or alarm Check valve only ?

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      Single zone means one zone therefore no need ZCV assembly and only required Alarm check valve assembly which will fulfill the NFPA requirements

    • @habeebrk
      @habeebrk Před 4 lety

      @@TanweerAhmed Good, Expected answer,
      In a combined system (sprinkler &FHC) from where we start fire hose connection, normally FHC line will start just before zcv na?
      If no zcv, from where we start fhc line ?

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      @@habeebrk ZCV is not used in fire hose connection because we use manually fire hose and ZCV is required in auto sprinkler system

    • @habeebrk
      @habeebrk Před 4 lety

      @@TanweerAhmed I mean for combined system

    • @nayeemsaleem7466
      @nayeemsaleem7466 Před 4 lety

      @@habeebrk as per your case as it is combine system you can take fhc individual connection from main sprinkler line but with isolation valve after each connection to control fhc.

  • @matiurrahmankhan1889
    @matiurrahmankhan1889 Před 2 lety +1

    Tanweer Bhai agar kaam shikhna hoto kya Karin

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Kaam sikhnay k leay kaam Karna paray ga. Start practical work like job

  • @ziyamasad2709
    @ziyamasad2709 Před 3 lety +1

    Assalamualaikum wr.please let me know for how much area one zcv will be considered.

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      As per std 8.2.1 on NFPA 13 it indicates an area of 3720m^2 per control valve, this works out to be 400 sprinklers per control valve

    • @ziyamasad2709
      @ziyamasad2709 Před 3 lety +1

      @@TanweerAhmed jazakaallah bhai...

    • @ziyamasad2709
      @ziyamasad2709 Před 3 lety +1

      @@TanweerAhmed what will be the main line pipe size if 3720m^2 and 400 sprinkles can be served ,is there any limitations of pipe size .

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Kindly watch my video of pipe schedule method regarding pipe size & number of sprinklers. Also another video pipe schedule method for Standpipe

  • @hadinadeem3525
    @hadinadeem3525 Před 4 lety +1

    Kamal ka describe kya

  • @waseemnaveed1138
    @waseemnaveed1138 Před 4 lety +1

    AoA sir kya sprinkler 175 psi k pressure pr design nhi hte?

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      Max design pressure of sprinkler is 150 to 175 psi

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      But working recommend pressure is 50 to 75 psi

    • @waseemnaveed1138
      @waseemnaveed1138 Před 4 lety

      @@TanweerAhmed sir aik jagah zcv me contractor prv nahi laga raha hai kyu pump 8bar ka pressure deraha hai kehta hai zarurat nahi hai prv ki zcv me

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      If 8 bar = 116 psi pressure of pump then water move up side to floor then gradually pressure decrease in height therefore I also suggest to no need PRV with ZCV (standard recommend working pressure 50 to 75psi but should be under pressure of sprinklers design) if our sprinklers design pressure is 150 to 175psi then no need to install PRV with ZCV

  • @engrikram876
    @engrikram876 Před 3 lety +1

    From where we take connection for outer fire hydrant in combined sprinkler and fire hydrant system

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      From discharge header of fire pumps

    • @engrikram876
      @engrikram876 Před 3 lety

      @@TanweerAhmed thanks to reply
      Please confirm me from header or from riser
      secondly what will be dia of 4 or 6 inch if our header is 4 inch

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Riser means standpipe: this pipe is installed vertically for water flow upward to building, while hydrant are installed outside of building at ground floor (Note: no hydrants are installed inside of building, these are called landing valve or standpipe hose connection with or without cabinet and hose reel)

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      If header is 4" means your system is not combine system. In hydrant system, minimum main pipe should be 6" diameter as per standard requirements.

    • @engrikram876
      @engrikram876 Před 3 lety +1

      @@TanweerAhmed thanks to reply our header is 6 inch and hydrant are out side building
      My question is that we will take two connection from header one for riser and one for out side hydrant or only one connection for riser and than from riser we will take a connection for hydrants.
      Thanks for your valuable input

  • @abidameen7933
    @abidameen7933 Před 4 lety +1

    Aoa bro why there isn't nrv in zcva?
    And if I use gate valve instead of supervisory valve ?

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety +1

      W.salam, No need NRV in ZCVA because NRV is installed in Pump room. In firefighting standard used supervisory valve because this valve give ON/OFF status on FACP & also physically status, while gate valve does not provide this information.

    • @waqarahmed4593
      @waqarahmed4593 Před 4 lety +1

      I worked at Doha metro and we used NRV in zcva

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      If you are away from pump Room or no access in pump Room then you can use NRV. But NFPA-13 allow NRV with ZCV

  • @siddheswarray9041
    @siddheswarray9041 Před 4 lety +1

    Sir fire fighting system installation drawing Ka upor video Di ja

    • @TanweerAhmed
      @TanweerAhmed  Před 4 lety

      There is available video in my playlist of firefighting. If you have any questions then you can ask

  • @jawheroueslati5681
    @jawheroueslati5681 Před 4 lety +1

    thanks for videos sir but i need documentation english because my langue arabic english please

  • @sahidahmed8092
    @sahidahmed8092 Před 3 lety +1

    Assalamualaikum
    Sir Aap Ka Company Ka hai

  • @kaworld6626
    @kaworld6626 Před 2 lety +1

    Bhai ZCV ka zikar hi nhi hai kahi 🙄

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      These all things are part of Zone Control Valve Assembly

  • @dileshwarsahu6928
    @dileshwarsahu6928 Před rokem

    Sir 1 ICV m kitne sprinkler install Kiya ja sakta h

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      What is ICV?

    • @dileshwarsahu6928
      @dileshwarsahu6928 Před rokem

      @@TanweerAhmed installation control valve

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      As per NFPA 13:2019, 4.5.1 The maximum floor area on any one floor to be protected by sprinklers supplied by anyone sprinkler system riser or
      combined system riser shall be as follows:
      (1) Light hazard - 52,000 ft2 (4830 m2)
      (2) Ordinary hazard - 52,000 ft2 (4830 m2). Therefore on any one floor, you can install one Zone Control Valve Assembly and sprinklers quantity to be calculated according to hazard recommended area.

  • @muthumuruganm9795
    @muthumuruganm9795 Před měsícem

    Please add English suptitle brother

  • @zinanvlog3020
    @zinanvlog3020 Před 3 lety +1

    Assalamu alaikkum
    Sir aappka wattsapp nambar thega

  • @MohammedVIPsmile
    @MohammedVIPsmile Před 4 lety +1

    No English

  • @abduljabbaransari8462
    @abduljabbaransari8462 Před 4 lety +1

    Good