Measurement of oxide layer thickness of water-cooled wall tubes. Ultrasonic thickness gauge.

Sdílet
Vložit
  • čas přidán 11. 06. 2024
  • Beijing TIME High Technology Ltd.
    www.tgindt.com/
    Email: export@timegroup.com.cn
    WhatsApp: 008615201625204
    ------------------------------------------------------------------
    Measurement of oxide layer thickness of water-cooled wall tubes. Ultrasonic thickness gauge. Coating thickness gauge.
    Ultrasonic Thickness Gauge TIME®2190 with A/B scan
    TIME®2190 is the latest high-end ultrasonic thickness gauge developed by TIME Group Inc. It adopts pulse reflection principle, that is, the transducer sends ultrasonic pulses to travel through the test object and receives the reflection pulse from the backwall of the object. TIME2190 can nondestructively monitor the thickness of almost any material like metals, plastics, composites, fiberglass, ceramics, and glass with A scan/B scan. It is used to test the wall thickness and corrosion of various kinds of plates, pipes, boilers, vessels across industries like metallurgy, shipbuilding, machinery, chemical, aerospace, power, automotive, oil and gas, manufacturing and others. www.tgindt.com/Product_detail...
    Features
    ⚫ A-scan waveform can be displayed for echo analysis and measurement of complex workpiece;
    ⚫ Compatible with many types of transducers, both single and dual element transducers;
    ⚫ Users can set blanks to shield aftershocks or clutter;
    ⚫ Echo-echo measures the true metal thickness with ignoring the thickness of coating layer.
    ⚫ Thru-coat technology measures metal and nonmetallic coating thickness.
    ⚫ Signal auto-amplification function (centered display of the detected echo);
    ⚫ Adjustable voltage variable pulse width square wave pulse generator;
    ⚫ Single value B-scan display function;
    ⚫ Users can turn on fast measurement mode up to 20 times per second;
    ⚫ Alarm function allows users to set the upper and lower limits of the alarm;
    ⚫ Differential, maximum and minimum display mode;
    ⚫ Store up to 500,000 measured values and waveforms.
    Coating Thickness Gauge TIME®2605
    TIME®2605 is a digital coating thickness gauge for non-destructive dry film thickness (DFT) measurement. It is equipped with various probes to test both ferrous and non-ferrous materials. This portable thickness gauge stands out due to its super high accuracy and large memory. www.tgindt.com/Product_detail...
    Features
    ● Two principles of operation are adopted: magnetic induction (ferrous) and eddy current (non-ferrous) to take non-destructive measurements.
    ● Features two working modes: DIRECT and BATCH & two measuring ways: CONTINUE and SINGLE
    ● Statistics include the mean, maximum, minimum, test numbers and standard deviation.
    ● Memory of 10000 data
    ● Adjustment and Correction: the system error can be corrected by basic calibrating method.
    ● Alarming function: alarming automatically if measuring values out of pre-set limitation
    ● Battery Indicator: Low battery indicator
    ● Printing function: measuring value, statistic value can be printed
    ● Error warning Function: error warning in display during malfunction
    ● Manual or automatic shutdown.