  • How to repair ABB ACS 880-260A IGBT replacement and Testing after service

Komentáře • 7

  • @jvjayaraman2483
    @jvjayaraman2483 Před 11 měsíci +1

    Please prepare one video how to upload/download program ACS880

  • @VijayKumar-qu5py
    @VijayKumar-qu5py Před 5 měsíci

    Sir I have ACS580 showing fault 3130 after increasing load 35Hz upto 35Hz working properly

    • @Murugeswar_79
      @Murugeswar_79  Před 5 měsíci

      Please send complete details of the vfd ,parameter detais

  • @ILAYARAJAraja
    @ILAYARAJAraja Před 4 měsíci

    What is the value 0 or 0.35 for igbt failure values??

    • @Murugeswar_79
      @Murugeswar_79  Před 4 měsíci

      If igbt connected with on board driver ,most of the cases failure may be on IGBT module if you check gate having very high impedence compare with drian almost infinity check data sheet for the IGBT gate to drian source value

    • @Murugeswar_79
      @Murugeswar_79  Před 4 měsíci

      Bad IGBT gate values almost having less omic values if it is shortedgate omic value differ from 0 or some less values if gate short possible failure in driver board or driver ic

    • @ILAYARAJAraja
      @ILAYARAJAraja Před 4 měsíci

      Gate to collector values ? And Gate to Emitter value? Collector To Emitter/ Emitter to Collector? Please share these R and BDV values ....