  • This often misunderstood piece of equipment can give you lots of valuable information in motor, writing, and circuit board diagnostics. In this video I will show you some real world examples of wire testing with the Uni-T UT501A 1000V 1000V Insulation Resistance Meter Ground Tester MegOhmmeter.
    Amazon Link - amzn.to/45QsgdK
    Cheaper Alternative - amzn.to/45VdPFe
    This product was donated by Banggood, but my opinions are my own. Using the links below may earn me a commission, which greatly helps the channel.
    Uni-T UT501a - www.banggood.com/custlink/GDv...
    Mustool Meter - www.banggood.com/custlink/KD3...
    Bangood has 2 big sales. One through 11/12 and another from 11/13-11/28
    11/12
    Double 11 Shopping Festival www.banggood.com/custlink/Dm3...
    CLEARANCE Sale usa.banggood.com/marketing-Do...
    Money-Saving Tips www.banggood.com/custlink/D3m...
    Shop & Save With Great Coupon Deals www.banggood.com/custlink/Dmm...
    Top Brand Deals & Sale www.banggood.com/custlink/mGv...
    BANGGOOD Black Friday Sale 2021 (11/13-11/28)
    Money-Saving Tips For Best Deals www.banggood.com/custlink/3KG...
    Crazy Coupon Deals & Best Offers www.banggood.com/custlink/vGK...
    Big Brands New Arrival www.banggood.com/custlink/Kv3...
    Auto & Moto,Tools & Electronics Sale www.banggood.com/custlink/mKD...
    00:00 - Intro
    01:20 - Basic Continuity Test
    03:49 - Basic Insulation Resistance Test
    06:20 - Multiple Points of failure
    08:36 - Conduit Test
    10:12 - Final Thouhgts
  • Věda a technologie

Komentáře • 45

  • @fobmongrel9925
    @fobmongrel9925 Před rokem +4

    Thanks for those examples! Seeing these with my own eyes was very educational!

    • @AnotherMaker
      @AnotherMaker  Před rokem

      Ahh. Thanks for watching. Glad it was helpful. TBH, I learned a lot making it.

  • @procrastinator1842
    @procrastinator1842 Před rokem +2

    If you get the UT526 it has continuity built in, and also tests rcds. It's a bit more money but a much more complete and useful meter.

  • @ashvanbro9329
    @ashvanbro9329 Před 2 lety +2

    Yes you can use it with out the other

  • @pedrojardim325
    @pedrojardim325 Před 3 měsíci

    Good stuff men

  • @danielelise7348
    @danielelise7348 Před 11 měsíci +2

    It's not "zero" L, it's "O"L for "Open Loop" in continuity & "Over Limit" when in range.

  • @gregorynatanson6923
    @gregorynatanson6923 Před 4 měsíci

    Would it be ok to use it on fire alarm circuits to find a ground fault? Power 12-24 vdc and data 6-20 vdc. Thank you.

  • @user-ho7zh5yh3e
    @user-ho7zh5yh3e Před rokem +2

    8:36 Таким методом,с помощью ванны с водой можно измерять сопротивление изоляции рабочего инструмента- кусачек,пассатижей и отвёрток. Хороший способ.

    • @AnotherMaker
      @AnotherMaker  Před rokem

      That sounds like a fun experiment.

    • @user-ho7zh5yh3e
      @user-ho7zh5yh3e Před rokem

      @@AnotherMaker This will be the right experiment. One electrode (positive) is connected to the metal part of the tool and the second electrode (negative) is connected to a container of water. Immerse the insulated handles of the tool into the water and measure the resistance. If there is damage (cracks) in the insulation, then the megohmmeter will show low resistance. This is a fairly accurate way. Naturally, be careful when working with high voltage. Good Luck,sincerely.

  • @oddsman01
    @oddsman01 Před rokem +1

    An ignition circuit on your car produces between 30-40KV. It’s annoying when you’re zapped by one, but not that bad. A zap from static electricity is usually around 5KV. It’s not the voltage that does the damage. It’s current.

  • @matiasdimaurizio
    @matiasdimaurizio Před 2 měsíci

    Es normal ese ruido a chispa que larga el megohmetro?

  • @virgiliomaceda5337
    @virgiliomaceda5337 Před 2 měsíci

    do you have a copy of calibration certicate, can i get a copy?

  • @ToBeDefined85
    @ToBeDefined85 Před 2 lety +1

    I don't understand the difference in the "Multiple points of failure" test. Both multimeter and insulation tester detect continuity. What is the difference?

    • @AnotherMaker
      @AnotherMaker  Před 2 lety

      it is possible that a "normal" continuity test will tell you if something is shorted because it doesn't have enough current or a high enough voltage to detect the short.

    • @1I2am3Dani4
      @1I2am3Dani4 Před 11 měsíci

      Your multimeter tests continuity with a few volts and pretty much no current which won't reveal any issues you might experience under actual live conditions (where your voltage might be anything from 110V up to 400V depending on your country and grid).

  • @rpmi-1640
    @rpmi-1640 Před 6 měsíci

    How would you replicate the water tray experiment in the real world, say an outdoors cable has snagged and ends up surround by moisture collected in the conduit. Would you stick the ground probe on a nearby ground terminal of straight into the soil? Would you then expect to get way less than 5.5 GOhm?

    • @inothome
      @inothome Před 2 měsíci

      Connect it to the conduit, if metal and then one of the cable leads. Or the ground lead in the cable run, or between the neutral and line with the devices disconnected. Anything less than 2M Ohm may cause problems. Anything much lower than that will cause problems.

  • @bl00dyglass
    @bl00dyglass Před 2 lety

    Is the Insulation Resistance tester emitting DC or AC voltage?

  • @MaN2Mega
    @MaN2Mega Před rokem

    Is this megger appropriate for the automotive 12V system ?

    • @AnotherMaker
      @AnotherMaker  Před rokem

      Yes, I don't see why not.

    • @MaN2Mega
      @MaN2Mega Před rokem

      @@AnotherMaker Well I'm not fully sure how they function, my fear is that a megger made for more robust wires, 230V AC here in Europe maybe would damage wires in the 12V system?

    • @petermichaelgreen
      @petermichaelgreen Před 3 měsíci

      Its' fine for testing wiring but be careful nothing is connected first.

    • @georgilafchiyski2052
      @georgilafchiyski2052 Před 3 dny

      I testing diesel (piezo, etc ) injectors in automotive diagnostics because specially with misfire and if u use multimeter resistance is ok but when I use this 501 insulation tester LOL shorted not fully injector .​@@MaN2Mega

  • @Dog-whisperer7494
    @Dog-whisperer7494 Před rokem +1

    You test the meter is working correctly by pressing the test button test leads apart you should get a zero reading short the lead together press test you should get full scale deflection. This tells you the meter is working correctly .

    • @AnotherMaker
      @AnotherMaker  Před rokem +1

      Good tip. Thank you!

    • @Dog-whisperer7494
      @Dog-whisperer7494 Před rokem

      @@AnotherMaker those UNI-T test are fantastic for learners and apprentices. Just starting out . Once they have experience they can upgrade to one of the big brands like fluke

    • @repa77777
      @repa77777 Před 2 měsíci

      you mean the opoosite??

  • @carlosgarcialalicata
    @carlosgarcialalicata Před 2 lety

    Does that little device really can produce 1000V? isn't that dangerous? What would it do if you connect a varistor in there? :)

    • @AnotherMaker
      @AnotherMaker  Před 2 lety

      I think it really does 1000v. The varistor sounds like an interesting experiment.

    • @stevenspmd
      @stevenspmd Před 2 lety

      Even the much cheaper BM500A will do 1000V; "TheHWCave" has a review/safety discussion of that one.

    • @procrastinator1842
      @procrastinator1842 Před rokem

      It's 1000v at about 1mA of current. So very little energy, but enought to give you a surprise shock.

    • @brentfixesstuff
      @brentfixesstuff Před rokem

      It's 1000v DC not AC so it makes a difference.

  • @Dog-whisperer7494
    @Dog-whisperer7494 Před rokem

    The uni-t 501 reads megger ohms on the 250v and 500v range , not gig ohms, the minimum acceptable value for insulation resistance is >1 magohm ie greater than 1 Megohm the maximum that tester can display is ol = over limit or l = over limit ie full scale deflection. On new installations we expect to see full scale deflection .

    • @AnotherMaker
      @AnotherMaker  Před rokem +1

      You seem to know a lot about this. I really appreciate the tips.

    • @Dog-whisperer7494
      @Dog-whisperer7494 Před rokem

      @@AnotherMaker yes I have been an electrician for a little over thirty years . I am in UK 🇬🇧

  • @theshuff
    @theshuff Před rokem

    dont know how you are supposed to test isolation in your country, but in france, isolation tests are never done between live and neutral wires. Tests are only done between neutral and earth, live and earth and finally between live wires in industrial electrical setup.

    • @AnotherMaker
      @AnotherMaker  Před rokem

      What's the downside of testing between live and neutral?

    • @theshuff
      @theshuff Před rokem +1

      ​@@AnotherMaker in "real world" you have terminal components plugged between live and neutral (computer, light bulb...). it's not advisable to inject 500+vdc even with low current. Only revelent test that should be done between live and neutral is a short circuit test with ohm multimeter.

  • @alexstone691
    @alexstone691 Před 2 lety

    5:04 It says >5.50G ohms