Modeling and Analysis of G+3 Building | Complete Etabs Tutorial | Learn for free(No experience reqd)

Sdílet
Vložit
  • čas přidán 8. 09. 2024
  • This video will show you how to model and analyze G+3 residential buildings in ETABS according to the Indian standard code.
    Do like and subscribe to us.
    LinkedIn: / parash-joshi-464a6b1a4
    Instagram: / civil_const
    Facebook: / civilconstn

Komentáře • 99

  • @samcapital9047
    @samcapital9047 Před 6 měsíci +1

    I like the way you described everything....detailed and the best part music is slow and does not affect the narration. Well done.

  • @Cdramab
    @Cdramab Před 2 lety +1

    This video is very informative with simple explanation and really appreciated sir. I'm watching all the videos for complete building design. Thank you sir.

    • @civilconst
      @civilconst  Před 2 lety +1

      Cheers

    • @Cdramab
      @Cdramab Před 2 lety

      @@civilconst sir, I got one doubt to be cleared. In some tutorials, i found that the beams with exterior columns are align with the exterior face of the column. But it didn't happen in your tutorials. So, which one do I hav to follow, sir?. Thank you.

  • @anishpandit8587
    @anishpandit8587 Před 4 lety +1

    Ka bata ho hajur ekdam babbal lagyo malai ta ...yesto videos ajai banaunu yrr dherai ramro ..😍😍

    • @civilconst
      @civilconst  Před 4 lety

      Thanks hajur. Bistarai aaucha hai sir

  • @claudebai725
    @claudebai725 Před 8 měsíci

    thanks for posting a etabs video that speaks proper english.

  • @robertiravonga559
    @robertiravonga559 Před rokem

    Very comprehensive and well-explained. This is probably the best I've seen.

  • @manojtimilsina6789
    @manojtimilsina6789 Před měsícem

    As there is the secondary beam in staircase side, so we have to give the load as per the absolute distance upto the the secondary beam?

  • @GauravKumar-uh8uy
    @GauravKumar-uh8uy Před 4 lety +1

    Great. U made it very easy

  • @MG-ny1ue
    @MG-ny1ue Před 2 lety +1

    Nice informative vedio ❤❤❤

  • @user-qc6vf6ze5e
    @user-qc6vf6ze5e Před 7 měsíci

    Thanks alot 🙏.. well explained

  • @MG-ny1ue
    @MG-ny1ue Před 2 lety +1

    ❤❤

  • @bikashranjansethi6811
    @bikashranjansethi6811 Před 11 měsíci

    Why u designed slab to be shell thin... could u please explain??

  • @ganeshnani7525
    @ganeshnani7525 Před 2 lety

    Sir, thanks for the knowledge that you have provided in this vedio, I have a doubt that how the sunken slabs and low roofs are designed, I would be thankful that and I hope that it will be useful for many of us.....

  • @samikshathapa912
    @samikshathapa912 Před 3 lety

    Great work sir 👍very informative 😊

    • @Catloverss95
      @Catloverss95 Před 2 lety

      Structural analysis and finite element method basics
      czcams.com/channels/fZBo0T5G0W_rGYHAXfYIRw.htmlvideos

  • @civilideas1925
    @civilideas1925 Před 2 lety

    👍🏻👍🏻

  • @melkamuataro7858
    @melkamuataro7858 Před rokem

    Excellent

  • @Sankalp-Art-Work
    @Sankalp-Art-Work Před 3 lety +1

    What about stiffness modification for column and beam ..
    Generally we take it as .70 for column and .35 for beam

    • @civilconst
      @civilconst  Před 3 lety

      I have made a video regarding it. You can find it.

  • @saqibahmedkhan9210
    @saqibahmedkhan9210 Před 2 lety

    Dear Sir good morning please make a vedio having circular beams and explain how it can be made in ETABS SOFTWARE

  • @rajankhadka7371
    @rajankhadka7371 Před 3 lety +1

    Great video. Is it also necessary to have 10% difference in fundamental time period of building in prinicipal plan direction?

    • @civilconst
      @civilconst  Před 3 lety

      Tyo 10% chai type of combination select garna ho, if two consecutive modes are closely spaced ( frequency within 10% of each other) stress resultants for these two modes are added by absolute values. For such modes, if the SRSS combination method is used, the modal action effects from any modes shall be first combined by direct summation ignoring any sign. Hence this method is valid for both closely spaced and ‘not closely spaced’ modes. NBC 105:2020 le chai 15% rakheko cha.

  • @ronnie9096
    @ronnie9096 Před 2 lety +1

    Well done, appreciate your effort. You are taking 1st floor beam as ground floor beam. As per your architectural and etabs model drawing ground/grade/plinth beam is at level zero (0). But you haven't drawn the beam which will sustain/carry wall load from the above. The base of the footing is at level -1.45m. So there is a short column. Won't you consider this for subsequent foundation design including surcharge & applicable load. I suppose if meshing is set to none by default then program won't mesh the slabs/elements and frame joint etc. Plz clarify

    • @civilconst
      @civilconst  Před 2 lety

      Since the plinth beam rests on ground so nominal rebar will be sufficient so i haven’t modelled it. Similarly if the builidng doesn’t have basement then it is not neccessary to draw column below ground level. Short column arises if the effective height of column in respective floor is different. In our case it is 1.45 m for all columns so not to worry about it.

    • @ronnie9096
      @ronnie9096 Před 2 lety

      @@civilconst but you cant call 1F beam as GF beam. By short column, I mean short column effect. Since all the column below is at 1.45m, not to worry as per your saying. and regarding meshing of element and frame joint, you haven't answered my question. Do we need to mesh or not? does etabs auto mesh by default. thanks once again.

  • @engrxiddig
    @engrxiddig Před 2 lety

    Thanks you are helped me

  • @IrfanShaikh-SE
    @IrfanShaikh-SE Před 3 lety

    Please make a video on detailing I mean how to provide bars in column beam and slab. Please make video on this I really like your videos.

  • @bivekgosai1951
    @bivekgosai1951 Před rokem

    sir what about the irregular floor plan ?? How to draw its grid??

  • @MG-ny1ue
    @MG-ny1ue Před 2 lety +1

    Please upload vedio about detailing

  • @adamhiwan1788
    @adamhiwan1788 Před 2 lety

    Sir can you make structure to be check like design.

  • @prabalkhakurel6901
    @prabalkhakurel6901 Před 2 lety

    Great video , sir can you share the link of the video where u have explained more about eccentricity’s calculation? And also , what if the eccentricity calculated is more than the permissible? What shall we do then?

    • @civilconst
      @civilconst  Před 2 lety +1

      czcams.com/video/dRfezpjJdXA/video.html
      Check at 12:00 minutes

    • @prabalkhakurel6901
      @prabalkhakurel6901 Před 2 lety

      @@civilconst sir if my eccentricity is more than 5% , then I need to add the eccentricity as per formula in the code , to the eccentricity part at load pattern while defining the lateral load???

  • @sujanjoshi54
    @sujanjoshi54 Před 3 lety +1

    In ur video the time period in etabs is greater than calculated by 44 % but in my work, the time period in etabs is less than calculated by 7% . What is the problem and how to fix it.

    • @sujanjoshi54
      @sujanjoshi54 Před 3 lety +1

      There was a problem in assidning the mass source, and i rectified this mistake . Now the time period is greater than calculated- (.075*ht^.75) by 68%. Is it ok. If not, any remedies??

    • @civilconst
      @civilconst  Před 3 lety

      May be your building is less stiffer. Check with greater column size . Should be fine though with that value. Check other modal information as well.

  • @dipeshsingh351
    @dipeshsingh351 Před 2 lety

    Great video sir😍😍
    Sir iam final year student nd making project on mono column building.can u make video on design nd analysis of mono column multi story building in etab??
    yas bata malai dherai help milxa nd i request to send me excel file nd etab file for reference

  • @selflove4273
    @selflove4273 Před 3 lety

    Sir am new to ur channel and subscribed,nice explanation,is this design as per reality sir, kindly reply asap, thank you

    • @civilconst
      @civilconst  Před 3 lety +1

      Thank you for joining us.
      Yes it is as per real practise.

  • @nadeem314
    @nadeem314 Před 3 lety

    Sir how to assign lift loads, water pressure and soil pressure load??
    Sir plzz make a video on these load patterns🙏🙏🙏🙏

    • @civilconst
      @civilconst  Před 3 lety

      Hey there.
      Our next video will cover that for sure.
      Thanks. Do subscribe

    • @nadeem314
      @nadeem314 Před 3 lety

      Thank you sir🙏

    • @nadeem314
      @nadeem314 Před 3 lety

      @@civilconst thank you sir🙏

  • @trailers6730
    @trailers6730 Před 3 lety

    Sit... What is meaning of mass participation ratio....

    • @civilconst
      @civilconst  Před 3 lety

      In simple terms we can say percentage of mass participating during seismic motion

  • @squarespace3003
    @squarespace3003 Před 3 lety

    Sir it is very helpful
    But in my etabs for all columns it's showing same area of steel i.e 0.80% of steel for column and 0.22%of steel for beams please help

    • @civilconst
      @civilconst  Před 3 lety

      Check your load combination considered for design

  • @visakhachalisey971
    @visakhachalisey971 Před 2 lety

    Can you tell me how to rectify the torsional issue if the Ux and Uy of mode 1 and mode 2 does not exceed 40%??

    • @civilconst
      @civilconst  Před 2 lety

      Increase stiffness of building in that particular direction where mass participation is less.

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 Před 2 lety +1

    For external wall load why thickness 0.11 only considered?

    • @civilconst
      @civilconst  Před 2 lety

      It's not mandatory to provide 0.23 m wall for external case. depends on architecture plan.

  • @tsheringyeltshen
    @tsheringyeltshen Před rokem

    Why plinth beam is not modelled sir?

    • @civilconst
      @civilconst  Před rokem +1

      Seismic height is considered from top of plinth beam, so nominal reinforcement is sufficient.

  • @bibeknepal2135
    @bibeknepal2135 Před 2 lety

    sir residential building ko lagi NBC ma dherai reinforcement aayuxa ke IS code anusar garda ? i got more in IS code in column

    • @civilconst
      @civilconst  Před 2 lety

      Aaaunnu parne NBC ma ho .

    • @bibeknepal2135
      @bibeknepal2135 Před 2 lety

      @@civilconst but sir in NBC we have seismic coefficient of around 0.131 for low rise building and have the load combination of DL+lamda LL+ or - EQ load while in IS code for same height seismic coefficient will be 0.09 and load combination with 1.5 factor on earthquake load which makes total load 0.09*1.5=0.135 which is greater than 0.131 which was obtained from IS . so how come it can be greater? is my question

  • @rupeshkumarpajiyar8252

    Etabs 2016 ma B/C capacity ratio kam hunxa soo tei aanusar reinforcement lidaa safe hoo kii nae

    • @civilconst
      @civilconst  Před 3 lety

      Ah milcha. naya code not implemented yet.

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 Před 2 lety

    My diaphragms diagram is coming different for different storey. Why?

  • @bedazzledblue7489
    @bedazzledblue7489 Před 6 měsíci

    How can we hide diaphram??

    • @civilconst
      @civilconst  Před 6 měsíci

      Ctrl + w, uncheck show diaphragm

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 Před 2 lety +1

    Time period came 79% what to do? Is it safe?

    • @civilconst
      @civilconst  Před 2 lety

      That will depend on stiffness of your building as well. It's not mandatory to 50%. Its just for usual residential building with general loadings.

  • @AtulEngineer
    @AtulEngineer Před rokem

    Session is informative but loud background music is annoying.

  • @cameronvan6875
    @cameronvan6875 Před 2 lety

    where was the slab design and reinforcement detailed?

  • @dipeshsingh351
    @dipeshsingh351 Před 2 lety

    sir mero max story displacement nd max story drift calculated vanda badhi aai rahe xa etab ma tyslai kasari reduce garne ??
    plzz reply if any one know

  • @unmeshshakya3194
    @unmeshshakya3194 Před 3 lety

    Why there is no releases for the secondary beam???

    • @civilconst
      @civilconst  Před 3 lety

      Considering construction practise

    • @rupeshkumarpajiyar8252
      @rupeshkumarpajiyar8252 Před 3 lety

      @@civilconst So can u leave assigning releases to secondary beam,Wonot it create any problem???

    • @ansariabid5623
      @ansariabid5623 Před 3 lety +3

      @@rupeshkumarpajiyar8252 if u don't release than there is no problem, because just u will get the -ve moment at the support, and the percentage of steel will increase so ur cost will increase. And if u release the moment than there will be no negative moment and the beam will act as simply supported. And percentage of steel will be less.

    • @civilconst
      @civilconst  Před 3 lety

      Bravo.

    • @sumansubedi7319
      @sumansubedi7319 Před 3 lety

      @@ansariabid5623 this is very relative.we get higher bending moment in secondary beam when designed as simply supported condition , so size of secondary beam increases and rebar in secondary beam increases. so in terms of cost I guess there is not much difference in both cases. One compensates the other either releasing or not releasing.

  • @JagdishDive123
    @JagdishDive123 Před 4 lety

    needed in 480p

  • @Innotutorial
    @Innotutorial Před 3 lety +1

    please sir can i get the autocad file?

    • @Catloverss95
      @Catloverss95 Před 2 lety

      Structural analysis and finite element method basics
      czcams.com/channels/fZBo0T5G0W_rGYHAXfYIRw.htmlvideos

    • @Innotutorial
      @Innotutorial Před 2 lety

      @@Catloverss95 Thank you Sir🙏

  • @roshanadhikari9852
    @roshanadhikari9852 Před 3 lety

    Babaal

  • @ajith2684
    @ajith2684 Před rokem

    Sir can i get autocad file