Module Removal -- ControlLogix
Komentáře • 29
Další v pořadí
Automatické přehrávání
How to Wire a PLC Control Panel Like a ProBee Automation
zhlédnutí 93K
ControlLogix Hardware Walk ThroughWayne Welk
zhlédnutí 8K
Allen Bradley PLC rack discussion with all modules installed. PLC Logix 5561 family CPU and modulesELECTRICAL AND INSTRUMENTATION TRAINING
zhlédnutí 685
Comfortable 🤣 #comedy #funnyMicky Makeover
zhlédnutí 16M
This is the Biggest SAW in the World 😱🪚 #camping #survival #bushcraft #outdoors #lifehackMarusya Outdoors
zhlédnutí 17M
VOLO VIA dallo staggio (elemento PROIBITO)😂🚀Sophialand
zhlédnutí 19M
How to assemble a CLogix chassis and modulesAB PLC Test Bench
zhlédnutí 2,5K
ControlLogix 5580 1756-L82E Ethernet config and Firmware FlashSY P HOANG
zhlédnutí 5K
Wiring arm for 1756-IF16 in mA modeAB PLC Test Bench
zhlédnutí 4K
Troubleshooting a PLC OutputKletteTech
zhlédnutí 43K
HOW TO CALIBRATE THE PENUMATIC FISHER PRESSURE CONTROLLER MODEL 4160 AND MODEL: C1Issam Al-Attas
zhlédnutí 1,8K
PLC Basics: Ladder LogicThis is Automation
zhlédnutí 361K
V MÉ HLAVĚ…Attack
zhlédnutí 510K
Survive 100 Days In Nuclear Bunker, Win $500,000MrBeast
zhlédnutí 150M
VAŠE DÁVKA USPOKOJENÍ #74 😍HouseBox
zhlédnutí 383K
Co divného umíš ty? 😝Tary
zhlédnutí 228K
Why Is He Unhappy…?Alan Chikin Chow
zhlédnutí 98M
SPILLED CHOCKY MILK PRANK ON BROTHER 😂 #shortsSavage Vlogs
zhlédnutí 42M
How Countries eat spaghettiLionfield
zhlédnutí 12M
How would you react?!😳ILYA BORZOV
zhlédnutí 21M
Not gonna lie, I'm glad I watched someone else just yank the wiring assembly out before I went and had to do it myself...
Very good!
There is also a locking lever at the top of the I/O modules for locking the terminal strips onto the I/O modules. You should move the locking lever at the top of the module to the unlock position before pulling on the handle, and when you reinstall the terminal strips you should lock the terminal strips by moving the lever to the locked position.
Dedrick Broussard Good point, we don’t have the locks on. We don’t want students damaging a locked card. Thanks for the comment.
@@RDCINST Someone not in your class might have seen the video and tried to work on a PLC and damaged it if he tried to remove the terminals without unlocking them.
Dedrick Broussard I will modify the video. Thanks for the feedback!
Thanks sir...
You’re welcome!
Thank you for the video, helped me a lot.
I've a question, can we unplug a module while it's powered or we have to put the rack off first. Thank you
Nabil Ou you can do it with power on. Just make sure whatever inputs or outputs are controlled by the card are in a safe state.
@@RDCINST thanks for your feedback, I'll make sur of that.
Would you power down the whole PLC to replace a module? I have a bad RTD module and have to replace it. Allen Bradley doesn't have a power button like a Siemens PLC does. I have replaced a Siemens but not on an Allen Bradley. Thanks in Advance.
The modules are hot-swappable on the ControlLogix series. Confirm in the documentation, but you should be able the change the card out with the PLC powered up. If the PLC is controlling a live process make sure to connect to it with Studio 5000 and check the module isn’t configured to fault the controller when it is disconnected. Otherwise, if you feel more comfortable doing a shutdown, you can power off the PLC by opening in the door on the power supply and using the power switch to power it down.
@@RDCINST I appreciate the response! Thank you very much! I love your content and just subscribed. Thank you for all the info.
Mine wouldn’t connect back to the PLC after installing. The ok light was flashing
That’s too bad. Was the controller in run mode when you disconnected it? If so, the ‘Major Fault On Controller if Connection Fails When in Run Mode’ option must be checked in the module’s configuration in the RSLogix 5000 / Studio 5000 project file. To clear the fault you can do it from Studio 5000, or switch the key to PROG and the back to RUN once or twice to if you don’t have the software.
@@RDCINST nope. Just went bad
@@joew4202 I would reach out to Rockwell if the module is still on warranty. Those modules are suppose to be hot swappable.
Thank you!!
You’re welcome!
nice advices!! thanks!!
No problem! I’m glad you could make use of it!
I also want to experiment with such modules. Do you know where there is a cheap sale?
Sorry about the late reply. I would check eBay for used modules.
by powring off the PLC and removing/installing the CPU , is it going to loose its data taking in consideration that there is a backup battery inside it
abdelssami brahmi that’s right! The 1756-L61 has a backup battery for powering the memory storing the program. As long as the battery is still good, the program will not be lost if the power supply is turned off. There is a battery indicator light showing the status of the battery. If the battery is weak, a red “Bat” light will turn on.
could do you show a video on SERCO communication module ?
Sorry, I do not have a SERCO communication module to demonstrate.
@@RDCINST thanks for the reply !!!
I tried to connect you on LinkedIn.