Tekla Tips & Tricks - Numbering!

Sdílet
Vložit
  • čas přidán 28. 08. 2024

Komentáře • 14

  • @BuildingPointScandinavia

    Just discovered there's a bit of a lag in the sound. If you find that VERY annoying, there's a corrected version here: buildingpoint-scandinavia.com/blog/tekla-tips-and-tricks-numbering
    Sorry about that!😅

  • @rajeshramalingam96
    @rajeshramalingam96 Před 6 měsíci

    Very Clear Explanation. Thanks sir

    • @BuildingPointScandinavia
      @BuildingPointScandinavia  Před 6 měsíci

      Thank you, great to hear! :)
      Follow us on LinkedIn to stay up to date: www.linkedin.com/company/buildingpoint-scandinavia

  • @MirkoDeJaegher
    @MirkoDeJaegher Před měsícem

    Numbering by phase, that affects Parts and assemblies would be what many companies would need.

  • @aboraka
    @aboraka Před 5 měsíci

    all contents are really useful👌

  • @prabhaayan1651
    @prabhaayan1651 Před 4 měsíci

    Hi in Numbering if tolerance is kept 500mm means it will take same number for both the plates,what about creating drawings?

    • @BuildingPointScandinavia
      @BuildingPointScandinavia  Před měsícem

      Hi there, sorry for late reply! It's best if you contact your technical support team about this ;)

  • @ThePchua
    @ThePchua Před 10 měsíci

    How to sort also part position number by using profile?

    • @BuildingPointScandinavia
      @BuildingPointScandinavia  Před 9 měsíci

      Hi, great question! We haven't actually tried it, so we would not recommend to use that numbering convention in a project...

  • @sriharis2425
    @sriharis2425 Před rokem

    How to over come A1001 for assembly and a1001 for part drawings

    • @BuildingPointScandinavia
      @BuildingPointScandinavia  Před rokem +2

      Hello @sriharis2425 !
      I’m not sure I understand what you mean, it looks to me in your example that you want to use “A” as a Prefix and “1001” as start number on your assemblies. And “a” as Prefix for your parts. To get rid of the separator you need to change that under Options.
      If you are a BuildingPoint Scandinavia customer you may reach out to our Tekla support team! If you are in a different region, I am sure the local Tekla support can help you :)

    • @jordanhernadi2157
      @jordanhernadi2157 Před 4 měsíci

      hi, using the same prefix is highly NOT recomended; in similar case (a/A, b/B...) I used to set start number for part 1001, 2001... and for assy 101, 201 ... where prefix marks the type of structure and start number shows the different phase or level or something else in the model