My septic air pump will not turn on!

Sdílet
Vložit
  • čas přidán 11. 09. 2024

Komentáře • 33

  • @johnacord6224
    @johnacord6224 Před 17 dny +1

    Best vedio yet. All the others showed the older version. So thank you, thank you, thank you. I thought I was from another planet 😊

  • @and0uille
    @and0uille Před 10 měsíci +1

    Thank you, I had changed the Diaphragms and was puzzled at why it was not working... Fixed it in 5 minutes after watching your video!

  • @brentellender8651
    @brentellender8651 Před 4 měsíci

    Great video. I just replace my pump diaphragms but the pump still wasn't working. Watched your video and went and reset the switch and the pump works perfectly. Saved me having to buy a new pump for $400! Well done.

  • @melissaharpster3835
    @melissaharpster3835 Před 10 měsíci +1

    Thanks for your help! Knowing about the plastic safety switch just fixed my Hiblow!

  • @mcrawfordinc.1422
    @mcrawfordinc.1422 Před rokem +1

    You’re awesome. I learned something new and got my unit running after watching this.

  • @franginmhd
    @franginmhd Před 11 měsíci

    Thanks for the video, really helped me out and was about to buy a new unit but only needed to order a replacement kit👍

  • @dannydaniel623
    @dannydaniel623 Před rokem +1

    Great video and did a great job explaining everything.

  • @MrErpman
    @MrErpman Před 5 měsíci

    Mine went out and i rebuilt it using a kit. What no one told me was the "screw" on top was a breaker and i had to align the slot with the arrow. Once I did that it worked. Only took about 20 minutes.

  • @srconceptscomau
    @srconceptscomau Před 7 měsíci

    Great video, thanks

  • @Mr.PeabodyTheSkeptic
    @Mr.PeabodyTheSkeptic Před rokem

    Thanks for the help

  • @RaleighRonsClassics
    @RaleighRonsClassics Před 6 měsíci

    Any links to the safety switch and diaphragm kits? I have that exact unit.

  • @RaleighRonsClassics
    @RaleighRonsClassics Před 6 měsíci

    Maybe I missed it but model and brand you are working on in the video?

  • @kfelix2934
    @kfelix2934 Před rokem +1

    Thanks for this video , I just fix my unit but was used to the scew type. I had replaced my aerator like 3 years ago and this new unit split the diagphams. So I got 3 years out of the unit. My aerator sits under a big concrete cast shield. Do you think this is causing the hiblow80 to get two hot?
    I see other systems where the aeratopr is sitting out in the open. So I'm assuming they will run much cooler.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před rokem +1

      Test where actually done couple years ago and we sent some housing for aerators and out in the open was actually the best result followed by a open on both ends cover. None of the aerator manufacturers actually know who started the cover idea but it wasn’t a good one. On the old rotary vane units it was but in diaphragm units it’s not necessary.

  • @rosanneschillings254
    @rosanneschillings254 Před 10 měsíci +1

    Mine came on & worked for an hour or so. I took it apart again and it looked like the new diaphragms were already warping around the edges! I bought a Hiblow XP 80 instead. It is replacing the Hiblow HP 80. I don’t see where there is a place for the air tube on the XP though.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 10 měsíci

      Possible you bought a fake rebuild kit. The real ones will be engraved on the diaphragm and chamber block.

  • @letyoscarcornejo5365
    @letyoscarcornejo5365 Před 11 měsíci

    Can you provide the link of the replacement slide switch I’m trying to find it on y’all website but I can’t seem to find it

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 11 měsíci +1

      www.wholesalesepticsupply.com/products/hiblow-top-safety-switch-assembly-with-screw
      www.wholesalesepticsupply.com/products/hiblow-sw03-slide-switch
      Two different kinds of

  • @twayne62
    @twayne62 Před 7 měsíci

    The plastic screw broke on mine can i replace it with a regular screw

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 7 měsíci

      No if it broke the diaphragm is tore as well. Screw comes with the kit to fix the unit. I have yet to see a screw broke on a running unit and the diaphragm no needing to be replaced.

  • @VegasRT500
    @VegasRT500 Před rokem

    Video didnt show how to replace the magnet diaphragm.

  • @majorsounds
    @majorsounds Před rokem

    What turns the Aerator on and off? Does it stay on 24 hours a day?

    • @arnaldo35
      @arnaldo35 Před rokem

      Yep, 24 hrs unless you use a timer.

    • @majorsounds
      @majorsounds Před rokem

      @@arnaldo35 is there a video that shows how to setup with a timer?

    • @arnaldo35
      @arnaldo35 Před rokem

      @@majorsounds Just buy a wall plug timer from the hardware store and connect the pump. Bear in mind, your septic will start to smell if you don't have enough aeration.

  • @erictherrien6174
    @erictherrien6174 Před 2 lety

    Hi , i have a hiblow HP-80 that i got from you guys and it only lasted 4 years and the diaphragms ruptured so i changed them and now onces it's fixed (with new diaphangms) the pump will stop after two hours of running and the core is blazzing hot. can you help me out ..Thanks

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 2 lety

      Where did you get the kit. If it wasn’t from a hiblow dealer you might have got a fake kit. You could need a new diffuser as well.

    • @arnaldo35
      @arnaldo35 Před rokem +1

      I tried the cheap Chinese diaphragms from ebay and they lasted about 3 days. The rubber goes rock-hard and it doesn't pump air causing the pump to overheat. I replaced them with genuine diaphragms and it worked for about another week. Then the actuator rod broke in half, no doubt from the stress caused by the inflexible rubber in the cheap diaphragms. The genuine parts are a total rip off, but they are the only ones that use epdm rubber.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před rokem

      @@arnaldo35 the Chinese ones are epdm it’s just that there is thousands of different kinds of epdm. The units run 24/7 and flex 30 times a second that’s 946,080,000 a year that’s roughly 2-4 billion times in there average life. Just cleaning the air filter and sometimes not even that. Cheaper than a moth on city sewer so it all depends on how you look at it.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před rokem

      @@arnaldo35 the Chinese ones probably ruined the unit.