Driveway, House & Roof Wash- AR45 Gas Pump Blasting

Sdílet
Vložit
  • čas přidán 6. 09. 2024
  • This is an annual customer and we did the whole package. The AR45 gas pump put in some work with the 12 volt for the roof wash.
    Check out our channel
    / @allproexteriorservice...

Komentáře • 11

  • @hamidmalik3538
    @hamidmalik3538 Před 5 měsíci +1

    Sup Buddy! Good to see ya out here getting it!

  • @davidlicht4418
    @davidlicht4418 Před 5 měsíci +2

    So don’t you use much more sh using the AR 45 then downstream

  • @justinsigman6795
    @justinsigman6795 Před 5 měsíci +1

    Hey big dog love your videos.. I have a question. I’m curious if you have ran a 24 volt for washing before.. and if you think it would have enough flow to do the rinsing side as well..just to get started of course only untill I get a pressure washer later for rinsing.

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  Před 5 měsíci +1

      The 24 volt pump should give you more volume. I would maybe look into the 7 GPM 12 volt pump & save the additional money for a pressure washer. Once you get the pressure washer then you can downstream which should be more efficient. Thanks

  • @JC-ft5or
    @JC-ft5or Před 4 měsíci +1

    Great content! I’m getting my SW system tomorrow with the AR45. Do you always wet brick with water before you use SH? Will the SH damage the brick if you don’t pre wet? Also, what percent of SH do you use for a regular house wash?

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  Před 4 měsíci

      I wet the brick because I find it easier to rinse the SH off. It should not harm the brick. I am using about 1% for a house wash. Thanks

  • @kolbymeyer27
    @kolbymeyer27 Před 5 měsíci +1

    On my ar i feel like im not quite getting what my valves say i am. Im using a regular ball valve for water which stays open but my bleach is an asahi metering valve. Im not really able to pull bleach until a bump under 50%. Im stumped as to what I'm doing wrong.

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  Před 5 měsíci

      I started with a regular ball valve on the water side. I ended up changing the water valve to an Asahi metering valve and it is way more accurate. The regular ball valve will flow more than the metering valve. Hope this helps. Thanks

    • @kolbymeyer27
      @kolbymeyer27 Před 5 měsíci

      @@allproexteriorservicesllc5338 Now that you mention that i was wondering about the cut vs uncut. That’s probably a substantial difference.