UTL SMU pwm & SMARTEN prime+ mppt Solar Charge Controller | Which Is Best For You
Vložit
- čas přidán 5. 09. 2024
- I just want everyone to know about this 2 solar hybrid controller. Basic feature is almost the same but PWM & MPPT Both are different effective technology work with Green energy. UTL SMU or you can say solar management unit comes in 12/24 volt variant & 20/40 amp setup. With a low Bypass efficiency i prefer for low budget solar setup, with 40 amp 12 volt capacity 600 to 800 watt panel can be connected & in 24 volt 1000 easily can be connected.
For SMARTEN same you can say but it comes with a 30 amp 12/24 volt, in cost almost double from UTL. It comes with MPPT technology that can increase solar efficiency 15% to 20%. But in 12 volt system Bypass volt it require 25, in my thinking is too much because 12 volt solar never provide more than 19+ volt in pick.
Without knowing buying is too much harassment for everyone,
Be careful
#solar_charge_controller
#solar_project
#solar
#utl_smu
#smarten
#charge_controller
#green_energy
#home_solar_project
#pwm_mppt
for home solar project-- • 500 Watt Solar Energy ...
&
• Micro Cracks in Solar ...
UTL SMU setup-- • UTL SMU | Best Hybrid ...
&
• UTL SMU Complete Insta...
SMARTEN PRIME+ NEEDS -- • 24 Volt Solar Panel Ca...
&
• Loom Solar 375 Watt Mo...
ZUNSOLAR & LOOMSOLAR PROJECT -- • Loom Solar 375 Watt Mo...
&
• Loom Solar 375 Watt Te...
&
• 500 Watt Solar Energy ...
&
• ZunSolar 12v 165 watt ...
FOR DC TO DC SOLAR PROJECT -- • Solar Panels For Home ...
ENJOY .....
Muje 200w soler penel use karna hai konsa smu karidu
Very useful research information
Thanks.
Best knowledge provider.........
Thank you so much my dear friend, I just want to share my knowledge with everyone.
Real and practical experience shared by you, thanks
Bro, since you have this equipment, can you make a video with voltage and current measurements. I am trying to understand when does it cutoff mains supply to inverter. For both utl and smarten. Thanks in advance.
Ok, in next I will..👍
@@addriexperiments 😊
Your information needs correction. The PWM drops the stem voltage to the battery level under utilisation of the solar output. MPPT converts the total power generated to the battery voltage adjustment is made with ampere. Cannot compare the two. Both are different technologies. you can connect 24 V panels using MPPT to a 12 volt battery but cannot do that using PWM.
Please watch my videos carefully so you can understand the same.
But thanks for elaborate 👍👍
if you use 12 volt panel then there is no difference in power output mppt gives more power when solar panel 24 volt..
@@ArunKumar-jk6rr yes that is true but it definitely effect in bypass.
You can do that using pwm too...
aap ne yeh nahi batya ke battry kitni lagegi ? Samartan ke Charj Cantrolar ko 24 volt ke penal to laga diye lekin battry kitne volt ki lagegi. UTL ke SMW ki to mujhe jankari hai. lekin 24 volt ke penal ke lie Battry bhi 24 volt chahie aue inverter bhi 24 volt chahie. agar 12 volt ke penal lagane hai to 12 volt ki battry aur 12 volt ke 500 watt tak laga sakte ho aur Inverter bhi wohi chalega.
How much solar you have connected with 24 volt setup?
Sir,
i'm having loom solar 180 watt X 3 solar panels, with luminous nxg 1100. I think it charges battery with max 15A, so is my rest of the power from panels is getting waste? or does it get utilized when load is greater than 15A(including battery charging)?
my 2nd question is can I shift to smarten mppt prime+? or smarten superb 1100? as I have 3 panels, does 20Voc works well with mppt to charge a 12v battery? I cant add one more panel to make it 40volts in series.
Thankyou
What SMU shall be use for 25voc solar panel.. As Pwm doesn't support over 22.5voc.. The new solar panels (190v-200v Or above) are coming with higher voc but the pwm SMU can't be used. Please guide considering that it should be budget friendly. Thanks
Use 24 volt setup with utl,
@@addriexperiments thanks bro, however with 24v setup, the voc will increase to 50voc (25+25) from 2 panels and the max utl SMU supports is 49.
Never use pwm smu for higher wattage....too much wastage of energy.
bhai aap bahut achi video banate ho mene subscribe kr liya
bhai ye smu battery charg hone ke bad solar ki supply rok dega...
Thank you so much,
Yes if you use it only for charging battery from solar than. Or like a hybrid system it bypass in 15 volt+6amp
Kindly compare Msv mppt with other mppt bcoz Msv comes with low cost which is very useful for middle class people
aapne 24 volt ke kitne solar laga ke check kiye hai smu me mere pass three panel hai 300 watt 40 volt ke smu par lga sakta hu 150 Ah luminous battery full ho jayegi
I have tasted smarten 24 volt to 12 volt system, but never tested with utl smu.
UTL pwm vs UTL rMppt, which will be beter brother? Will UTL rMppt bypass the electricity line when pv volt above 15 volt?
Plz reply, Love from Bangladesh.. 🎉❤
Bhaisahab Us panel ki company bata dijiye jo 100 watt panel se 8 amp generate karta ho
😄😄😄 😄 there is no company, 100 watt panel can produce 5+ amp max.
@@addriexperiments maine isliye pucha tha ki aap galti se 100 watt ke panel se 8 amp bol gaye the
@@buildwealth2972 o that on is by mistake. It's just a example nothing else.
🙏राम राम सर जी
7.5 HP शक्ति कंपनी सोलर सिंचाई वास्ते खेत मे लगा है
जिसमे 20 सोलर पेनल 340 w के है
जिनकी voc 46.03 है
कृपया जानकारी दे की इससे ढाणी (घर) मे कैसे चलाये
ढाणी का लोढ:- 3 पंखे, फरिज 175ली, वासिंग मशीन, पानी मोटर 1/2hp , light वाला चुला,
इस लोढ वास्ते कोनसी कम्पनी का PWM या MPPT लगाये
कृपया जानकारी दे 🙏🏽🙏🏽🙏🏽🙏🏽🙏🏽🙏🏽🙏🏽
Sir mere pas utl charging controller he aur 37.45 voc bale panele laga saku ampier 15 he
O yes, use 24 volt Setup 👍
Smarten ka 33volt dc pover nikal ta he to bettry kharab hoti he.
Yes but you have to use the power in same time
मेरे पास ac इन्वर्टर है ।लेकिन उस बैटरी को सोलर द्वारा चार्ज करना चाहता हू क्या क्या यंत्र की जरूरत है । पूरी जानकारी दीजिए।
Only English please..
Hi sir , what if grid electricity supply is gone at night will inverter automatically on
O yes 👍
@@addriexperiments Thank you
Sir mere pass 24 volt ke panel hain 250watt ke toh kya isko mai 20 ampere ki setting pe UTL smu ke saath use kar sakta hun single battery ko charge krne ke liye jo 180ah ki hai
No, utl is not comfortable with 24 volt to 12 volt setup. You can use smarten for this easily.
As you say how to connect 24V panel to 12V inverter system can you explain.
Please check my previous videos, all content you need is already there...
@@addriexperiments Can you provide link pls
@@sureshlingabathinalink for you
czcams.com/video/zSt5jYryn7s/video.html
Luminous 1100 NXG inverter hai 330 wat ka solar panel hai to ismein kaun sa solar charge controller Lena chahie
Aur kitne panel lag sakte hain
Use smarten, but in 24 volt input & 12 volt output use only one 330 solar..
Sir mera smarten prime plus controller kabhi kabhi mains on ho k bhi mains disconnect dikhata hai to muze har baar charge controller ka battery connection disconnect kar k vapas connect karna padta hai. Kya problem ho sakta hai
UTL ka smu mppt ushka ek video banaow
Okay 👍
Super video sir...🙏🙏
Thanks 😊
Bro utl smu pr 24 volt 330 watt 3 panal parlar me 12 volt inverter pr lga sake hai plz reply
Utl don't support this process but smarten can. In smarten you can easily complete your requirements.
Sir mere pas 300watt ka ek panel aur 12volt ka batry hai . Utl ka smu 122440 chalega kya?
Do you have 300 watt 24 volt panel?
If yes then please go for smarten because in utl 24 volt input means you have to connect 24 volt battery.
Sir mere pass 320 watt ka tata ka panel h or 180ah ki battery h sir usme kon ca system lagaye
"Main present bypass on " iska matlab kaya hay?
It means it cuts of the electricity when required volt+amp is produced by solar panel.
Amps to test kiye hi nahi... compare sirf bahar se kar diye
Please check my previous video's.
& My topic is different.......
Hallo sir hamare yahan long time bijali cut rahata hai कौन सा चार्ज कंट्रोलर यूज़ करें से हमारा नाइट के लिए battery backup safe rahe
You can use mppt charge controller and minimum 2 150 solar. It will help you
Utl SMU kaisa rahega
@@RahulSingh-on7jg utl smu is very good and useful to use, but it's a pwm based system so power boost never happened.
@@addriexperiments thanks
A MPPt se direct dc load chalpaiga??
No,
UTL smu 40A vs zunsoler smu 40A which is best
525watt का 12 volt poly पैनल्स सिस्टम साफ मौसम में अधिकतम कितने amp देता है
Only battry charge ke liya utl ka simple charge controler chalega kya sir ?
O yes, you can use it like a normal solar charge controller.
भाई अब शायद तो यूटीएल ने भी एम पी पी टी में चार्ज कन्ट्रोलर दे दिया है।
Bhai utl mppt controlar me bahut si kamiya hai. pl. Use na le. Aur na hi kisi ko lene ki salah de.
UTL smu ke sat 12v 190*3 =570watt mono solar panel laga sakte hai?
Because 12v main 500 watt limitation hai...main total 500watt ke mono solar system lagbana chata hu .....please tell me how to arrange 500wart solar panel.... thank you.....👍👍
40 amp is limitation. In that case 190 watt panel can produce 9 amp, so you can attach 4- 190+ 1- 100 watt panel approx 40 amp. No issues....
If any panel able to provide 9+ amp in company description, remember 8+ max it can give us. So no problems
@@addriexperiments 40A limitation toh hai lekin 12v 500watt tak hum solar panel laga sakte hai...aisa company ka specification mention hai...
Yes I know, but as per system says you can do it.
I already tried it and support the system normally
@@addriexperiments thank you so much for this information...
Dude .. I have 1800 (180*10) panel setup.. Smarten 50amp mppt..150ah 2 battery... Please let me know how to setup 180 ..10 panel (22voc and 9amp)..how many in series and parell
Make 180×5 In series , it can produce approx 9+amp and 40+ volt. So in 2 same setup 5+5 parallel. It can produce enough.
@@addriexperiments thanks a ton..
I have setup as you suggested ..getting high pv voltage shutdown message
Panel is more...make 3 series string and connect all in parallel....you will get maximum benefit...keep one panel in spare.
@@addriexperiments 5 panels in series produces about 110v voc,which is beyond limit.
Battery full hone k baad solar se directly load chalta hai kya
मैं 10 पैनल वाला से बोर चलाता हु । उसमे मुझे घर के लिए लाईट उपयोग करना चाहता हु उसके लिए क्या करना पड़ेगा।
क्या इसपर 220वोलट के 2पैनल और 230 वोल्ट के 2कुल 4पैनल जोड़ें जा सकते हैं ।
Yes you can contact 24 volt panel different watt doesn't matter. If volt inbetween 25 to 44 smarten can perform like a 12 volt setup.
@@addriexperiments ओके । धन्यवाद।
क्या UTL SMU और समारटेन दोनों मैं भी यह पैनल एक बैटरी के साथ लगाये जा सकते हैं । किसी ने बताया है कि UTL में 24वोलट के पैनल लगाते हैं तो 2बैटरी लगानी पड़ेगी । कृपया स्पष्ट करने का कष्ट करें कि क्या ये पैनल एक बैटरी पर चलाएं जा सकते हैं ।
@@navkishore2665 utl have a major issues in this process, if input volt 24 then you have to connect 24 volt battery. But In smarten input 25-44 so 12 volt battery will handle properly.
सर 380 वाट का पांच पैनल लगाया हूं। 24 बोल्ट स्मॉर्टन का 12/24/50 एम्पीयर वाला चार्ज कंटोलेर लिया हूं । बैट्री चार्ज नही कर रहा केया करे।
dono ko test karo same solar panel use karke aur dikhao ki kon kitna power generate karke battery ko de raha hay
Smarten can make 15% more than utl and there is no doubt about it. Because it's a mppt type charge controller. But in 12 volt system some issues you have to compromise. Please watch carefully I have explained.
In next video I will definitely clarify more.
Utl ka 40ah smu charge controlar kaha sa milaga
You can buy online from Flipkart or Amazon.
175 wat ka solar panel tu baypass Karega sir utl
O yes it can 👍
Kya sir utl par hame shirf dc sistym chalana he to kya kare
No issues, just don't connect inverter. utl works like a normal solar charge controller, so no problem about that 👍
Nice explain ❤️❤️
भाई 200watt ke 12v मे 4 पैनल लगा सकते है। utl मे?
Hello bro kya hum ismai bifacial panel 440 laga sakta hai
Yes you can 👍
Hello sar Mera pass smarten Ka prime puls hai mere pass 150 watt ke 3 panel hai ose me 24 volt par Kar Sakta hu sirsis me
Batauo na sar like Kar rhay ho
3----48v ho jayege
@@deepakmovieskichha agar 150 watt panel aur ek Dal Tu to chal jayga
@@deepakmovieskichha batauo na sar ji
एक पैनल और लेना पड़ेगा । 2-2 की सीरीज के लिए।
14.5v cutout kaise set kare solar charger se grid nahi hai
Microtek का DG900 inverter और 150ah बैटरी है
अब 160ah की solar livfast battery and livfast ke 180watt ke pennal लगवाना है और गाँव पर वहाँ अक्सर 2 या तीन महीने कोई नही रहता है तो grid को bypass करके सीधे solar se charge कैसे किया जा सकता है🙏
Please type in English but Hindi wordings,
I cannot understand Hindi alphabet.
Utl smu me 165w ke kitne panal laga sakte he.
5 max,
Isme 165 ka kitna pannal laga sakte hai dukan wale tin bata rahe the
You can connect 165×5 panel easily.
Please subscribe for more information about solar.
Sar ye 25 volt mil jay to ye kitne time me by pass karega
If battery is full then instant it will go on.
@@addriexperiments sar Mera Ghar Ka by pass nhi ho rha
Bettery 14.2 tak hai
@@sanjumagar6681 it's a big issue, i am also facing... I just manually operate.
@@addriexperiments kase sar
Bro utl smu par 24 volt panel for 12 v batteries support karega..
No,
ye pwm technology h
utl ka mppt solar charge controller le lijiye best h
@@MsMahendra1988 please read carefully before answering someone.
But thanks 👍
@@MsMahendra1988 And my dear friend utl don't have any mppt solar hybrid charge controller, all models available on hybrid solar inverter mppt. 😂😂
A hybrid hay ji
Yes,
सर मेरे पास 300 watt ke 6 पैनल है टोटल 1800watt 24 वोल्टेज के है
Sir meti meri बेट्री 220ampire की है 12 वोल्टेज की hai
Kya utl का smu लग जाएगा please call me
Utl SMU cannot support 24 volt solar to 12 volt battery like smarten. You have to connect 24 volt inverter with 2 12 volt battery with utl.
Sir main on off battery ka voltage ka set me hota he, panel kohi voltage ka sath sambath nahi hota
In English please.
@@addriexperiments sir mene india se bata raha hu... India se bahar se nahi...kohi bhi smu main on off hotahe battery ka voltage ka hisab se... Company ai sai banate he... Suba se sam tak 50% dhup milega to vi main off on hoga..
@@solerandelectric636 yes I know, this is common settings.
Mere pas 600 wt ka paynl hai 36v ka aor 12 v ka battery kam kr dega ka bhaiya
No only 12 to 12 volt in 600 watt panel.
दोनों को सीधा रखने के लिए गुगार अच्छा है
😄😄 thnx.
UTL smu me bypass off kaise kare ?
In 15 volt and 6+ amp it automatically bypass.
20/40 amp both r like same setup.
How much panel you have connected?
@@addriexperiments 180*3
@@satvirsingh483 It will work, no issues.
When battery fully charged in 16+ volt and 6+ amp it will automatically bypass. But make sure usable amp must be same
12 volt par ye Kam karega ni
bhai aap galat compare kar rahe ho
mppt ka mppt ke sath campare karo or pwm ka pwm k sath compare karo dono technology alag alag h or isme panel bhi alag alag volt k lagte h
aap ka compare galat technology k sath h
Please watch carefully all my videos so you can understand I am not doing what you have realised.
I know very much about technology, just elaborate all flaws so a normal person can understand.
Dono bekar he bettry kharab karate he 30V se charge hota he.
Both are comfortable with C10 battery, so please be careful with your old inverter battery.
Battery type select karne ka option kyu Diya hai isme fir?
Utl mat Lena
Sir Aapka Mobile Dijiye Sreen mein
30 amp rating ka kya matlb h
It means max solar panel you can connect 30 amp.
Like if a 100 watt panel can produce 5 amp so in total 5×6= 30--- 600 watt panel you can connect.
4 panal 160w 24v bnakr 12v 200ah battery pr use kiya tb 30 amp mil rha h kya enko perellal me 12 use krne pr kitna boost krega
@@sheelendrakumar8523 In smarten it can possible, boost can be 15% depends on weather.
But make sure volt must be in-between 25-45
@@addriexperiments smarten 30/12v pr 24v ki 3panal ad kr sakte h 12v battery pr
Sir mujhe kuch jankari chahiye ap ka number mil sakta h
7003200293