Carotid ultrasound for volume responsiveness assessment

Sdílet
Vložit
  • čas přidán 15. 08. 2024
  • This video will go over the techniques on how to perform 3 measures of carotid ultrasound measurements that may correlate with volume responsiveness: carotid blood flow, carotid flow time, and pulse variation

Komentáře • 7

  • @jorgeotero8787
    @jorgeotero8787 Před rokem +1

    amazing and simple explanation of a very useful tool, thanks

  • @nehalyousry9860
    @nehalyousry9860 Před 4 lety +1

    Very simple & illustrative ... thnks alot

  • @ajaysood9064
    @ajaysood9064 Před 5 lety +1

    excellent and very simple .Thanks

  • @a.caramalac523
    @a.caramalac523 Před 7 lety +1

    The sample volume must include the whole internal diameter of the vessel.

  • @ahmedghanem1983
    @ahmedghanem1983 Před 6 lety +1

    are these procedures for mechanically ventilated or spontaneous breath patient?

    • @emergencymedicine7944
      @emergencymedicine7944 Před 3 lety

      Artery dont vary with ventilation. It changes only with pulse if at all.

    • @nicolaspavez8179
      @nicolaspavez8179 Před 3 lety +4

      @@emergencymedicine7944 respiratory variation of peak systolic velocity changes from spontaneous vent to MV, so yes, this one will only help to predict fluid responsiveness on MV.