How To Commissioning Notifier Panel II Fire Alarm Notifier Panel ko kaise commissioning kare
Vložit
- čas přidán 23. 01. 2024
- How To Commissioning Notifier Panel II Fire Alarm Notifier Panel ko kaise commissioning kare
Hi ! Friends, In this video I will Explain.
Fire alarm panel notifier commissioning with all the small points like smoke detector heat detector ,SLC .and create a loop SLC of 4 smoke detector one MCP and 2 Module And will program and activate make a working all the devices & will demo or mock drill of MCP and Flow Switch with hooter,
Thank you.
Isolation Module connection video link
• What Is Isolation Modu...
Control Module connection wiring video link
• Control Module work an...
Monitor Module connection wiring video link
• Monitor Module Connect...
Control Module connection wiring video link
• How do Integrate Press...
Autoprogram video link
• How To Program Notifie...
Loop configuration video link
• Notifier Alarm Panel L...
#electrical #firefighting #conventional #construction #notifier
Please subscribe my Channel for more informative video. - Věda a technologie
Nice video sir
The videos seems very educational if possible can we get the English version thanks.
Thanks for watching, but subtitles are already given in English it will help you.
Good explanation ❤
Very nice sir
Thank you sir
All the best
Thanks sir ji
,👍
Kabhi dino se isi video ka wait kar rahe the sir,ye video ke liye thanks a lot sir
Thanks for your support and admiration.
Wow very knowledgeable video sir
Bhut din se wait kar raha tha
👍👍👍👍
👍☝️
Ravel ka conventional pannel ka flow switch ka connection ke video banaiye jisse hooter baj sake.
Okay jaldi hi upload karenge ye video.
Rebel panel of flow switch ka hooter bajane wala
Very good sir❤❤
Good job
Keep posting more videos
I hope you watching all videos, thanks brother...
Nice information sir
Thanks 👍
Men gate ke liye kaun sa model lagaenge sir
Relay module
Kaun sa model lagane per LED bulb on ho jata hai
Speaker ko loop card se bajana hai.
Very good Sir 👍
Thanks
Hi Add Video for Installing more than 2 NFS2-3030, DVC Card, Amplifier, and ACS Switch and LED Cards, Speaker and Programming Method in the Verifire tool
helo sir .can you show how to wire addressable annunciator from fire alarm panel
Ye 1 loop card me 1 loop laga h ya 2 loop..?
Nice😂
Ap ke sath Kam karne ka mauka mile to apki kripa hogi sir
Agar panel m naya loop install krna h toh sabse pehle devices aur module ko address dena h phir loop card m connect krna h uske paad loop configure krna h ( panel program option m jake) aur last m auto learn krna h right. Pls reply
Sahi hai but auto program karne sa pahle loop card LCM me bhi address dalna hai
Dilshad bhai
Mujhe ek naya loop install krna h panel m. Mere pass 10 detector, 2 mcp, 2 mm model, 3 cm modu aur ek relay module h Lekin mujhe bs detector ko address dena aata h baki mm,cm mcp ko kya address dena h mujhe nhi pta . Pls bata dijiye.
Mere channel me address setting kar k ek video uploaded h pls see that video,it will solve your problem.
Thank you
Sir apna mobile number
Contact on 👇
dilshadanjum51@gmail.com