In this video, we delve into the fundamental issues that can affect energy meters causing disruptions in your electrical supply and potentially higher bills. Understanding these common faults is crucial for homeowners business owners and electricians alike.
Here's what you'll learn in this video:
What is a neutral fault and how it impacts your energy meter.
The significance of an earth leakage fault and its consequences.
Tips for identifying these faults in your energy meter. Steps to prevent and address these issues to ensure efficient electrical consumption.
In this video I practically explain by using two WAPDA energy meters what is meant by reverse light and earth light on energy meter and three major faults like common neutral earth leakage and reverse voltage.
There are so many common reasons why you might experience higher electricity bills due to wiring faults like:
Resistance in Wiring: As wiring ages, it can develop resistance, causing it to heat up and waste energy. This resistance leads to increased power consumption and higher bills.
Poorly Installed Wiring: Incorrectly installed wiring, such as loose connections or improper sizing, can lead to energy loss. For example, undersized wiring can cause voltage drops, requiring more electricity to power your appliances.
Overloaded Circuits: Overloading a circuit by connecting too many devices or appliances to it can result in overheating of wires and increased energy consumption. This can also be a safety hazard.
Deteriorated Insulation: Over time, the insulation on wiring can degrade, leading to electrical leakage, short circuits, and even fires. When insulation is compromised, more energy may be required to maintain the same level of electrical safety.
Ground Faults: Ground faults occur when there is an unintended electrical path to ground. This can result from damaged or faulty wiring and can lead to increased energy consumption and potential safety hazards.
Old or Outdated Wiring: Older wiring systems may not be as energy-efficient as modern ones. They may lack insulation, grounding, or other safety features found in newer installations.
Voltage Fluctuations: Wiring faults can cause voltage
fluctuations in your electrical system. Appliances operating at voltage levels lower or higher than they require can consume more energy and reduce their lifespan.
Inefficient Appliances: Faulty wiring can sometimes affect the performance of your appliances, causing them to operate less efficiently and use more electricity.
Hidden Leaks: Some wiring faults may not be immediately visible or obvious. These hidden faults can continue to waste energy without you realizing it.
Constant Electrical Load: Wiring faults can cause an electrical system to maintain a constant load even when appliances are turned off. This "phantom" or "vampire" load can significantly contribute to higher bills.
If you want to safeguard your home or business against neutral and earth leakage faults and gain a better understanding of how energy meters work, this video is a must-watch
digital energy meter,
why red light blink on energy meter,
how to check digital meter reading,
how to check meter reading in digital meter,
wapda digital meter,
how to check meter reading.
electric meter light indicator.
digital meter meter ki setting
bijli meeter slow kaise kare .
electric meter slow karne ka jigar
how to stop electric meter .
#energymeter #kwhmeter #education #engineernoumanofficial
#educational
#digitalmeter
#educationalvideo
#engrrabiafiaz
#ElectricityBills #EnergyEfficiency #WiringFaults #ElectricalSafety #Neutral Faults #EarthLeakage #EnergyConsumption #UtilityBills #ElectricalFaults #ReverseLight #Electricallssues #FaultyWiring #UtilityCosts #ElectricityConsumption #Electrical Problems #energymanagement
PowerSavings #SaveOnBills #ElectricalTips
Hello Friend:
Assalamualaikum I'm Asif From Pakistan
In this channel I will give you information about electrical things and also tell you how to repair things this channel will grow because of your support you are my youtube family if you like my If you like the videos please subscribe this channel and share your friend Asif Electrical
Whatsapp
03214332671
Playlist Videos
Tips to perfectly Charge Your Smart
• Tips to Perfectly Char...
Set Electricity Units control By Your Self
• Set Electricity Units ...
Wapda Meter Slow Karne Ka Tarika
• Set Electricity Units ...
How to detect electricity theft
• How to detect electric...
Wapda electric meter ka speed slow
• Wapda electric meter k...
Using Ceiling Fan with AC Explained
• Using Ceiling Fan with...
Digital Electric Meter Slow Down Legally
• Digital Electric Meter...
اس ویڈیو کا مجھے بہت فائدا ملا
Thanks friend
Good luck sir
Thanks
Super video g😊
Thanks 😊
Very nice video Asif bhai
Thanks
Wow.🥰
Thanks
Very good work friend super
Thanks friend
بہت شکریہ علم میں اضافہ ھوا
Thanks friend
Very good work friend super video 😊
Thanks
Very good work friend
Thanks
Thanks friend very good information
Thanks
Very nice 👍 video friend 😀
Thanks
Very good
Thanks
مجھے آج پتہ چلا ان لائٹس کے بارے میں
Ok thanks
کراچی مین کوئی ایسا مٹر نہیں ھے جس میں ایک ریڈ لائٹ نہیں جلتی ھے
آخر کیا سبکے وائرنگ میں خرابی ھے۔
اج آپ نمبر 1 2 3 4 5 کا ذکر کر رھے ھیں۔
اس طرح تو ھر شخص جس نے آپ کا ولاگ سنا تھا سب ھی پریشان ھوئے ھونگے
یہ میٹر کراچی میں نہیں لگائے ابھی مگر ھم لاہور میں ھے یہاں لگے ھیں اسلام آباد میں بھی
@@asifelectrical4302 ok
میری پانچ نمبر یعنی ارتھ والی اوپر اور نیچے والی منزل کے دونوں میٹرز کی لائٹس آن رہتی ہے
یہ فالٹ ھے اس کو دور کریں
کیسے دور کریں؟؟؟
بھائی بیان میں سولر انورٹر کی انپٹ آن کرتا ھوں تو واپڈا میٹر کی ارتھ والی لائٹ آن ھو جاتی ھے حل بتا دیں
@@Asadmehmood548 ap k Ghar meter 1 ha ya 2 lgay hoy
اسلام علیکم
میں نے سولر انورٹر لگایا ھے جب بھی اس کی واپڈا ان پٹ آن کرتا ھوں تو واپڈا میٹر کی ارتھ والی لائٹ آن ھو جاتی ھے اس کا کوئی حل بتا دیں
Aapne single wire lagai ho gayi neutral aur face donon solar ke liye istemal Karen
Thanks friend
السلام عليكم ورحمة الله وبركاته آصف بھاٸ میٹر ضرورت سے زیادہ تیز چل رھا ھے کیا اسکی کیلیبریشن کرواٸ جا سکتی ھے ؟ کیا طریقہ ھے یار تین پنکھے چلے ھیں بارہ گھنٹے تیرہ یونٹ چل گیے اندھیر ھے بھاٸ کیا کیا جاے کہ بل درست آۓ پلیز ریپلاٸ کریں
بھائی آپ کو جو سا دفتر لگتا ھے بجلی کا وہاں جاکر کمپلین کریں میرے WhatsApp نمبر پر مکمل تفصیل سے آواز ریکاڈ کرکے بھیج دیں کیا مسئلہ میڑ کے ساتھ ھے 03214332671
Very nice vedio thanks
Very good friend 👍
Thanks
5نمبر لائیٹ 5مہنے سے نہیں بند ھو رہی دو دفعہ الیکٹریشن کو بلایا ھے مگر فالٹ دور نہیں ھو رھا کوئی حل بتائیں بہت زیادہ بل آرہا اس لائیٹ کی وجہ سے
Ok thanks
Sab say phly check Kary k Jo main wire meter say ap k gar main switch tak ja rahe hai wo kahen say khrab to ni matlb kisi jaga say jor ho or Zameen I sath tech ho Raha ho.
Phr ager motor ka plug board me Laga reta hai har time to plug Jo Nikal day phr meter par light ko check Kary.
Phr mujhy batay ga. jazakallah
Good explanation
Thanks friend
Mera 3 phase meter h 3 lights har waqt on rehta h
Video my number
Very simple friend
Thanks
🎉🎉🎉
Thanks
good
Thanks
باہے جان مری میٹر نے 3200 کے جگہہ پر 1000 imp/kwh لکھا ہے مہربانی کر کے بتاؤ تو اسکا کتنے بار پر 1 unit بن گا ؟
1000 دفعہ on ofھوگئی تو ایک یونٹ ھو گا
شکریہ ویڈیو دیکھنے کا
Ma nay new meter Lagaya ha wo 06 error DAy raha hay
Video my number
اس لیے ھمارا بل زیادہ آرہا تھا 3مہینوں سے
Ok thanks
likha hua aata hai to uska kya matlab hai
Kay
میرے گھر بھی یہی مسئلہ ہے
Video dekh kar HAL Karen
😮😮😮😮❤
Thanks
Sirf 1 metr is per ye problem hai
حل batado
Aap mere WhatsApp number per Apne problem ki video send kar de main aapko jawab de dunga mukmmal 03214332671 sirf message no call
اسلام وعلیکم میں نے کل بھی آپ کو میسج کیا تھا سنگل فیز میٹر ھے اس کی ریسوس کی لایٹ جو دو نمبر پر وہ بلنک کرتی رہتی ھے کنکشن بھی ٹھیک ہیں لایٹ جلتی بجھتی رہتی ھے ڈسکرپشن میں بھی کچھ نہیں ملا اگر اس پر ویڈیو بنا دیں مہربانی ہوگی
03214332671 my WhatsApp number please voice message
بھائی سنگل فیز میٹر ھے اس کی ریوس لایٹ بلنک کرتی ھے جلتی بجھتی رہتی ھے اس کی کیا وجہ ھے یہ ٹھیک ھے یا غلط ھے بتا دیں شکریہ
غلط ھے
میری id میں ویڈیو ھے دیکھ سکتے ھو
میں یہ ویڈیو دس بار دیکھ چکا ہوں میرے سوال کا اس میں جواب نہیں
کیا سوال ھے آپ کا
السلام علیکم و رحمت الله و برکاتہ.
محترم میں کراچی سے ہوں میرے گھر میں دو میٹر ہیں دونوں تھری فیس ہیں ہم نے جنریٹر بھی رکھا ہوا ہے، مہربانی فرمائیں اور رہنمائی فرمائیں کہ جب ہم جنریٹر استعمال کرتے ہیں تو دونوں منزلوں کا چینج اوور جنریٹر پر کر دیتے ہیں اب اندازہ یہ ہو رہا ہے کہ دونوں منزلوں کا نیوٹرل ملا ہوا ہے جس کی وجہ سے بل زیادہ آ رہا ہے آپ نے جو یہ ویڈیو بنائی ہے یہ سنگل فیز میٹر کی ہے یہ پرابلم ہم اپنے پچھلے گھر میں فیس کر چکے ہیں اب مہربانی فرمائیں اور تھری فیز میٹر میں اس پرابلم کا حل تجویز فرمادیں ، الله آپ کو خوش رکھے، امید ہے جواب سے ضرور نوازیں گے. والسلام علیکم و رحمت الله.
Three face check karne ke liye aapko tone tester chahiye Jo fridge AC walon ke pass hota hai jis se am check karte Hain
Thanks
Jab may ups ko no karo os k bd earth light on hota hai
Aap ki koi cheez earth ha jis ma say short leak ho raha hai
Thanks