इस Star Delta मोटर में मेरा 12 साल का अनुभव फेल हुवा। छोटा problem बड़ा धमाका
Vložit
- čas přidán 26. 07. 2024
- इस Star Delta मोटर में मेरा 12 साल का अनुभव फेल हुवा। छोटा problem बड़ा धमाका
About this video
hamane is video me bataya hai ki
ham star Delta motor ka problem kaise nikal sakte hai
star dekta motor phase uda rahi hai to ky jare
star Delta motor ka connection kase kare
star Delta motor cable wire starter ko kaise jode
in Sare bato ke bare me hamane is video me bataya hai
अब हर किसान अपनी Star Delta (दो केबल वाली) मोटर खुद चेक करेगा। short check with Lamp star delta
About this video
hamane is video me bataya hai ki ham ghar pe star Delta motor kaise check kar sakte hai
series lamp se star Delta motor kaise check kare
How to check star delta motor with series lam or testing lamp
how to check short and Continuty of star Delta motor by tesing lam or series lamp
About this video
Hamane is video me bataya hai ki
hamare kisan bhai ghar bhaite apani submersible motor lamp ke madat se kaise check kar sakta hai.
अब हर किसान अपनी submersible मोटर खुद चेक करेगा। ...मोटर चेक करने का आसान तरीका motor short checking with the hepl of serese lamp
submersible motor short and continuity checking with the help of testing lamp
100w , 60w, zero lamp onely use
Akil Baraskar
from
Advantage and Technology channel
CZcams
हमारे दोनो channel की लिंक नीचे दिया गया है 😜😇😆
1:- / @akilbaraskar3968
2:- / atcreativechannl
नये लोगों ने सबसे पहले ये play list चेक करना हैं।
Video देखना हैं तो निचे लिंक पर क्लिक करें।
• New Winder नये लोगों क...
हमारे दोनों चैनल को Subscribe करने के लिए निचे लिंक पर click करें....
1. Advantage and Technology channel
/ advantagetechnologycha...
2. Advantage and Technology Creative channel
/ atcreativechannel
Other playlist....
1..Boarwell problem:- • Boarwell problem
2..Autoswich Connection:- • Autoswich connection t...
3..Submersible motor short and continuty checking method:- • Submersible motor chec...
4..Coment box... Sawal-jawab:- • Comment box... Sawal -...
5..Naye hai to motor sabse pahale ye video dekhe:- • New Winder नये लोगों क...
6..motor winding connection with digram:-
• New Winder नये लोगों क...
7..motor khol fitting :- • Motor khol fitting
8..All motor connection:- • Motor connection
9..Starter problem solution and repairing:-
• Stator problem repairing
10..pump Repering:- • Pump Repairing
11..New winder hai to aap ke liye ye sare besic video:- • New winder नए है तो य...
12..All motor winding:- • Motor winding
हमेशा मेरे साथ बने रहने के लिए निचे लिंक पर click करें और follow करें.....
Facebook :- / akil-baraskar-10586040...
Instagram:- / akil_baraskar
Twitter:- BaraskarAkil?s=09
खरीद ने के लिए नीचे लिंक पर क्लिक करें
Digital clamp meter:-amzn.to/3t7FCOT
maltimeter:-amzn.to/3taY61c
My best mic :-amzn.to/2D9bZbG
My best camera :-amzn.to/2WWGPeZ
My tripod :-amzn.to/2ZYvzjS
My video shutting dolly, slide show
amzn.to/2lKlpSP
#StarDeltaMotorProblems - Věda a technologie
वेरी गुड सर बहुत अच्छी शिक्षा देते हो
Bhai colour ke hissab se kabhi mat chalo phase ki countinuity chalo....
Kabhi kabhi koi motor woner motor ke cable joint colour wise nahi karata isiliye pahale check karana zaruri hota hai....
Teh Dil dhaneywad sirji etni achhi jaankari dene k liye 😍🙏
Bahot badiya guruji ye sahi bat hai ❤ very good
Pehla video dekha or subscribe bhai KIA,
Aap guru ho sikhane ke liye
Really good information sir.
खुप भारी माहीती सर
धन्यवाद आतील भाई
Nice bhau 👍
Super information sir
Thanks for shearing good info
Thanks bro ❤❤
Pahle se chalne ke liye vah star mein chalega to bad mein vah dalta mein pad jaega a wall starter nahin hai to isliye aur digital mein timer hoga to hamara password problem aaya tha isliye a jao Bata rahe ho sar bahut knowledge phool hai sar achcha Laga jo aap koi technician ke pass share kar rahe ho bahut achcha Laga
supar.ansar.sir
Good sir.🙏🙏
Thanx you sir
Nhi pta thha apka dhanyawad
Very good ye chhoti chhoti chije hi technician ko bahot kuchh sikhati hai.
Thank you🙏 sir
Mu1 डेल्टा ब्लॉक में कनेक्शन करना चाहिए जो आपने किया है वह सही है
Nice video Sir
Thankyou sir
Very simple connection hai
Very good 👍
સરસ જાનકારી
Bhahut danger process he Sir
मार्किंग ना होना और शुरुआत से आपका का उस कनेक्शन में हाथ ना होना यही मूल वजह है जो की ग्राहक को समझना मुश्किल होता है
Thanku so much Akhilbhai..🙏
Nice👍👏👌 ❤🧡💛💚💜💙
Sar ji hame problam pata nahi tha thanks sarji video banane ke liye
Nice 👍👍👌👍
Love you Bhai
Star delata stater par video bnai
Very nice
Bhai in to wignig contion ki vidio bnao
Thanks
Ok sir thanks
Good explain sir
Super
👌👌
Supar
Supper
1नं सर
Sir mujhe single phase our three phase motor ki wainding ki swg turn pitch our coil grup nikalne ka formula chahiye please batao
🕺Super ,, i am big fallower , i am also repair all type motor winding ,, i know startar repaire ,, next next video ko shuru startar details , and problem solution and how check
Sure 👍
Sir mere sath aisa hi huva tha
Bro ,🙂 first check the all internal connection of panel with multimeter without three phase supply
Then check through LLY weather it is star delta or other then ensure all the cables and leveled yourself to not get confuse on it .first run one pump then again second ,and third ok
And also check control wire of star delta then it will work properly man
Bilkul right bro ......ye chalu chhap electrician h
A1-b2
B1-c2
C1-a2 ke sath hoga
Aap ko continute check kar ke pata karna chai tha
Sir 6mm cable me single cable se Delta connection kr ke 10 hp moter chala skte h kya....mere gav me water lable 500 h to double cable se kharcha bhut aa rha h
Akhil Sir AAP cooler code pe mat jana sirt ek simple trick ye hain ke 1phase winding ko440volt Milana chahiye
Appney dono coil ka connection karanay say pahalay 3 wier direct phale jood kay aur 3 wier ko kulay rahaney daytay aur multimiter kay satt 440v ak, ak kar wier jodatay to appko dikat nhi hogi
ML2 F stater main bhi yahi hai Drawing dhekh kro star contractor main achhe se connection dekho chek kro No colour coding Find only eng. Think ok bhai jo bhi problem aaya seyar kiya thanks
Vava sar
भाई ये मेरे साथ भी हो चुका है
हा भाई मुझे पता है एस्का कनेशन .....
Good
Sar istar connector me cibal lagasakte hi
BCH k started main delta stater mai he hota hai with out multimeter kaam krne ka tarika casual hai
Nice
O ho 😊❤
Bhai dayagram padhana sikha dijiye
Bhaiya star delta motor connection aise karega to motor overload hoga hee aap star delta motor connection karane se pahale motor ka terminal check Kijiye. Usake bad stater ko on kar ke output voltage check Kijiye. Or star me or delta me dono me voltages check kar ke tab connection Kijiye tab kabhi nhi stater ka phase short hoga
Motor 11a current leti hain aur Maine relay setting 10a pe kia hai tab bhi motor achii chal rahi hain tab koi problem aa sakti hain
Bhai konsi company ka starter best hota hai iski ek video banaoo please
bhai saab kisi bhi side per jao hmesha 0 se start karna ratan vidiya nhi lgani ye ratan vidhya lgane ka kam costmer karta h mistri hokar bhi apne sath ye situations to honi nhi chahiye mistri bhi aker ratta lagaye to kuch matlab nhi h apne 10saalo me jhak hi mrayi h admi perfect tab tak rhega jab tak wo kaam karta rhega kisi bhi side per jao starter connection pure chek kro thank you bhai saab mujhe bhi experience milta h kis jagah dhayan jyada dena chiye
Startar main connection chenge hoga ho skta hai
aap star delta ander se color se bnao
Sir Aaj kal volt ki bahot problem hai Aaj kal volt 400 btata hai lekin usme jitna karent hona chahiye utna nhi hota hai to motor ko kis tarah se bnaye Ki vo Pani theek se dene lage sir please Eska koi solution btaye Kyo ki Aaj kal yhi ho rha hai jisse kisan Bhai bhot presan hai please ❤
Apne main contecter or star contecter me connection kiyatha ye galat hai. Main contecter or delta contecter me connection joint karna hota hai. Apne cabal connection galat kiya tha. Sahi conection-RYB /BRY hota hai. Ape ache mecanic ho. Khai bar galti ho ja thi hai
Main or star mein karte hai bhai,delata maein Kiya to starter or motar jal jayegi
Mujhe nahin pata tha ji
Star Delta starter me m power kaise lagta hai vidio bhejona sr
Sir nahi pata tha
Another set of no nc in different place how to connect please tell me bro
Bhaisaheb colour code se delta nahi milana chahiye starter mai 1 phase already change hoke aata hai kisi mai nahi aata hai best way hai aap series test lamp se delta mila kar connection karo
Sar ji humko is per delta wala starter Ghar per banane ka tarika batao
Main or delta me jodna chahiae
Sir एसी विषय पर ओर व्हिडिओ बनाव ओर फुल्ल डिटेल व्हिडिओ बाणाये मोटर के कनेक्शन भी दिखाये
Sar ji samne start contractor sath rahata hai to 220 volt mein motor uthata hai start chhodane ke bad 440 ka crane lagbhag hai meter se pahle continuty check karo uske bad A1 A2 b1 b2 C1 C2
Sir star delta motar singhal cebal par cepesiter kese lagaye
Jb v star Delta stater hota hai usme motor ki wire hmesha main contractor aur Delta contractor me lgta hai. Aur rahi baat r, y, b ka to multimeter se continuity check kijiye, aur aisa connection kijiye ryb ka ki continuity n aye motor turnt chlegi.
Sir Bcs statar ke bareme batai
अखील भाई तुम बताते बताते बहोत कुछ डायलॉग मारते हो 😂😂मुझे बहुत हसी आ रहि है😂😂😂😀😂
Aap ko startor mea a1,b1,C1 phase A2,b2,C2 phase voltage chake kar connection karna chayea tha
Starter banane walo ne motor cable connection ke liye U1 V1 W1 aur U2 V2 W2 nahi diya hai to ye problem ati hai. Aur star contactor ko jodna waise bilkul galat nahi lekin balki aapko jyoki compani walonehi wire ghumake de di gai hai to apko motor wire ke colour bilkul ghumane nahi hai. Main contactor ko RYB hai to star contactor ko bhi RYB hi lagana hai.
Apne khud ka pahalewala jo connection jagah galat nahi thi sirf galati yahi thi ki aapne colour mismatch kiya.
U1 ----red wire U2 red wire
V1 yellow wire V2 Yellow wire
W1 blue wire W2 blue wire
Matlab pahela 3 core cable U1V1W1 ko RYB wire
agar star contactor pe niche
W2 U2 V2 aise pahale se unke connection hi ghumakar diye hote hai. Aise halat me
colour ko mat ghumao wire ke colour RYB aur RYB hi lagenge.
Local unbranded starter me
U1 VI W1 ----------U2 V2 W2
Ya to
U1 V1 W1 ---------W2 U2 V2
likha hua nahi hoga isliye apane uska jikra bhi nahi kiya hoga.
Please try my suuggestion .
Aur ek simple technic mai baata hn jijme kabi bhi fuse nahi udenge . Apko company ki wiring ko sidha ya ghumake dekhneki jarurat nahi hai.
1. Pahale main contactor ko RYB aur star contactor ko bhi RYB( lal pili nili) aisehi jodo. Aise me do chise ho sakti hau . Starter semi automatic hai to on push button jabtak dabake rakhige tab star me chalege our button chodne par delta contactor utheda likin motor ghumna band karegi. Yato bina fuse ude delta me aaram se run hogi.
Agar delta me motor ghumna bhand hoti hai to sirf star contacor ki cable wire ko RYB tini wire ko nikal kar Y R B color jodo.
100% kaam ok hog. company wiring ko dekhneki jarurat nahi hai.
Aapke us trial mn star me motor chali hogi aur delta me padtehi fuse ude honge.
Please give your feedback on my suggestion results on 9673990859
Motor connection karne se pahle starter ka internal circuit check kiya jata hai starter ek bar on karke check kiya jata he uske baad motor connection kaijata he
Kya Maloom Gurudev kya samasya
Muche sikhana hai
12 HP ki naya moter he isme RYB,BrY lagaya he firbi moter start nahi ho rahi our fuse Kat yaha he
🙏🙏🙏
Sar yah digital starter timer hai to timer ka taraf to star mein chalta hai to 2 second baap 5 second part aur delta mein pad isliye sar niche lagana
मैं तो कुछ नहीं जानता क्या सही क्या गलत हैं! हां पर सीखना हैं!
Sir apne 3 starter main line jordiya sir 2 starter me hoga sir
thinks
Ok
Motar conectin wire colar chang
Star delta connection .
🎉
Ye sac hi
Sar niche ka starter short Hota Hai Shuru Mein motor star per Chalti Hai bad Mein Delta Ho Jaati Hai
Mera confusion aapane Dur kar diya thank u
बाद मे मोटर डेल्टा में ही चलेगी 😂😂😂