English - Sewer line design / design of sewer pipe.

Sdílet
Vložit
  • čas přidán 24. 08. 2024
  • Help others, God will help you in return
    Join my WhatsApp group: chat.whatsapp....
    access to my courses: click link below
    www.udemy.com/...
    Facebook : engineerboyofficial
    Tiktok: tiktok.com/@engineerboyofficial
    Insta: engineerboyofficial?igshid=OGQ5ZDc2ODk2ZA==
    my business WhatsApp: +92 3254065292
    love you dears.

Komentáře • 85

  • @jsikjbsuoyewg
    @jsikjbsuoyewg Před 3 lety +1

    One of the best videos on sewer design. so nice thanks dear sir

  • @afvk7136
    @afvk7136 Před 5 lety +2

    I am structure designer and it,s first time I see sewer pipe design.I believe, it shouldnt be that much easy to design.

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 5 lety

      Greetings sir ! You are right but the video teaches only the size design... this video or design is based on discharge of sewage, and structure designs are done based on loads..... thank you for joining us.

    • @afvk7136
      @afvk7136 Před 5 lety

      @@EngineerBoyOfficial Thank you for your responding

  • @sasankabiswasray
    @sasankabiswasray Před rokem

    What right right, every sentence right right.

  • @CivilEngineersite
    @CivilEngineersite Před 5 lety +1

    VERY NICE KEEP IT UP

  • @rashidahmad8700
    @rashidahmad8700 Před 7 lety +1

    Brother ALLAH give you more strength and health....

  • @gulamkhatri1923
    @gulamkhatri1923 Před 3 lety

    Bro really your best guideline

  • @joaquinfabrega
    @joaquinfabrega Před 5 lety

    One of the best videos on sewer design. Greetings from Panama

  • @nickatnight7814
    @nickatnight7814 Před 4 měsíci

    Why would you design the sewage pipe to be at max flow? aren’t they suppose to be less than 100%

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 4 měsíci

      1) sewage may increase after few years.
      2) extra waste such as plastic bags, soul etc can decrease pipe diameter.
      3) etc

  • @khattabhamdan5659
    @khattabhamdan5659 Před 6 lety

    well done

  • @shivashankar9190
    @shivashankar9190 Před 5 lety

    Super explanation sir

  • @sheikhkais4140
    @sheikhkais4140 Před 5 lety

    So fine sir

  • @FaisalKhan-fn5yz
    @FaisalKhan-fn5yz Před 5 lety +1

    Air filteration and other factors slope etc are missing ???

  • @htedddghhu8352
    @htedddghhu8352 Před 5 lety

    Make videos about prefabrication topics

  • @engbasseljassem2293
    @engbasseljassem2293 Před 5 lety

    Thanks bro.

  • @jalilalmteen536
    @jalilalmteen536 Před 5 lety

    Nice Video , I have a question
    How can I make sure that the pump is matching pipe size during site inspection especially for left sewer station ?

  • @beditz1591
    @beditz1591 Před 6 lety +1

    Plzz upload more vidoe for PHE and irrigation from India

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 6 lety

      I will try soon dear

    • @beditz1591
      @beditz1591 Před 6 lety +1

      Engineer Boy bhai 1.5 month me exam hai or Irrigation ka kuch bhi study nahi huwa hai... plzz upload more video irrigation

  • @AbdulQadeer-hi4jz
    @AbdulQadeer-hi4jz Před 5 lety +1

    man you have made it too lengthy,please try to make it easy for us

  • @enigmaa5195
    @enigmaa5195 Před 5 lety +1

    40 сm pipe will not be able to carry 120 liters per second

  • @pochinki4352
    @pochinki4352 Před 3 lety

    Please help me test the design of health systems for the money

  • @shooterjames2078
    @shooterjames2078 Před rokem

    Questions

  • @noumanhasnaini4838
    @noumanhasnaini4838 Před 7 lety +1

    السلام علیکم پیارے بھای بہت بہت شکریہ کافی سیکھنے کو ملتا ہے۔اچھا کیا آپ staad pro بھی سکھا سکتے ہیں یا کوی ادارا بتا دیں پاکستان مین جو سکھاتا ہو

  • @msarmadrriaz2519
    @msarmadrriaz2519 Před 6 lety

    Plz tell me how I calculated the num of bricks for man hole...

  • @harish5308
    @harish5308 Před 7 lety

    sir upload other environmental engineering topics

  • @hayathussain3877
    @hayathussain3877 Před rokem

    how it will be 2/3 + 1.5

  • @zainjarra8802
    @zainjarra8802 Před 5 lety +1

    Bro i am fresh done enginering ...so need some tips

  • @4umahin
    @4umahin Před 6 lety

    Hello SIr,
    How did we get to know its filled 2/3 and what is the criteria to take 2 or 3?

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 6 lety +1

      Its ratio 2/3 . It means 2 divided by 3.
      In design we assume 2/3 full

  • @laljikanojiya8207
    @laljikanojiya8207 Před 5 lety

    What is Sever line rcc pipe ka grediyant

  • @abdulwahabkhatir8443
    @abdulwahabkhatir8443 Před 7 lety

    salam sir je make a video center line method

  • @sheikhkais4140
    @sheikhkais4140 Před 5 lety

    One thing lab lab lab .
    Hahahaha

  • @gopalautocad4158
    @gopalautocad4158 Před 5 lety

    How do we get the value 0.15 by taking 2/3 or 3/2...?????

    • @PaoloCassarManghi
      @PaoloCassarManghi Před 4 lety

      Dividing a number by 2/3 (i.e. 0.666..) is the same like multiplying by 3/2 (i.e. 1.5)

  • @pochinki4352
    @pochinki4352 Před 3 lety

    can you help me

  • @beditz1591
    @beditz1591 Před 6 lety +1

    Bhai ye paid lecture hai kya ??? From India

  • @manikarthi7734
    @manikarthi7734 Před 6 lety

    How do you know discharge valve of sewer line and velocity

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 6 lety

      Can be calculated from people water demand and other sewer lines assumption. Also can be calculated from drains where sewer is to be provided.....

    • @manikarthi7734
      @manikarthi7734 Před 6 lety

      @@EngineerBoyOfficial can you send some example project details file please , send it engineer boy manikarthi004@gmail.com

  • @j.karthikjayavelu3655
    @j.karthikjayavelu3655 Před 7 lety

    material calculation for floors that video file cannot open sir send another same video

  • @shaqsenthumule6945
    @shaqsenthumule6945 Před 6 lety +1

    I prefer using manning for sewer. Your approach is dodgy.

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 6 lety +1

      hey thank you for joining us.... i you mean by manning the manning formula, than remember for manning formula we will need constant of manning, bed slope of sewer and little hardworking for witted perimeter. so i think my approach is little easy ... what do you think?

    • @shaqsenthumule6945
      @shaqsenthumule6945 Před 6 lety +1

      Remember we design sewer line to flow partially full. The manner in which you applied the continuity equation suggests that the pipe flows full.

    • @alanhowitzer
      @alanhowitzer Před 6 lety

      Use Bernoulli's equation!

  • @farhanramzan255
    @farhanramzan255 Před 6 lety

    sir why you multiply .15 with 1.5

  • @mukeshsingh-jc3vx
    @mukeshsingh-jc3vx Před 3 lety

    Sir velocity kese nikalege ?

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 3 lety

      Can be found by different ways. Like float method. Current meter can be used. Pitot tube can be used etc

  • @snowheart469
    @snowheart469 Před 7 lety

    excuse me can you explain to me how get 1.5 in the point of full flow it's standard or what
    thanks for interesting

  • @cheras445
    @cheras445 Před 6 lety +2

    over stylish pronunciation is a bit gloomy to bear with. i request sir to be in natural accent. thankyou

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 6 lety

      hello . this is not my mistake or fault . i pronounce it better but when i edit my video in computer. the software changes the effects. i do not know how to fix that,,,

  • @willwill6150
    @willwill6150 Před 7 lety +1

    annoying pronounciation, he pronounce it as "siwir"

    • @EngineerBoyOfficial
      @EngineerBoyOfficial  Před 7 lety +3

      Wilbur MC
      thanks for notice dear i will try to promote it. however i am not teaching an English. i am teaching just engineering

    • @farhadhamza6001
      @farhadhamza6001 Před 4 lety

      Engineer Boy lol 😂