  • Diagnosing of the Hoshizaki KM Series Ice Machines. Video made by Hoshizaki America.
    Hoshizaki Ice Makers
    www.gofoodservice.com/brand/h...

Komentáře • 23

  • @tekman2000
    @tekman2000 Před rokem +4

    Thank you for taking the time to make this FANTASTIC diagnostic video 😀👍

  • @wesleyreach1144
    @wesleyreach1144 Před 3 měsíci

    Thank you very much. Great video takes me straight back to high school ag class

  • @DaCrunkwizard
    @DaCrunkwizard Před 4 lety +5

    Love that 90s style intro

  • @tomascoronado9502
    @tomascoronado9502 Před 7 lety +4

    great video!

  • @AndresCura-ys5vb
    @AndresCura-ys5vb Před rokem

    Exelente ayuda para nuestras dudas y problemas técnicos grasias

  • @wellingtoncamargo8133
    @wellingtoncamargo8133 Před 3 lety +1

    Great explication !!!!1

  • @whitebear1903
    @whitebear1903 Před 3 měsíci

    Awesome

  • @briangiven7399
    @briangiven7399 Před 2 lety +1

    I have a KM-1900saj that dumps a lot of water into the drain. Is this normal for this style ice maker? I know it can rinse water though the system but heard that some units are water cooler compressors and may dump water for this reason.

  • @kleberluismoura7313
    @kleberluismoura7313 Před 5 lety +4

    Poderia ter um video traduzido para portugues, tem muitas maquinas hoshizaki no Brasil...

  • @marcdorizar5742
    @marcdorizar5742 Před rokem +2

    where should i purchase the tech spec's book please?

  • @rosskious7084
    @rosskious7084 Před 3 lety +2

    Most thermistors fail open or shorted. I have seen a few with the values off. However this is not common.

  • @user-gm4xx1zm3g
    @user-gm4xx1zm3g Před 7 měsíci

    i have a KM-520maj and dumps a lot of water into the drain. what is the cause

  • @bubbasmith3219
    @bubbasmith3219 Před 6 lety +2

    Is the fan supposed to run the whole time

    • @Pious-Inquisitor
      @Pious-Inquisitor Před 5 lety +4

      Fan should only run when compressor is running

    • @alexandercanto7587
      @alexandercanto7587 Před 2 lety

      The compressor should be always running, the fan should stop on the Harvest cycle

  • @GaunttFarms
    @GaunttFarms Před 4 lety +1

    HOW DO YOU CHECK THE CIRCULATION PUMP ?

    • @GoFoodservice
      @GoFoodservice  Před 3 lety +1

      Information taken from Hoshizaki's Troubleshooting Guide:
      The water pump itself can be easily tested by putting the unit in wash mode via the 3 position toggle switch found at the top of the ice maker. You must however also confirm the operation of the water pump in conjunction with the control board. When the unit begins the freeze cycle, the water pump and condenser fan motor should energize on self-contained units (with remote units, the condenser fan starts with the compressor). If the water pump fails to run, check voltage from the control board K1 connector (red wire) and you should see it running at 110 volts. If not, it is a good idea to verify that the board is actually in the “freeze” cycle. If you find there is power running to the red connector of the pump and it's still not functioning properly, next check the toggle switch.
      For more information, please contact Hoshizaki Tech Support at 800-438-6087

  • @eriksyhre8030
    @eriksyhre8030 Před 3 lety +1

    What is the difference of e board and g board? Please help

    • @GoFoodservice
      @GoFoodservice  Před 3 lety +2

      The E Board (Green) was the main control board used for Hoshizaki ice machines starting in the late 1990s. It was full of features the previous board did not have. Including lights and audible safeties and alarms.
      The G Board (Tan/Brown) was created several years ago as a water saver control board to go with California water conservation laws. This changed water valves and bin controls to keep the unit from wasting as much water on pump-out cycles. It too has many of the same features of the E board just slightly improved.
      For more information, please contact Hoshizaki Tech Support at 800-438-6087