Customer Called And Said the Blower Won’t Shut Off!

Sdílet
Vložit
  • čas přidán 27. 09. 2023
  • In this video I visit a mobile home, the tenants said they can’t turn off the blower! #hvacguy #hvaclife #hvac #airconditioner #heatpump #hvactechnician #furnace #hvactrainingvideos #hvacinstall #hvacinstall #mobilehome
    Merch Store : hvac-guy-2.creator-spring.com
    HVAC LIFE FB Group: / 521086622906115
    Here are links to the tools I use, And it costs you nothing extra to buy from this list:
    Inficon D-Tek Stratus: amzn.to/3RvnXOl
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Blutooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
    Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
    Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    Makita XDT16: amzn.to/3riXuaJ
    Makita 18V Light: amzn.to/3Fw4GW4
    Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
    Makita Jobsite Radio: amzn.to/3HuVp2u
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Flag Velcro Patch Kit: amzn.to/3K8Eswx
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Fluke 975 Air Meter: amzn.to/3GwD9oM
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Aims Power Inverter: amzn.to/3qOSc87
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    American Flag Gator : amzn.to/3rKBl5u
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Komentáře • 52

  • @danobrien3109
    @danobrien3109 Před 8 měsíci +19

    Most units will go to continuous fan when an open limit or roll out occur. This is a built in safety in a lot of control modules.👍👍🇨🇦

  • @tphvac87
    @tphvac87 Před 8 měsíci +10

    Omg that filter is epic!!! Change your filters people!!

  • @paulmoffat9306
    @paulmoffat9306 Před 8 měsíci +7

    Relays can 'weld' their contacts, after enough actuations - each open/close has a small arc that pits the contact surface over time.

  • @jazziez6467
    @jazziez6467 Před 4 měsíci +3

    my blower was stuck on and for the $100 service call the guy pushed the reset(red) button in on limit or rollout switch hiden below the burners, $100 then left without even putting it back together, I had it spotless when he arrived and would never have such filth on my doors, filter, or inner furnace, never

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 Před 8 měsíci +14

    Good video. You’re are really good at electrical troubleshooting

  • @larryl2459
    @larryl2459 Před 8 měsíci +6

    First 2 minutes I noticed they are going to have more than fan troubles.

  • @kens.3729
    @kens.3729 Před 8 měsíci +4

    Thanks Curtis! Hello 👋 Riley! 👍🙏

  • @Capt-Intrepid
    @Capt-Intrepid Před 8 měsíci +12

    I had a defective POS Nest thermostat that would turn the blower on but not the compressor. Now using a ecobee thermostat that understands I am the master. Don't buy Nest.

  • @markspott1741
    @markspott1741 Před 3 měsíci +1

    Excellent video of troubleshooting the blower. Probably saved another call by changing out the air filter too!

  • @user-rq8ch3xb2j
    @user-rq8ch3xb2j Před 8 měsíci +4

    You are the best down south Curtis…
    Rick from
    United Americas Plumbing • HVAC.
    🇺🇸🤜🤛🇺🇸

  • @sjadev
    @sjadev Před 8 měsíci

    I always appreciate how thorough you are Curtis

  • @stevencossaboon3237
    @stevencossaboon3237 Před 8 měsíci +2

    Nice work Curtis.

  • @billybrown1979
    @billybrown1979 Před 8 měsíci +3

    that was a quick fix good work. be safe.

  • @johnnym.rodriguezr3562
    @johnnym.rodriguezr3562 Před 8 měsíci

    Great job diagnosing!

  • @frankblankenship3026
    @frankblankenship3026 Před 8 měsíci

    Very informative thanks

  • @bamatractor
    @bamatractor Před 8 měsíci +3

    I had a brand new blower control board stuck on a few days ago.

  • @Tito-hvac8
    @Tito-hvac8 Před 8 měsíci +3

    Great job. You make it looks easy but it’s not. It takes time to get there👍

  • @carlsmith5919
    @carlsmith5919 Před 8 měsíci +3

    I was starting to wonder when you were going to lay down so you can reach that screw. I hate those units, they have so limited hand space behind the line set. I worked one a while back, where someone replace both relays😮😮 with contacts, in that small space.

  • @CommercialGasEngineerVideos
    @CommercialGasEngineerVideos Před 8 měsíci +2

    Another good video

  • @robalexander7348
    @robalexander7348 Před 8 měsíci +3

    A nice fix Curtis, and so good to see a new clean filter change 👍 Au

  • @treyconner1991
    @treyconner1991 Před 8 měsíci +2

    You can never have to many flashlights. 🤙🏻

  • @odc43054
    @odc43054 Před 8 měsíci +3

    I had an ECM fan motor on a 10 year old Payne package unit that would continue to run even with the control wiring removed. Motor had to be replaced. Bad electronic brain.

  • @woodystokes1543
    @woodystokes1543 Před 8 měsíci +3

    Nice work 😊

    • @HVACGUY
      @HVACGUY  Před 8 měsíci +3

      Thanks 😄

    • @woodystokes1543
      @woodystokes1543 Před 8 měsíci +2

      @@HVACGUY you’re welcome
      I hate that they run he line set in front of the control panel.

    • @bobboscarato1313
      @bobboscarato1313 Před 8 měsíci +2

      @@woodystokes1543 Pretty poor design for downflow heater; however on the right side they have plenty of room to run the refrigerant line set and the drain line!

  • @sergiohernandez4163
    @sergiohernandez4163 Před 8 měsíci +1

    Them mobile home units sequencers always confuse me lol. I'm just a beginner on working on mobile home furnace

  • @RossTheGenMan
    @RossTheGenMan Před 8 měsíci +2

    Nice work and Explanation. Not sure if there was a filter in the door before you started?

    • @HVACGUY
      @HVACGUY  Před 8 měsíci +2

      No there wasn’t

  • @harrydickson4575
    @harrydickson4575 Před 8 měsíci +4

    👍👍👍

  • @mos8541
    @mos8541 Před 8 měsíci +3

    the oooole 9340...

  • @bendimaculangan2236
    @bendimaculangan2236 Před 8 měsíci

    Can u recommend an honest tech right here in pinellas county, Florida?

  • @jamierushing
    @jamierushing Před 8 měsíci +2

    Hi bro from west Alabama

  • @fernandobazan829
    @fernandobazan829 Před 8 měsíci +3

    Can’t see what your explaining with those wires i guess camera angle is off what controls that relay? The thermostat or the pcb?

    • @HVACGUY
      @HVACGUY  Před 8 měsíci +3

      Thermostat

    • @fernandobazan829
      @fernandobazan829 Před 8 měsíci +2

      so basically the thermostat send a call 24 V two the sequencer the sequencer send the 24 V to that peanut relay to turn the fan on. Also the thermostat could send 24 V to turn on the air conditioning and also turn on the fan from that same relay, so if that relays stock the fan to beyond all the time, no matter what good job

    • @user-su5ft8lc9q
      @user-su5ft8lc9q Před 8 měsíci +1

      Dr Curtis is on the job he fixes ot the first time. Unlike Medical Doctors that just keep you coming back to run up your bill.
      Lawyers, Doctors, and Weathermen, should be paid on whether the do the job right the first time. Most every other profession gets paid only if they fix it right the first time. That's why they all it a practice, and want paid any way.

  • @GodisAgapelove4172
    @GodisAgapelove4172 Před 7 měsíci

    If this doesn’t get fixed will it cause an increase in my electric bill?

  • @fernandobazan829
    @fernandobazan829 Před 8 měsíci +3

    One more quick question what are you calling a sequencer?

    • @fernandobazan829
      @fernandobazan829 Před 8 měsíci +3

      never mind I looked it up I call it a heat relay thanks anyway ur a smart tech

    • @bobboscarato1313
      @bobboscarato1313 Před 8 měsíci +5

      It brings in one heat strip at a time the reduce power surge!

  • @karellodewijks4971
    @karellodewijks4971 Před 8 měsíci +2

    😊😊👍👍

  • @steveurbach3093
    @steveurbach3093 Před 8 měsíci +5

    What is with the seriously dirty filters?

  • @kylemason5951
    @kylemason5951 Před 8 měsíci

    Could be the blower module or relay