PAANO MAG-INSTALL NG SERVICE ENTRANCE PARA SA BAGONG KUNTADOR NG MERALCO.. MISTER CORBI..

Sdílet
Vložit
  • čas přidán 27. 08. 2022
  • PAANO MAG-INSTALL NG SERVICE ENTRANCE PARA SA BAGONG KUNTADOR NG MERALCO.. MISTER CORBI..
    #Meralco #ServiceApplication
  • Auta a dopravní prostředky

Komentáře • 72

  • @michaelvillegas5742
    @michaelvillegas5742 Před 3 měsíci +1

    13 years na lumipas hindi na ako nkagawa sa electrical industry. Pero gusto ko bumalik kaya nag reveiw ako sa youtube at ito nga madami na changes pero almost same lang.. nice video very understanable..thanks lods

  • @rowelIgnacio-pn1jz
    @rowelIgnacio-pn1jz Před 7 měsíci +1

    Thank you sapang demo sir naiintindihan Kona yung line side Yun pala yung dalawang wire na nang galing sa service entrance tapos yung load side power na sa bahay gets kona

  • @ohnarjuarez849
    @ohnarjuarez849 Před 10 měsíci +1

    Napaka husay malinis ang pag install goodjob paps👍👏

  • @hahahaha4186
    @hahahaha4186 Před rokem +4

    boss base on Phillipine Electrical Code.#8 thhn wire ay hangang 40A CB lng dapat.kung 60A CB mo dapat #6 thhn ang gamitin mo

    • @bokiofficial2023
      @bokiofficial2023 Před 11 měsíci

      Oo nga jn ako nalito naisip ko tuloy pwede pla na maliit ng konti ung wire kc dapat ung #8 for 20amp 30amp hanggang 40amp lng pag 60amp na #6 dapat db tqma po b ako?

  • @ReyOrande-qy5ht
    @ReyOrande-qy5ht Před rokem +1

    Galing nman

  • @rowelignacio-g5i
    @rowelignacio-g5i Před 19 dny +1

    Yung line side sir pa punta nayon sa service drop nang meralco tama ba? Tapos yung loadside pumasok sa bahay

  • @gmcelectricalelectronicsse8575

    Sir mas maganda parin po ung orihinal n installation ng service entrance, namiminimize kapag ganun, medyo messy yang tingnan, dapat po s taas ng box mo binutas tapos RSC n nipple ang gagamitin, may available po s market n fittings na adaptor para dyan s ibabaw ng box na meron ng rubber gasket fittings,

  • @bryanlaido1460
    @bryanlaido1460 Před 4 měsíci +1

    Saan po tinatap ang ground sa meralco sa service drop

  • @emilianamariaapostol8391
    @emilianamariaapostol8391 Před 2 měsíci

    Hello po ung loading galing service entrance papunta sa house breaker po pwd gumamit ng flexible hose na 3/4?thank u po

  • @rowelignacio-g5i
    @rowelignacio-g5i Před 19 dny

    Sir bakit yung iba ginagawa sa nema3r yung load side na papunta sa bahay sa lupa nila pinapadaan?

  • @RolandoRedondo-su5el
    @RolandoRedondo-su5el Před měsícem +1

    Bolt on po yung breaker tama po ba?

  • @normiesomoso6022
    @normiesomoso6022 Před 2 měsíci

    idol wala kaman lang sinabi kong ilang ampers ang breaker na nilagay mo sa malapit sa metro.

  • @levyyjose6114
    @levyyjose6114 Před rokem

    Ser nag lilipat po ba kyo ng contador ng meralco nais kopo sanang palipat Ang amin.. sapang palay bulacan po area nmin.

  • @winniecortez9621
    @winniecortez9621 Před rokem

    Sir Gud day Po.Gusto ko Po ksing ilabas ang meter base ko sa may gate po.Need ko pa Po bang magpa alam sa meralco

  • @masterbrook0358
    @masterbrook0358 Před 10 měsíci

    Sir #8 po ung ginamit nyo na wire? Ilan Amphere po ba kelangan para sa circuit breaker kapag #8 po ng ginamit na wire? May naka depdende poba Yun?

  • @rowelIgnacio-pn1jz
    @rowelIgnacio-pn1jz Před 7 měsíci

    Kapag poba naka off yung CB sa bahay wala napo bang power yung service entrance kapag nag wiring ka

  • @chasefrancis2743
    @chasefrancis2743 Před 3 měsíci +1

    idol, ask ko lang sana. saan kinabit ng meralco ang white wire n para sa ground. diba two lines lang po ang galing sa meralco? ty

    • @MisterCorbi
      @MisterCorbi  Před 3 měsíci

      Wala Po.. naka-hang lng po un sa TaaS..

  • @benignoperan5643
    @benignoperan5643 Před rokem

    sir from mtr.base to nema ilan inches ung sukat?

  • @adriancesarp.quilon5089
    @adriancesarp.quilon5089 Před 11 měsíci +1

    Sir, Bibilhin dn ba ung meterbase?

  • @mj25ize
    @mj25ize Před rokem +3

    ser.. pag 75 amp na nema 3r
    pwede po ba size 8 na wire sa line side..salamat

    • @MisterCorbi
      @MisterCorbi  Před rokem

      depende po sya sir sa compoutation po ng schedule of loads..

  • @purecountrycrawler158
    @purecountrycrawler158 Před 11 měsíci +2

    Saan mo kinabit ung ground wire s taas ng service entrance bandang goose head..... Meralco b mag tatap noon? Tas s nema box nk tap din b xa s ground Gaya ng s kuntador?

    • @MisterCorbi
      @MisterCorbi  Před 11 měsíci +1

      sa taas naka-hang lng po ang ground.. sa nema3r nakatap o nakadikit sa case niya.. thanks..

  • @valdayuday4054
    @valdayuday4054 Před 11 měsíci

    Boss Anong sukat Ng meter base from flooring to center of meter base

  • @edasuncion2250
    @edasuncion2250 Před rokem +1

    Ka corbi, from nema sa load side papuntang main service breaker, inside the house, pwede bang gumamit ng #12 na wire?

    • @MisterCorbi
      @MisterCorbi  Před rokem

      hindi po sya pede sir.. number 8 p rin po sya papuntang 40 A Main Circuit breaker sa loob ng bahay..

  • @rowelignacio-g5i
    @rowelignacio-g5i Před 19 dny +1

    Yung load side ba nang nema3r sir papunta sa Maine breaker nang Bahay tama ba?

  • @VinceJiojandexuosJaime-ve2rl

    Ang linis po ng pagkakagawa niyo ng service entrance sir.
    As ko lang po, lahat po ba ng materials sa service entrance sir kailangan approved ng meralco?
    At possible po ba na mareject sa inspection ni Meralco if ang materials na ginamit ay hindi pasado sa standard ni Meralco?

    • @MisterCorbi
      @MisterCorbi  Před rokem

      salamat Po sir.. opo may pagkakataon po n mareject ang service entrance kapag Hindi Po akma sa standards ng meralco ung pagkaka-install ng service entrance..

  • @fredericktaaycura7542
    @fredericktaaycura7542 Před měsícem +1

    Pwede po ba na dalawang metro ang gagamit ng ground rod o dapat solo bawat metro. Salamat po

  • @edwinsalamera
    @edwinsalamera Před 2 měsíci

    Bawal n po ang elbow

  • @alvinrivero2166
    @alvinrivero2166 Před 8 měsíci +1

    boss yung neme outdoor panel kailangan bang nasa ilalim lagi ng kuntador kasi nasa labas sa amin e

    • @MisterCorbi
      @MisterCorbi  Před 8 měsíci

      yes po sir .. dapat po laging nasa ilalim ng kuntador..

  • @joeben6834
    @joeben6834 Před rokem +1

    Bos, ok lng ba straight connector un ba ung ginamit mo ok lng ba sa meralco ? at my na bibili bang IMC na maiksi ang sukat? Wala kc akong pang thread ng IMC. Thanks

    • @MisterCorbi
      @MisterCorbi  Před rokem

      yes pede po straight connector.. 10 feet po maximum sukat ng IMC.. need niyo po tlga magputol if kelangan po ninyo ng maiksing sukat.. thanks..

  • @allangerpacio8209
    @allangerpacio8209 Před rokem

    boss pwede b magkabit ng service intrance khit ndi electrician balk ko kc ako na gumwa nung samin bgung kuntador

    • @MisterCorbi
      @MisterCorbi  Před rokem

      pwede nman po sir.. pero advise ko p rin po magsama n lng po kayo ng magiging partner po ninyo n electrician.. parang ka-buddy niyo po sir..

  • @jhong2203
    @jhong2203 Před 15 dny +1

    Ok lang po sa meralco pvc gamitin sa ilalim ng metro?

  • @winsondelosreyes
    @winsondelosreyes Před rokem

    Boss Corbi nagkakabit po ba kayo ng ganyan ? Cavite Area po kasi ako naghahanap po ako ng magkakabit ng ganyan sa nilipatan namin na bahay ee, di ko po kasi alam ang gagawin

  • @mateolimbaro9509
    @mateolimbaro9509 Před 8 měsíci +1

    Sir Ang tanong ko Kung line to line o line to ground Yung ginawa ninyo

  • @ricardoserain3508
    @ricardoserain3508 Před rokem

    boss ung meter base b bi2lhin b un s meralco

  • @mangrove1925
    @mangrove1925 Před rokem +1

    Ano po ang wisdom reason kung bakit sa ilalim ng nema3r pinadaan ang wire gayon wala akong makitang deperensiya maliban sa mas maigsi yong wires kung sa ibabaw idinaan, please!

    • @MisterCorbi
      @MisterCorbi  Před rokem

      actually ung meralco po paiba-iba ng rules.. naguguluhan din po me sa kanila...may nakikita po ako binutasan sa ibabaw ung NEMA 3r pero tapos approve nman.. tapos ung iba hindi inapproved dapat daw sa ilalim..

    • @jovencrissolis9652
      @jovencrissolis9652 Před rokem +1

      sa ilalim talaga pu yan dapat mag butas kasi outdoor yan iwas basa po sa loob, pag sa taas ka mag butas at inaproved ng meralco kailangan mu lagyan ipoxy o yung pan dikit para di ma mapasukan nga tubig sa loob tnx

    • @rolandoaguirre5591
      @rolandoaguirre5591 Před rokem

      reason is sa pagkakaalam ko kaya pinalitan ng nema 3r kasi madaling pinapasok ng tubig yung walang nema 3r kaya nag sho short circuit

  • @tensiletechnologies5464

    Sir corbi paano Po mag wiring Ng net metering yong galing sa output Ng inverter papunta sa REC METER

  • @user-jx5gq7nu5n
    @user-jx5gq7nu5n Před 8 měsíci

    Sir ok lng ba magkaiba size ng wire sa service entrance ?

    • @jaspersalmorin6232
      @jaspersalmorin6232 Před 6 měsíci

      Much better same size ng wire. Pag maliit isang wire may tendency na masunog yon pag may load na

  • @BonjoVee6161
    @BonjoVee6161 Před rokem +2

    Sir magkano singil niyo sa service Entrance.

    • @MisterCorbi
      @MisterCorbi  Před rokem

      pag straight ung pagkakabitan sir pwede n po sa 3500..

    • @BonjoVee6161
      @BonjoVee6161 Před rokem

      Sa Metro Manila kayo ?

  • @hopeheaven07
    @hopeheaven07 Před rokem +1

    ano pong procedure pag dadaan sa contractor? iinspect pa din po ba ng meralco?

    • @MisterCorbi
      @MisterCorbi  Před rokem

      yes po.. inspect p rin po ng meralco..

    • @ginamasalta7100
      @ginamasalta7100 Před rokem

      May papel pa po ba nees ipakita sa meralco para po silay makapag inspect? Sana po masagot

  • @leamanalac3172
    @leamanalac3172 Před rokem +1

    mga ilang weeks po ang hihintayin sa paglagay ng kontador,salamat po

    • @MisterCorbi
      @MisterCorbi  Před rokem

      magandang araw po.. depende po mam if kaya po ng as much as 1 day, kinabukasan po pede niyo n Po kontakin ang meralco for inspection at pag nakapasa at ok n po lahat, schedule n po yan para makabitan ng kontador..

    • @leamanalac3172
      @leamanalac3172 Před rokem +1

      @@MisterCorbi dun sa schedule ng meralco po sa pagkabit ng kontador po ,aabutin po ng ilang days,weeks or months po ang pagkabit po,salamat po muli

    • @MisterCorbi
      @MisterCorbi  Před rokem

      pag naginspect n po cla, mga 3-5 working days po kakabit n po nila..

    • @leamanalac3172
      @leamanalac3172 Před rokem +1

      @@MisterCorbi thank you po sa pag reply

  • @manuelitoaranas5233
    @manuelitoaranas5233 Před rokem +1

    Ok lang b khit walang ground wire?

  • @lakwatserongpinoyfse4318

    Ang sagwang tingnan sa totoo lang..pasensya na