Komentáře • 31

  • @user-cf7dw2ds7p
    @user-cf7dw2ds7p Před 11 měsíci +1

    God is good all the time.☆
    From: basey samar

  • @SAMWEYVLOG
    @SAMWEYVLOG  Před rokem +1

    Thanks

  • @renzofficial2435
    @renzofficial2435 Před rokem +1

    Sending support master ingat po

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před 11 měsíci

      Thank you sir renzofficial. Ingat po lagi.

  • @jeffreym7222
    @jeffreym7222 Před 2 měsíci +1

    yang pump control nyo po All in one n po yan..Ano pa silbi ng pump conrol mo kung nilagyan mo pa ng float switch????yang pump motor mo bah ang ngkakarga ng tubig s tanke o humihigop ng tubig palabas?kaya nga my auto control yang pump mo pra mag automatic ON/OFF ang pump motor pag ma detect nya n may gumagamit s linya o kaya wla, at ma detect din ng auto control mo kung wlng lamang tubig ang tanke mo, yang pump motor hnd gagana.

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před 2 měsíci

      Yes Sir all in one na po yang APC.kayang malaman ng APC kong Wala ng tubig ang tanke at kong Wala ng mahigop o dumadaloy na tubig sa tubo.. Dina gagana kapag ganun. kaya ko lang naman nilagyan ng float switch para mamaintain ko yong level ng tubig bago umabot ang tubig sa May Check valve. Sa ganitong paraan maiiwasan na makahigop ng hangin ang motor para iwas din na laging ng beblade.

  • @user-km6hk5qf5i
    @user-km6hk5qf5i Před 4 měsíci +1

    Boss ask lang po! Yung motor ko is 1.5 HP kinabitan ko ng APC at float switch ngayun pag start a andar siya pag about ng 5 second ma off ang motor salamat sa sagut

  • @PaternoJrPadua-vt7ef
    @PaternoJrPadua-vt7ef Před 2 měsíci +2

    diba sir kaya po malaman ng APC na wala na tubig na dumdaloy at papatayin niya kusa ang motor. Question po bakit po nag dagdag pa kayo ng Floater Switch?

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před 2 měsíci

      Yes tama po, kayang malaman ng APC kong Wala ng tubig ang tanke at kong Wala ng mahigop o dumadaloybna tubig sa tubo.. Dina gagana kapag ganun. kaya ko lang naman nilagyan ng floater switch para mamaintain ko yong level ng tubig bago umabot ang tubig May Check valve. Sa ganitong paraan maiiwasan na makahigop ng hangin ang motor para iwas din na laging ng beblade.

  • @Jesuswarnedus
    @Jesuswarnedus Před 7 měsíci +1

    Why don't you use a twist on wire splice.. inexpensive and reusable and holds better than tape with no sticky mess if you have to remove it. God Bless

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před 7 měsíci +1

      Good suggestion my friend, yes I will try that one for my next motor installation. Thank you for that good idea.

  • @loscuatroladosaquayard4634
    @loscuatroladosaquayard4634 Před měsícem +1

    Yung sakin po bakit di gumagana ang pressure gauge?sira ba?gumagana naman po ang APC

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před měsícem

      Sira na po siguro bossing or Baka barado na

  • @masantingchannel4459
    @masantingchannel4459 Před rokem +1

    Bossing, pwedi din po ba yang lagyan ng pressure switch Kahit na Walang automatic pump control? Alin po ba mas convenient na gamiting automatic control kapag ganyang pump motor? Salamat po sa reply.

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před rokem

      Oo Pwedi naman, parehas Lang function nyan pero mas maganda ang automatic pump control kapag ganitong water pump. Ang pressure switch kasi naka design yan sa pressure tank.kasi ma e aadjust mo pa ang cut off at cut on, unlike sa automatic pump control naka factory setting na yan.

  • @Gabrielguzmansantos
    @Gabrielguzmansantos Před rokem +1

    Sir Tanong ko lang about jet matic
    Ano po kayang sira kapag binubuksan namin yung gripo tapos umaandar agad ang motor ng tubig namin. Tapos pag pinapatay namin yung gripo nag-off din agad yung motor. Hindi naman siya ganon dati..salamat po sir😊

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před rokem +1

      Good day sir Gabriel, May pressure tank ba yang jet matic nyo? Kasi kapag pressurize ang jet matic nyo sure yan Wala ng hangin ang pressure tank nyo. Pero kong Wala naman pong pressure tank at automatic pump control gamit nyo talagang ganyan po sya every time magbukas kayo ng gripo sabay andar din ang motor.

    • @Gabrielguzmansantos
      @Gabrielguzmansantos Před rokem +1

      @@SAMWEYVLOG hi sir thank you for answering me..
      Opo sir mayroon po kaming pressure tank...
      Ilan beses na po namin siyang tinanggalan ng hangin pero ganon parin po siya

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před rokem +1

      @@Gabrielguzmansantos ilang liters po yong pressure tank nyo sir? Kasi po May bladder po yang pressure tank, dapat din po May precharge syang 1.5bat or 23PSI kasi kong Wala syang pressure or hangin sa loob ng pressure tank at puro tubig nalang pag bukas nyo ng gripo andar din kaagad ang motor. Same din ng pag sara mo ng gripo off din ang motor kasi po Wala ng air pressure sa loob ng pressure tank

  • @jennylyntan5191
    @jennylyntan5191 Před rokem +1

    Sir ano po kya problem ng deepwell nmin, hihigop po xa sa una, tapos nsa pumapalo n ng 40 psi, bigla nmn babagsak ang pressure?

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před rokem

      good day po mam, nawawalan po ba ng pressure at dina ulit aandar ang water pump nyo? kasi kong hindi na po ulit aandar ang water pump nyo pagbaba ng pressure ibig sabhin po may problema ang pressure switch nyo.or nakakasipsip na ng hangin kaya hindi tuloy tuloy ang andar ng water pump

    • @johnlennon1609
      @johnlennon1609 Před 6 měsíci

      @@SAMWEYVLOG helow po sir ano po b Ang kdlsang prblema po ng Gould's jet pump 1.5hp hndi po humihigop ng 2big , slmt po,

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před 6 měsíci

      @johnlennon1609 kapag hirap pong makahigop ng tubig ibig pong sabihin nagkakahangin o nakakasipsip ng hangin po yan, dapat pasingawij nyo po muna yong hangin para solid na tubig yong Mahigop

  • @arnoldrementezo3182
    @arnoldrementezo3182 Před rokem +1

    Boss bakit umiinit ang pump auto matic pump 1.5 hp

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před rokem

      Maaaring matagal mag cut off sir, saka Pweding pwersado na narin ang motor or undersize sya kaya umiinit na.

  • @user-km6hk5qf5i
    @user-km6hk5qf5i Před 5 měsíci +1

    How many horse power po boss?

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před 5 měsíci +1

      1HorsePower lang po yan bossing

    • @user-km6hk5qf5i
      @user-km6hk5qf5i Před 5 měsíci +1

      Boss Yung 1.5 HP pwidi po ba Hindi na gamitan ng magnitc contactor?

    • @SAMWEYVLOG
      @SAMWEYVLOG  Před 5 měsíci +1

      @@user-km6hk5qf5i oo Bossing, pwedi naman po na hindi na gamitan ng magnetic contactor.

    • @user-km6hk5qf5i
      @user-km6hk5qf5i Před 5 měsíci

      Salamat po sa sagut