Booster pump set troubleshoot in hindi urdu || operation of booster pump set in hindi urdu

Sdílet
Vložit
  • čas přidán 7. 09. 2024
  • / @skelectricalguru6363
    Here you will learn how to findout troubleshoots of booster pump panel pressure pump panel repairing how you can fix low water pressure problem anywhere in water field at plumbing and electrical problems
    • Fully automatic pump c...
    This video will teach you how to repairing booster pump set troubleshoot solution in hindi urdu
    pressure pump panel troubleshoot in hindi urdu
    If no water in your house how to fix
    Its full knowledgeable video it will teach you how to find the solution of no water pressure or no water in water field anywhere like home,shoping malls, offices, factories,shops,warehouses,and anywhere where using water.
    In hindi
    Pressuer pump panel ko kyse repair kare
    Booster pump repairing in hindi
    Booster pump or pressure pump panel's how to fix the troubleshoot or problems in hindi .
    Full etutor video after watch you can fix any kind of problems in water pump panel.
    Float switch fault how can fix
    Pressure switch fault how can fix
    Laching relay how to check in pump panel .
    Please subscribe my channel if you are new in my chaannel and like and comment how is my video comment in commentbox

Komentáře • 201

  • @elecontrolpanelworks9568
    @elecontrolpanelworks9568 Před 3 lety +5

    Bhaiya Booster pump ka Penal Wearing pe video Aplood kigiye plzzzzz

  • @AtaurRahman-bs3hm
    @AtaurRahman-bs3hm Před 3 lety +5

    I really badly want this video...Tha ks U so much..in this 5 min video ..you teach a lot about pump connection

  • @Gill_vlogs08
    @Gill_vlogs08 Před měsícem

    Very helpful information.
    Step by step troubleshooting bataya. Or fir usko kaise thik karna h. Vo bhi bataya.
    Thx sir

  • @highway430
    @highway430 Před 9 měsíci

    Very thank you very much sir you solved my problem I am very thankful

  • @aftabsayyed4033
    @aftabsayyed4033 Před 3 lety +2

    Bro superb information.
    But agar ap ek pura video panel or oski wrining keh sath banaoge to it's very very helpful yaar.

  • @vijaypratapsingh8762
    @vijaypratapsingh8762 Před rokem

    Very helpful video thank you sir

  • @bidhibhatti5116
    @bidhibhatti5116 Před 3 lety +1

    Very nice bro tnx infor

  • @vijaypratapsingh8762
    @vijaypratapsingh8762 Před 2 měsíci

    Aapane bahut acche se samjhaya thank u so Mach

  • @UAETravelTrip
    @UAETravelTrip Před 2 dny

    Good work brother 👍

  • @dilawarhussain6741
    @dilawarhussain6741 Před měsícem

    Very good explain

  • @fawazahmed7897
    @fawazahmed7897 Před 2 lety

    Good job Bhai good information

  • @rudalchauhan7000
    @rudalchauhan7000 Před rokem

    Good information sir thanks you sir

  • @mohammmedhanif496
    @mohammmedhanif496 Před 4 lety +1

    Very good my friend you bast master ❤️👍

  • @ghulammurtaza5735
    @ghulammurtaza5735 Před 4 lety +2

    Good

  • @1234eema
    @1234eema Před 2 lety

    Nice informative video

  • @kv848
    @kv848 Před 3 lety +1

    Expect great video from you again,. Thanks

  • @sunilkumar-ds5tf
    @sunilkumar-ds5tf Před 5 lety

    sir aap bahot achhese samjhate hai nice video make more

  • @shanakarumesh3097
    @shanakarumesh3097 Před 2 lety

    Super bro. Good explain

  • @mohammedhussain9687
    @mohammedhussain9687 Před 4 lety +2

    Thanks thanks thanks

  • @mukeshrathod6459
    @mukeshrathod6459 Před 3 měsíci

    Superb bro👌🏻

  • @arvindyadav6898
    @arvindyadav6898 Před 2 lety +1

    Very good

  • @khalamsalahudeen2748
    @khalamsalahudeen2748 Před 4 lety +1

    Use ful video.

  • @palsunilkumar7121
    @palsunilkumar7121 Před 2 lety +1

    Very nice

  • @user-nt2wj6ci3s
    @user-nt2wj6ci3s Před 9 měsíci

    Very good bro

  • @qasimkazmi786
    @qasimkazmi786 Před 2 lety +1

    Great video brother

  • @muhammadazkarulhaq2032
    @muhammadazkarulhaq2032 Před 4 lety +3

    Dear sir.
    Please can you make a complete video of wiring of this panel?All incoming and outgoing connections of panel including float switch,booster pumps,pressure switch and internal wiring of panel

  • @hearttouching8675
    @hearttouching8675 Před 4 lety +1

    Thank you so much. For this video

  • @Gurdeepsingh-dx9ql
    @Gurdeepsingh-dx9ql Před 3 lety +1

    Nice video

  • @satishbalodi4576
    @satishbalodi4576 Před 2 lety

    Good information sir 👍👍👍 thankyou

  • @rajeshjadhav00
    @rajeshjadhav00 Před 3 lety +1

    Very nice video ... 👌👍

  • @taimoor9375
    @taimoor9375 Před rokem

    Great video

  • @anilsahooofficial8054
    @anilsahooofficial8054 Před 2 lety

    Very informative 😍😍😍🙏

  • @highway430
    @highway430 Před 9 měsíci

    Super sir

  • @taimoor9375
    @taimoor9375 Před rokem

    We need more video on water pumps related...

  • @maroofalikhan6210
    @maroofalikhan6210 Před 3 lety +1

    Nice

  • @majorsingh9131
    @majorsingh9131 Před 8 měsíci

    Buster pump ka full warinind and practical video bno

  • @umarhayat4432
    @umarhayat4432 Před 3 lety +1

    Salam bhai

  • @TrendingDrops3624shan
    @TrendingDrops3624shan Před 3 lety +1

    Thanks ☺️☺️☺️

  • @shahidjamal982
    @shahidjamal982 Před 3 lety +1

    Sir... booster pump ka control wiring ka v ak video bna do

  • @paulcatulay5614
    @paulcatulay5614 Před 3 lety +1

    How to wire the booster pump wye delta connection pls.. give me a compilation diagram sir thanks so much for your respond it..

  • @khalamsalahudeen2748
    @khalamsalahudeen2748 Před 4 lety +1

    Thanks bro

  • @user-gt9vi8hq9r
    @user-gt9vi8hq9r Před 5 lety +1

    Good
    And drawings also need explain.

  • @mohammedhussain9687
    @mohammedhussain9687 Před 4 lety +1

    Thanks thanks

  • @ramakantkushwaha5458
    @ramakantkushwaha5458 Před rokem

    Sumpump ka video banaye bhother

  • @mohammedyounus4608
    @mohammedyounus4608 Před 4 lety +1

    Thank u soo much for uploading this very useful information.
    Sir kabhi kabhi emergency mein koi fault rectify nahi hotha hai.
    Specially jab hum night duty pe hothey hai.
    Uss time night mein agar pump ko temporary start kaise karein??
    Please aysi koi information bhi share kare.
    Please reply me.
    Thank you.

    • @mohammedyounus4608
      @mohammedyounus4608 Před 4 lety +1

      Sir please reply tho kariye.

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Sorry bhai late reply ke liye 🙏
      Agar emergency me pump ko manual on karna hai to har panel ko hand pe chala sakte hai selector switch se waise ye bataye ki aap transfer pump ki baat kar rahe hai ya booster pump ki ?

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      1# Waise booster pump haito pressure switch se out honewala power direct pump ke contector ke coil volt par desakte hai .
      2# aur transfer pump ko auto me chalana hai to roof tank ka float switch ka outhone wala phase wire ko contector me de saktehai istarike. Se pump ko temporary automatic kar sakte hai koi doubt hai pooch sakte ho 😊

  • @salauddinmulla139
    @salauddinmulla139 Před 4 lety +2

    Thanks for this video... I have one question..why latching Relay stuck on middle ON OFF Direction. When I reset it's work after one or two days and again it's stuck same.how to solve this problem?

  • @nagrajbanban7804
    @nagrajbanban7804 Před 5 lety +2

    Sir,
    Please,
    Shall you make internal penal control diagram practically

  • @user-gt9vi8hq9r
    @user-gt9vi8hq9r Před 3 lety +1

    Bai
    float switch line me neutral reyekatho kaisaa tester me malum hoyakaa

    • @skelectricalguru6363
      @skelectricalguru6363  Před 3 lety +1

      Nutral hai to tester se kaam nahi hoga aap volt meter ya test lamp use karo

  • @arshadanees448
    @arshadanees448 Před 5 lety

    Or video bnao or information chiye booster pump ki panel wiring bnao sir

  • @mdanwar6367
    @mdanwar6367 Před 3 lety

    Sir laching realy ka drowing kaise kiya jata kaise esko 2 moter opreat karte hai pkz drowing me samjana sir

  • @simonkarre7746
    @simonkarre7746 Před 4 lety +1

    Sir latching really ke bare me ek baar praktikal batahiye sir karab hai ya sahi hai

  • @PKBGOLDAN
    @PKBGOLDAN Před 3 lety +1

    Laching relay ka wiring kaise karte hi

  • @sunilkumar-ds5tf
    @sunilkumar-ds5tf Před 5 lety

    sir isi panel ke control wiring aur power wiring pe ek video banaiye aur one by one explain karye jitne bhi saman isme use huwa hai unsab k baare me
    digram ke jariye please sir

  • @upkarsingh2802
    @upkarsingh2802 Před 4 lety

    Sir aap transfer pump & booster pump ke panel ke connection full vedio banaye please sir

  • @reazulkarim4820
    @reazulkarim4820 Před 10 měsíci

    Brother, my pump is not automatic, if you tell me what I can do, I will be benefited, thank you

  • @murshidofficial4540
    @murshidofficial4540 Před 3 lety

    SAR is painal Ka daigaram banake samjhaiye Puri wairing please

  • @adnansuleman5802
    @adnansuleman5802 Před 4 lety

    nice videos

  • @sheikhshafiq5528
    @sheikhshafiq5528 Před rokem

    Give more video

  • @Sdelectrical-d9q
    @Sdelectrical-d9q Před rokem

    Hello sir our company booster pump not working in auto but working on hand please make this video

  • @pramodkarkera7486
    @pramodkarkera7486 Před měsícem

    ❤️❤️❤️

  • @MuhammadAli-tw7fp
    @MuhammadAli-tw7fp Před 4 lety

    V nice

  • @upkarsingh2802
    @upkarsingh2802 Před 2 lety +1

    Sir booster pump ka curcuit diagram bataye

    • @skelectricalguru6363
      @skelectricalguru6363  Před 2 lety

      requirements k hisab se panels design kiye jate hai ismey basic cheez contactor kacoil volt aapko float switch pressure switch aur selector switch in sab se by pass karke guzarna hai

  • @damjibuchiya1373
    @damjibuchiya1373 Před 2 lety

    Dhaneyvadapaerikesancatarolkebaremebataiy🙏🙏🙏

  • @anwarck7260
    @anwarck7260 Před 4 lety

    11kw booster pump kelea kitha litter ka pressure tank chahiye

  • @sambarnaresh1291
    @sambarnaresh1291 Před 5 lety +2

    Please drawing ke sath wiring samjaho

  • @kulveerdhiman4761
    @kulveerdhiman4761 Před 2 lety

    Sir Esme ek aur relay hota hai sesa ka us ke bar me batay

  • @abdul10375
    @abdul10375 Před 3 lety +1

    Ye panel manually operate bhi ho raha he? Ya only auto

  • @khanshabahuddin2513
    @khanshabahuddin2513 Před 4 lety +1

    Sir ji kal mere sath ek ajeeb waqya pes ay
    Auto cut hone k baad pressure automatic release ho jata hai koi istemaal bhi nahi ho raha phir chalu hota hai release krta hai iska kya mtlb prblm kya ho sakti hai
    Blender problm ya kuch aur please suggest me

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Pressure tank ki hawa check kare aur Pump ke output line me NRV (non return valve) hotey hai uska kaam hai jab pump pressure banakar cut hota hai tab nrv pressure hold karta hai .
      Nrv bhi chek kare.
      Ji thank for watching my video

  • @something-new-for-you
    @something-new-for-you Před 3 lety +1

    Hi... Sir without latching relay how can be make a change over for booster pump

  • @surajmahato2336
    @surajmahato2336 Před 4 lety

    Sir yah panel ka full wiring diagram wala video banaye please

  • @shakeelahmad-jr2hy
    @shakeelahmad-jr2hy Před 4 lety +1

    Please show me flow switch connection in booster pump

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Agar aap contector use kar rahe ho to uske coil volt ko float switch se pass karte hue le jayen .
      Aur direct use kar rahe ho to pump ke line ya nutral ko float switch se pass katwate hue le jayen .
      Lekin agar apka pump 2 amp se zyada hai to float switch direct use na kare

  • @sunilkumar-ds5tf
    @sunilkumar-ds5tf Před 3 lety +1

    Sir, mera swimming pool ka filter pump hand mode me chalta hai lekin auto mode me nahi chalata hai. Aur Mai auto mode me chalana chahata hu. To mujhe Kya karma hoga? Please reply karma bhai g

  • @mughalmaan9686
    @mughalmaan9686 Před 3 lety +1

    Sir same penal h
    Par pressure switc kam krta h h
    Pr pupm bnd ni hota h

  • @arjualamalam4834
    @arjualamalam4834 Před 4 lety

    Transfer pum k baare m batayee sir please please please sir

  • @allauddinkhan3428
    @allauddinkhan3428 Před 4 lety +1

    Prssur jeyada hone pe keya kare

  • @yakubmugal7725
    @yakubmugal7725 Před 2 měsíci

    Bhai auto pe on krne ke bad 1 ya 2 mintis me band ho jati h moter kya problam hoga

  • @serajkhan5978
    @serajkhan5978 Před 5 lety +1

    Sir mera ek problem hai menul me motar chalta hai auto me karta hoon to moter nahi chalta hai plz kia problam hai

    • @rrjsr3218
      @rrjsr3218 Před 5 lety

      Float sw,, pressure sw,, laching relay ,, aur selector sw ka auto wala link ye sari cheezo ko one by one check kar ley

  • @manveersingh4045
    @manveersingh4045 Před 2 lety +1

    Panel drawings required,can provide me sir...

  • @israfilmeya3967
    @israfilmeya3967 Před 2 lety

    Selected shoes ko kaise sahi Kiya jaaye kaise pata chalega ki kharab hai sahi hai yah per lagata hun chalta hai motor ke band ho jata hai

  • @umarhayat4432
    @umarhayat4432 Před 3 lety

    Bhai Mera pas do pupm lagay ha or wo low level day rahy ha nahe wo hand par chlta ha nahe ato par sir plz kuch batao me bhot par shan ho

  • @ejazka9705
    @ejazka9705 Před 4 lety +1

    Need full diagram of control panel

  • @alammohammedbadresameer1233

    Sir booster pump 1bar se niche jane ke bad start ho raha h
    Kya fault ho sakta h?

    • @skelectricalguru6363
      @skelectricalguru6363  Před 3 lety

      Pressure switch open karke clean karo fir bhi same problems ho to P.Switch replace kar do

  • @shahzadakhan3786
    @shahzadakhan3786 Před 5 lety +1

    Floating switch ka connection kaise krte h panel me

    • @skelectricalguru6363
      @skelectricalguru6363  Před 5 lety +2

      Floting switch ka connection contractor ke coil volt ko jo supply ja rahi hai usey floting switch se pass karte huwey dena hai .
      Mai uspar bhi video banaunga jald hi ke float switch kyse connect karte hai

  • @israfilmeya3967
    @israfilmeya3967 Před 2 lety

    To selected shoes kharab hai ya kuchh aur problem hai

  • @arvindrawat1114
    @arvindrawat1114 Před rokem

    Bhai transfer pump ke bare mein batao transfer pump chal Nahin raha

  • @yogenlama3264
    @yogenlama3264 Před 4 lety +1

    Sir mera 1 problem hey Auto me chalatahu to alternet 3,4 second me change hote raheta hey kya problem hey plz bata digiye...

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Sir aapka pressure tank hold nahi kar raha isliye pump jaldi jaldi command le raha hai pressure switch se ...
      Pressure tank ka bladder change kijiye ya full tank

  • @muhammadzia2281
    @muhammadzia2281 Před 4 lety +1

    HP 10 HP transfer pump sometime auto not working sometime am hand hand 10 second after working auto please please in inform the problem thank you

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Bhai uska selector switch me problem ho sakta hai. Second option laching relay bhi kabhi kabhi kaam nahi karta hoga ye dono cheezo ko badal kar dekh lijiye

  • @trilokiyadav2798
    @trilokiyadav2798 Před 4 lety +1

    Sir mera buster pump dono motor on off on off continue pickup kar RHA hai kya fault ho sakta hai sir

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Sir ji aapka pump set me agar pressure tank hai to uska blader fat chuka hai aisi halat me pressure tank change karna hoga

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Pressure tank pressure hold karta hai tank bladder fat jane se pressure hold nahi hoga jiski wajah se pump jaldi jaldi on/off hoga

    • @premaramtholiya7348
      @premaramtholiya7348 Před 4 lety

      Sar mera pump on off on of hota paresar nahi bana raha h motor nahi Cal rahi h

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Ok aap pic send karo complete panel aur pump set ki

  • @khanjuma777
    @khanjuma777 Před rokem

    Bro hamary booster pump ka pressure switch bar bar kharab ho jata hai matlab pump khale chalta rahta ha I.

  • @arjualamalam4834
    @arjualamalam4834 Před 4 lety +1

    Booster pump ka 3 pump 1y1 nhi chal raha hai latching relay new reples karne k baad v nhi kamand nhi le raha matlab change nhi kar raha hi latching relay please help me sir please please please

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Bhaijaan laching relay ke A1 aur A2 par coil volt check kar jab pump cutoff hokar on hoga tab uski coil ko vilt nahi mil pa raha hai isliye vo changeover nahi ho raha

  • @arshadanees448
    @arshadanees448 Před 5 lety

    Kya iski full wiring bta sakte hai plz

  • @mdanwar6367
    @mdanwar6367 Před 4 lety

    Sir es ka drowning bataye

  • @MDSalim-uv5fe
    @MDSalim-uv5fe Před 2 lety

    Sir pump manual me chalta h. Auto me kyo nahi chalta

  • @sabahathussain3402
    @sabahathussain3402 Před 4 lety

    Please show panel control diagram

  • @shaqeelquraishi2407
    @shaqeelquraishi2407 Před 4 lety

    Bhai painal ki wiring kaise karte hai batao

  • @superman4294
    @superman4294 Před 5 lety +1

    I want to ask somthing

  • @simonkarre7746
    @simonkarre7746 Před 4 lety

    Sir aap bataya nahi latching realy karab hai ya nahi hai ho ek baar batahiye

  • @khanjuma777
    @khanjuma777 Před rokem

    Dono indicator pump trip dekha rahy hain kioun

  • @simonkarre7746
    @simonkarre7746 Před 4 lety

    Sir Kaise check karte hai Lachting really ho ek baar bata hi ye practical

    • @skelectricalguru6363
      @skelectricalguru6363  Před 4 lety

      Float switch up /dn karke check kar sakte hai dono pump auto mode me hona chahiye

  • @arshadanees448
    @arshadanees448 Před 5 lety

    Sir latching rely ka connection bta do plz.kaise karte hai

    • @skelectricalguru6363
      @skelectricalguru6363  Před 5 lety

      Thanks for reply i will make video for laching relay connection

    • @arshadanees448
      @arshadanees448 Před 5 lety

      @@skelectricalguru6363 or sir agar possible hai to 2 motor auto me kaise wiring karte hai.or..matlab sab usme ho..indicator sector switch..puch button...