How to fix a Master Space Heater

Sdílet
Vložit
  • čas přidán 13. 09. 2024
  • How to fix a Master Space Heater: This is just one of many things that could go wrong, the problem with some of these heaters is that the older models are not parts supported anymore. I probably should have replaced the filter but did not have one at the time stay tied for the next video on this, I did put a link for filter down below.
    Filter for the unit: Master Kerosene Heaters: amzn.to/3nZHibz
    Tools Used:
    Vacuum and Fuel Pressure Kit: amzn.to/37SMmce
    CRAFTSMAN Screwdriver Set: amzn.to/3nQMWgc
    Kobalt Tool Set: amzn.to/3pn9RQy
    B'laster 16-PB Penetrating: amzn.to/2WJpGF1
    Film Gear Used:
    Blue Yeti USB Mic: amzn.to/2GnK4Dl
    IPad Air: amzn.to/2Exopb8
    Soft-box Lights: amzn.to/2Ezg6M3
    AMIR Phone Camera Lens: amzn.to/2EwpT5K
    Sports Action Camera: amzn.to/2sQwh4Z
    Editing Equipment:
    Dell Latitude E6420 Laptop: amzn.to/2SHZc3I
    MacBook: amzn.to/2yjlLma
    Zelotes Mouse: amzn.to/2LKwJJQ
    Cyberlink PowerDirector 17 Ultra: amzn.to/2S2wFqS
    Contour ShuttleXpress: amzn.to/3amkISO
    Stay connected:
    Instagram - / channel.ron
    DISCLAIMER: This video contains Amazon affiliate links, which means that if you click on one of the product links below in the Description or in the video “Channel Ron” we’ll receive a small commission.

Komentáře • 44

  • @Le_Comte_de_Monte_Felin
    @Le_Comte_de_Monte_Felin Před 2 lety +1

    Thank you for this simple, easy to follow guide. I printed out the manual for my ProTemp PT-70T-KFA (70,000btu) heater and was going to 'logic my way' through it to figure out what was wrong but your guide put me on the scent of what was wrong from the get go. Previous owner had apparently put bad fuel, or old diesel, into it and yep - cleaning out the jet led me to find several chunky bits of 'fuel'.
    While I was in there I installed a spare fuel filter & zip-tied it away from heat & the fan.... hit the switch & she fired right up!
    Many thanks!

  • @AintRubbinAintDubbin
    @AintRubbinAintDubbin Před rokem +1

    I wish I found this before I started replacing parts, thank you for the video. Was very helpful. Cleaning my nozzle did the trick!

  • @queuing89
    @queuing89 Před 2 lety +2

    You will get a more accurate reading by testing the pressure at the test point, blocking the pipe like you did only tells you the max pressure the pump can supply, you need the air flowing through the system and out the nozzle to set the correct pressure.
    I had a similar problem with my own B70 model and after too many hours spent cleaning, testing and adjusting everything more then once, it turned out to be a hairline crack in the plastic cover where the pressure adjustment screw is located, when the screws were tightened the crack got wider and it lost all the air pressure, i super glued it and is now working perfect

  • @leszekm4414
    @leszekm4414 Před 3 lety

    Thenks for this film. Thanks to you i repair my machine. 👍👍

  • @Smith22198
    @Smith22198 Před rokem

    Thank you for all the help!

  • @markkallstrom5672
    @markkallstrom5672 Před 8 měsíci +1

    Kallstrom Sweet Corn here , I think I may have a fuel problem . My heater is 34 hears old [ we bought new ] has not been used in approx. 15 years , has some rust in tank . [ how did you get rid of rust in tank ?

  • @KEWS54
    @KEWS54 Před 2 lety +1

    Thanks!

  • @thomastheterrific3051
    @thomastheterrific3051 Před 3 lety +1

    Please do a battery test with sunbeam with wheel stunt rover

  • @drewdubtv7006
    @drewdubtv7006 Před 2 lety +1

    Hi Ron
    You video has come in great as mine was doing the same cleaned it out and it's firing lighting and going outside think the pressure is wrong butni don't have guage . Mine says 2.5 psi is there anyway you could tell me how many turns from all the way in it might be please, I'm in the UK and delivery of a guage is 7 days to me

    • @channelron3593
      @channelron3593  Před 2 lety +1

      Ok, I just got back from checking and this unit was about 5 turns out but they are all different based on what may be worn out try that. good luck.

  • @lump42104
    @lump42104 Před 9 měsíci +1

    If I am not getting fuel what then I cleaned nozzle go nothing I took fuel line off nozzle manifold start nothing coming out of fuel line

    • @channelron3593
      @channelron3593  Před 9 měsíci

      It could need a pump kit? I think it is this one: amzn.to/473Ck3a

  • @jimjordan5630
    @jimjordan5630 Před 3 lety +2

    Just curious, why do you continuously plug and unplug the unit instead of using the on-off switch?

    • @channelron3593
      @channelron3593  Před 3 lety +1

      This unit does not have one, just a time out reset button.

    • @jimjordan5630
      @jimjordan5630 Před 3 lety

      @@channelron3593 Gotcha! Thank you for your response!

  • @stanleybrown1151
    @stanleybrown1151 Před rokem +1

    Is this setup the same on the 140's? Mine is doing the same but I found both fuel hoses were bad. I replaced them and still doing the same.

  • @alsan5902
    @alsan5902 Před 2 lety +1

    Can you use brake cleaner? To clean it

    • @channelron3593
      @channelron3593  Před 2 lety

      Good ? I would think it would be fine, I know that is some nasty stuff, ware gloves (:

  • @John-vf9py
    @John-vf9py Před rokem +3

    Everything you did was wrong. If you pulled the air line then it wouldn't pull fuel so you could have left the igniter wire connected. If that grounded out you ran a change of frying the high voltage ignition. Air pump pressure needs to be checked from the rear test port with the line connected to the nozzle. Never saw anyone ever use PB blaster as a cleaner?

  • @ahhason
    @ahhason Před 2 lety +1

    I have a master 80,000 BTU and when I plug it in the green light comes on but the fan doesnt start. Think the thermostat is busted or what could be the issue?

  • @MrShmeeboy
    @MrShmeeboy Před 2 lety +1

    I have a Master 135K BTU unit that came with the farm I bought. The unit turns on and heats but it sputters a lot. It has a gage on it and reads 5.5 psig, which it is what the plate says it should be. The fuel is probably old so I realize that. But is there something else I need to check?

    • @channelron3593
      @channelron3593  Před 2 lety

      Think you got it Fuel,, make sure you use #1 very expensive but when you need it its worth it.

    • @TheChewy78
      @TheChewy78 Před rokem

      Anybody #2 diesel in these spark ignited heaters?

  • @Lftd_bronco
    @Lftd_bronco Před 2 lety +1

    Hello my heater similar to yours stays on for about 10 seconds then shuts off I have to reset it in the back for it to turn on then does the same 10 sec later

    • @channelron3593
      @channelron3593  Před 2 lety

      Fuel? igniter? Fuel Pressure? they all are connected. also, I'm not sure If I said in the film I only use #1 in this unit. Sometimes the fuel line from the tank could be clogged just enough to give problems and a cracked fuel line and also check the filter in the tank, good luck

  • @tyler560
    @tyler560 Před 2 lety +1

    What kind of gauge are you using ?

    • @channelron3593
      @channelron3593  Před 2 lety

      Should be in description but just in case amzn.to/3nWCXbL

  • @allentravis4506
    @allentravis4506 Před rokem

    What if it's not firing

  • @pennyhopkins9223
    @pennyhopkins9223 Před 2 lety +1

    I have a two burner space heater in my bed room .it has worked fine for years.this morning the pilot lite want stay on

    • @channelron3593
      @channelron3593  Před 2 lety

      First of all you should not have them inside? make sure you open window a bit. also use good fuel, that unit is different then what I am working on.

  • @mrgringo6859
    @mrgringo6859 Před 2 lety +1

    Ron I have a master 115,000 btu heater. I'm have a issue, with the top cover off it runs perfect, as soon as I put the top cover on it dies. Any suggestions?

    • @channelron3593
      @channelron3593  Před 2 lety

      Yes check the presser with gage, and the other is the nozzle could be dirty or
      worn seems wired but have had that problem to. replace the nozzle and it fix it. also I always run just #1 My neighbor used it and put #2 in it and it did not like it.

  • @pennyhopkins9223
    @pennyhopkins9223 Před 2 lety

    Ii need to know how to keep my reddy heater pilot light lit?

    • @channelron3593
      @channelron3593  Před 2 lety

      This unit does not have a pilot light? I am thinking you are talking about something different.

  • @danieltamay4328
    @danieltamay4328 Před 3 lety +1

    Do you sell parts