Bahut slow chlte ho thoda fast ho jao, hr baat 5 to time repeat mt kro CZcams par repeat nhi krna , kyo jis ko krna 10baar repeat kre yeh suvidha hai. AAP please
Sir mai aapko dil se thanks sir mai hamesha fridge mai gas dalne time chok problem mai fas jate the aur din din phar fas jate the aapne jo bola oil se chok nahi hoti hai aur vecum pump se karne se chok nahi hoti hai aapka video dekh ke phalas nahi marte hai vecum pump se 30 minet tak vecum karte hai tab se kabhi chok nahi hota hai aur kam bhi turant hota hai kabhi chok pe nahi phaste
Sir 4 sal se sirf ac ka kam karta hu.. Frezzz ka kam kabi kiya nhi... Na kisi ne Btya. Muje...... Ap ki video dekhe k bad ... Ab me frezz ka kam kauga ... Thanks sir
Ac me ye clear karna padta hai fridge me nahi Ek baat bata den ki jo bhi cheejen batayi jati hai experience ke base pe batayi jati hai agar iss tareeke se karenge to success ho jayenge Jada soch vichar karne ki jaroorat nahi hai
Nitrogen ho to flux kariye warna vaccum pump se vaccum kar ke gas charge kar dijiye Uss oil se chocking nahi hogi Ye jo cheeje mai aap logo ko batata hun ye aap logo ko kuchh alag lagti hogi lekin yahi hakeekat hai
Acha information lamba hota hi hai.. Vacuum is very important. jo ki koi technician nahi karte AC ho freeze ho. Na hi N2 salte n hi vacuum kare phir bhi 3500 lete gas charging karne ke chhote wale freez me R134
Yahi cheej pahle hamate mind me bhi tha to jabtak pata nahi tha to khoob flaxing karte then aadha ghanta ek ghanta tak lekin jab ye cheej engineer ke jariye pata chala to tabse kabhi bhi falxing nahi kiye aur firf vaccum pump se vaccum karte hain aur gas charge karte hai ek bhi fridge ac choke nahi hoti hai lekin vaccum pump se vaccum karna compressor se nahi
Compressor ko thoda bahut chalane men koyee problem nahi hai Ab agar ekdam nahi chalayenge to hosakta hai ki compressor ka pressor down ho iss liye cooling nahi kar raha tha to aap bina chalaye filter jod kar vaccum karke gas charge kar denge to pressure down ki wajah se cooling nahi karega aur aap presan ho jayenge Compressor ko agar khule men 3 4 minute chalate hai to to iss se koyee problem nahi hai iss rule ko follow aap bhi kiya kariye
Kahe ko aap bol rahe ho sar angutha se check karoangutha se ko bhi pata hi nahin chalega Kyunki capillary se maximum 300 PSI se gas pass Hota Hai angutha hat jata hai 80 PSI mein iske liye pressure gauge Lagana jaruri hai pressure gauge Mein maximum450/500 dekhne ka
Ye ek short cut tareeka hai compressor ka pressor check karne ka Dekhiye jab aap gas charge karenge to har baar gause laga kar compressor ka pressur check karne me problem hoti hai aur compressor ka pressure jaldi down bhi nahi hota hai Ye tareeka bahut achcha hai jab aap kam karne lagenge to samajh me aa jayega Pahle ham bhi isi problem men thhe but jab kaam karne lage to dab samajh me aa gaya
Cake chillar me gaish 134 charj karte time Section pressor lagbhag sahi rahta hain par standing pressor 25 psi se jada nhi jata hain kya problem h plz.. Help me bro apna number de dijiye
Thanks you bro aesy Video bnate rhiye
Bahut slow chlte ho thoda fast ho jao, hr baat 5 to time repeat mt kro CZcams par repeat nhi krna , kyo jis ko krna 10baar repeat kre yeh suvidha hai. AAP please
Sir mai aapko dil se thanks sir mai hamesha fridge mai gas dalne time chok problem mai fas jate the aur din din phar fas jate the aapne jo bola oil se chok nahi hoti hai aur vecum pump se karne se chok nahi hoti hai aapka video dekh ke phalas nahi marte hai vecum pump se 30 minet tak vecum karte hai tab se kabhi chok nahi hota hai aur kam bhi turant hota hai kabhi chok pe nahi phaste
Nice video siar
Sir 4 sal se sirf ac ka kam karta hu.. Frezzz ka kam kabi kiya nhi... Na kisi ne Btya. Muje...... Ap ki video dekhe k bad ... Ab me frezz ka kam kauga ... Thanks sir
Good job 👍
Very good information sir 👍👍👍👍
Thanks sir
Nice sir🙏
Very nice sir 👍
Thanx cold cream bhaiya
Samsung singal dor invatar fridge ka capalari paep kis tarah chanj kare
Good all the best
Thank you so much sir ji 🙏
Very good 👍❤❤🎉 sir ji
sr thxxxx
Ase dhere batao sir achha hai
Good idiya
Sr Deep freezer me gas charge ka video baniye
Good 👍
Thanks
👍👍👍Yeh video kafi helpfull hai
Supar
kisi bhee fridege me kitna psi isko detels me batai
Sir aaP ka video bhut Aachcha hai Azamgarh me kha hai
Hi
Sir ungliku condenser pipe ku thabaanese compressorka pumpingtho pathaa chaljaayenga.lekin compressor backmaarthahai yaa nahi yeto pressure gauge lagaanesehe pathaa chalega.haina sir?
Ac me ye clear karna padta hai fridge me nahi
Ek baat bata den ki jo bhi cheejen batayi jati hai experience ke base pe batayi jati hai agar iss tareeke se karenge to success ho jayenge
Jada soch vichar karne ki jaroorat nahi hai
@@kareemtechnicalmind8172 achi baat hai sir g.iska matlab koibi kuchbi sawaal nai poochneyka.yehi haina sir aapka kehna? Compressor kabi achaa pumping karthahai.lekin thurand back martheyhai.tho kya aisahi systemme jodthena. Phir customer shikayat karenga bhai cooling nai aata.phir jaavo brazingku hataavo phir check karo aur phir bolo customer se saab aapka compressorka pumping sahi naihai.yeto bahoot achaa rahengana sir?
@@shafimehar4506sahi kaha Bhai bina gauge metre ke sahi nahi cheque ho pata compressor
Good
Feeze ke R600ka compressor ki jagh me r134 ka compressor laga sakte hai ya nahi agr laga sakte hai to gas charging kaise karte hai
Same process
Sir compressor me thik se vacuum hota hai ki nhi dusre comprssor se
Nahin aur company compressor se vacuum karne ko reject karti hai vaccum sirf vacuum pump se hi achchha hota hai
sir,freezer,likij, video,Bana,sir
hydrocarbon blend ges ka back pressure kitna hota hai
8 से 9 psi
80_90
Main is time saudi me kam kar rha hu plz. Help me
Kya problem hain usme
Vaiya moje helf kordona please.ak fridge 30 minutes chal ne bad chock horaha hai.30 minutes ice aaraha hai
मोइसचर चोकिंग है अच्छी तरह से वैक्यूम करिये वैक्यूम पंप से फिर गैस चार्ज करिये प्रोबलें ख़तम
Sir ji presser nai dakhaya gase meter me 0 pis dekhata hai.20 psi kaise hoga bina campresser k barikse samja deje sir. Vidio me
Ok
Sar ji board ka screen shot lene ke liye thoda Bagal Ho Jaya Kariye last mein
Ok
Sir ac freez ka cors kitne din ka hota hai kitna fees bataye sir
16500
Sir agar cooling pipe me oil chala jaye to kya kare
Nitrogen ho to flux kariye warna vaccum pump se vaccum kar ke gas charge kar dijiye
Uss oil se chocking nahi hogi
Ye jo cheeje mai aap logo ko batata hun ye aap logo ko kuchh alag lagti hogi lekin yahi hakeekat hai
Sir gas loded fridge kitana ampiar leta hai and unloaded
0.6 amp lagbhag
Hama freejj ka condenser change ker liya parantu aab bhi Thanda nahi ho raha kya kera
Vaccum sahi tareeke se nahi hua hoga
sir . Ac . freez .ka cors kitne din ka hota he .aur kitni fees he
1.5 month 10000
Acha information lamba hota hi hai..
Vacuum is very important.
jo ki koi technician nahi karte AC ho freeze ho.
Na hi N2 salte n hi vacuum kare phir bhi 3500 lete gas charging karne ke chhote wale freez me R134
Freezer me oil chala jaye to kya cooling hoga
Han jada oil chala jayega to jahan jahan pe oil rahega freezer ke uss uss hisse par ice nahi jamegi
Bakee freezer pe ice jamegi
AAP ka phone no
Bhai flushing karna bahut Jaruri Hota Hai liquid oil se bhi Chauk Hote Hain
Yahi cheej pahle hamate mind me bhi tha to jabtak pata nahi tha to khoob flaxing karte then aadha ghanta ek ghanta tak lekin jab ye cheej engineer ke jariye pata chala to tabse kabhi bhi falxing nahi kiye aur firf vaccum pump se vaccum karte hain aur gas charge karte hai ek bhi fridge ac choke nahi hoti hai lekin vaccum pump se vaccum karna compressor se nahi
Bataye sir aap bolte hai ki compressor se saf mat karo to aap kyu bol rahe h com. Challu karke 20 psi bharo aur lik chek karo
Compressor ko thoda bahut chalane men koyee problem nahi hai
Ab agar ekdam nahi chalayenge to hosakta hai ki compressor ka pressor down ho iss liye cooling nahi kar raha tha to aap bina chalaye filter jod kar vaccum karke gas charge kar denge to pressure down ki wajah se cooling nahi karega aur aap presan ho jayenge
Compressor ko agar khule men 3 4 minute chalate hai to to iss se koyee problem nahi hai iss rule ko follow aap bhi kiya kariye
Cake chillar hain uska gaish sahi nhi bata rha hain
Kahe ko aap bol rahe ho sar angutha se check karoangutha se ko bhi pata hi nahin chalega Kyunki capillary se maximum 300 PSI se gas pass Hota Hai angutha hat jata hai 80 PSI mein iske liye pressure gauge Lagana jaruri hai pressure gauge Mein maximum450/500 dekhne ka
Ye ek short cut tareeka hai compressor ka pressor check karne ka
Dekhiye jab aap gas charge karenge to har baar gause laga kar compressor ka pressur check karne me problem hoti hai aur compressor ka pressure jaldi down bhi nahi hota hai
Ye tareeka bahut achcha hai jab aap kam karne lagenge to samajh me aa jayega
Pahle ham bhi isi problem men thhe but jab kaam karne lage to dab samajh me aa gaya
@@kareemtechnicalmind8172 hi
sir agar comprasr oil marta ho to gas chrge kar sakta ha
Yes ussse koyee problem nahi hogi
Correct answer
Ice cream box ke niche ice nehi jam raha hai niche ka ice cream kharab ho rahahe kyun sir
Gas ki problem hogi
Sir pipe me jada oil rehenese esa hata hai kya
Nice 👍👍
Bhai video bahut jyada lambi ho Gai hai chhoti video banaya karo
Sir apna numbar de do please
7355543798
Thuda time kam laga karo
Bhai apka number mil sakta hain kya
मोबाइल नंबर
Cake chillar me gaish 134 charj karte time
Section pressor lagbhag sahi rahta hain par standing pressor 25 psi se jada nhi jata hain kya problem h plz.. Help me bro apna number de dijiye
Suxan pressor sahi hai to sahi hai use batane do
Agat expention valve matlab capillary change kiye hoge to problem hai warna koyee baat nahi
aapka adresh ya mobile number kya hai ......
UP Azamgarh
Comment kiya kariye reply mil jayega
Hamko kaam sikhana hai ...aapke paas..