SunGoldPower 24V 3000W All-in-One Hybrid Inverter Charger: Detailed How-to & Review incl Wifi Setup

Sdílet
Vložit
  • čas přidán 3. 07. 2024
  • #sungoldpower #hybridinverter #offgrid #diysolar #emergencypower #solargenerator
    Find it here direct on SunGoldPower's website: shrsl.com/3vr3t
    Wifi Module: shrsl.com/3wwr2
    Use Discount code "ReeWray10" for an additional 10% off!!
    SunGoldPower on Amazon: amzn.to/3W3JMGf
    Victron Smartshunt: amzn.to/3CIN5LV
    Check out Power Queen Battery products here: bit.ly/3Cd58JW
    Or on Amazon here: amzn.to/3w5OGrH
    As an Amazon Associate I may earn a small commission from qualifying purchases when you use the link(s) above. This helps the channel WITHOUT any impact to the price you pay through Amazon. We appreciate your support! :)
  • Jak na to + styl

Komentáře • 215

  • @TofuInc
    @TofuInc Před rokem +9

    Same unit is sold under ECO-WORTHY, PowerMr, Chins, and a few others for $125 less. I have the ECO-WORTHY branded one which includes the WiFi adapter. These are amazing value for what they can do.

  • @bobbymcgee901
    @bobbymcgee901 Před rokem +1

    Awesome! I’m doing this setup in my tiny home build. Good info

  • @cybeer67
    @cybeer67 Před 9 měsíci

    Thank you SO MUCH for sharing ! Detailed !
    Im most definetly going with this setup.
    Thank you.

  • @Lev_Flo
    @Lev_Flo Před 9 měsíci +1

    This video is superb!! FYI: Aside from the location of the screen, this "24V 3000W All-in-One Hybrid Inverter Charger" is generic and has the same hardware/setup as many other rebranded ones. Thank you for a very detailed and helpful video.

  • @jathumb1705
    @jathumb1705 Před rokem +4

    This is nearly my exact setup. It works well so far, but I've only had it running for a few days. I want the wifi module but it's hard to justify $100 for something unnecessary. I'm glad to see a video for the exact model I have, because I wasn't able to find any previously.

    • @bobbymcgee901
      @bobbymcgee901 Před rokem +2

      There’s almost nothing out there for this product man. It’s tough. Just new technology. Give it some time and people will start to realize these are the way to go

  • @ozb2006
    @ozb2006 Před rokem

    hi so my wife and i want to go camping and we were looking for some kind of portable power, and everything with a good amount of battery was super expensive, and i ended up buying this unit + 16 lfp 50 amp cells, cells were 570 bucks inverter was 650 12 to 24 volt converter so we can charge in the car and 3 100w portable solar panels for 300 dollars.
    for a grand total of 1500 bucks and we have access to 2.56kwh of charge time, with a 3kw inverter and solar panels
    when everything else around the 1800wh's was around 1800 dollars to 2500 dollars without the panels
    and this video is what helped me make the decision to buy the parts

  • @joeglennaz
    @joeglennaz Před rokem +2

    Great video, especially doing the laptop. Example that really makes it easy for a lot of us to understand.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +2

      Thanks Joe! I do try to strike a balance of details since I have viewers who are very experienced, and viewers who are completely new to this stuff...it's a challenge and I'm not always successful. :P

    • @joeglennaz
      @joeglennaz Před rokem

      @@ReeWrayOutdoors We'll you're doing a great job! I have a Tesla Solar system but NO batteries. I"m wanting to add batteries and a generator plug exactly what you show in this video down to the two 120 plugs nearby. Right now I'm looking for a company or electrician that is familiar with this stuff to do the installation for me. I am not handy at all so I need help in this area BUT your videos are helping me to decide what type of equipment to consider and I can use your videos to show the contractor what I'm looking to do. They say a picture is worth a 1,000 words, well then a video must be worth a million or much more! Thanks again!

  • @dandahmann128
    @dandahmann128 Před 10 měsíci

    Your a smart man, thank you.

  • @dustymccraw7715
    @dustymccraw7715 Před 6 měsíci

    great video. a clearly communicated and well thought out presentation. Utube needs more like this:)

  • @PaulHenreid
    @PaulHenreid Před rokem +1

    great video and product review - thank you

  • @johnmal5975
    @johnmal5975 Před rokem +13

    I think this is the way I am going to go with this solar emergency back up. You get so much more for your money with this compared to ecoflow-bluetti, pecron etc.. It's not plug n play but it is pretty darn close. Plus I like the idea of flexibility with battery's etc.. your not stuck to an overpriced ecosystem.

  • @sun-sea-solar
    @sun-sea-solar Před 3 měsíci

    I can configure my inverter settings from the app. It's awesome

  • @gdpower456
    @gdpower456 Před rokem

    very thorough. thank you

  • @BorderlessBelik
    @BorderlessBelik Před rokem

    Super helpful video - greatful you put this together for all us who've purchased the Sungold inverter/charger - and thanks for the Wifi Module walkthrough - def gonna use it
    Suggestion for you - add the link to the Wifi Module to the description :)
    much luv!

  • @jr10
    @jr10 Před 10 měsíci

    Awesome review! I was just getting ready to pull the trigger on the Sungold after watching this, but in looking at the minimum voltage required for solar panels it shows a minimum of 120 V. I only have 40 V of the present. I was pretty disappointed. Maybe someday.Thanks again for a great video.

  • @DeclanWalshEsecurity
    @DeclanWalshEsecurity Před rokem +1

    Very informative and a great job 👍

  • @deanstackhouse8775
    @deanstackhouse8775 Před rokem

    re : Jump 1000 & Jackery 1000 comparison video/there was no comment option available on my phone so I'm here as a new subscriber.
    You can use a wine cork, the plastic one's preferred to be able to clean easily, for plugging open DC female ports. The size is perfect and you can fasten a cord to both easily to link them together.
    Thanks for the content. I'm off grid since the 1970's and need a solar generator and since lightning struck my panels (long before protectors were available) I'm gonna be viewing quite a bit and appreciating your channel.
    Thank you

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      A cork!! Excellent idea!! Thanks for sharing that, and thanks for the kind words! Sincerely appreciated, my friend!

  • @goodoz9942
    @goodoz9942 Před 8 měsíci +3

    Not trying to be a wet blanket...but it looks like you're coming right off the AC output of the inverter with white Romex (14GA/15A) and feeding a 5-15R receptacle. Then, you're using a changer from that 15A plug to feed your 50A transfer switch (you mentioned 6 circuits?). This Sungoldpower unit can output 3000W (25A). So, if you have more than one 15A circuit lit up on that service box at one time, you're under-cabled and need a 15A breaker in front of the service panel. I'd propose running a 10GA Romex (orange) directly from the AC output to the service panel. Then, if you still want to have a 15A outlet there on the wall, feed it with a 15A breaker from the service panel. Just my 25 cents.

  • @ifrancus9623
    @ifrancus9623 Před rokem

    Nice explanations of set up. I have the same system except it is labeled CHINS, for which I could not find a video.

  • @GmanfromTexas
    @GmanfromTexas Před 18 dny

    Very gooodd vide. It's helping me install mmy new PowMr unit.

  • @talusranch990
    @talusranch990 Před 5 měsíci

    Excellent video

  • @Ne0Z33D
    @Ne0Z33D Před rokem +1

    Thanks for the video! Got mine setup on Sunday. Any chance you can share your settings?

  • @steveschaefer5835
    @steveschaefer5835 Před rokem +2

    Thank you for posting these. I learned a lot from your videos. I guess if you had some components that ran off DC you could just make a bus bar and draw the power straight from the batteries so you wouldn’t have to draw power to though inverter all the time

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +3

      Sure! As long as you're matching 24V compatible devices with a 24V battery configuration (or use an appropriate step-down converter....or build a 12V battery configuration instead and pair with a 12V inverter, etc)

    • @steveschaefer5835
      @steveschaefer5835 Před rokem +1

      ​@@ReeWrayOutdoors I like the idea of running a 24-v system. There seems to be a lot of step-down converters that are cheap and use less power than the AC inverter

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +4

      @@steveschaefer5835 Yep, I'm right there with you on that!

  • @johnaugsburger6192
    @johnaugsburger6192 Před 4 měsíci

    Thanks

  • @SuperSushidog
    @SuperSushidog Před 7 měsíci

    Thanks for the review. I'll be getting the 5kw 48v model before the end of the month, as they are on sale for $721 till Nov 30. I just received 8, 550w SunGold Power solar panels to rack on the roof of my motorhome and will use this to charge a 310ah 48v LiFePo-4 battery and provide inverted 110v a/c power for my MH, including my rooftop AC and a mini-split heat pump. I like the fact that this model can operate without a battery if needed, as most all-in-one units must have a battery to function.

    • @jerrytalley802
      @jerrytalley802 Před 3 dny

      So you mean this would run off the solar without batteries? Thanks

    • @jerrytalley802
      @jerrytalley802 Před 3 dny

      Was your DC breaker made by Sungold as well?

    • @SuperSushidog
      @SuperSushidog Před 2 dny

      @@jerrytalley802 It can, but only when the sun is shining.

  • @props-model-shop
    @props-model-shop Před rokem +1

    Congrats to you! You are the first person to recommend using a bogas home address. 😇😇😇

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      haha yeah, not sure why that field was marked as 'required'.

  • @lameaxe
    @lameaxe Před 10 měsíci +2

    Could you give us an update? Still working to spec? Happy with it? Thanks.

  • @ovidiotunon8476
    @ovidiotunon8476 Před měsícem

    Excelente video pero cuantos paneles solares serian sufisiente y de cuantos vatios

  • @denniszancan9073
    @denniszancan9073 Před 10 měsíci

    Hi love your videos. I just bought the sun gold 3000w all in one. My question is in setting up the battery parameters I don’t see one for Lp04 lithium types. What should the settings be . Thanks in advance.

  • @arnecarlsson9740
    @arnecarlsson9740 Před rokem +2

    Great instructional video! 👏👏👏 If you can let me know where you got that beefy DC breaker.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      Thanks Arne! I bought that 160A/500V DC breaker on Amazon. Not sure where you're located, but here's the US link: amzn.to/3XPKTL4 I can't say if this breaker is the BEST choice, but it'll certainly get the job done...and it's not an inexpensive piece of hardware.

    • @bobbymcgee901
      @bobbymcgee901 Před rokem

      Amazon $100

  • @m.o.f8720
    @m.o.f8720 Před rokem +5

    Thank you for featuring this unit. Looks very promising in function and price. Would have appreciated details on the 160a disconnect. Not specifically called out in the manual just a spec. Brand name doesn't Google at least not for me. Please update your description to include a link. Thanks

  • @klawrence7466
    @klawrence7466 Před rokem

    I love this! Do you happen to know the exact model of the power transfer switch you have? I would like to provide it to the electrician to explain what I am trying to do.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      amzn.to/3DxmjqD. This is the one I have. My electrician did have to do something (I vaguely recall) to set it up for 120v instead of 240v, but it wasn't a big deal. I think, all in, it cost about $1000... parts and labor.

  • @W0BNC
    @W0BNC Před 9 měsíci +1

    Great video! One question though... how did you decide to orient the 160A breaker the way you did? I bought the same one, and it is marked LINE at the top, and LOAD on the bottom. So in my head, I'm thinking that LINE should go to the battery and LOAD to the inverter. Your thoughts? Have you had any issues with it the way you have it oriented?

  • @jstagzsr
    @jstagzsr Před 24 dny

    i have the "48v 5000w" all in one version.. although it can do up to 60v and output 63A continuous so its actually a 7500w unit. ive been having issues with what i assume is programmning. i live in the woods on a 5 acre property and i built this probably $10k system to be fully off grid but i am relying on a 300 foot 10 guage extension cord i built to plug in to a garage in order to charge my batteries because the panels arent charging like theyre supposed to. id love to have a convo withs omeone familiar with these units so i can go over settings and see where the issue is.

  • @miguelv431
    @miguelv431 Před rokem +1

    Can you share the link for the transfer switch ?

  • @PreparelikeJoseph
    @PreparelikeJoseph Před 9 měsíci

    I purchased the same sun gold. I’m trying to do 2s2p with 4 250 watt panels. Open circuit voltage 37.6 each. I know I need some sort of branch connectors and 20 ft extension cable but I can’t figure out the gauge wire I need.

  • @NoKingButChrist1689
    @NoKingButChrist1689 Před 11 měsíci

    Would you happen to have the parameters for your set up? Or could you do a video showing how you set up your controller

  • @NadeemAhmed-nv2br
    @NadeemAhmed-nv2br Před rokem

    Is it possible for you to find out whether the ground neutral bond is established within the inverter or if it needs to be established separately?

  • @donfrank4429
    @donfrank4429 Před 5 měsíci +1

    going to have 6 300 w panel, going to build a ground stand then run in the house hooked into this with battery backup and grid power Ill plug into a 110 volt house plug, any suggests

  • @jrr3787
    @jrr3787 Před měsícem

    Do you not need fusing between your solar array and the inv erter and between the inverter and the ac input/outputs?

  • @Anthonygratz
    @Anthonygratz Před rokem +1

    How many solor panels and wats for panels

  • @ozb2006
    @ozb2006 Před 8 měsíci

    hi i finally got around to putting it all together, but i am having trouble with configuring the unite to charge my lfp's correctly
    can you make a more in depth video about just the menu i am having a very hard time understanding there instructions manual
    is not written very well .

  • @hsidder
    @hsidder Před 10 měsíci

    Do you happen to have a link to the breaker? Love this setup. Thanks for sharing.

  • @dickdyson3100
    @dickdyson3100 Před 4 měsíci

    Gotta update this video man. They have a upgraded model of this one 80A mppt with 120-450 open circuit volts

  • @fredrodriguez177
    @fredrodriguez177 Před 11 měsíci

    Can you add more 24v batteries to boost the run time?

  • @robertrice4441
    @robertrice4441 Před rokem +1

    Does it have auto restart if on battery and the voltage drops too low, and then batteries are recharged from solar?

  • @W0BNC
    @W0BNC Před 8 měsíci

    I cannot get the green icon on the datalogger screen to go green. The one you mentioned that had the little antenna pointing to the left. Any ideas?

  • @jackehli621
    @jackehli621 Před 5 měsíci

    Souldn't there be a breaker on the AC outlet? The instructions says to put one.

  • @gregsdroneservices
    @gregsdroneservices Před rokem

    Thanks for answering my questions , I really appreciate it. I have just ordered everything in this setup. I am taking my shop off grid and going solar only , my only concern is starting up and using my air compressor which is 120v, 60 Hz, 14.5 A , 2 HP, 20 gal . Do you think using your setup as pictured will work for me? Thanks

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      Hard to say for sure on that compressor. Might be cutting it close. I'd recommend asking the Mfg of the compressor what the continuous and peak power draw on your compressor. As long as it doesn't exceed 3000W/6000W, you should be ok.

  • @bobbymcgee901
    @bobbymcgee901 Před rokem

    I plan on pairing this with 2 100ah lithium’s 24v. And 800w solar. Will that be sufficient

  • @jrr3787
    @jrr3787 Před měsícem

    How did you mount that breaker? Mine came with two bolts. There is no way to attach them to a 3/4 sheet of plywood.

  • @thssportingcenter1
    @thssportingcenter1 Před rokem

    Okay newbie dork question buttttt I have two 12V 200Ah Lithium LiFePO4 Battery wired in series for 24V and the charger I currently own is a 7 stage impulse charger 12V 20Ah . So it's under powered by what I have read. I do have a Powermax 110V A/C inverter to 24V D/C 50Ah output. I don't think that will work like I use to use for AGM batteries

  • @mgentile7
    @mgentile7 Před 2 měsíci

    what if you used 4 12v batteries? would you need different components?

  • @NoKingButChrist1689
    @NoKingButChrist1689 Před 11 měsíci

    My only problem with the set up so far is that they are sending me the kit in sections and about 2 weeks apart. Got the batteries and inverter first. Two weeks later the panels came in. Now I'm waiting on the extension cables and brackets. So if you buy the kit and you think it's all coming in one load it won't

  • @donfrank4429
    @donfrank4429 Před 5 měsíci

    How many panels i need 3 or 4, 12 or 24 volt panel, and other information on the panels to know to buy the correct ones , ill hook in series correct

  • @mrhalfstep
    @mrhalfstep Před rokem

    I just acquired a different brand of what I believe to be the same all-in-one as you have. My unit's specs says, in the battery wiring section, that the breaker should be 160 amps, just as yours is, but that the battery should have a 140 amp discharge current. I noticed that you have series connected two 12 volt batteries that i believe are 100 amp max discharge current as limited by their BMS. Am I correct in understanding that you still just have 100 amps available from the batteries paired that way? I was assuming that the 140 amps was required to get the full 3000 watts of power from the unit and, by my calculations it would, down to about 21.5 volts. I realize that this is a demonstration video, so were you just keeping it simple for the video rather than trying to get maximum power from the unit? I'm asking for your help on this because I'm looking for all the power that I can get and my next move was going to be buying a pretty expensive 24 volt battery with a 150 amp BMS. I have 2 12volt 100 amp batteries that I could wire like yours if it would give me the 140 amps that I need. Just need to know if I'm thinking right before I buy the larger battery. Help!

  • @OH-dv8gg
    @OH-dv8gg Před rokem

    Does the inverter get hot whilst not in use and connected to grid power ?

  • @angelagarcia6844
    @angelagarcia6844 Před 16 dny +1

    Hola! Tengo una unidad en mi rancho y presenta muchos problemas en su funcionamiento, nadie nos ayuda a configurarlo, puedes ayudarme? Por favor gracias

  • @christiaanollewagen1079

    I bought the SRNE hybrid solar inverter. I am going to in stall it with change over switch ,and 2 40amp 2p breakers for feed to inv and load from inv and a earth leakage breaker. And connect that to my house dB board .is there any info or wiring diagram you can help me with

  • @gonzalez7805
    @gonzalez7805 Před rokem

    👍

  • @larrynone6354
    @larrynone6354 Před 9 měsíci

    Do the panels have to be wired in parallel.

  • @dangeroustoman
    @dangeroustoman Před rokem +14

    The problem I see with these all in one units is if something happens you can't just replace the part, you have to replace the whole unit.

    • @aristidesroman435
      @aristidesroman435 Před rokem +5

      All in one is for my the last way to go..
      I learn the lesson .. and when you call for warranty they take forever to respond and a long..... prosses to give you warranty cover

    • @kevinholland4156
      @kevinholland4156 Před rokem +4

      That's the problem I have with the bigger solar generators. If something pukes; you have to send the whole unit back to Wherever. I honestly prefer the component builds over an all-in-one unit.

    • @randybobandy9828
      @randybobandy9828 Před rokem +2

      Thats not really an issue.

    • @randybobandy9828
      @randybobandy9828 Před rokem

      @The Solar Junkie lol no

    • @Athandle098
      @Athandle098 Před 8 měsíci +1

      I've run a modular approach to my solar system and what I've found is that charge controllers don't break, also I run 2 make sky-blue charge controllers in parallel with this charge controller so each array is separate from the next. My grid charger also is exceptionally reliable and that also can be in parallel. What I've found is that inverters most frequently fail and it's the capacitors in them that fail. I was of the same mindset for a long time but this system is really nice

  • @PreparelikeJoseph
    @PreparelikeJoseph Před 9 měsíci

    Each of my 250watt panels is 37.6v. I was going to 2s2p the panels. Can this sun gold charge controller handle that?

  • @thienthan324
    @thienthan324 Před 7 měsíci

    I have been watching CZcams videos. Everyone always say not to back feed into the grid. I see people literal have to turn off the panel breaker first. Will this Sungold back feed into the grid? I am still new and very confuse about this back feed process.

  • @danstenis660
    @danstenis660 Před 8 měsíci

    How does this sungoldpower 3000W all in one compared to other brands?

  • @brianwedge5497
    @brianwedge5497 Před 7 měsíci

    Any chance you could send me the settings you are using for lithium batteries. I have two new 280 amp hour coming and want to stop using the user settings and start using the lithium settings but don't know what settings need changed.

  • @jerryC2023
    @jerryC2023 Před rokem

    Question regarding the Reliance Power Transfer Switch. I have one wired in which came with my house. I have a gas generator with a reliance power cord 30am which plugs into the box. Do you have a video on your setup or diagram and or link to the power cord adapter with the green ends? Best method of connecting to a transfer switch?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      Yeah, I bought this RV30 to 110V 3-prong adapter so I'd have the option to supply power with any of my power stations and not just the couple I have with RV30 outputs. Here's the one I bought: amzn.to/3WAEVwi

  • @jerrytalley802
    @jerrytalley802 Před 3 dny

    This was a really nice review. I want to build a portable power station and this looks perfect for that. QUESTION; so if you put 2 x 100 amp 12 volt batteries in series you get 24 volts. If I want twice the amp hours, will I need to upgrade in pairs of 2 x 12 volt batteries each time? I wanted to use a 12 volt inverter, but can’t find one anything nearly this nice for the price, it’s perfect because the solar and charger are built in. It looks quality, not like the junk on the net?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před 3 dny

      It's definitely in the 'budget' category but I think quite suitable for building a capable power station rig. You COULD use a 100Ah 24v battery and then simply connect another in parallel to double your capacity...or just buy a 200Ah 24V battery. But if you do start with 2 12V 100Ah batteries, additional 12V batteries would have to be connected in pairs to maintain that 24V system voltage

    • @jerrytalley802
      @jerrytalley802 Před 21 hodinou

      Thanks, I figured the battery setup would have to be pairs of 12 volt in parallel, thanks

  • @kevinholland4156
    @kevinholland4156 Před rokem +1

    I have the same Reliance transfer switch. Why are you stepping down the power cord to the switch using that 15 or 20-amp plug? I think you should be consistent with the wire gauge and wire in a 30-amp box and not a 15 or 20-amp receptacle. When I run my two Honda 2000-watt inverter generators together I plug a 30 amp cord into them and into my Reliance transfer switch/breaker that is wired into my panel as yours is.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      Fair point! I only did it that way because it was what I had handy and since I don't typically run more than just a couple of circuits off my transfer switch (and those circuits are not fully utilized), so it seemed like just doing the 15A outlet was the easiest and more general purpose option. I probably should've talked about that a bit in the video.

  • @c3r0
    @c3r0 Před rokem

    Great video, wish you had an exact list of all the items you used to set this up. Viewing the video a few times, I've been able to figure out all the items you used but stuck on the one for the solar panels. What type of breaker are you using? that runs via the mc4's? Also what wattage are you running into that breaker from your solar panels? Thanks! Vid was excellent.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +2

      The breaker I'm using is this one: amzn.to/3mOSEn6 It's a 1000V/25A breaker dual pole. Perfect for my 800W series setup, but also just right for 2S2P configuration as well. If you have a bigger panel array than that though, you'd obviously want something with a higher current rating. When I've got my 4 200W panels in series, I'm getting about 84V through the breaker...and half that when using 2S2P (I do have to reconfig as needed when I'm testing input on various systems).

    • @c3r0
      @c3r0 Před rokem +1

      @@ReeWrayOutdoors I'm also doing 4 200W panels in series, to get 800W. Did you get 12v panels or 24v panels to use on this 24V system? I will be using 2 12V 100ah batteries to create 24V battery for the all in one charger/inverter system. Do you have a different video on how to setup the 1000V/25A breaker dual pole? It's my first time trying to do that. I looked on the site you mention (Shop Solar Kits) for the all in one setups, but they lack any info on these specific details. I also read the manual but a bit confusing still. Thanks again. I only stopped by here because SunGoldPower has you on their landing page on their website. Congrats! You should add a shopping list to your description so others don't have to bother you, like I am 🙂

    • @c3r0
      @c3r0 Před rokem

      @@ReeWrayOutdoors Just to clarify, the manual does state "Maximum PV input current: 40A" and "Recommended air switch or circuit breaker type: 2P-63A" and you are using the 1000V/25A version. So would there be any trouble if you used the 1000V/63A version of this breaker? Wondering why you used the manual specs for "Recommended battery input wire diameter and switch selection" but not for "Refer to the table below for PV input wire diameter and switch" - Thanks again.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      @@c3r0 Mostly just because I'd already had my 800W array installed with the 25A breaker before I got the 3000W inverter. So it's fine for me as it is, but at some point, I'll definitely want to put more solar up and I'll need to upgrade that breaker when that time comes.

    • @c3r0
      @c3r0 Před rokem

      @@ReeWrayOutdoors And you using 8AWG on 25A version? or 10AWG? on those MC4's

  • @vlatter9537
    @vlatter9537 Před 2 měsíci

    Why do we need to buy an 160 amp breaker?

  • @dashboy007
    @dashboy007 Před rokem +2

    Where did you get the big beefy 160-amp breaker from??

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      Amazon. :P I'm definitely trying to promote that particular breaker, but it's working fine for me. The instructions were all in Chinese :-/ but hey...it's a breaker so...it's not like I needed any installation instructions. ;) But here's the (shameless affiliate) link if you want to check it out: amzn.to/3HWFUTq

  • @starrwulfe
    @starrwulfe Před rokem

    I wonder if there's a way to get this installed into an RV; SunGold makes an inverter/charger that I guess specifically is for RV applications, but it's more money than this...

  • @CatMan654
    @CatMan654 Před rokem

    Perhaps I’m confused about the AC out grounding wiring. I assume the Pro Tran transfer switch is grounded to the residential service panel so a floating neutral generator can be plugged into the transfer switch creating only one source for grounding. If this is correct, then the AC out ground wire should not be connected to the inverter? On some inverters, this double grounding can cause voltage on the neutral and ground wire including tripping GFI circuits. Any thoughts/education on this issue?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      Actually, I don't think you're confused at all. I think you're 💯 correct about that! Thanks for pointing that out!

    • @CatMan654
      @CatMan654 Před rokem

      Thanks for the quick reply; it is most appreciated. (I was waiting to hear back from Sun Gold Power on the same question.) Enjoy your channel and the video on the: “DIY: Let's Build an 800W Ground Solar Array for Emergency Backup Power.” If you have the time, I have a few more questions to complete my design build project like yours.
      1. The manual recommends the AC out wire as 8 AWG. For a 3000W inverter, I would assume 10 AWG (30 amp) would be sufficient since my Pro Tran ten circuit switch is rated for 30 amps and the breakers in the switch would trip before it got close to the amps for 8 AWG solid copper residential wire. Thoughts?
      2. Also, the AC in wire is recommended for 8 AWG. I would assume a 10 or 12 AWG wire standard three prong plug would be OK to plug into a non-switched/dedicated 20 amp grid outlet would be sufficient (to keep the battery bank “top-offed” under a UPS - laptop scenario as you demonstrated in your video)? I plan on keeping 3 critical circuits on the Pro Tran that power Fiber Input, Router, NVR security cameras, and Plex server running during intermittent power outages greater than my per line APC UPS (i.e., 30 minutes to an hour). Thoughts?
      3. Is 2 AWG wire sufficient for all the connections in a 2s2p configuration using four 12.8V 100Ah LiFePO4 Batteries? Any thoughts on using an Ampper High Current 1-2-Both-Off Battery Switch to isolate the 24 V battery banks before the monster DC breaker? Just in case one of the batteries goes flaky.
      4. Perhaps I missed it, but what gage was the PV wire used for the 800W Ground Solar Array?

  • @steveschaefer5835
    @steveschaefer5835 Před rokem +1

    Now that you’ve messed with this for a while, have you had any problems with it? I posted a question on a solar Facebook page, and one of the responses was that his failed within a couple of weeks, and Sun Gold Power jerked him around on his warranty. He said that the only way they would communicate with him was through email, which added to his frustration

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      So far no issues at all. I think it's common with most electronics (certainly computer systems) that if you're going to have an issue, it's most likely to arise in the first few weeks of operation. Past that, you're usually in the clear for the duration. But yeah, no problems - but that also means I haven't had to call into their customer support either, so I don't have any encounters to share either way on that.

    • @steveschaefer5835
      @steveschaefer5835 Před rokem

      Thanks

  • @justin6125
    @justin6125 Před 11 měsíci

    Quick question I was looking at the spec sheet it says voltage range for solar 120-400vdc.
    My panels are 37.40vdc 250watts 16x pannels should i put my panels in series to achieve the 120v or will 37.40v charge the batteries without them being in series?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před 11 měsíci

      Maybe you're looking at a slightly different model, but the one in this video is a 24V / 3000W AIO Hybrid. My manual says the Solar (PV) Operating Voltage Range is 30-100Vdc. Also, I'm not sure I understand your setup. You have 16 of those 37V 250W panels? And if the actual operating voltage range of the model you're looking at is 120-400V, you will need at LEAST 120V input for the charge controller to begin sending power to the batteries.

  • @d-cshepherd7282
    @d-cshepherd7282 Před 7 měsíci

    can the battery be 2 x 12volts in series?

  • @vlatter9537
    @vlatter9537 Před 2 měsíci

    And what is "error code 21"? Can anyone help

  • @dryroasted99
    @dryroasted99 Před měsícem

    I have a single 300-watt 10BB mono solar panel and 12V 100Ah, would it be sufficient for this inverter?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před měsícem

      300W of solar is pretty low...assuming the capacity of the battery bank it's connected to is more than about 1200Wh. That said, the minimum output voltage of the panel would need to be greater than 30V or you'll get no charge input, since the PV input voltage range is 30-100V.

  • @gregsdroneservices
    @gregsdroneservices Před rokem

    being it is on a 15A breaker would the max watt it can draw be around 1,800 ? or no ? thanks

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      Yeah, if you're running it on a 15A circuit now, you should be completely fine.

  • @gregsdroneservices
    @gregsdroneservices Před rokem +1

    What solar panels did you use with this setup ? thanks

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      These are the panels I'm using: amzn.to/3SwCieL You can see how I built me small 800W array here if you're interested: czcams.com/video/2vstcsJR54k/video.html

  • @gchacon316
    @gchacon316 Před 11 měsíci

    @ReeWrayOutdoors, I've been on CZcams for a while, but I never learned how to message or contact someone on a channel. How can I reach you to ask some questions that would be long and drawn out on this platform?

  • @SlimSh8E
    @SlimSh8E Před rokem

    Do you have a link for the breaker? I looked online and could not find that particular one. Thanks.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      This is the one that I bought on Amazon (shown in the video): amzn.to/3XoZ0aj It's a beast!

    • @SlimSh8E
      @SlimSh8E Před rokem

      @@ReeWrayOutdoors Okay, thanks for the info!

  • @gregsdroneservices
    @gregsdroneservices Před rokem +1

    If you can I need some advice , I have the same same setup as you have here , I only want solar charging no grid, system is showing it is charging from solar to battery and to my shop but, the volts keep dropping and in time will completely discharge my batteries. I have 4 200 watt panels in series which gives me 80-82v coming in , I also tried the series and parallel combo which gave me 42v and 22amps, but neither way would keep my batteries from going all the way to dead. Acts like system is not even charging batteries at all even though it shows it is. I have contacted Sungoldpower but no help at all. Thanks

    • @clgraham82
      @clgraham82 Před rokem

      Being 2mths ago since you asked this, you probably already figured it out...but, I just ordered this unit and manual says...PV operating voltage range 120-450Vdc...so your 80-82v needs to be bumped up to 120v min...more panels.

  • @paulgallant8115
    @paulgallant8115 Před rokem

    How long does the discount code last? I plan to buy one of these in the next 30-60 days.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      They didn't mention an expiration date, but usually it's around 30 days, but it does vary...

  • @gregsdroneservices
    @gregsdroneservices Před rokem

    I’m trying to install the Wi-Fi on my inverter, it’s telling me when trying to finish setup that the datalogger already exists and won’t continue any idea ?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      I seem to recall that I ran into that something similar when I was doing the 'redo' of the setup for the video. I think I ended up deleting the wifi module from the app (might've been some option to unbind or something like that? Can't recall for certain) and starting from scratch. The biggest confusion for me was just being patient enough to wait after the initial data-logger setup to let the system do whatever it needs to do (for about an hour maybe) and let the data-logger eventually show-up in the app. Definitely not very intuitive setup, which is why I tried to show it in the video. :P

  • @samfish6938
    @samfish6938 Před 3 měsíci

    try and go 48 volts less amps smaller cables

  • @FishtankandDIY
    @FishtankandDIY Před rokem

    Hi , how noisy is the inverter? It’s loud? The fan is running all the time?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +2

      DOH!!! I actually had a clip showing that and somehow failed to mention it and so it didn't get inserted. :-/ The fan does not typically kick on unless it's charging/discharging somewhere around 800W+. And the fans are variable speed and mostly in the 65dB range. But when you get over the 1000W draw, the fans will kick all the way on and it IS fairly loud at that point...about 85dB I think. So, definitely a consideration if you're in a small space and don't have an easy way to confine it to a space that can provide some sound isolation.

  • @gregsdroneservices
    @gregsdroneservices Před rokem +1

    What size battery wire are you using to connect batteries and also what size from battery to Inverter ? thanks

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      This inverter is 3000W / 24V so the max current draw is 125A. So for wires to the inverter, 2 awg should be fine. And on the batteries, the same 2 awg gauge wire would be fine in this setup since I've connected 2 100A batteries in series. But for the same basic setup where the Inverter is 12V and the batteries are wired in parallel - you'd have double the current potential and so you'd want to go with 2/0 awg. And this is why it's advantageous to go with a 24V/36V/48V configurations for higher loads (>3000W) since cable gauge starts getting inconveniently (and expensively) large. Note that I'm also assuming here that the cable runs are all

    • @vroor32
      @vroor32 Před rokem

      ​@@ReeWrayOutdoorswhat size are those lugs (eye-size) attached on the inverter +/- connection?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      @@vroor32 on the battery connectors, it uses (per the manual) ring terminals with a 5mm inside diameter

    • @vroor32
      @vroor32 Před rokem

      @@ReeWrayOutdoors honest to God, I looked at the lugs that came with it, there's no writings... I was so confused 😕 I'm up sizing the cabe to 2AWG and needed larger lugs with same eyehole

  • @NoKingButChrist1689
    @NoKingButChrist1689 Před 11 měsíci

    I hooked up the panels to the inverted but its not seeing the panels. What could be the problem

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před 11 měsíci +1

      couple of quick thoughts... Check the open circuit voltage on your incoming solar leads and make sure you're getting the minimum required 30V or higher for the SGP charge controller to begin charging. Definitely ensure your polarity is not reversed. Then also check to ensure that parameter 06 (Charger source priority) is not set to CUB - since it will only charge PV if grid is disconnect in that mode.

    • @supercomp65
      @supercomp65 Před 2 měsíci

      I'm having the same issue. I'm getting 80-90v off the pv panels and no matter what settings I use, it will not charge off the panels.

    • @NoKingButChrist1689
      @NoKingButChrist1689 Před 2 měsíci

      @supercomp65 So I had to run mu panels in series. I think that's the case. I had to call them and I think originally we had them in parallel

  • @barryc52022
    @barryc52022 Před rokem

    Are they stackable? Can you run 2 together and get 240 volts?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      Not an option with this unit. You'll typically need to spend a few more bucks for that option.

  • @daverohn383
    @daverohn383 Před rokem

    I was going to click your link and buy this, but Amazon takes me to the 5K, 48 volt inverter instead.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      Thanks for the heads-up. Looks like they're not selling that particular model on Amazon right now and they did a switch-a-roo on the listing. Here's the closest model they're selling on Amazon right now (upgraded charger, and solar input capacity, but 2400W instead of 3000W): amzn.to/3NyyusY The 3K/24V is still available on their website though, if you'd prefer that: bit.ly/3NBAqRl

  • @lennmason1142
    @lennmason1142 Před 3 měsíci

    this system is low on amp hours for a 3000 w inverter

  • @helpmeretiresoon5972
    @helpmeretiresoon5972 Před rokem

    What if your using it in a van instead of at he? Do you even need that wifi module?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      I wouldn't bother with the wifi module in a mobile situation. No advantage other than being able to look at trends.

  • @bakina89
    @bakina89 Před rokem

    How much solar panel wattage can the 5000 watt inverter handle?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      The 48V 5000W Hybrid Inverter can take up to 5000W/500V solar input.

    • @erikiversen2039
      @erikiversen2039 Před rokem

      @@ReeWrayOutdoors I think that the question should’ve been how many panels can we put on the roof with that amount?

  • @brianwedge5497
    @brianwedge5497 Před rokem +1

    Have you done a load test with this inverter? I have the same one and it faults out at around 900 watts with low voltage error. Any suggestions on what's wrong?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      Hmmm I know I've had more than 1000W on it without an issue. But I'll retest as soon as I get a couple of other batteries charged up (I'm prepping my other pair for a 2S2P setup here shortly). Have you reached out to SGP tech support?

    • @brianwedge5497
      @brianwedge5497 Před rokem

      They are blaming ampree time and vs versa

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      @@brianwedge5497 does it fault immediately at around 900W, or after some period of time? I did just confirm that mine will run 2900W without faulting. And I don't have 2 of the Ampere time batteries, but I connected 1 in series to a Timeusb battery, and I'm not seeing any issues yet.

    • @brianwedge5497
      @brianwedge5497 Před rokem

      Do you have any grounding on the inverter or the batteries? I ordered a new breaker for the positive side. I hear a click after around thirty seconds and it faults out and tries again until it quits trying.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      @@brianwedge5497 No grounding, unless I have the AC input plugged-in (and I didn't during the testing).

  • @gregsdroneservices
    @gregsdroneservices Před rokem

    I have added same setup as you are showing but, system won't charge batteries back from Solar panels, I have 41V at panels and it shows 41V coming in on inverter but don't show charging on LED screen only shows icon of a solar panel, I have sent videos and pics to customer service and they keep giving me the run around, and they have no phone number only contact through email and there in a different time zone which means It takes a day for my email to get back to me from them and me to them, so for me this is not a good company to do business with. They won't fix my problem and so far have not even offered a refund.

  • @jorgeortiz3565
    @jorgeortiz3565 Před rokem

    What system do you recomend for someone that is not that bright when it comes to electronics like me? Age and lock of knowledge is always an obstacle in the new world of sience.😢

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      Depends on what you want it to do, really. :) You can do alot with a Portable Power Station, but there are trade-offs for that convenience (generally higher cost and less expandability).

    • @jorgeortiz3565
      @jorgeortiz3565 Před rokem

      @@ReeWrayOutdoors im building a patio in my back jard and i d like to set it up with a few solar panels instead of running electricsl from the panel.

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      @@jorgeortiz3565 what are you wanting to power and for how long?

  • @gregsdroneservices
    @gregsdroneservices Před rokem

    Can you put these batteries in series and parallel ?

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem

      I assume you're talking about the 100Ah PowerQueen batteries I showed? Yes - these can be combined up to 16 batteries in a 4S4P configuration.

    • @gregsdroneservices
      @gregsdroneservices Před rokem

      @@ReeWrayOutdoors
      Is there anyway you may can do a video on how this is done ? Thanks

    • @ReeWrayOutdoors
      @ReeWrayOutdoors  Před rokem +1

      @@gregsdroneservices I I have a video that shows series and parallel (separately) but doesn't show Series/parallel. I'm actually planning to do one on 2S2P configuration as soon as I can find the time - probably some time in the next few weeks. :) Here's the other video, if you're interested: czcams.com/video/EDLxolJ0QxI/video.html

  • @jallenneufeldt3611
    @jallenneufeldt3611 Před 9 měsíci

    695.00