Episode 4F : Rebar installation and Concrete Pouring of Footing Tie Beam

Sdílet
Vložit
  • čas přidán 20. 08. 2024

Komentáře • 211

  • @barksofw
    @barksofw Před 3 lety +2

    Salamat sa tips idol gumagawa rin poh ako ng aking small house.

  • @arjundano7521
    @arjundano7521 Před 3 lety +1

    Ang galing mo idol...dami ko natutunan sa vlog mo..

    • @acetvph7587
      @acetvph7587  Před 3 lety +1

      salamat nmn ka lodi kahit effortless ang videos ko.. Trial p lang kung makapasa kay youtube.. at ngaung nakapasa na.. Pde n natin karerin pa ng mas maayos.. Shout out sau lodi Arjun Dano

  • @ParengKuyakoyTvTIPSIDEA1987

    lets go sana maging mag kaibigan din tayo sir i love you construction works

  • @patrickobrien5367
    @patrickobrien5367 Před 3 lety

    Good morning from lreland keep up the good 👍 work

  • @jessvista
    @jessvista Před 3 lety +1

    thanks sa video

  • @manuelpondivida9337
    @manuelpondivida9337 Před 3 lety +2

    Informative video👍... just a note, yong concrete mixture ratio (1-3-3) sa footing, sabi mo.... pwede na yan😢, so para sa akin , it sounds na meron pang mas matibay na concrete mixture ratio sa footing? Yong spacing nang tie beam stirrups, pwede naman cguro na 5cm (2”) or 10 cm fm end to end? Material costs lang cguro ang concerned kaya may spacing? Ty

    • @manuelpondivida9337
      @manuelpondivida9337 Před 3 lety

      👍👍👍

    • @larrysantos2246
      @larrysantos2246 Před 3 lety +1

      Generally, if you want to meet the 3000PSI compressive strength ng concrete for slab, beam, footing at column, as a standard practice for building a house, you have to go to this mixture proportion of 1:2:3 0.5 which means, sa isang bag ng semento, 2 timba ng buhangin (Boysen 16 ltr. pail) at 3 timba ng graba G grade at 20 liters of water. 1:2:4 0.5 is also an acceptable ratio.

  • @luisquejano2423
    @luisquejano2423 Před 3 lety +3

    Collum should be same 16mm and 12 mm stirrup

  • @rudyfernando916
    @rudyfernando916 Před 3 lety

    Good job gumagamit kayo ng vibrator. Kasi kahit first class ang concrete mix kung may ampao na parte ang buhos weak pa rin ang finish product.

    • @samarayan35
      @samarayan35 Před 3 lety

      Ano solution pag nag aampao ung concrete sir?

  • @norbertoparejr1650
    @norbertoparejr1650 Před 3 lety +3

    Sir question po ano po ang right na lalim ng ground tie beam na naka connect sa mga column bago mag buhos?thanks you po....

  • @power3545
    @power3545 Před 3 lety +1

    Ang ganda

  • @oscaraddon1148
    @oscaraddon1148 Před 3 lety +1

    Anong dapat na size ang footing ng pang two stories na bahay.

  • @richardlei1391
    @richardlei1391 Před 3 lety +1

    Sir ang vertical reinforcement ng poste meron concrete nakadikit dapat lilinisan yan bago buhusan if magbubuhos ng column.

    • @acetvph7587
      @acetvph7587  Před 3 lety

      opo lalo na kapag makapal tlga nakadikit sa bakal

  • @ronieburce2820
    @ronieburce2820 Před 3 lety +1

    2 storys ba yan ilang bakal ang gamit sa poste at ano sukat nyan 16mm ba?

  • @bentambling5672
    @bentambling5672 Před 3 lety +2

    Ang standard na templa 1:2:3 a 17 to 20 L ng tubig

  • @kennethclark7290
    @kennethclark7290 Před 3 lety +1

    Unang part ng video bakit hindi ipinagsabay ang bottom at top bars? saka ilagay ang mga stirrups. Delaying tactics?

    • @chanrobspierre5840
      @chanrobspierre5840 Před 3 lety +1

      diskarte q jan d q muna ifix lateral ties ng columns pra free moving ang main bars ng ftb.

  • @mariaarroyo5223
    @mariaarroyo5223 Před 3 lety +1

    👍

  • @luisquejano2423
    @luisquejano2423 Před 3 lety

    Wala bang epoxy coated na tie wire #16 at Yung spacing ng beam for ground is beside the collum should be 5pcs 5cm..15cm the rest and stirrup should be 12mm and vertical should be 16 mm for the 2story house

  • @jesselhoffmann2799
    @jesselhoffmann2799 Před 3 lety

    Ilang floor ba ang pinapagawa? Kc kasaluyan nagpapatayo din ako nag start sila last 2 weeks. Gusto ko sana i share ang pictures while ginawa din nila ang footing or buhos. Mas gusto ko yang ginawa nyo.

  • @noracandari4522
    @noracandari4522 Před rokem +1

    sir ok lang ba na 4 meters ang distance bet column footing?

    • @acetvph7587
      @acetvph7587  Před rokem

      yes po .. pero meron mababago sa design ng structural po.. sa laki ng poste o biga at ano gagamitin bakal.. Hindi po ako structural engineer para masagot ng sakto ang katanungan nyo pero ang alam ko ay pwede po.. dpnde lng sa structural analysis

  • @noverdepaynos171
    @noverdepaynos171 Před 5 měsíci

    Tanong po idol, hindi po ba itinatali yong bakal ng tie sa bakal ng column?

  • @pong3753
    @pong3753 Před rokem +1

    Sa ating footing kailangan malakas xa na kayang buhatin ang lahat ng load ng bahay gaya ng dead load ang live load at kailangan atlist 3000psi or higit pa sana ang lakas or 21Mpa sana ganun din ang columns.. mali po yung buhos nyo na 133,.. mahina po yan... Ok sana 124 or 123....

  • @kniveskullchua5303
    @kniveskullchua5303 Před 3 lety +1

    Tanung pra sa tie beam.. pwde b ang 4 na 12mm at 1-10mm lods? .20x.30 ?

    • @acetvph7587
      @acetvph7587  Před 3 lety

      Pde nmn kung bungalow.. pero pg 2 storey gawin mo man lng RSb 16mm ang main bar

  • @rollijo
    @rollijo Před 3 lety +3

    Pare, sa lugar ba ninyo walang lindol? Ang Pilipinas ay nasa earthquake zone, sa aking pagkakaalam kung may lindol sa lugar na pagtatayuan ng structure ang dapat na gawing rebar (reinforcing bar) hooks ang recommended end hooks ng "Stirrups" (tawag sa beams or girders) at "Ties" (ang tawag para sa columns) ay 135° Seismic Stirrups and Tie Hooks both ends na iba sa na-install sa column ties sa video na combination ng 90° at 180° kasama na rin sa video ang footing tie beam "stirrups" na 90° na dapat 135° hooks. Ang "16mm" main rebars ng footing tie beam na 90° bend ay dapat (for 16mm rebars only: 12d + 1/2 of 95mm + bar diameter = 250mm (10 inches) total hook length minimum). Refer to STANDARD HOOK DETAILS
    in accordance with ACI 318 Building Code and CRSI (Concrete Reinforcing Steel Institute) Tables.

  • @generdagdag4889
    @generdagdag4889 Před 3 lety

    Wow bossing ,hirap talian nung mga stirrups ng tie beam nyan..mtatagalan pa

  • @geraldclarito
    @geraldclarito Před 3 měsíci

    Sir, ask ko lang po. bahay ko balak kng i extend or pa gawaannko ng slab kaso wla syang footing tie beam ba yun sa pina ka groundfloor nya...bali po yung posti at saka hollowblock lng ang nkabaon mga 3 pirasong hollowblock kakayanin kaya yung slab ko sir?? buhusan kasi ng simento.

  • @simpliciocamirino2271
    @simpliciocamirino2271 Před 3 lety

    pa shoutout naman dyn,sir,baka pwede moakong gawing trabahate,hhehe,joke lang,sir.

    • @acetvph7587
      @acetvph7587  Před 3 lety

      cge po.. no problem
      busy lng me ngaun sa mga project,. hnd n mkpagvideo
      pwede basta pagbilaoin hehe

  • @isaiah6423
    @isaiah6423 Před 2 lety +1

    11:54 dpat yung stirrups mo sir salitan.halos lahat nsa taas yung dugtongan

  • @foursisters674
    @foursisters674 Před 3 lety +1

    Ilang metro po ang space bawat poste sir?

  • @rottweiler4125
    @rottweiler4125 Před 2 lety +1

    Bagong viewer at bagong subscriber mo lodi,..sakto mga video's mo na sa tulad ko naghanap ng mga idea sa pag papatayo ng bahay ko..... Tanong ko lang lodi, sa 4 to 5 meters na layo nang COLLUM, (poste). Ok lang ba na gamitin [ 2pc na 16MM] and [4pcs na 12MM] na mga MAIN BAR para sa FOOTING TIE BEAM???AT ilang ang tamang kapal at lapad ng FOTTING TIE BEAM??.
    ....para yan lodi sa 2 STOREY HOUSE.. Thank you lodi ang and god bless..

    • @acetvph7587
      @acetvph7587  Před rokem

      pwede nmn po pero much better kahit 4 ung 16mm and 2 lang ung 12mm panggitna

  • @nestorgonzales3460
    @nestorgonzales3460 Před 3 měsíci

    Hindi ba pwede gunamit ng formula sa beam? Commonly used ay L/4.. para malaman Ang spacing..? .educate me sir...t.y .

  • @kennethcariaga5808
    @kennethcariaga5808 Před 2 lety

    Sir tinatali ba ng alambre Yung dulo ng bakal papasok Don sa column? Dba Naka squal a po Yun? O ipapasok lng na parang Naka dikit sabay lagyan alambre? At same proce po ba Yun sa second floor ( slab)

    • @acetvph7587
      @acetvph7587  Před 2 lety

      madali pong paraan ung itatali ung dulo ng bakal sa column para mailagay yung stirrups.. isang paraan p po ay binubuka ung stirrups sabay isisingit sa lahat ng bakal sa column para maipasok tapos sabay ang pagtatali sa bawat spacing na nakaassign sa bawat stirrups

  • @jonknows5247
    @jonknows5247 Před 3 lety

    Substandard halo nyo. Stirups panahon pa ni kopong kopong

  • @joshuacanas9021
    @joshuacanas9021 Před 5 měsíci

    My klang kpa lodi dapat nlagyan mo mona yn ng grava bgo ka nagbakal para sa tie Beam

  • @edwarddelacruz9301
    @edwarddelacruz9301 Před 3 lety +1

    Idol ask ko lng po balak ko po kasi magpagawa ng 2 storey maliit na area lng po 4x7 let say 30sqm. Bali ilang column po at ano po size ng bakal at combination sa isang column? Pati po sa biga.marami salamat po

    • @edwarddelacruz9301
      @edwarddelacruz9301 Před 3 lety

      @@acetvph7587 marami salamat po idol mga magkano po kaya estimated cost labor at materyales kapag rough finished lng po fully structural with block works and plastered in and out. 30sqm x 2 total of 60sqm. Godbless idol napakaimformative ng content mo. Wait ko po reply mo idol.salamat

  • @budgetarianboy3607
    @budgetarianboy3607 Před 3 lety

    Boss, ano ba dapat i una pag buhos footing tie beam o column tapos tie beam na?

  • @marvinesteron9914
    @marvinesteron9914 Před 3 lety +1

    nagtipid sa porma kaya lng dami waste sa concrete ng tie beam

    • @acetvph7587
      @acetvph7587  Před 3 lety +1

      Pabor p nga po yan sa may ari kasi hnd nmn namin tinitipid yung sa concrete although natipid nmn namin ung porma. Mas tumibay nmn pundasyon kasi mas lumaki conrete cover

  • @berisopaul4939
    @berisopaul4939 Před 3 lety +1

    boss ask ko lang po...ang size ba ng bakal mo eh 16x16? pwede po ba s pag 2 story 4 ang 16 x 16 abd ung dalwa n bakal 12x12

  • @manuelpatawaran5504
    @manuelpatawaran5504 Před 3 lety

    One factual observation is... Walang gravel sa ilalim ng tie beam...4 inches minimum and tamper Dapat....

    • @acetvph7587
      @acetvph7587  Před 3 lety

      it depends again the scenario or yung status ng lupa. Matigas n po kasi yung lupa kaya no need for gravel bedding unlike dun sa talagang maputik na kahit may gravel bedding na ay nalubog pa. Watch my next episode and makikita nyo po ang tunay at matibay na paggawa ng pundasyon. Meron rin po kayo makikita dun gravel bedding na 4" ang thickness bago buhusan ng konkreto. Watch my Episode 5B . Ito po yung link
      czcams.com/video/honJKeTST4s/video.html

    • @manuelpatawaran5504
      @manuelpatawaran5504 Před 3 lety +3

      @@acetvph7587 pls... don't be offended..The proper terminology is soil density..Walang scenario o status ang lupa..Ang purpose ng gravel under foundation has nothing to do with compression load...It's all about water irrigation or drainage... Remember... concrete is a porous material... meaning....it absorbs water or moisture...And water promotes rebar rusting...Ang maling akala ng maraming pilipino..Ang bakal ay hindi kinakalawang pag nakabaon o lubog sa semento... This is the reason why Harrison plaza is about to be demolished after 50 years as stated in building code of the Philippines...The simplest way to test soil density is.....by using SOIL LOAD TESTER...A more advanced method is using GPR...or ground penetrating radar...

  • @bobbycaranto944
    @bobbycaranto944 Před 3 lety

    Tama ba dinig ko ang mix mo sa concrete mixer, 3 gravel, 1 bag cement at 3 sand? Tama ba yung mix? Ang alam ko the right mix for M20 is 1: 1.5: 3, pls correct me if I am wrong. thanks.

    • @acetvph7587
      @acetvph7587  Před 3 lety

      wrong

    • @larrysantos2246
      @larrysantos2246 Před 3 lety +1

      Generally, if you want to meet the 3000PSI compressive strength ng concrete for slab, beam, footing at column, as a standard practice for building a house, you have to go to this mixture proportion of 1:2:3 0.5 which means, sa isang bag ng semento, 2 timba ng buhangin (Boysen 16 ltr. pail) at 3 timba ng graba G grade at 20 liters of water. 1:2:4 0.5 is also an acceptable ratio.

  • @twopiecez5226
    @twopiecez5226 Před 2 lety

    Saan unang maglagay nang dowels?? Sa tabi ba nang poste??

  • @arjiemeregildo1164
    @arjiemeregildo1164 Před 2 lety +1

    Sir napansin ko lang mga anelyo yong hook nya dapat naka 135 degree

  • @arnelmercado8014
    @arnelmercado8014 Před 3 lety +1

    Bossing anong gamit mng splice sa mga Bakal mo

  • @anthonyvillanueva730
    @anthonyvillanueva730 Před 3 lety +1

    Boss kailngan ba sabay sabay buhos ng lahat ng tie beam.thanks.

  • @leoawag8515
    @leoawag8515 Před 3 lety +1

    Ask Lang po sir puidi ba hawing flooring ang plywood na pholinoed board? Thank you p.o. sir

    • @richardlei1391
      @richardlei1391 Před 3 lety

      boss matibay ang PHENOLIC BOARD kaso mas mahal kesa plywood pwede yan gawin flooring.

  • @benjiedomado2216
    @benjiedomado2216 Před 3 lety

    Sir, matanong ko lng hindi ba kilangan ang concrete blinding?

  • @Christian_calayag
    @Christian_calayag Před rokem

    Boss baka naman😅😅

  • @atromitos88
    @atromitos88 Před rokem

    gaano po kalalim footing sa 2storey at ano size ng parilya. ty po

  • @finnandcocoblogs
    @finnandcocoblogs Před 3 lety +1

    Ilang storey Yan boss?

  • @dep1912
    @dep1912 Před 2 lety

    Hindi na ba popormahan ung tie beam? Ung pinaka lupa na ung porma?

    • @acetvph7587
      @acetvph7587  Před 2 lety

      Opo para tipid.. Pero dun sa iba na malaki sasakupin ng buhos po ay need namin lagyan ng porma sa sidings.. dpende po

  • @kennedymagtoto974
    @kennedymagtoto974 Před 3 lety

    Hindi naka squala yung bar sa kanto sa may poste

  • @elvinporquiado4286
    @elvinporquiado4286 Před 24 dny

    sir pwede po kayo sa bulacan area? new subscriber, salamat po sa sagot.

  • @generdagdag4889
    @generdagdag4889 Před 3 lety

    Eh kung malambot pa ung lupa at natitibag pa...tagal

  • @lagriojoey9014
    @lagriojoey9014 Před 3 lety +1

    Sir ask qo lng kung ilang feet ung lalim nang tie beam po sir

  • @davejhay4109
    @davejhay4109 Před rokem

    Ip structure analysis nyo sa engineer kse malalakas ang earthquake sa bansa nten nowadays pag daring pa ng draribv na panahon

  • @GISBERTJUNIO
    @GISBERTJUNIO Před rokem

    boss. mali yung stirrups mo. dapat hindi 90 degress yung bend ng dulo nyan.dapat naka 135 degree bend po yan. wag po banat ng banat. gagawa na din lang kayo ayusin nyo na.kawawa may ari ng bahay po

  • @richardlei1391
    @richardlei1391 Před 3 lety +1

    boss di pwede tansa2x ang water cement ratio.

    • @gnidnoeled786
      @gnidnoeled786 Před 3 lety

      Sa concrete mix ratio na 1:2:3 ang tubig dito ay 0.5, ang minimum na strength ng mix ratio na to ay 3,000 psi. Better kung nasa tamang mix ratio ang concrete at ang tubig ay tama.

    • @richardlei1391
      @richardlei1391 Před 3 lety

      @@gnidnoeled786 boss ang 3,000psi ang mix ratio ay 1:3:3 ang 1:2:3 ang psi niyan ay nasa 4,000 ang 1:2.5 :5 ay 3,500psi ang 1:2:2 ay 4,500 psi at ang water cement ratio ng 1:2:3 ay nasa .45 to .50

  • @michaelgu9907
    @michaelgu9907 Před 3 lety

    Boss anong sukat ng poste mo pag nabuhusan? 12x16 ba?

  • @nicoafilipinovlogdogiesand2548

    sir yung bang mga intersection ng mga column at beam talagang hindi ito tinatali ? kunyari kahit sa 2nd floor ?

    • @acetvph7587
      @acetvph7587  Před 3 lety +2

      tinatali po namin yan, Yung iba patong lang sa stirrups pag may hook..

  • @NumberSense101_MervhieCalma

    Sa bungalow sir anu minimum size ng bakal?

  • @waynekyu5377
    @waynekyu5377 Před 3 lety

    Sir tanong po kung may existing na bahay ka na po tas balak mong mangpadagdag ng kwarto pano na po yung dugtongan ng tie beam sa dati ng nabuhusan na column?

  • @lipongko2519
    @lipongko2519 Před 2 lety

    sir, Plano ko pataasan ang ang bahay ko, row hause na pabahay pader Lang ang pagitan, 4x6meter, kung ang poste ko ay 6 kailangan pa ba Ng tie beam?

  • @pablobanna6853
    @pablobanna6853 Před 3 lety +1

    Ground beam ang tawag sa ilalim

    • @anglaruan6728
      @anglaruan6728 Před 3 lety

      Hindi, Plinth or Tie Beam ang right term jan.

  • @bukidloverfamily9451
    @bukidloverfamily9451 Před 2 lety

    Master baho pa Ako naka panood sa vlog my ta nong lang Ako sa halege Ano Ang sokat nang ring bar

    • @acetvph7587
      @acetvph7587  Před 2 lety

      yung ring bar po ay column ties tawag kapag sa poste.. sa biga nmn po ay stirrups. bale 15cm x 25cm sukat ng ties namin para sa 25cm x 35cm n poste

  • @norbertoparejr1650
    @norbertoparejr1650 Před 3 lety

    Sir pwede po magtanong ask ko lng kung anong magandang lalim ng mga tie bar na naka connect sa mga column bago mag pouring ng cement

  • @ronitomoto5589
    @ronitomoto5589 Před 3 lety

    Mas maganda nga yung malapad ang buhos Sa footing? Lodz matibay

  • @PeterParker-hf8ok
    @PeterParker-hf8ok Před 3 lety

    Hello kuya, ok lang po ba may kalawang ung rebar or mas maganda galvanised po?

    • @acetvph7587
      @acetvph7587  Před 3 lety

      okie nmn po.. wag lang po yung kalawang na kalawang na na wala nang tibay.. kadalasan po gawa lang po ng ulan, nagkakaroon ng kalawang pero hnd nmn po yung loob pa kinakalawang.., yung outer side pa lng kadalasan.. gawa ng moist

    • @PeterParker-hf8ok
      @PeterParker-hf8ok Před 3 lety

      @@acetvph7587 kayo po bay batangeuno?

    • @acetvph7587
      @acetvph7587  Před 3 lety

      Hnd po. Tga quezon po ako

  • @bronegsph6422
    @bronegsph6422 Před 3 lety

    Idol ano standard nyo ng pagitan ng dowel mula sa poste para sa asentad Hindi po nabangit

    • @acetvph7587
      @acetvph7587  Před 3 lety

      40cm vertical, 60mm horizontal para sa CHB laying or asinta.

  • @jorpakzenduro9375
    @jorpakzenduro9375 Před rokem

    Boss ano po size ng rebar sa footing tie beam? Salamat po.

  • @martelrivera1135
    @martelrivera1135 Před 2 lety

    Anong size ng bakal ang nasaposte nyo?

  • @roronecosia9562
    @roronecosia9562 Před 3 lety

    Hello po bagong kaibigan po dto sir
    Itong ground lay out po Ba ai ganon din kng mag second floor? Please respect my comment
    God bless po at sa lahat.

  • @jerrygonzales51
    @jerrygonzales51 Před 3 lety

    questions: pwede ba sir iangat ang footing tie beam sa above o same natural ground level kasi me tambak ang bahay eh? (on engineering standard) kapag ba merong tie beam? kailangan pa ba ng wall footing? thanks po

    • @manuelpondivida9337
      @manuelpondivida9337 Před 3 lety +1

      Yong yatang tie bean footing, yan ang magiging wall footing( laying platform of CHB)kc meron dowels?

    • @marloujaymomo4760
      @marloujaymomo4760 Před 2 lety +2

      yung tie-beam general term yan. footing tie-beam kung nasa footing malapit ang kanyang location.. plinth beam naman kung naka lapag siya sa natural grade line.
      marami klase ng beam. pero ang main function niya is mag kabit sa column para mas maging kapit at less slender ang bawat column at maging matibay ang structure

  • @nestorsalarda9765
    @nestorsalarda9765 Před 3 lety

    Gud evening sir asklg ilan floor ba ung ginagawa nyo.at anung size ng.bakal nyo sa poste?salamat

    • @acetvph7587
      @acetvph7587  Před 3 lety

      2 storey po.. 16mm bakal ginamit namin., min. of 6pcs each column

  • @pogishow2833
    @pogishow2833 Před 2 lety +1

    Pinahirap nyo lng trabaho nyo.

  • @oceantv.21oceanbase65
    @oceantv.21oceanbase65 Před 2 lety

    Mali nmn yung spacing

  • @Ray_Marts
    @Ray_Marts Před 3 lety

    Hindi po ba sir baliktaran ang pagtakid nung square na bakal sa beam?

    • @acetvph7587
      @acetvph7587  Před 3 lety

      nice question.. Maganda tlga baliktaran pero pde rin nmn hnd.
      Depende rin sa application lamang

    • @Ray_Marts
      @Ray_Marts Před 3 lety

      @@acetvph7587 salamat sa reply sir. . .

    • @acetvph7587
      @acetvph7587  Před 3 lety +1

      @@Ray_Marts mas gawin natin ng tama kapag malakihang project ka lodi.. sasample-lan kita minsan.. next project namin para mas tama ipakita ko tlga at as is sa plan tlga

    • @Ray_Marts
      @Ray_Marts Před 3 lety

      @@acetvph7587 ok sir abang lang ako

  • @bronegsph6422
    @bronegsph6422 Před 3 lety

    Boss pag Wala si engineer 1/5/5 na kase ratio ng buhos masyadong maaksaya sa semento malologi si amo at Ang Sabi ni forman pag Wala materyales walang pasok Kaya tipid tayo sa semento pag Wala sa camera

  • @BoyHongkong
    @BoyHongkong Před 3 lety

    Magkano mag rent ng mixer per day ba?

  • @marvinnumeral6011
    @marvinnumeral6011 Před 3 lety

    eto layout na my 2nd floor? or ground lng?

  • @lyndonpaullee8830
    @lyndonpaullee8830 Před 3 lety

    Kalodi Sir, Question lng. If 12mm-6pcs/10mm Stirrups kada Poste (6pcs na poste) kaya nya po ang load sa Tie beam sa taas na 16mm.
    *4x10 po size ng bahay.

    • @acetvph7587
      @acetvph7587  Před 3 lety

      gawin nyo n po 16mm mga bakal na gagamitin sa poste.. wag n po 12mm lang kung para sa 2 storey.. kung one storey lang nmn okie n po ung 12mm

  • @BoyHongkong
    @BoyHongkong Před 3 lety

    Meron din bang narerentahan na concrete vibrator diyan sa pinas?

    • @mikenav5326
      @mikenav5326 Před 3 lety +1

      Meron po sir. Uso naman yan dito.

  • @MegaCelman
    @MegaCelman Před 3 lety +1

    3

  • @pekongpekong1106
    @pekongpekong1106 Před 3 lety

    Ilang cm ba ang lalim nyan..at ilang floor po yan boss

    • @arneltamayo1746
      @arneltamayo1746 Před 3 lety

      10x8meters sir tag 8pcs na 16mm ang poste..4mx4m ang agwat bawat poste ok lang ba.tas yung tie beam pwede 12mm na apat.tnx po

  • @haroldcapuno2518
    @haroldcapuno2518 Před 3 lety

    Bossing,pwede ba gawing 20x30 ang column?bongalow style lng po ang bahay..

    • @acetvph7587
      @acetvph7587  Před 3 lety +1

      oo nman boos lodi.. malaki n yun para sa bungalow

    • @haroldcapuno2518
      @haroldcapuno2518 Před 3 lety

      @@acetvph7587 salamat boss sa reply.my idea na po akong nakuha sa video mo salamat....

    • @haroldcapuno2518
      @haroldcapuno2518 Před 3 lety

      @@acetvph7587 boss,pwede pa kaya gawing 6x12 inch?medyo nagtitipid boss eh.ilang bakal kaya ang ilagay?12mm ang gamitin.bali 6 lahat.

    • @acetvph7587
      @acetvph7587  Před 3 lety

      Pwede nmn boss lodi.

    • @acetvph7587
      @acetvph7587  Před 3 lety

      Pde n kahit 4 n 12mm sa pinakang tipid.. wag nmn 10mm lng.. much better p din anim n piraso

  • @conradotescalajr2912
    @conradotescalajr2912 Před 3 lety

    Anong sugat ng sterap ninyo boss

  • @rowelmabazza1052
    @rowelmabazza1052 Před 3 lety +1

    Dapat binanggit mo kung 2nd floor yan kc kapag 2nd floor yan mali ung pagkabit sa mga bakal.

  • @markanthonyalbos1135
    @markanthonyalbos1135 Před 3 lety

    Ilang bakal Ang nagagamit sa isang posts?.

  • @EuropeTruckersPinoy
    @EuropeTruckersPinoy Před 3 lety

    Matamlay panoorin, wlang tamang info... pero pinanood ko pa rin pra makakuha ako ng idea kpg nagpatayo ako ng bahay ko...

  • @urieltadlas8641
    @urieltadlas8641 Před 3 lety

    ano ang tamang spacing sa stirup ng pilar

    • @acetvph7587
      @acetvph7587  Před 3 lety

      5sets na 5cm spacing simula sa parilya, 5 sets ng 10cm spacing..the rest 20cm

  • @kennedymagtoto974
    @kennedymagtoto974 Před 3 lety

    Mhirap mag tali dyan

  • @oliverumerez5531
    @oliverumerez5531 Před 3 lety

    boss ano po ba ang standard na mixture 1*2*3 po ba 1*3*3 ano boss mas mganda gamtin

  • @samarayan35
    @samarayan35 Před 3 lety

    Sir ung tie beam nyo, diba may concrete cover po yan , pano nyo nilagyan ng concrete cover sa bottom portion?

    • @acetvph7587
      @acetvph7587  Před 3 lety

      binase po namin yan sa layout ng batterbboard at hinulugan kaya sa pagkasa ng bakal ay may space n po para sa concrete cover

    • @pogijuliano479
      @pogijuliano479 Před 3 lety

      Tsaka Pansin ko lng din, hindi po ba dapat Alternate lagi pag lagay ng Stirrup yung Mga dulo ng Stirrup boss?? Pansin ko kasi sa beam halos nsa ibabaw lahat yun dulo ng Stirrup, okay lang po ba ba pag ganun???

    • @nathpolido9964
      @nathpolido9964 Před 3 lety

      nakaangat na yan sa ilalim may space na yan for concrete cover matic na yun .. alam nila yan...

  • @alejandrobandong
    @alejandrobandong Před 2 lety

    Ilang floor po gagawin

  • @urieltadlas8641
    @urieltadlas8641 Před 3 lety

    gaano ka lalim sir ang foundation ng pilar

  • @zackliwanagan8219
    @zackliwanagan8219 Před 3 lety

    ano sukat ng footing tie beam mo sir at ano ang lalim nyan?

    • @zackliwanagan8219
      @zackliwanagan8219 Před 3 lety

      @@acetvph7587 salamat bossing ng marami .more power to you!

  • @otse3329
    @otse3329 Před 3 lety

    gaano kakapal ang footing?

    • @acetvph7587
      @acetvph7587  Před 3 lety +1

      350mm

    • @otse3329
      @otse3329 Před 3 lety

      @@acetvph7587 pag 10x10inches na poste ng fence bosing 350mm parin ang kapal ng footing? o pwd manipis konti? salamat.

  • @rogeliobicasjr3031
    @rogeliobicasjr3031 Před 3 lety

    ansikip ng hukay nyo lodi popormahan pb yan o wla na

    • @acetvph7587
      @acetvph7587  Před 3 lety

      wala n po lodi., yung hukay na po magsisilbing porma

  • @jessiegregorio3328
    @jessiegregorio3328 Před 3 lety

    Bkit naglaki pa kayo ng hukay sa poste eh my harang din

    • @acetvph7587
      @acetvph7587  Před 3 lety

      napasobra lng lodi ng hukay sa iba.. hnd maiiwasan na perfect.. Depende sa lupa kung matigas o malambot lupa

  • @ailynalino7636
    @ailynalino7636 Před 3 lety

    Boss ano sukat ng poste nyo gusto ko gayahin kasi

  • @manuelpatawaran5504
    @manuelpatawaran5504 Před 3 lety +1

    It's better to use BI wire compared to GI wires...

    • @acetvph7587
      @acetvph7587  Před 3 lety

      yes but G.I. Wires are commonly use..

    • @manuelpatawaran5504
      @manuelpatawaran5504 Před 3 lety

      @@acetvph7587 BI has a higher tensile strength compared to GI..GI wires has been commonly used in the Philippines for almost 100 years..yet other countries have been upgraded to BI wires...Sa kawad pa lang yan na pangtali... Wala pang fiberglass rebar at basalt rebar sa pinas...

  • @urieltadlas8641
    @urieltadlas8641 Před 3 lety

    sir anu ang tamang sukat sa ground beam, at anung sukat din sa 2nd floor beam, pkisagot sa chat or text sir

    • @acetvph7587
      @acetvph7587  Před 3 lety

      25cm x 40cm po ginawa na in sa ibaba,., 20cm x 30cm sa taas

    • @richardlei1391
      @richardlei1391 Před 3 lety

      Lodi di ba sa footing tie beam mas malapad ang width kesa sa depth?

    • @anglaruan6728
      @anglaruan6728 Před 3 lety

      Depende yan sa structural analysis ng engineer. Wlang standard na size na sinusunod sa mga Beams, footings at columns. Magvavary yan depende sa loadings, design at external factor ng bahay na itatayo.