HOW TO INSTALL SPD || Surge protection device for home || electrical safety

Sdílet
Vložit
  • čas přidán 8. 08. 2023
  • Contact for promotions- thetechmanoffice@gmail.com
    single phase- www.amazon.in/Phoenix-Contact...
    three phase- www.amazon.in/SPD-Grey-Remote...
    Surge Protective Devices (SPD) are used to protect the electrical installation, which consists of the consumer unit, wiring and accessories, from electrical power surges known as transient overvoltages.
    They are also used to protect sensitive electronic equipment connected to the installation, such as computers, televisions, washing machines and safety circuits, such as fire detection systems and emergency lighting. Equipment with sensitive electronic circuitry can be vulnerable to damage by transient overvoltages.
    The effects of a surge can result in either instant failure or damage to the equipment only evident over a longer period of time. SPDs are usually installed within the consumer unit to protect the electrical installation but different types of SPD are available to protect the installation from other incoming services, such as telephone lines and cable TV. It is important to remember that protecting the electrical installation alone and not the other services could leave another route for transient voltages to enter the installation.
    There are three different types of Surge Protective Devices:
    Type 1 SPD installed at the origin, e.g. main distribution board.
    Type 2 SPD installed at sub-distribution boards
    (Combined Type 1 & 2 SPDs are available and are usually installed in consumer units).
    Type 3 SPD installed close to the protected load. They must only be installed as a supplement to Type 2 SPD.
    Where multiple devices are required to protect the installation, they must be coordinated to ensure correct operation. Items supplied by different manufacturers should be confirmed for compatibility, the installer and manufacturers of the devices are best placed to provide guidance on this.
    What are transient overvoltages?
    Transient overvoltages are defined as short duration surges of electricity which occur due to the sudden release of energy previously-stored or induced by other means. Transient overvoltages can be either naturally occurring or man-made.
    How do transient overvoltages occur?
    Man-made transients appear due to switching of motors and transformers, along with some types of lighting. Historically this has not been an issue within domestic installations but more recently, installations are changing with the advent of new technologies such as electric vehicle charging, air/ground source heat pumps and speed-controlled washing machines have made transients much more likely to occur within domestic installations.
    Natural transient overvoltages occur due to indirect lightning strikes most likely to happen due to a direct lightning strike on an adjacent overhead power or telephone line causing the transient overvoltage to travel along the lines, which can cause significant damage to the electrical installation and associated equipment.
    Result in serious injury to, or loss of, human life; or
    Result in interruption of public services and/or damage to cultural heritage; or
    Result in interruption of commercial or industrial activity; or
    Affect a large number of co-located individuals.
    This regulation applies to all types of premises which include domestic, commercial and industrial.
    In the previous edition of the IET Wiring Regulations, BS 7671:2008+A3:2015, there was an exception for some domestic dwellings to be excluded from surge protection requirements, for example, if supplied with an underground cable, but this has now been removed and it is now a requirement for all types of premises including single dwelling units. This applies to all new build and properties being rewired.
    Whilst the IET Wiring Regulations are not retrospective, where work is being carried out on an existing circuit within an installation which has been designed and installed to a previous edition of the IET Wiring Regulations, it is necessary to ensure the modified circuit complies with the latest edition, this will only be beneficial if SPDs are installed to protect the whole installation.
    The decision on whether to purchase SPDs is in the hands of the customer, but they should be provided with enough information to make an informed decision on whether they wish to omit SPDs. A decision should be made based on safety risk factors and following a cost evaluation of SPDs, which may cost as little as a few hundred pounds, against the cost of the electrical installation and equipment connected to it such as computers, TVs and necessary equipment, for example, smoke detection and boiler controls.
    It is also worth checking with your insurance company as some policies may state that equipment must be covered with an SPD or they will not payout in the event of a claim.
  • Věda a technologie

Komentáře • 23

  • @Redtruthlion
    @Redtruthlion Před 8 měsíci

    SPD k liye alag say earthing ki wire Jamin may dalwani padti hai kyaa

    • @techmansukhpal
      @techmansukhpal  Před 8 měsíci

      Yes

    • @23saurabhdethe96
      @23saurabhdethe96 Před 5 měsíci

      Sir Kya mai Alag earthing krne ka Reason jaan sakta hu​@@techmansukhpal

    • @techmansukhpal
      @techmansukhpal  Před 5 měsíci

      Kyunki SPD surge ke liye hai. Jo ki 11KV ki line se bhi aa skti hai. Or agr ghr mein dusri earth se jodenge to three pin sockets mein ja skti hai surge
      Or wahan se appliances ki body mein

    • @23saurabhdethe96
      @23saurabhdethe96 Před 5 měsíci

      @@techmansukhpal thanks you sir

    • @Redtruthlion
      @Redtruthlion Před 5 měsíci

      @@techmansukhpal ok thanks🙏

  • @puranprakashdave
    @puranprakashdave Před 5 měsíci +1

    अनुपम

  • @ankurbharali917
    @ankurbharali917 Před 10 měsíci

    Bhai maine spd lagaya tha but voo jal gaya kis wajah se jali hai aap bata sakte hai ?

    • @techmansukhpal
      @techmansukhpal  Před 10 měsíci

      Usne apna kaam kiya isiliye jal gya. Surge aa gyi hogi

  • @ctetbtetacademy1516
    @ctetbtetacademy1516 Před 5 měsíci +1

    440V होने पर ये SPD किसी उपकरण को खराब होने से बचा सकता हैं क्या।

    • @techmansukhpal
      @techmansukhpal  Před 5 měsíci

      440V to normal voltage hain three phase mein

    • @ctetbtetacademy1516
      @ctetbtetacademy1516 Před 5 měsíci

      440V(यानी अर्थ भी फेज हो जाता हैं) से SPD किसी उपकरण को खराब होने से बचा सकता हैं क्या

  • @barafwal253
    @barafwal253 Před 3 měsíci

    Namaste ,
    Mujhe single phase ke liye ghar mein SPD lagaani hai. Kaun si purchase karoo sir?
    Single pole or Double pole?
    Single pole mein sirf 1 SPD de rahe online.
    Kya hume 2 SPD combine lagwana compulsory hota hai jisme 1 phase ka wire aur doosra Neutral wire lagana hota hai?
    Yaa bas ek akeli SPD leke usme Phase ka wire laga de aur neutral direct connect kar de?

    • @techmansukhpal
      @techmansukhpal  Před 3 měsíci +1

      Ese spd kaam nhi kregi. And spd koi single ya double pole nhi hoti. Vo mcb hoti hai. Aap simply single phase AC SpD type 2 order kijiye. Phonix contact company ki

    • @barafwal253
      @barafwal253 Před 3 měsíci

      @@techmansukhpal Phoenix SPD mein 335 voltage ke upar ke surge ko bypass karega jabki AMICISMART wali SPD 275 Voltage ke upar ke surge ko hi earthing karne lagegi

    • @techmansukhpal
      @techmansukhpal  Před 3 měsíci +1

      Sir 335 model mein likha hai but uska Uc 320 hota hai. And 275 voltge ko surge nhi bolte. 320 wala hi sahi rhega
      275 wala boht bar change krna pdega.

    • @barafwal253
      @barafwal253 Před 3 měsíci

      @@techmansukhpal Great advice brother, iska matlab yeh hai ki jo voltage likha hota hai, uske upar jaane par SPD kharab ho jaati hai and usse baar baar change Karo phir?

    • @dhandraraju8850
      @dhandraraju8850 Před měsícem

      Over aur under voltage device hain Jo markeet main vo is se acha hai Kiya usko earth ki bhi jarort nahi

  • @pratibhamaurya8563
    @pratibhamaurya8563 Před 3 měsíci

    Mere ghar me 11000 line baar baar aa jata hi jise pure ghar ka fan jal jata hi

  • @gujar5546
    @gujar5546 Před 2 měsíci

    इससे कोई फायदा नहीं है सिर्फ बेकुफ बनानी वाली बात है और कुछ नहीं