  • Josh Lee explains how the control piston, a mechanical part, can sometimes cause the electrical components of the total stop function not to work. Technically, it is a "mechanical" issue, but may present as an electrical problem.
    Locate Dealers:
    www.kranzleusa...
    No dealer near you? Shop direct via Dirt Killer
    www.dirtkiller...
    #Kranzle #BestElectricPressureWasher #electricpressurewasher

Komentáře • 23

  • @tb693ny6
    @tb693ny6 Před 4 měsíci

    brand new unit with this issue right out of the box,....

    • @kranzleusa5846
      @kranzleusa5846  Před 4 měsíci

      Sorry to hear this. Sometimes the trip from Germany to the USA to customers can cause problems. Given the unit is new, this should be a warranty issue. Please call us to resolve. 800.544.1188 M-F 9-5 EST.

    • @tb693ny6
      @tb693ny6 Před 4 měsíci

      @@kranzleusa5846 watched a few of your vids and resolved the issue myself thankfully!

  • @philtechGT3
    @philtechGT3 Před měsícem

    Helpful but so frustrating that the video doesn't show the actual mechanical part... camera angle is bad here

    • @kranzleusa5846
      @kranzleusa5846  Před 28 dny

      Thanks for the feedback. We can't edit the video but will try to improve in future videos.

  • @gazbullen
    @gazbullen Před měsícem +1

    Hi can the K7 be changed to a start stop machine if i buy the start/stop pressure switch and wire it in?

    • @kranzleusa5846
      @kranzleusa5846  Před měsícem +1

      This may be possible. Call and speak with Josh Lee or Patricia. 800.544.1188

  • @kamslm1155
    @kamslm1155 Před rokem

    Josh. Very helpful vid and may be the cause of the problem I am having on my 1122 right now. However, just a suggestion that you lower the camera angle a bit so we can actually see you working on the specific area. These vids are really helpful to the DIY'er who doesn't want to send an 80 lb. machine to a dealer to fix it. Thank you!

    • @kranzleusa5846
      @kranzleusa5846  Před rokem

      Thanks for the feedback. Will relay to Josh. Glad it helped. Noted on the camera angle. Hopefully the close ups gave the details you needed.

    • @kamslm1155
      @kamslm1155 Před rokem +1

      @@kranzleusa5846 Problem solved! Motor would not shut off. Likely some build-up of dirt or minerals on the piston or in the piston housing. Vid was super helpful to diagnose source of problem and also with order of the parts (brass washer, O ring, etc.). Thanks Josh! Shout out also to Patricia at tech support who spent way more time with me than I deserve!

  • @robanchaudhary4876
    @robanchaudhary4876 Před 7 měsíci +1

    Hlw josh, i am facing problem in my machine over fullystop function, i have changed my control piston and checked for all the leak with gun and other component and microswitch also doing fine job,but when i release the trigger in the gun it is not fully stop and regulator piston also vibrating ,can you suggest me solution for this problem

    • @kranzleusa5846
      @kranzleusa5846  Před 7 měsíci

      Hmm. What kind of sound does it make when "NOT FULLY stopped"? Got any video? Please do send a tech support ticket at KranzleUSA.com or give us a call. 800.544.1188

  • @AC-us1gm
    @AC-us1gm Před 4 měsíci +1

    My Kranzle doesn’t shut off when I release the trigger, when I pull the trigger I can hear what I believe is either the motor or the pump turn on, but then when I release it, something stays on. It isn’t as loud as when I’m pulling the trigger so I feel something is shutting off, but the Kranzle isn’t completely shutting off. I followed the steps to this video but I’m still having issues. The gauge stays at 0 the entire time, even when the trigger is pulled and released.

    • @AC-us1gm
      @AC-us1gm Před 4 měsíci +1

      I slept on it & the machine is in perfect working order now lol. However, I made the mistake of wiping off what I thought was random gunk from the control piston & now think it was what you guys use as lubricant. I heard in another video you guys use Vaseline as lube, can I use that here as well?

    • @kranzleusa5846
      @kranzleusa5846  Před 4 měsíci

      Yes.

  • @turbomax2001
    @turbomax2001 Před 7 měsíci +1

    I have a question about my HD7... I don't know if it's a problem or not. When no nozzle is connected to the gun, there's basically no pressure. Is that supposed to be the case? When I connect the gun (I have a Mosmatic) the pressure doesn't go over 1000psi, even when the pressure adjustment is maxed out. Is that normal?

    • @kranzleusa5846
      @kranzleusa5846  Před 7 měsíci

      Hi. Technically speaking the pump only MOVES water at whatever GPM. The NOZZLE orifice size is what creates the pressure. It's like a balloon. When you pinch the end, the air stream pressure increases. What size nozzle do you have on your Mosmatic gun?

  • @Osadude1337
    @Osadude1337 Před 5 měsíci +1

    Hi!
    My Kränzle 1150t just ”humz” when i put the power on. Then after aprox 10 sec the power button switches back to off. Do u guys have any clue what could be the problem?
    When the machine is turned off, water is comming from the pistol when I push the handle. Oscar from Sweden😊

    • @kranzleusa5846
      @kranzleusa5846  Před 5 měsíci

      A hum usually means the capacitor is shot. Super easy to replace. Here's a video:czcams.com/video/aE_s1wv4ipI/video.html

  • @datfella100
    @datfella100 Před 6 měsíci +1

    Can this cause a fuse to blow when you release the trigger from your gun after starting the washer

    • @kranzleusa5846
      @kranzleusa5846  Před 6 měsíci

      Releasing the trigger turns OFF the power.. Can't see how that would cause a fuse to blow.

  • @telim5848
    @telim5848 Před rokem +1

    Would this issue with the control piston cause any short cycling issues?

    • @kranzleusa5846
      @kranzleusa5846  Před rokem

      Hi. We are checking with Josh Lee. Will have a detailed answer shortly.