Sullair 185 Problem

Sdílet
Vložit
  • čas přidán 5. 09. 2024
  • Ehhh need help!

Komentáře • 14

  • @b00dasi
    @b00dasi Před 9 měsíci

    Compressor Sump tank is lifting safety. Need to pull apart the sump tank and replace the separator element. Could be a gummed up MPV that is stuck closed thus the air pressure is going to high for the rating of the sump. Another possibility is that the safety has failed from improper maintenance.

  • @juanolivera9361
    @juanolivera9361 Před 3 lety +1

    It’s jus a leaking relief valve

  • @carloseduardojesus169
    @carloseduardojesus169 Před měsícem

    O que fazer quando acontece isso?

  • @steve1674pas
    @steve1674pas Před 6 lety

    You ever fix it having somewhat the same issue

  • @ronaldjr7318
    @ronaldjr7318 Před rokem

    How did you fix this problem

  • @caesarroman3182
    @caesarroman3182 Před 2 lety

    Anyone figure out the problem?

  • @omarromero2696
    @omarromero2696 Před 6 lety

    I have the same problem on my compresor

  • @billjones4591
    @billjones4591 Před 5 lety

    What was wrong?

  • @davidsimpson2162
    @davidsimpson2162 Před 5 lety

    Seems like a bad mpv

    • @compressorman43
      @compressorman43 Před 5 lety

      yes

    • @robthoroughman8939
      @robthoroughman8939 Před 4 lety

      I have the same prob new thermostat new high tep shut of selenoid it runs aprox 1 min shuts down wiith high eng temp

    • @c0mp4s1
      @c0mp4s1 Před 3 lety

      I having the same problem with my

    • @c0mp4s1
      @c0mp4s1 Před 3 lety

      @@robthoroughman8939 how you fix this problem

    • @Levis52781
      @Levis52781 Před 10 měsíci

      Check minimum pressure valve