2 Zone Navien Combi Boiler System - Start To Finish - Complete How To Build Tutorial

Sdílet
Vložit
  • čas přidán 13. 10. 2023
  • This is a how to video of a complete 2 zone Navien boiler system that uses 1 zone for baseboard and 1 zone for radiant in floor heating. The video walks through an entire build from basic layout to detailed piping and wiring.
    Contact me at speranzadevelopment@gmail.com for consulting on a heating system or if you would like me to build you a system.
    venmo.com/code?user_id=340252...
    paypal.me/Speranzadevelopment@gmail.com
    SperanzaDeve...
    jsperanzatv...
    www.tiktok.com/@jim.speranza?...
    #boiler #boilers #navien #vt2218 ‎#radiant #combi #heating #hvac #plumbing #construction #home #house #renovation#renovating @NavienInc ‎@TacoHVACtv ‎@Supplyhouse
  • Zábava

Komentáře • 74

  • @T_Tongg
    @T_Tongg Před 7 měsíci +1

    Very nice Jim, very nice. Thank you for sharing.

  • @rosstheplumber1485
    @rosstheplumber1485 Před 7 měsíci +5

    SOLID GOLD VIDEO MY BROTHER . Thanks for taking the time to post and be thorough.

  • @svenhodaka9145
    @svenhodaka9145 Před 8 měsíci +1

    Beautiful. Your work is that of a true craftsman.

  • @jasonjokiel7188
    @jasonjokiel7188 Před 7 měsíci +2

    Great video , very informative. Nice work !!

  • @moealmawali8248
    @moealmawali8248 Před 6 měsíci +2

    beautiful work man i love how you explain everything

  • @lachcik5084
    @lachcik5084 Před 8 měsíci +2

    this is exactly what i want to do at my company, one day ill convince them ;)

  • @bradmarshall7075
    @bradmarshall7075 Před 6 měsíci +1

    Great video!!! Thanks for sharing all your knowledge!!!!

  • @rogerroger7734
    @rogerroger7734 Před 5 měsíci +2

    Very clean man. I’m impressed. Getting ready to build a house and watching your videos is helping better understand a cleaner board!

    • @JimSperanza
      @JimSperanza  Před 5 měsíci

      Email me at speranzadevelopment@gmail.com if you need any consulting 👍

  • @bradmefford5064
    @bradmefford5064 Před 3 měsíci +2

    Very informative! Thanks!

  • @SkilledLabor
    @SkilledLabor Před 5 měsíci +1

    Definitely a time SAVER! Nice work

  • @stevesesto9652
    @stevesesto9652 Před 5 měsíci +1

    Amazing video!. I’m heading to the Navien factory in Toronto in two weeks to go over all this. I think you’re pretty much covered it all. Maybe I could save some money ha ha ha.

  • @zionsho
    @zionsho Před 5 měsíci +1

    Nice work

  • @LumenChaser
    @LumenChaser Před 9 měsíci +2

    no magnetic filter? always put one on any high eff boiler

  • @maworleynm
    @maworleynm Před 7 měsíci +1

    This is the video I’ve been looking for! Thank you for sharing! I need to replace my combi system and the plumbers here want charge me $6000 for the Navien unit and another $10k to install it. I will definitely be reaching out to you soon about a consultation.

  • @benstowell5956
    @benstowell5956 Před 2 měsíci +2

    Hello, I’ve been watching a lot of your videos and really enjoy how you explain everything and how clean and organized your set ups are. I was curious if you could let me know what those brackets are called that you use to hold up the pipes? Also, what is the part number or name of the check valve and feed fitting that brings water into the system? Thank you very much for your response and help

    • @JimSperanza
      @JimSperanza  Před 2 měsíci +1

      Split ring clamps and ceiling plates. You can use a dual check backflow preventer for the water feed. Email me at speranzadevelopment@gmail.com if you'd like a design and parts lists or consulting on a build.

  • @kirkfowlkes1760
    @kirkfowlkes1760 Před 9 měsíci

    I'm looking to where I connect 24vt zone wiring on 240/130h circuit board

  • @vampirel1983
    @vampirel1983 Před 6 měsíci

    Nice woek Jim. Quick question where would the colde water supply line go in your system does it need a pressure reducer before it gets there

  • @Kaczerskitom
    @Kaczerskitom Před 2 měsíci

    Good evening, I have a question I was hoping you can help me answer. I have the same combi boiler installed and I tired to do my yearly flush. On the domestic side it went no problem, I recirculated the descaled for 45 minutes, but when I tried to do the main heater exchanger flush I was unable to do so because the water would not circulate. Almost as if the three way valve inside was just stuck closed. How do I open that valve so I can circulate the descaled through the heat exchanger? Any input would be really appreciated. I’m stuck I have no idea how to get past this step. PLEASE HELP.

  • @cooper8318
    @cooper8318 Před 7 měsíci +2

    So I have a question about combi boiler sizes. Id like to do a combi on a 2200 sf radiant heated slab in northern Indiana. How do you figure out what size boiler is needed to take care of the slab heat and domestic? Does a larger boiler use more gas than a smaller one in the 6 months or so that the slab heat isnt on? Is it better to get two separate boilers? Thank you

    • @JimSperanza
      @JimSperanza  Před 7 měsíci

      Contact me at speranzadevelopment@gmail.com

  • @BeeBombard
    @BeeBombard Před 10 hodinami

    Only thing I would’ve done different is add ballvalves to each side of my mixing valve in case it ever goes bad. That way it’s an easy fix for later.

  • @cmb7481
    @cmb7481 Před 8 měsíci +1

    Hello,
    I was surprised to see the manifold was open the whole way through.
    Maybe you can help me understand, why are the supply and return loops piped together outside the boiler?
    What does that do for the system?
    I answered my own question..... THAT'S A MIXING VALVE.
    Great video

    • @JimSperanza
      @JimSperanza  Před 8 měsíci +1

      The manifold is used to hydraulically seperates the flow through the boiler and the flow through the heating zones.

  • @dkevinterry
    @dkevinterry Před 18 dny +1

    I have a very old , 2 zone crane system and need a new system. I don’t see your email address to order. Great video. Thanks and look forward to getting new unit

    • @JimSperanza
      @JimSperanza  Před 18 dny

      Email me at speranzadevelopment@gmail.com

  • @andreybaskevich9839
    @andreybaskevich9839 Před měsícem +1

    Excellent video. Thank you. Is mixing valve needed for TILED (PEX inside the mud job) in floor radiant heat? Or is it only applicable for under hardwood floors?

    • @JimSperanza
      @JimSperanza  Před měsícem

      You don't want the floor surface temp to go above 85 degrees. You can run an max of about 125 degree water supply to the floor to achieve this. If this is the only zone on the boiler you can just adjust the boiler supply temp and you won't need a mixing valve.

  • @jasonwoolverton9030
    @jasonwoolverton9030 Před 5 měsíci +1

    Does the backflow preventor on the feed valve need to be lead free? Mind divulging what model you use?

    • @JimSperanza
      @JimSperanza  Před 5 měsíci +1

      It does not. It's only for the boiler fill portion. I use a dual check.

  • @paulglendenning6409
    @paulglendenning6409 Před 9 měsíci

    what about a magnetic filter?

  • @gabakbusiness
    @gabakbusiness Před 5 měsíci +1

    i have a customer with one of those big boilers, do you have a video about how to replace it with one of those little ones like the one you have in the video?
    this a house from the 70's

    • @JimSperanza
      @JimSperanza  Před 5 měsíci

      Email me at speranzadevelopment@gmail.com

  • @iceripper6830
    @iceripper6830 Před 4 měsíci

    Do you have a video on the proper settings? I have installed 2 of these and both are using an abnormally high amount of gas. Your videos are extremely helpful but it would be nice to walk through the proper settings for the most efficient setup.

    • @JimSperanza
      @JimSperanza  Před 4 měsíci

      Email me at speranzadevelopment@gmail.com

  • @triantafyllosgkrekos1387
    @triantafyllosgkrekos1387 Před 4 měsíci +1

    I was wondering, can you hook multiple units at the same exhaust and air intake?

    • @joshuaseaton7002
      @joshuaseaton7002 Před 3 měsíci +1

      Yes, it's called a common vent system. It's in the manual.

  • @paulglendenning6409
    @paulglendenning6409 Před 9 měsíci +1

    i guess you are using the built in Navien water feed system as opposed to external?

  • @abacojack13
    @abacojack13 Před 6 měsíci +1

    what size copper did you use on this build, for the main manifolds and the pump supplys

    • @JimSperanza
      @JimSperanza  Před 6 měsíci

      A mix of 1.25, 1 and 3/4

    • @sergeyvasilyevjr2644
      @sergeyvasilyevjr2644 Před 6 měsíci

      @@JimSperanza what is the manifold adapters part numbers for the 1.25 press fitting? Thank you

  • @stuartbrock7586
    @stuartbrock7586 Před 7 měsíci +1

    What is a combi boiler? Haven't heard of that. Why have circulation pumps on each zone rather than valves?

    • @JimSperanza
      @JimSperanza  Před 7 měsíci

      A combi is a boiler that provides heating and domestic hot water from the same unit. I typically use pumps for each zone because they are close to the cost of a zone valve and if a pump goes down you don't lose every heating zone.

  • @BeeBombard
    @BeeBombard Před 8 měsíci +1

    Can you link the drill copper reamer please?

    • @JimSperanza
      @JimSperanza  Před 7 měsíci

      czcams.com/video/3JOUdapw0fo/video.htmlsi=XEEQh7X2XnQK6_mX

  • @NormJackman-pg5bt
    @NormJackman-pg5bt Před 7 měsíci +1

    Hi Jim, Can you give me a price to build in floor heat in my basement. Four loops of 135 feet with Domestic hot water

    • @JimSperanza
      @JimSperanza  Před 7 měsíci

      Email me at speranzadevelopment@gmail.com

  • @israelrosado2370
    @israelrosado2370 Před 2 měsíci

    Hi Jim where are you located

  • @steventhury8366
    @steventhury8366 Před 4 měsíci +1

    What state are you in? I was thinking of having you build a system.

    • @JimSperanza
      @JimSperanza  Před 4 měsíci

      Email me at speranzadevelopment@gmail.com with your info 👍

  • @robb7177
    @robb7177 Před 3 měsíci +1

    Shouldn’t used pt indoors either as it has a lot chemicals that you wouldn’t want mixing with indoor air . There used to be arsenic in old stuff .

    • @JimSperanza
      @JimSperanza  Před 3 měsíci

      I do not use pressure treated plywood ever for these builds.

  • @andrewmiller9207
    @andrewmiller9207 Před 25 dny +1

    I need one, how do I order it...

    • @JimSperanza
      @JimSperanza  Před 25 dny

      @@andrewmiller9207 email me at speranzadevelopment@gmail.com

  • @peaceWorker77
    @peaceWorker77 Před 4 měsíci +1

    Navien is very complicated to deal. I got error code 12 doesn't go away. I change many parts already.

    • @JimSperanza
      @JimSperanza  Před 4 měsíci

      You should have an hvac technician check it out and they can contact navien customer support if needed.

  • @michaelisakov1108
    @michaelisakov1108 Před 9 měsíci

    How can I contact you directly?

    • @JimSperanza
      @JimSperanza  Před 9 měsíci

      Speranzadevelopment@gmail.com send me an email with your number 👍

  • @AlfredoSabillon-ez6yj
    @AlfredoSabillon-ez6yj Před 8 měsíci +1

    How can I contact you

  • @MACEDONIAbitola
    @MACEDONIAbitola Před 5 měsíci +1

    I Watched the Whole 45 Minutes and I Didn’t Hear you say is this Gas or Electric ?

    • @JimSperanza
      @JimSperanza  Před 5 měsíci

      This is a gas or propane system. The video link below is about electric boiler systems.
      czcams.com/video/BW7HaQuk8IY/video.htmlsi=0HDJSzjPz0PBku88

    • @MACEDONIAbitola
      @MACEDONIAbitola Před 5 měsíci +1

      @@JimSperanza Thank You 🙏

  • @whyyoupissmeoff
    @whyyoupissmeoff Před 7 měsíci +5

    Basically this could be a 5 min video if you didn’t basically say the same thing 5 times basically

    • @TehArtfulDodger
      @TehArtfulDodger Před 7 měsíci +5

      Still good information, tho. Dont be a hater 😜

    • @leoluna4116
      @leoluna4116 Před měsícem +2

      Basically could be a 1 sentence comment if you didn’t repeat yourself. Basically

  • @agamer7121
    @agamer7121 Před 6 měsíci +1

    Brother you speak as fuck,just do it.