Harmonics in Electrical Power Distribution Systems

Sdílet
Vložit
  • čas přidán 29. 08. 2024

Komentáře • 29

  • @tleshovzhandos
    @tleshovzhandos Před 3 lety +1

    Really nice job, materials were expalined so deliberately
    .

  • @kevinkevv2807
    @kevinkevv2807 Před 2 lety +1

    Thank you very much for your lecture.
    Im studying electrical engineering and i have learned about harmonycs in my university only 1% of all this you explained. Better to study on the you tube rather to go in school !

    • @RickSancheeze
      @RickSancheeze Před 10 měsíci

      you need to study and learn on your own. don't rely to your professors mate.

  • @abhinavjain1947
    @abhinavjain1947 Před 5 lety +2

    Really well explained! Loved the information.

  • @Roberto-cg2gr
    @Roberto-cg2gr Před měsícem

    What happens to third harmonics if you use line to line voltage supply instead of line to neutral?

  • @Roberto-cg2gr
    @Roberto-cg2gr Před měsícem

    If single phase loads are connected line to line, where will third harmonics flow

  • @kakida8
    @kakida8 Před rokem

    great presentation

  • @jacobthompson2794
    @jacobthompson2794 Před 4 lety +1

    Thanks, very informative.

  • @bellyberto587
    @bellyberto587 Před 4 lety +1

    Can I get the file of the presentation? Thank you

  • @pradiptamaity9976
    @pradiptamaity9976 Před 2 lety +1

    Can I get the presentation

  • @rlabutis
    @rlabutis Před 3 lety

    These harmonics makes the power meter charge you more for electricity because of how the meter works. How can this be corrected?

  • @sohailjanjua123
    @sohailjanjua123 Před 3 lety

    Hi, I like your lecture

  • @birhaniemequanint4830
    @birhaniemequanint4830 Před 4 lety

    thank you loved person

  • @seanobrien2183
    @seanobrien2183 Před 5 lety

    Excellent

  • @trinidadubici7172
    @trinidadubici7172 Před 3 lety

    Very interesting

  • @shubhamshukla1278
    @shubhamshukla1278 Před 6 lety

    Sir greeting for da day, I know u are a busy man but I am asking is der any easy way to learn capability curve of a synchrons generator..... Plz reply ASAP

    • @JIMC-zi6bi
      @JIMC-zi6bi Před 6 lety

      The best source of information on and performance curves for synchronous generators is the data sheet from the manufacture of the generators themselves.

  • @chaseclary8215
    @chaseclary8215 Před 5 lety

    Good job

  • @LIM_Khuan
    @LIM_Khuan Před 7 měsíci

    good

  • @arjunlailas4908
    @arjunlailas4908 Před 2 lety

    shuduk item

  • @DansFlix
    @DansFlix Před 4 lety

    Nope. Not even close.

    • @joeschmidt6597
      @joeschmidt6597 Před 4 lety

      What you mean?

    • @DansFlix
      @DansFlix Před 4 lety

      @@joeschmidt6597 Which harmonics are created is not a function of the kind of circuit you are using. 6 pulse rectifier vs 18 pulse rectifiers don't create specific harmonics just because they are have a certain circuit topography. There are laws that determine which harmonics are created and it's based on the angle at which the incoming sine wave was at when it intercepted the non-linearity. Read my book, don't wait for the movie.

    • @englandrasmussen3111
      @englandrasmussen3111 Před 2 lety

      Tell me why I see 5th 7th and 11th harmonics on my supply with 6 pulse vfd loads than . 😂 gtfo here this info is spot on

    • @DanBullard
      @DanBullard Před 2 lety

      @@englandrasmussen3111 The PHASE ANGLE where the distortion impacts the input sine wave determines the "Harmonic Signature." It has nothing to do with anything else. Not only did I discover this, I came up with the formula that predicts why you get the 5th, the 7th and the 11th. The phase angle where the distortion hits the sine wave is what drives it. I found a mechanical website that showed a harmonic signature from a galled bearing and laughed my butt off as I read the idiotic excuses for this harmonic signature. I poked fun at them and got in trouble with the sys-admin for that site, so I made this video explaining how that works. czcams.com/video/17PtfpLDV44/video.html

  • @enconengineers6166
    @enconengineers6166 Před 3 lety

    QUOTE "Single largest cause of severe harmonic distortion is resonance" UNQUOTE. Not exactly so - though the harmonic resonance does cause some severe harmonic distortions. If one applies only Capacitor with a Non-Linear load, the capacitor would magnify harmonics and one would land into a severe harmonic situation. Save for that, it the extent of Non-Linear Loads and when the transformer operates near its full capacity (with high VFD drives etc.) that cause THE REAL AND THE SEVERE HARMONIC DISTORTIONS, both with the THDi (Total current Harmonic Distortion) and THDv (Total voltage Harmonic Distortion). Check out the myths vs facts. enconengineers.in/harmonic-filter-powerful-super-tuned-specification