Bad High Pressure Switch
Komentáře • 25
Další v pořadí
Automatické přehrávání
Trane Heat Pump with Bad HPS, Diagnosed! #hvac #airconditioner #heatingJeff’s HVAC Adventures
zhlédnutí 14K
AC Contactor Troubleshooting and ReplacementApartment Maintenance Pro
zhlédnutí 29K
HVAC 076 Pressure Switch RefrigerantLove2HVAC with Ty Branaman
zhlédnutí 41K
50 YouTubers Fight For $1,000,000MrBeast
zhlédnutí 197M
Attack a Terezka jdou na rande… KOUPALIŠTĚAttackShorts
zhlédnutí 300K
Dívka zkouší prokletou hru! #shorthorrorstories #shorthorrorstory #horrorshortsPrézovy noční můry
zhlédnutí 242K
PROČ JSOU KURÝRNÍ SLUŽBY UTRPENÍ 📯 💀MarleyKKT
zhlédnutí 298K
Testing Pressure Switches on Condensing UnitsTec Tube
zhlédnutí 104K
I WANT IT COLD! Charging 410A by superheat and subcoolingIron Shield Heating & Air
zhlédnutí 12K
Finding Low Voltage Shorts Fast! HVAC Troubleshooting!AC Service Tech LLC
zhlédnutí 436K
How HVAC Refrigerant Pressure Switches Work & Troubleshooting!AC Service Tech LLC
zhlédnutí 162K
The Danger of High Airflow in HVACHVAC Shop Talk
zhlédnutí 27K
AC Won't Start - How To Troubleshoot & Replace a Contactor - 1 Pole vs 2 PoleBenjamin Sahlstrom
zhlédnutí 609K
AC Contactor Not Pulling In - 10 Reasons WhyWord of Advice TV
zhlédnutí 837K
From Problem to Solution: HVAC Contactor Troubleshooting and ReplacementThe Home Improvement Channel
zhlédnutí 51K
Troubleshooting a Faulty Low Pressure Cutout on a Residential ACInterplay Learning Interactive Training
zhlédnutí 56K
Beautiful game!😍Boomerang Sportsbook
zhlédnutí 8M
Dokázal Jsem ToTaky Bige
zhlédnutí 141K
Little girl's dream of a giant teddy bear is about to come true #shortsFabiosa Animated
zhlédnutí 8M
Growing An Ear In Your Arm 😨Zack D. Films
zhlédnutí 62M
Jak Vypadají Noví Nejbohatší Youtubeři v Česku?Bige
zhlédnutí 397K
Useful gadget for styling hair 🤩💖 #gadgets #hairstyleFLIP FLOP Hacks
zhlédnutí 4,5M
BUCHINGER vs. LEV 🦁OKTAGON MMA
zhlédnutí 309K
Jumper wire left the chat.
Where is your gauges. You don’t just assume The switch is bad.
Absolutley
Got sent to a job where diff condomed high pressure cut out switches bc unit wasnt comingnon
system was flat ......
@@maxsilva5454how was the high pressure switch cutting unit off if system was flat?
Always use your gauges!! But I’m assuming he did already since well, he’s an HVAC technician lol but ya never know….
no gauges ? and you determine that an overcharged unit has a bad HPS ?
Good call 👍
If you have voltage going in but not coming out before the HPS are you sure the high pressure switch is bad and not just doing what its supposed to be doing?
High pressure switches are normally closed and when they do open they should close back once the pressure drops below the rating for that pressure switch. This pressure switch got stuck in the open position thus not letting low voltage go through it to the contactor.
@ramseyhvac I understand how it works. The point I was making is simply that just because voltage is coming in but not leaving the outgoing side of the board is rarely a case of a failed pressure switch. More often than not its something working correctly and protecting something, such as the compressor. Thank you for your quick response. I'm not here to troll. I'm like you. I see a problem and immediately think of the things it could be is all.
@@kennybakerhvacr5751 I hear what you’re saying. And after I replaced the pressure switch, I checked amps on the compressor, fan motor, pressures, SC, SH, Delta T. I also checked the outdoor coils and they where not that dirty. Thanks for the question. We are all trying to learn.
@@Davidandgoliathhvacthat is the way to check. Also sometimes you can tap on them to free up the switch temporarily until you get a new one
High pressure is working its the run cap or condenser fan motor what tripped it there is a reason where are your gauges
We’ve been seeing the Newer YORK residential heat pumps (2 or 3 years old)
with a shit load of faulty pressure switches
And yes you have to braze it in 😐
Thanks for sharing I’ll keep that in mind with the newer Yorks!
You'd be surprised how many people don't know you can by pass until you return for repair
Same with defrost boards 😂😂😂
Definitely dont bypass a lps that could end very badly
Turn unit on and condender fan motor is bad 😂
Hi. Did you make video for this repair?
YES, it is so obvious the pressure switch is bad!!!!
It couldn't be that the pressure switch, a safety device, is doing its job.
Can you say, "I am a hack"?
Check Continuity
Really-🤔-Interested
Is the switch open or close 🤔
Open power on not completing circuit obv