  • Most induction motors are controlled by the direct online starter, however, the heavy motor with the heavy load if there started using direct online starter Huge voltage surge(voltage surge can damage electronic equipment, small machines and the contractor that is supplying the same circuit)because of the high current that is drawn from the supply.
    Parts that make up the starter
    1) 3 Contactors (main contactor, star contactor and delta contactor)
    2) Auxiliary contact(with NC) for each contactor
    3) On delay timer
    4) Thermo overload relay
    5) Control breaker(double-pole)
    6) Push-button(2)(start and stop)
    Here is how the control works or clicks here electrecasolutions.com/unders...
    When the ON push button starts the circuit by energizing the star contactor(S) and the timer(T) at the same time. The star contactor(S) get energized through NC of the timer(T) through NC of the delta contactor(D).when star contactor(S) is engaged(energized) it closes its auxiliary contact NO through which the main contactor(M) get energized.
    The circuit will run for the set period of time normally (a few seconds) and timer (T) will open NC and closes NO through which delt contactor (D) get energized.
    NOT because the main contactor(M) is energized through the star contactor(S), we don’t want it(main contactor) to go off when the star contactor is disconnected, that’s why we make a parallel connection between star contact (Y AUX) and main contactor (M AUX2).
    STAR DELTA STARTER VIDEO • star delta starter con...
    TIMER VIDEO • How on delay and off d...
    FORWARD REVERSE WIRING DIAGRAM VIDEO • forward reverse switch...
    FORWARD REVERSE WIRING VIDEO • forward reverse motor ...
    CONTACTOR SELFHOLDING VIDEO • contactor self holding...
    contact me here
    electreca.workshop@gmail.com
    follow me on Twitter / davidssengendo
    like my Facebook page / electerca
    Visit my blog electrecasolutions.com/blog/
    Buy contactors here amzn.to/39iW0p2
    Push buttons amzn.to/3qN2DpN
    AI Digital Multimeter amzn.to/2R1Q2mp
    Disclaimer: ELECTRECA is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to www.amazon.com

Komentáře • 162

  • @berkotropia
    @berkotropia Před rokem +7

    You are very nice guy who explains simply and accurately. The problem is this industrial electrics that there are too many arrogant and bully engineers there who purposely confuse you and let you down. If I had more people like you, my studies could have been less painful. Thanks!

    • @electreca1
      @electreca1  Před rokem +1

      I appreciate the compliment and thanks for watching.

  • @umarsharif-g7y
    @umarsharif-g7y Před 10 dny +1

    you are very nice brother.very easy explain to understand us.thank you so much.

  • @seanakiiki7670
    @seanakiiki7670 Před 4 měsíci

    I really appreciate u, u have helped me as an electrician to understand more about automation industrial engineering,long live, god bless you, iwill let my son studying begin to follow ur lectures on line, thxu
    Best regards

  • @vee_entertainment
    @vee_entertainment Před rokem

    I love this channel now,I found it today and am really grateful🎉🎉good work mwalimu,came here after not understanding in class😅

  • @mathewsnyirenda4004
    @mathewsnyirenda4004 Před rokem

    Great works indeed. Am learning every day

  • @siamankangasam6414
    @siamankangasam6414 Před rokem

    You're a great engineer sir

  • @morgankpabitey1837
    @morgankpabitey1837 Před 3 lety +2

    Thank you so much. This is crystal clear.

  • @thabisodlamini41
    @thabisodlamini41 Před rokem +1

    Thanks Sir, today you made my day well presented video I did understand every single word you spoken

    • @electreca1
      @electreca1  Před rokem +1

      Glad to hear that and Thanks for watching

  • @samuelmainakamunye571

    good work and educative lesson

  • @tinashemuparangi2978
    @tinashemuparangi2978 Před 2 lety +5

    mr sir there is no reason to interlock the main contactor.
    the main and the star come in together at the same time. lets assume we are using pneumatic timer that means it should be coupled with the main contactor..maybe u can add a hold in for delta and disconnects the timer from the by adding normallt ope interlock for delta on timer circuit.

  • @ayodeleelijah3257
    @ayodeleelijah3257 Před rokem

    Thanks for the explanation 👍👍👍

  • @seanakiiki7670
    @seanakiiki7670 Před 4 měsíci

    I love u so much ur videos are good and well scientifically explained,

  • @lesliemaloba1825
    @lesliemaloba1825 Před rokem

    Great explanation indeed

  • @elibarickandrew4496
    @elibarickandrew4496 Před 8 měsíci +1

    Good explanation but you said in this circuit star contactor should energize first before main contactor. Qn why star first while the motor will not start if both main and star are not energized.

    • @johnkapauo2995
      @johnkapauo2995 Před 2 měsíci

      He just explain the logic here. If you see it properly, I think you'll see, the main idea here is the ADDRESS. The contact that the main rely on relies on the address of the star coil, so star has to come ON first followed by the main, bear in mind that that happens in short space of time (as he mentioned, by the blink of an eye), so if the motor relies on the main, then the motor won't start if star coil is OFF or not energized. This is the result of main not being energized, hence causes the motor to remain OFF.

  • @mohdfauzeerosslie7515

    ty my man. simple explainantion.

  • @ezekiellaini9530
    @ezekiellaini9530 Před rokem

    Well explained to the point 💪

  • @bisoborwaseaneilly7080

    So good sir am learning and enjoying thxu

  • @vincentowira6743
    @vincentowira6743 Před 2 lety +13

    Good job bro, but main and the star contactor comes in at the same time.

  • @oviaudhimbamatuyeeviyiwana2819

    Plus is the power being supplied through the main contactor or from where is the power coming from since on the main there is no where it's indicated as to where the power is coming from to the main contactor ?

  • @siamankangasam6414
    @siamankangasam6414 Před rokem

    Very lovely, you have made me go back to school

  • @bisoborwaseaneilly7080

    Sir ur very true and perfect thxu

  • @user-ok1sr6xd5p
    @user-ok1sr6xd5p Před 6 měsíci

    Great job sir❤

  • @sohailjanjua123
    @sohailjanjua123 Před rokem +1

    Hi , I like your video. Thanks

  • @IzoKey-iy9zq
    @IzoKey-iy9zq Před 2 měsíci

    Thanks your for the teaching

  • @kumning3331
    @kumning3331 Před 10 měsíci

    thanks, well presented

  • @erick2pac360
    @erick2pac360 Před rokem +1

    Uv made me clearer

  • @erick2pac360
    @erick2pac360 Před rokem +1

    Knowing starters and backups means that am done with automation??

  • @Prosper_Electrical.
    @Prosper_Electrical. Před 3 lety

    I follow you Everytime

  • @bezibedie4259
    @bezibedie4259 Před 11 měsíci

    How can you put an isolation switch in this wiring ?

  • @user-gt4wf8pv5k
    @user-gt4wf8pv5k Před rokem

    Good explanation

  • @LameckPhiri-ex9bj
    @LameckPhiri-ex9bj Před 10 měsíci

    Good job bro continue teaching us

  • @mwangijohn538
    @mwangijohn538 Před 3 lety +4

    Thanks David, during demonstration,u said this goes here , and that goes there, especially energizing the main contactor, there are terminal, there marked 13 ,22 and 14: and 21 so which one do mean inside nor out, please clarify by naming the terminal nos and either no or nc

  • @fredericokasper7854
    @fredericokasper7854 Před 2 lety

    Thanks!

  • @bonnymazhara1396
    @bonnymazhara1396 Před rokem

    Thanks engineer

  • @basilmasvikeni9931
    @basilmasvikeni9931 Před rokem

    Good stuff man

  • @viavictoreletrica3527
    @viavictoreletrica3527 Před 2 lety +1

    Excelente profissional

  • @okolceaser6056
    @okolceaser6056 Před rokem

    It's good on that circuit to protect the timer

  • @adventurendaba9020
    @adventurendaba9020 Před 2 lety

    thank you broe

  • @igwekelechifebian781
    @igwekelechifebian781 Před rokem

    I was really getting the mode of operation,but got confused about the illustration on main contact connection after the star disengage

  • @martin6934
    @martin6934 Před 8 měsíci

    How can someone solarize the induction motor especially the star delta ones?
    Which inverter?

  • @kindmanmundingi8588
    @kindmanmundingi8588 Před rokem

    What wil happen if a main contactor energised before the star and the star pulls in after?

  • @mohameddzugwe6813
    @mohameddzugwe6813 Před rokem

    Thank you

  • @leomichael3433
    @leomichael3433 Před rokem

    Good job thanks for this

  • @user-ox8zd3zk5g
    @user-ox8zd3zk5g Před 7 měsíci

    This is very nice

  • @prashanthsadam9048
    @prashanthsadam9048 Před 7 měsíci

    Hi
    what will be happening if main contact and star contact at a time start

  • @ongomsamuel2896
    @ongomsamuel2896 Před 2 lety

    Good Engineer

  • @mahmoudkamal8673
    @mahmoudkamal8673 Před 2 lety

    great keep going sir

  • @geoffreysakala8496
    @geoffreysakala8496 Před 2 měsíci

    Hi.... can i find a video on how to install a 3phase submersible pump

  • @abdulhamidmirzaee3097
    @abdulhamidmirzaee3097 Před 11 měsíci

    Hi. Thanks for the video. One question: Why the NO of the timer is needed before delta contactor. Delta contactor will energize without the timer NO being there.

    • @-1HUMANITY-
      @-1HUMANITY- Před 7 měsíci

      Can it gets energized without no

  • @JOFREYNgimba-pk5ur
    @JOFREYNgimba-pk5ur Před 9 měsíci

    You mean maincontactor Will consist Three auxiliary which is normal open?

  • @prashanthsadam9048
    @prashanthsadam9048 Před 7 měsíci

    In this star delta connection after few seconds circuit will change star to delta in this time main contact in on position here any happend?

  • @anthonydicksonojih5079

    Thanks very much

  • @umakanthbojanapalli3240

    Valuable information sir

    • @electreca1
      @electreca1  Před 2 lety +1

      Thanks and welcome

    • @umakanthbojanapalli3240
      @umakanthbojanapalli3240 Před 2 lety

      @@electreca1 plz send you complete panel wiring video's interlock manually auto motor protected and all 11&33&110&220&400&600 kV vcb power really wiring and ct pt box termination and drawing and small trans former design wire selection core selection bobbins selection and formulas releate charts PDF and every panel wiring PDF and substation commission and PLC and every thing electric part send videos

  • @jameschitala3753
    @jameschitala3753 Před 4 měsíci

    Very educative sir....thanks alot. I have a question: if the main contactor energizes last then, which contactor does the holding role?

  • @denofilms2438
    @denofilms2438 Před rokem

    Good job.. Iam requesting you do alarm bell sirens using relay for 8,12,14 pin.
    And using relay in controls more machines

    • @electreca1
      @electreca1  Před rokem

      OK will consider, thanks for watching

  • @josephnthungu
    @josephnthungu Před 2 lety

    Brother thank you for your video.But i have a qsn about the second Main auxilliary you have introduced down there.Can you just make a loop wire from Main auxilliary and bring down and bypass it,and connect at the second terminal of STAR AUXILLIARY BLOCK?

    • @electreca1
      @electreca1  Před 2 lety

      If you do that the Main contactor will engage before the Star, yet our primary goal is the Star to engage First

    • @josephnthungu
      @josephnthungu Před 2 lety

      Bro.now it's clear now after i followed your video and demonstration

  • @ebenvanstaden5364
    @ebenvanstaden5364 Před rokem

    How long are timer set before the Delta get enrgized which are going to be brought in by the timer coil...because the minute you leave the start button ,the circuit will be de-energized,start wont be retained because the main contactor dont have power yet ....meaning the entire circuit will fall out again...star en timer

  • @edwardpamedwardpam8843

    Nice one

  • @user-jf9pv5us3x
    @user-jf9pv5us3x Před měsícem

    Can you tell how it switches from high voltage to low?

  • @ishackbugum8179
    @ishackbugum8179 Před 5 měsíci

    What is the purpose of the star Auxiliary contact on the main contactor sir

  • @MutenderiYafesi
    @MutenderiYafesi Před 3 měsíci

    Good work papa

  • @user-bp6hh4re2g
    @user-bp6hh4re2g Před rokem

    Can you pls show me how do star delta foward reverse with four magnetic Contactor and one timmer

  • @mahamudabdullahi7506
    @mahamudabdullahi7506 Před 3 lety

    You explained very well come up with practical. and I request you to repeat on forward and reverse especially on the indicators that is my big problem

  • @binnasser-rj5id
    @binnasser-rj5id Před rokem

    Bro! My question is when push button pressed the phase will pass to Timer and start to count as as main contact make the also pass to normal close of timer and pass to Auxiliary contact of delta contact then to A1 of start contact, I'm confused to this Auxiliary contact which will put above the contact start since we use the NC aux when pass phase make and become open while holded to cont start why still make because NO means phase will blocked via to star contact ???

  • @oviaudhimbamatuyeeviyiwana2819

    Why do we need the main contactor in our circuit. Is the circuit not gonna work if removed?

    • @electreca1
      @electreca1  Před 2 lety

      The main contactor help to hold the circuit that's why we use push button to make the circuit more safe to operate and reliable, if you remove main contactor then you have to use a switch(not push button) which will keep the timer permanently on during operation.
      As long as the timer is on, circuit will remain running.

  • @ericmassamaki2498
    @ericmassamaki2498 Před 2 měsíci

    it's better you could write the tarminal number of those devices so that some of us could be easy to know after what goes to number what thank you.

  • @mbuthianjoroge9434
    @mbuthianjoroge9434 Před 3 lety

    Kazi nzuri boss

  • @bonnylasu7665
    @bonnylasu7665 Před rokem

    Sir very interesting but can you change your colour of marker? Your writing not clear for star, delta wiring

  • @oyenaraymond6520
    @oyenaraymond6520 Před rokem

    My question is star Auxiliary is closed or open? that's what am not getting....in the explanation u Said it's closed but in the diagram it's open so.....

  • @user-ox8zd3zk5g
    @user-ox8zd3zk5g Před 7 měsíci

    Kindly am asking if you can assist me with the traffic light circuit diagram

  • @nkosinathimnisi5990
    @nkosinathimnisi5990 Před 2 lety

    We have circuits that put in the main and star at the same time is it wrong ? If yes tell me why?

    • @ongomsamuel2896
      @ongomsamuel2896 Před 2 lety

      Do you deal with only 33kv or even the single phase

  • @FowziaMohamud-pi5fh
    @FowziaMohamud-pi5fh Před 8 měsíci

    Eng.what is the diffrence between delta connection and dol

  • @linossinkala7840
    @linossinkala7840 Před 3 lety

    Super

  • @piusngibeyo5161
    @piusngibeyo5161 Před 3 lety

    We are approaching amillion subscribers, bro thanks for your videos that are educating am from turkana county

    • @electreca1
      @electreca1  Před 3 lety

      Thanks so much Pius....by the grace of God and hard work we will hit a million

    • @nkailefrance665
      @nkailefrance665 Před 2 lety

      Please add yu number sir if we need any assistance we will contact you.......or we can great group....

  • @muradzeynal
    @muradzeynal Před 2 lety

    sir, why did you use that H switch, i couldn't quite catch that. My point is that if there is main auxiliary, what is the reason for using H switch?

    • @jmajuta2963
      @jmajuta2963 Před 2 lety

      The H aux is to hold the timer and the m contact is to hold the main contactor

  • @sahiln3d514
    @sahiln3d514 Před 3 lety

    Good work , congrats.. But sorry we need pratical if possible . God help you

    • @electreca1
      @electreca1  Před 3 lety

      I did a practical video for this topic, however, some viewers requested more clarification on the circuit diagram.................. here is the practical video czcams.com/video/we7MxJ0fjDM/video.html
      Thanks for watching.

  • @odonggeorgerackara4885
    @odonggeorgerackara4885 Před 8 měsíci

    Does it also apply to transformers

  • @Ngobisamuel-rh9sw
    @Ngobisamuel-rh9sw Před 3 měsíci

    Bro , I request u to take us through motor winding

  • @konnehzinnah3124
    @konnehzinnah3124 Před rokem +1

    Thanks brother for the video. It's good.
    Point of injection:
    Use the main contactor NO across the start pb switch so it serves as the master switch; It will stop entire control network if the Stop Pb switch is pressed. The main contactor should work with both the star and delta contactor. The main contactor should control the timer coil from the action of its NO Auxiliary contact.
    It's the timer's duty to switch between the Star and Delta contactors with its NC and NO contacts respectively with the set time.

  • @GeovaniYakubu
    @GeovaniYakubu Před 2 měsíci

    That's good

  • @konithierry9475
    @konithierry9475 Před rokem

    Good job bro please my question is how can you wire it involving emergency push button

    • @electreca1
      @electreca1  Před rokem

      you can wire you Emagency buuton circuit beaker and Overload relay. thanks for watching

  • @praisepola3886
    @praisepola3886 Před rokem

    so a star and a mean work like a duble mcb

  • @learnwithemmy123
    @learnwithemmy123 Před 3 lety

    Very good content. Keep the good work.

  • @nevermajola4402
    @nevermajola4402 Před 2 lety +2

    Remove normal open on the main that can make your circuit simple main and star can start together you just confused lot of people but pose uncessary normal open on Main

  • @leonardchinonso7067
    @leonardchinonso7067 Před rokem

    Pls. Can you do a video on electric motor rewinding

  • @bobojanespaner9761
    @bobojanespaner9761 Před 3 lety

    please add temperature sensors on your circuits as well as use of vfds

  • @chidiemelobe1044
    @chidiemelobe1044 Před 2 lety +1

    Good. But I think it will be nice if the timer coil can be de-energize after switching to delta

    • @electreca1
      @electreca1  Před 2 lety +2

      The timer I used it Normally closed, so it has to be and remain energised to hold the Delta contactor on. If the timer coil de-energise then delta will lose power.
      What do you think?

  • @abednigojustin3508
    @abednigojustin3508 Před měsícem +2

    Great job brother....but just a suggestion...why not use the auxiliary contact (NO) of the delta contactor to keep the main contactor energised when the star connection time elapses..... because using the auxiliary contact of the main contactor mean when the start push button is pressed the main contact also start immediately....

  • @okolceaser6056
    @okolceaser6056 Před rokem

    Timer protection these days is recommended coz the timers in market are week ,let the timer be switched from NC delta and on the timer switch NO put a hold cct from no delta

    • @okolceaser6056
      @okolceaser6056 Před rokem

      Put NC for delta to switch timer ,then put hold on contact on timer NO to switch delta this will help timer to be always off when motor is running on delta contact

  • @sseguyazakiyu4112
    @sseguyazakiyu4112 Před rokem

    Hlo sir thx

  • @johntamrang9139
    @johntamrang9139 Před 7 měsíci

    hello David. can you pls do a video on how to connect a 3phase ats signal cable to amf25 pls

    • @electreca1
      @electreca1  Před 6 měsíci +1

      Will plan, thanks for watching

  • @zakariaabdi2316
    @zakariaabdi2316 Před 3 lety

    Teacher thanks for video 🙏....but sir if possible I need circuit connection please

    • @electreca1
      @electreca1  Před 3 lety

      That circuit i drew on the board is CONTROL CIRCUIT for star delta stater, unless you need a power circuit. you can find it here electrecasolutions.com/understanding-star-delta-starter/

    • @zakariaabdi2316
      @zakariaabdi2316 Před 3 lety

      Thanks Teacher

    • @ongomsamuel2896
      @ongomsamuel2896 Před 2 lety

      They gave us please but he can do it again

  • @sahilnawab894
    @sahilnawab894 Před 2 lety

    Thankyou sir 🙏😊😌

  • @user-uo1fr4sm1i
    @user-uo1fr4sm1i Před rokem

    which of the connection is that'

  • @najibdanduni2373
    @najibdanduni2373 Před 2 lety

    Hi sir i have some project i want to discuss with you. If u dont mind give me your contact thank u

  • @fredngoma1657
    @fredngoma1657 Před 3 lety

    What's the purpose of the timer???

    • @electreca1
      @electreca1  Před 3 lety

      The function of the timer is Delay.
      Example, if a generator starts, the timer will delay until attain its full speed(RPM) then the timer can load the generator.

  • @mianmudassar2365
    @mianmudassar2365 Před rokem

    Sir Urdu translation bi kar dia karain

  • @sammynyadero7495
    @sammynyadero7495 Před rokem

    How do we connect a timer without coil

    • @electreca1
      @electreca1  Před rokem

      What kind of timer is that?, timers wether digital or analog have got a coil.
      Thanks for watching.

    • @sammynyadero7495
      @sammynyadero7495 Před rokem

      @@electreca1 Thank you for your response. The timer has only NO and NC

  • @prospermuvadi589
    @prospermuvadi589 Před rokem

    now l have picture

  • @mbangupaules5972
    @mbangupaules5972 Před 2 lety

    Where is the CB in your circuit

    • @electreca1
      @electreca1  Před 2 lety

      My bad! I did not indicate it, but it should definitely be included the circuit.