Agni fire Alarm Panel (Working and installation) by Green Tech Solutions | Agni Smoke Detector
Vložit
- čas přidán 8. 09. 2024
- Here is the detail Working and Installation of the fire alarm system with smoke detector, MCP, Hooter, Fire Accessories etc
Agni Devices 2 Zone Fire Alarm Panel Pack of 2
amzn.to/3cVZGNT
Buy CCTV Kit
*********HIKVISION ECO kit**********
Hikvision 4 ch Eco Combo kit with 4 Camera with all required accessories
amzn.to/3ywVPSf
Hikvision 8ch Eco Combo kit with 6 Dom and 2 Bullet Camera with all required accessories
amzn.to/3E0Q5kA
Hikvision 16ch Eco Combo kit with 16 Camera with all required accessories
amzn.to/3yDLKTG
***********Hikvision 5MP Kit*********
5MP Combo Kit Hikvision
HIKVISION 8ch 4K UHD 5MP with 8 Security Camera Kit, White
amzn.to/3dTwA2X
HIKVISION 4CH 4K UHD 5MP with 4 Security Camera
amzn.to/3E0qRmv
***********CPPLUS 2MP KIT***********
Cpplus 4ch 5mp Combo kit with 4 Camera with all required accessories
amzn.to/3dW3obz
Cpplus 8ch 5MP Combo kit with 4 Bullet and 4 Dom Camera with all required accessories
amzn.to/3DXXEIX
CPPLUS 16ch 2 MP Combo kit with 16 Camera with all required accessories
amzn.to/3dUDN2C
*********Dahua 5MP kit**********
Dahua 4 ch 5mp Combo kit with 4 Camera with all required accessories
amzn.to/3p13BAQ
Dahua 8ch 5MP Combo kit with 6 Bullet and 2 Dom Camera with all required accessories
amzn.to/321yjRt
Dahua 16ch 5MP Combo kit with 16 Camera with all required accessories
amzn.to/33A50WE
Hi
I Am Manoj Sharma. Welcome to Our CZcams Channel Green Tech Solutions.
Our some other playlist -
Point to point Setup for IP camera
• Point to point Setup f...
CCTV ON FIBER OPTIC CABLE
• CCTV ON FIBER OPTIC CABLE
Wifi camera setup
• wifi camera setup
PTZ Camera Setup
• PTZ Camera
Biometric Attendance System
• Biometric Attendance S...
Social Media Links
Facebook : / green-tech-solutions-6...
Instagram : / green_tech_solutions
Twitter : / manu2s
For Advertising / Sponsorship or any other business related enquiries you can contact me via my mail id.
greentechkkr@gmail.com
I hope this video was Useful and you liked it, if you did press the thumbs up button.
[ THANKS FOR WATCHING THIS VIDEO ]
#agnifirealarmpanelmanual
#destinymanu
#greentechsolutions
#Firealarmpanel
Thanx sir
Boht hi helpful hai ye video hamare liye
Keep it up and go ahead
Thanks for appreciation!
Good teaching
Bahot badhiya sir aapka latest video Fiber wala IP camera specially bahot badhiya aur latest ❤️
Thanks sir
I'm appreciate 🙏this video.. For help how to installation🔥 fire alarm system...
Awesome you and your video
Sand pedro city of laguna
Hi
Very well explained
Our Agni Fire alarm panel shows zone 2 short
What does it mean
There are two detectors in it. One of the detector is not blinking
Detector wire is short
Plz change Detector and check
Nice brother
Nice
Tnks sir
Sir hi call point 3 zone ke 3 laga sakte kya wahi floor pe
Hanji you can use mcp in every zone
Super
What is benefit of this product ???
Gives alarm when smoke start
Prevent from fire
How to function short circuit marine isolator (55000-721 MAR)
Please do an English version
Yes I will
Thanks
Raval somok didctar ka chanisan kese karte he aur system sensor aur apollo ka karte he sir je please reply searching
Let me check bhai
How could we know + or - in smock sensor
It is always written on detector and also on user manual
Hi
Mene Ye Job Kari He me ish job ko kar sakta hu agar karni he to batana
System sensor beam ditecktar canetion ka bare me boliye
Ok sir
Alarm panal band karane la tarika bataye sir jisase jisase thodi de ke liye kar sake
Press silence button on keypad
It will stop for some time
Sir mai Fire Alarm Installation Work karta hu, Installation Work Ho to bataye
Ok sir
Vai sres nhi kya prelalme connect kya
?
Where we can buy ,pls provide link
You can buy it on Amazon or Flipkart
Or you can directly go to Agni devices website
Agni smoke detector cannectoin and ri bhi
Fire alarm panel isolate seh heldi me k se rakte he
Did not understand your question
well discribed
1 zoon available hai kya
Bhai
Agni fire alarm panal a akta problam hocha display ta FIRE ALARM আসছে kintu kono address দিচ্ছে না are field a kono smoke nai tahola ki korbo
Bhai agar muje ye Kam suru karna ho to apne area me kya karna hoga
Aapke area main jo installer hoga unke pass kuch time ke liya kaam sikh lo then you can start
@@GreenTechSolutions okay sir aap ka kon sa area h
@@kumarbhupender6820 kurukshetra haryana
@@GreenTechSolutions aap ka no. Mil Sakta h kya
Why we are using resistance in last of zone
To complete the circuit
Only than it works proper.
If u are not contact the resistance so panel show open circuit .....
To complete the circuit ...resistor allow to flow the little amount of current and FACP read that current flow for confirmation that circuit is completed all devices are connected
In FACP fixed limits of current flow for different type monitoring
For example no current flow means circuit open low current flow means system normal
High current flow means alarm
Very high current flow means short circuit
Hiu
Hii DESTINY MANU this is nadeem from new delhi can i get proper traning of all types fire alarm panel please let me know thanks....
Yes sir you can
@@GreenTechSolutions sir what's the process to get the training....plz explain
There are many institute in Delhi which provide crash course for fire alarm panels and gives all technical details about it.
@@GreenTechSolutions sir, tell us some best institute in delhi..
I am working as fire alarm technician in Saudi arabia at king Abdullah university for science and technology here we take care system like simplex, est3, autrosafe , vesda , etc I can share you what I learned +966559872853
sar panel ma kasa koneshon kartahi thankyou
Series connection
Class B
What is loop card?
Loop card use in addressable fire alarm system
This is conventional alarm system
Loop is basically signal line in which many addressable detectors are connected
Thanks for your reply
Bhai fire alarm system me technician se interview me kya puchhta h any tips
For Installation purpose
He should know the series connection and also know about 12/24 volt system
I want to talk with you but how😢??
Basic sawal puchte hain
Q:- Fire alarm system kitne type ke hote hain?
Ans - conventional, addressable, intelligent, wireless
Q -: conventional aur addressable me kya fark hota hai ?
Ans - conventional system me sirf zone ka pata chalta hai ki kis zone me detect hua hai fire. Exactly pata nahi chalta ki kis office kis room me ya kaun se area me fire hua ye chote office ya ghar ke liye use karte hain jahan kam area ho to asani se pata chal jayega
Addressable system me exact LOCATION ka pata chal jata hai kis room ya area se trigger hua hai
Q - fire alarm system me kitni tarah ki wiring hoti hai
Ans. 2 type. Class A. Class B
Class A me wiring PANEL se nikal kar sare device connect hone ke bad wapas PANEL me aa kar connect hota hai
Class B me PANEL se nikal kar last device par EOLR end of line resistor laga ke band ho jata hai
Control module. Aur monitor module ka use kis liye aur kahan kahan hota hai ?
Control module ka use kisi dusre system ko fire alarm system se integration ke liye hota hai. Jaise ki AHU , FANS , elevator, glass doors , access control, barrier etc. In system ko fire case me on ya off ya bypass karne ke liye CM ka use hota hai. Aur horn strobe ya NAC circuit active karne ke liye bhi hota hai
Monitor module ka use kisi aur system ko FACP me duara monitor karne ke liye hota hai. Jaise preaction system, fm200 or novec , vesda , flow switch , tamper switch , zone control valve etc
1 zone me kitne Detector Laga Sakte Hai....?
12 detectors
NC = Normally close
NO = Normally open
159 take
Ncp ku kis sa connect kya ha
MCP ko aap zone ke end main connect karo after detectors
Hello Manu, we want to give smc of fire alarm Frylaast Agni. Reply is you interested.
What is SMC ?
9359018732
How much price of this unit ?
12000 Approx
Shall I get this job
Yes you can
Just take a knowledge for fire system etc
And there are many companies who offer for the fire safety specialist
Thank you
I want to talk with you but how😢??
Bhai 1 zoon ka panel hai kya
Minimum 2 zone
Aur mehnat kr beta tuze our bhi sikhna padega😄😄
Hanji sir, Thanks
MCP pe no reset ka switch hai
Us se fire panel ko reset hota hai kay
Konsi company ka fire Alarm Panel h
Language problem
Sorry for that
But its not an end
You have opportunity to learn sir.
Fire panel
Bhai minimum 2 zone ka aata hai
Job dila do sar please
Telugu lo chappu sae
Mai qya puch rha hun aur tu qya bta rha h ?
Made !
Bhai sahab kahna kya chahte ho ??
Conventional hai
Yes
@@GreenTechSolutions SIR WILL YOU UPLOAD ADDRESSABLE
Yes I will
@@GreenTechSolutions thank you which company
Morley/ceasefire
Teri bat bilkul smjh ni aayi re.
Bhai kya nahi smjh aaya
Hey, we have gone through your product (Fire Alarm System). Our company is interested in your product. Can we have a Formal discussion. Please revert me back.
Thank you.
Yes sir
9354444290
Hii sir this is uday here we are also fire alarm panel provider so shall we speak once my number 6362459535 please call me once .
bad presentation
Nice