How to do TAP or T and protrusion bifurcation stenting technique
Vložit
- čas přidán 5. 05. 2020
- TAP techinque made simple step by step
Six steps:
1. Wire both branches and dilate simultaneously or separately with balloons
2. Stent main branch and remove the side branch wire
3. Keep the stent ballon in its place and with a second wire cross the main branch stent into the side branch
4. Place a stent in the side branch with stent balloon of the main branch helping the nail the side branch ostium
5. Pull the side branch stent balloon back and perform kissing balloon inflation
6. Perform POT (with larger balloon on the main branch or side branch wire) of the proximal main branch stent
Thank you very much very useful
So nice of you
Very good presentation
Thanks
Thank you for your kind words
explained very well thank u
Thank you for your kind words
please make a video on septal puncture techniques or whole bmv procedure
Crushing not needed for TAP stenting?
YOu can crush sequentially. I think you mean kissing? yes kissing balloon inflation is needed. My practice has evolved since the video. I now perform balloon inflation on the side branch, then on the main branch and then kissing balloon inflation by inflating both balloons in TAP. This helps with less overhang of the stent. You do it when both balloons are already in kissing position. Not separately.