  • In this video, I will try to explain how to make 3 phase water pump DOL starter auto and manual connection using float switch, start and stop switches. And also I will explain this starter connection using circuit diagram.
    If you have any questions, please comment below the video. I will answer your questions.
    Thanks for watching this video.
    PLEASE SUBSCRIBE THIS CHANNEL FOR MORE VIDEOS.
    czcams.com/channels/TNu.html...
    💻Connect with SL Engineering Academy
    🌐Facebook 📲 / sl-engineering. .
    More video
    Complete Electrical House Wiring / Single Phase Full House Wiring Diagram /- Part 1
    • Complete Electrical Ho...
    Complete Electrical House Wiring - Part 2
    • Complete Electrical Ho...
    Complete House Wiring with Inverter Connection/ How to Select Inverter & Battery Capacity/ Explained
    • Complete House Wiring ...
    Float Switch Wiring Diagram for Water Pump/ How to Make Automatic On-Off Switch for Water Pump
    • Float Switch Wiring Di...
    1 Gang & 2 Gang, 1 Way Switch Connection / How to Wire One Gang & Two Gang Light Switch / Explained
    • 1 Gang & 2 Gang, 1 Way...
    3 Gang & 4 Gang Switch Connection / How to Wire Three Gang & Four Gang Light Switches / Explained
    • 3 Gang & 4 Gang Switch...
    Automatic Changeover Switch for Generator / Automatic Transfer Switch / ATS (With Circuit Diagram)
    • Automatic Changeover S...
    Bathroom Wiring Diagram / How to Wire a Bathroom
    • Bathroom Wiring Diagra...
    Intermediate Switch Connection / 3 way, 4 way, 5 way,...Switch Wiring Explained with Circuit Diagram
    • Intermediate Switch Co...
    Float Switch Connection with Auto & Manual Selector Switch for Single Phase Water Pump
    • Float Switch Connectio...
    Door Bell Wiring Connection-3 Methods /How To Do Calling Bell Wiring /Explained With Circuit Diagram
    • Door Bell Wiring Conne...
    DOL Starter Connection with Indicator | 3 Phase Direct On Line Starter/ Explain with Circuit Diagram
    • DOL Starter Connection...
    Single Phase House Wiring Diagram / Single Phase DB Wiring
    • Single Phase House Wir...
    How to Wire Ceiling Fan and Fan Regulator / Ceiling Fan Connection / Fan Regulator Connection
    • How to Wire Ceiling Fa...
    3 Phase Distribution Board Layout and Wiring Diagram
    • 3 Phase Distribution B...
    Earth Leakage Relay - ELR / How to Wire ELR & CBCT with MCCB / Working Principle of ELR
    • Earth Leakage Relay - ...
    Two Way Switch Connection / How to Wire 2 Way Light Switch / Starecase Wiring with 2 Way Switch
    • Two Way Switch Connect...
    Star Delta Starter for 3 Phase Induction Motor / Star Delta Connection
    • Star Delta Starter for...
    Single Phase Split Type Air Conditioner(AC) Indoor & Outdoor Wiring Diagram/ How to Wire Split AC
    • Single Phase Split Typ...
    Fluorescent Tube Light wiring connection/ Using Electrical Choke and Starter/ Using Electronic Choke
    • Fluorescent Tube Light...

Komentáře • 60

  • @user-fy6mv3jf9x
    @user-fy6mv3jf9x Před měsícem +1

    Indonesia 👍👍👍👍👍👍👍👍👍

  • @senthilvel4729
    @senthilvel4729 Před 5 měsíci +2

    Super explanation thanks

  • @justinneedham1423
    @justinneedham1423 Před rokem +2

    Thank you. It took me a couple of hours to track down a schematic of AUTO wiring for 3 phase DOL. One single image in your vid super useful, at 4:36. Sorry I didn't have the time to spend watching the diagrams being drawn.

  • @peterjesus816
    @peterjesus816 Před 2 lety +1

    Thanks a lot may God bless you

  • @jorgegranda3267
    @jorgegranda3267 Před 3 lety

    Bien predicado

  • @ulisescruz157
    @ulisescruz157 Před 3 lety +4

    I recently discovered your channel and let me tell you it's great, I'm learning a lot, excellent content, many congratulations, greetings from Mexico.

  • @anuruddhalogin
    @anuruddhalogin Před 3 lety

    Thanks !

  • @malakibad5614
    @malakibad5614 Před 3 lety

    So good sir g

  • @saikishorbajaj8587
    @saikishorbajaj8587 Před 3 lety +1

    Very good, useful information Thanks 👍🎉🙏🙏

  • @manpreetkumar1135
    @manpreetkumar1135 Před 5 měsíci

    Thank you.

  • @iyyappangopal704
    @iyyappangopal704 Před 2 lety

    Thanks sir

  • @awaazmatroko5972
    @awaazmatroko5972 Před 2 lety

    You have nice videos, want the above for 3phase 5hp water pump but with additional 1). waterlevel and programmable timer to switch after 12 - 20mins 2) thermal overload,
    3). Phase failure
    4). High/ low voltage

  • @nashirhussain5410
    @nashirhussain5410 Před 3 dny

    Nice

  • @JB_Onn
    @JB_Onn Před rokem

    Informative ❤

  • @AnasAl-Dhafiri
    @AnasAl-Dhafiri Před 3 lety

    Thank you

  • @rkprasadbhookya1878
    @rkprasadbhookya1878 Před 3 lety

    Superb

  • @SLfamily1
    @SLfamily1 Před 3 lety

    I m ur student. Sirak from nerway .

  • @boopeshkumarprabhakaran
    @boopeshkumarprabhakaran Před 3 lety +1

    thank you..please also make 3 phase connection for invertor

  • @danielshpendi6595
    @danielshpendi6595 Před 3 lety

    EXACT

  • @hetasarvaiya6443
    @hetasarvaiya6443 Před 3 měsíci +1

    3 pole mcb magnet contractor thermal overload relay yellow red blue black start on stop off trip auto float switch manual off teacher ji

  • @gaffarholla3608
    @gaffarholla3608 Před rokem

    I need to talk to you please because you are doing a great job

  • @baotranngoc9450
    @baotranngoc9450 Před 2 lety

    Thanks so much! Excellent

    • @slengineeringacademy2234
      @slengineeringacademy2234  Před 2 lety +1

      ❤👍❤

    • @juanpanguinao6657
      @juanpanguinao6657 Před 2 lety

      @@slengineeringacademy2234 hola que tal, saludos desde Argentina, en el circuito de control, ¿No tiene un interruptor aparte independiente del circuito de fuerza?

  • @brianmccollum2414
    @brianmccollum2414 Před rokem +1

    Is there a way to connect a second float switch? I need a high and low level (about 40" height difference, so 1 float won't cover) and know how to do the maintaining circuit for a single phase pump, but need to use a 3 phase for the current system.

  • @rpeonruzzel1294
    @rpeonruzzel1294 Před 2 lety +1

    I have a 10 hp, 3phase aircompressor motor the voltage needed is 400, I have a reading on line to line voltage of 225. So based on the video I can install it to a line a, b and c?

  • @hetasarvaiya6443
    @hetasarvaiya6443 Před 3 měsíci +1

    Emergency switch teacher ji

  • @user-ft9hb2vp9i
    @user-ft9hb2vp9i Před rokem +1

    سلام فلوتر چطور میشه روی مدار ستاره مثلث بست

  • @tecnoservicessecurity8517

    Good afternoon which program you use to animate your classes, because I need to give classes to my students.

  • @user-fy6mv3jf9x
    @user-fy6mv3jf9x Před měsícem

    👍👍👍👍👍👍👍👍👍👍👍

  • @seyedmojtaba1839
    @seyedmojtaba1839 Před 8 měsíci +1

    Salam very good

  • @vishwanathgulbarga708
    @vishwanathgulbarga708 Před rokem +1

    Separate diagram Draw control and power diagram in a page

  • @melchoraquino351
    @melchoraquino351 Před 2 lety +1

    Why do you need start, stop, emergency push button switches when the HOA switch will do the job safely?

  • @boopeshkumarprabhakaran
    @boopeshkumarprabhakaran Před 3 lety +2

    have a question.. as you mentioned above is the float swtich connected to direct current???? if soo.its not safe right..? could you please explain thank you

    • @manumamu100
      @manumamu100 Před 3 lety +1

      Same question. Which current will go to and comeback from float switch in this setup d.c or a.c?

    • @tharakamadusanka8638
      @tharakamadusanka8638 Před 3 lety

      @@manumamu100 AC current

  • @user-pl6bt9wg3v
    @user-pl6bt9wg3v Před 2 měsíci +1

    Pura course kese sikhe sir

  • @yasinmalik3085
    @yasinmalik3085 Před 3 lety

    Sir single phase submersible motor ko float switch se automatically on/off kara sakte hai.
    Like, Jab tank mai pani khali ho to motor Start ho jaye or jab tank Mai pani full jo jaye to motor stop ho jaye agar ye submersible motor ke liye possible hai to please ek video banaye.
    Thanks

  • @kumarelek6548
    @kumarelek6548 Před 3 lety +1

    Star delta starter pls

  • @elect874
    @elect874 Před 2 lety +1

    Plese provide in put line 30ma rccb

  • @afrog3569
    @afrog3569 Před 2 lety +1

    Hi. Does This exist in a panel

  • @akshaybhai1270
    @akshaybhai1270 Před rokem +1

    How does trip light work?

  • @ramborums
    @ramborums Před 2 lety +2

    Why is the red line connection required from the NO of float switch?

  • @user-qt8fh9rw3y
    @user-qt8fh9rw3y Před 3 lety +1

    Please tell me the application you are working on

  • @sazzad6116
    @sazzad6116 Před rokem +1

    Ata ki submarcbile pump a babohar kora jabe

  • @carristondennis8951
    @carristondennis8951 Před 5 měsíci

    what am i misssing if float switches dont switch the circuit on and off?

  • @raniemendozalaurona8526
    @raniemendozalaurona8526 Před 3 lety +1

    Can you help me see the actual diagram?

  • @sweettooit
    @sweettooit Před 2 lety +1

    the green indicator light will not work in this design when you keep manual mode.

    • @slengineeringacademy2234
      @slengineeringacademy2234  Před 2 lety

      Thanks for watching ❤👍
      No. It will work. Please watch the circuit diagram. It will be easy to understand.

    • @sweettooit
      @sweettooit Před 2 lety

      @@slengineeringacademy2234 right 👍

  • @lobsahaddin9269
    @lobsahaddin9269 Před 2 lety +1

    very bad' no any explanation should be teach 1 by 1 were u put the wire

  • @mariabenabdelouhab1453
    @mariabenabdelouhab1453 Před 3 lety +1

    Thank you