TRANSFORMER DESIGN CALCULATION IN TAMIL | AMPLIFIER| UPS| டிரான்ஸ்பார்மர் தமிழ்
Vložit
- čas přidán 20. 07. 2024
- Welcome To NURA TECH TAMIL
In this chapter we see about the any type of Transformer design basics and practically how to make a transformer too.
If we want to design the specific rated transformers neither buy from shop, for upgrade our Amplifier, UPS or other equipment i hope this tutorial may useful little bit.
Please ask any questiins in the comment box. With best of my knowledge i shall try to explain.
Thank You
THE STANDARD CORE SIZE AVAILABLE IN MARKET.
Type No-------------------Tongue Width----------Winding Area-
17(E/I)--------------------1.270------------1.213
12A(E/12I)---------------1.588-----------1.897
74(E/I)--------------------1.748-----------2.284
23(E/I)--------------------1.905-----------2.723
30(E/I)--------------------2.000-----------3.000
21(E/I)--------------------1.588-----------3.329
31(E/I)--------------------2.223-----------3.703
10(E/I)--------------------1.588-----------4.439
15(E/I)-------------------2.540-----------4.839
33(E/I)--------------------2.800----------5.880
1(E/I)----------------------2.461----------6.555
14(E/I)--------------------2.540----------6.555
11(E/I)---------------------1.905---------7.259
34(U/T)--------------------1/588---------7.259
3(E/I)-----------------------3.175---------7.562
9(U/T)----------------------2.223----------7.865
9A(U/T)----------------------2.223----------7.865
11A(E/I)-----------------------1.905-----------9.072
4A(E/I)-----------------------3.335-----------10.284
2(E/I)-----------------------1.905-----------10.891
16(E/I)---------------------3.810-----------10.891
5(E/I)----------------------3.810-----------12.704
4AX(U/T) ----------------2.383-----------13.039
13(E/I)--------------------3.175-----------14.117
75(U/T)-------------------2.540-----------15.324
4(E/I)----------------------2.540----------15.865
7(E/I)----------------------5.080-----------18.969
6(E/I)----------------------3.810----------19.356
35A(U/T)-----------------3.810----------39.316
8(E/I)---------------------5.080----------49.803 - Věda a technologie
இறைவனின் சாந்தியும் சமாதானமும் நம் அனைவர்கள் மீதும் உண்டாகட்டுமாக அருமையான அவசியமான பயனுள்ள பதிவு மிக்க நன்றி சகோதரரே
நான் இதுபோல நிறைய winding calculation video பார்த்திருக்கிறேன். ஆனால்,இந்த வீடியோ பார்த்ததும் மற்ற அனைத்தையும் மறந்துவிட்டேன். அவ்வளவு தெளிவாக இருக்கிறது.நன்றி
Nice bro transformer winding pathi supera tamil explain pannathu neenga mattum than bro
Thanks bro
மிகவும் அழகான மற்றும் தெளிவான விளக்கம் Sir, தங்களின் இந்த சேவைக்கு நன்றி... மற்றும் தொடர வாழ்த்துக்கள்
One of the best video that is available is made by you for transformer calculation. You have clearly explained with right set of formulae. I could understand all( TPV , selection of swg wrt current , core size etc.) as you have explained in details with practical calculation . Thank you very much . Take care and be safe
You are most welcome
மிகவும் நன்றி சார் ரொம்ப நாளா இதைப்பற்றி முழுவிவரம் தெரியாமல் இருந்தேன் இப்போ எல்லா சந்தேகம் தீர்ந்தது மிகவும் நன்றி நன்றி வாழ்த்துக்கள் அண்ணே
மிக்க நன்றி நண்பரே! மிக மிக பயனுள்ள சேவை அதேபோல் toroidal transformerயை பற்றி தெரிவிக்குமாறு கேட்டுக் கொள்கிறேன்
Excellent explanations. Continue to upload many more videos . Thank you very much .
Excellent Video.
Pl correct at 30-0-30 tape equation, by mistake 40-0-40 is written, but answer is correct.
other thing at many places h and w are written cm2, which should be in cm.
Regards
Yes, you are right
Thanks i am looking for this information. Dont understand your language .but Understand the concept.
Great teaching skills
Brother the video was so usefull. For my rewinding transformer project for my powersupply. 👌
Thanks for this. very very good video. after so many years, I'm very clear by this. I did subscribed immediately. :-)
Excellent bro.. expecting more video from you. God bless you
EXCELLENT PRESENTATION FOR A PRACTICAL APPROACH TO DESIGN TRANSFORMERS FOR AMPLIFIERS.
Many thanks!
Thank you very much Sir for your clear and nice explanations.
Very very nice explanation. Subcribed immediately. 👍👏 Thankyou. Please more such useful videos.
Sir, After exploring several times i got to know to find EI Laminated Core using Tongue Width, However For the derived value from Core Area i mean 36 cm2
Where Gross Core Area = 36/0.9 would return 40 cm, then i have taken sqrt(40) that comes to 6.32 as Tongue Width.
In sheet i have tried nearest value to determine somehow Couldn't make it up.
Could you please give some insight on this how to proceed further by taking alternative measures on Core Area if possible.
அற்புதமான வீடியோ விளக்கம். Inverter transformer பற்றி அவசியம் ஒரு வீடியோ விளக்கம் தரவும்.
அருமையான பதிவு நன்றி வணக்கம் 🌹🙏
Sir very good explanation about Transformer winding
Please explain calculation and rewind for single and three phase electric motor
bro very good detailed video,thanks
Super Anna I am impressed thank you
சூப்பர் சார், இதே மாதிரி தோரோடல் கோர் ட்ரேன்ஸ்பார்மருக்கும் ஒரு பதிவு போடுங்கள்
Super bro and motor design calculation pathi poduga bro
Really nice explanation
thank you, bro, normal tata core ku enna current density evlo podanum.
Excellent 👍
Very very super explain thank you bro 👌👌👌👌👌❤️❤️❤️❤️❤️
அருமையான விளக்கம் நன்றி
Thanks for ur clear explanation sir.. .In core Area that formula how get the value 1.152 root of VA . and wire dia value 1.128. pls give he solution for this.
hats off to you sir. i have been searching for this tutorial for quite long. that too in tamil. it is a real lottery. thank you sir. please explain why you don't follow the constant formula everyone gives that is 42/core area is number of turns per volt. and what is this 1.152 is it a constant.
why you have not considered peak voltage, power out, DC voltage factors. what is this standard core size table you have given. what is tongue width. please explain. also if i want to order materials for DIY project, how to place core size. will be very grateful if you upload a making video. thanks a lot sir,
Thank you so much for the information
Thank U Sir super video amplifier toroidal transformer design winding calculation video
Excellent your video transformer culcult.
Thanks sir, And also need video for Toroidal Transformer 👍
Sir thank you very much for your explanation
By the way please give the details and size of the enamel copper wire and also varnish details
Thanks 🙏
Respected Sir, please upload videos for auto transformer design calculation for manual voltage stabilizer and toroidal transformer design calculations. I expect that you may/will fulfill my request. Thank you A LOT SIR.
good bro, go ahead..................
Excellent
B value 1.3 web/m square use pandroppo core dimensions scale cm la multiply paña correct value varuma
Thanks sir. Pl. Mention the selection of core and size of core for your transformer design.
Sir if primary current is 2.42 A then we have use 2.5 Amps fuse in primary side
Marana mas explanation bro
Thank you sir, very clear. If possible audio output transformer design details. How to match the primary impedance secondary impedance
Expecting your vidieo
Veralevel bro put more videos
Sir how did we got 1.152 while calculation of cores area.? Could you please tell
Helo sir nenga super explanation clearly, konjam pulse transformer ah yepti choose pananum nu solungah
Sir this core tongue and winding area are in cm or inch ??
Plz reply
Well explained brother
Useful sir.
Your teach very very good thank you
❤❤❤Sir! enaku doubt Naa oru step up Transformer seyya poren athuku input 12v illa 6v primary coila etaavuthu onu kudutaaa output 230v secondary coil la varanum athuku power calculation formula same taana?
Naa panna porathu onu 6v 10A input taranum apadi illana 12 v 5A input taranum athuku output 230v 60w edukanum aana 60w directaa edukaa mudyaathu athu terum naa vanthu konjam taan edupen atunaala antha 60w cinfuse panna vendam ippa ithuku neengha sonna formula yetaavuthu maarumaa?
❤❤Thanks in advance❤❤
thanks for ur information
100% usefull vedeo sir
TQ bro use full video
What a explanation Brother
Ur explanation fine.
Excellent.
Sir. Excellent tutorial and very much informative and helpful.
Also would like to understand types. For example Type 3, Type-16 Have data sheet associated values with types so please take one lecture on the same.
Also to practise where can I get laminated cores and bobbin
Give Your Email id. I will share all detail presentation and core chart, etc
@@nuratechtamil1852 sir my id is rajaram.vemuri@gmail.com
All type of Lamination core and Bobbine available contact
Ph no: 98402 98744
Chennai
30 0 30 15amps 12 o 12 3amps ethukana primary wire coil and secondary wire coil core size14 erukku yathana inches core yadukanum details sollunga bro
Superrr...
Sir I want make a SOLENOID ac or dc, stroke length 60 mm or + , stroke force 2 kg, so please can you help
Sir at last you have mentioned that have explained basics and there factors to design Transformer.
If I go ahead with similar calculation for MOSFET will this work else as u have mentioned there are factors and tips ..
I would be interested to take session from you. Plz let me know how to reach you...
Yes, you can
thank you sir super video
Sir if you would give some input on core area=1.152 from where this value considered, I know core area is 12 I mean (hieght * width)
Please help also if you have table of swg and types of core to choose.. would be helpful.
How about bed type core..?
You mean Toroidal?
Anna supera puriudhu anna motor winding calculation paththi oru video podunga anna pls
Bro i am fist time transformer making pannanum transformer pathi entha details thereyaathu bro pureyira maathire video podunga bro
good video
Bro plzz explain the how to select the BBT ratio in relevant to variac
Engappa erupting ada da semma bro
Sir 20 0 20 5amps transformer watts calculation na vera mari silaper calculation panranga 20*5=watts nu solranga .ennanu konjam sollunga sir
Primary coilmela secondary coil kattumbhodhu length bread size maaruma? sir pls
Yes, correct. But it would not major difference.
Sir where is buy EI core and transformer bobbin, please kindly replay sir,
Super sir
Super explanation. Waiting for winding. Please do winding video
Will do soon
நல்ல தெளிவுரை விளக்கம்
Thank u....very cleare ..G
for secondary winding calculation 1.04 where that value coming from?
Super bro
Anna video nice na. Apdiye transformer winding panni 30-0-30 epdi edukuradhu secondary and primary epdi wire epdi suthuradhu apdinra video podunga na please
Sure. Now the arduino(Microcontroller) based automatic coil winding m/c making is in progress. So as soon as possible i ll upload the practical video of making the transformer.
@@nuratechtamil1852 super bro
Nice bro
Super
So many thanks sir
arumai bro
இத இத இதத்தான் சார் எத்தனையோ வருடங்களாக எதிர்பார்த்தேன். இந்த அளவுக்கு தெள்ளத்தெளிவாக நின்று பொறுமையாக எவ்வித கடினமான கணக்குகள் இல்லாமல் சிறப்பாக விஷயத்தை தெரிவித்திருக்கிறீர்கள். அநேக வணக்கங்கள் ஐயா. டிரான்ஸ்பார்மர் பொறுத்தமட்டில் எந்த சந்தேகமும் இல்லை. நன்றி...நன்றி...நன்றி.
Bro ups transform la epdi amp set panrathu??
Sir.. 99% purity copper la crgo m3 grade core with proper swg for primary & secondary ku wind panni kodukira transformer winder iruntha sollunga.
I need
10 amp 28 0 28
6 amp 18 0 18
3 amp 12 0 12
2 amp 9 0 9
Transformer
Not possible.
Thank you bro
மேலும் ரியாக்டன்ஸ், இன்டக்டன்ஸ், இம்பிடன்ஸ் இதைப்பற்றியும் தெரிந்துகொள்ள விரும்புகிறேன். நன்றி
நன்றி ஐயா. ரியாக்டன்ஸ், இன்டக்டன்ஸ், இம்பிடன்ஸ் இதைப்பற்றி ஒரு பதிவி கூடிய விரைவில் போடுகிறேன்.
Bro ampere nambale assume panratha
Sir can u explain 2 - 12v battery eliminator 2 amps calculations
Anna very super anna
Sir please one calculation for current transformer calculation examples 100-50/5-5A design
4KVA 90 to 300v input, output 170v to 250v calculation required. Ur discription easily under stood. Than other.
Please upload a video for motor winding data calculation and generator winding calculation
Bro how about making in ferrite core.. Do we not change anything in formule or is it same for that too..?
Yes. The formula is different for Ferrite core.
@@nuratechtamil1852 could you please upload that too bro..?
Sir , one doubt, transformer rating kva, or va dhana watts la sollalama.
The KVA mentioning is only for power exchangeable or power generated devices. Like Transformer, alternator,etc.
The watts or W is for Power consumable devices,like Bulb, motor,any load..
Pro 1870 watts output குடுக்குற transformer cor la 1200 watts output winding எடுக்கலாம்
Bro . What is the rule for 42 .becasue some people say 42 /width×length and this is the number of turns.. can u explain this rule
They simplified the formula with constant frequency and magnetic flux value. So only easy to use. Just you solve the formula with 50 hz and Fx 1.1 without the core area. The answer will come nearest to 41 to 45.
24or26v to 50-0-50 20amp ferried transformer winding smps irf250*4 MOSFET primery turns and secondary turns please detail friend