Configure CC-LINK system MELSEC-Q PLC - P16 | Cấu hình và test mạng CC-LINK của PLC dòng Q

Sdílet
Vložit
  • čas přidán 14. 12. 2020
  • Video này mình hướng dẫn cấu hình và test mạng CC-LINK của PLC Mitsubishi dòng Q. Module QJ61BT11N dùng để cấu hình Master or Local station.
    In this video, I guide the configuration and test of CC-LINK network of PLC Mitsubishi MELSEC-Q series. Module QJ61BT11N is used to configure Master or Local station.
    Automation | Mitsubishi
    1. GX Works2 : Installation & Simulator - P1 I Cài đặt và chạy mô phỏng PLC Mitsubishi 👇
    • GX Works2 : Installati...
    2. How to install GT Designer3, HMI Mitsubishi - P2 | Cài đặt phần mềm lập trình HMI Mitsubishi 👇
    • How to install GT Desi...
    3. How to Upload & Download program Mitsubishi FX3U PLC by GX Works2 - P3 | Upload và Download PLC FX 👇
    • GX Works2: How to Uplo...
    4. GT Designer3: Upload and Download program HMI GOT2000 by USB cable - P4 👇
    • GT Designer3: Upload a...
    5. GT Designer3: Upload and Download program HMI GOT2000 by Ethernet cable - P5 👇
    • GT Designer3: Upload a...
    6. GX Works2: Upload & Download program Mitsubishi PLC MELSEC-Q Series by ethernet cable - P6 👇
    • GX Works2: Upload & Do...
    7. How to connect GOT2000 HMI with MELSEC-F Series PLC - P7 . Tạo kết nối HMI Mitsubishi với PLC FX 👇
    • How to connect GOT2000...
    8. How to Upload, Download and Monitor the PLC program via GOT - P8 | Download chương trình PLC qua HMI 👇
    • Upload, Download and M...
    9. GX Works3: Installation & Simulator - P9 I Cài đặt và chạy mô phỏng PLC Mitsubishi 👇
    • GX Works3: Installatio...
    10. How to simulate GT Designer3 with GX Works2 - P10 | Kết nối GT Designer3 với GX Works2 qua mô phỏng 👇
    • How to simulate GT Des...
    11. GX Works2: How to connect KEPServerEX with MELSEC-Q Series by ethernet driver - P11 👇
    • GX Works2: How to conn...
    12. FX3U PLC: Communication Modbus RTU with E5CC Temperature Controller - P12 | Truyền thông Modbus RTU 👇
    • FX3U PLC: Communicatio...
    13. How to connect WEINVIEW HMI with FX3U PLC - P13 | Tạo kết nối HMI WEINTEK với PLC FX 👇
    • How to connect WEINVIE...
    14. MR Configurator2: How to Install, Read & Write parameters Servo Amplifier - P14 | MELSERVO-J4 👇
    • MR Configurator2: How ...
    15. How to connect Proface HMI with MELSEC-Q Mitsubishi PLC via Ethernet Port - P15 👇
    • How to connect Proface...
    16. Configure CC-LINK system MELSEC-Q PLC - P16 | Cấu hình và test mạng CC-LINK của PLC dòng Q 👇
    • Configure CC-LINK syst...
    Các bạn nhớ ủng hộ mình bằng cách nhấn Like và đăng ký kênh mình nha.
    Nếu có yêu cầu gì thì comment bên dưới giúp mình .
    Remember to support me by clicking Like and Subscribe to my channel.
    If you have any questions, please comment below.
    #ThuanAutomation
    Thank You & Best Regard !!!
    ***********************************
    ☆ FOLLOW " Thuan Automation "
    ▶ Email : thuan.automation3003@gmail.com
    ▶ Phone : +84 931359303
    ▶ Subscribe : bit.ly/2RKbVD3
    ▶ Facebook : / thuanautomatic
    ▶ Zalo : zaloapp.com/qr/p/hjzjeafqnsei
    ***********************************
    © Bản Quyền Thuộc Về Kênh Thuan Automation
    © Copyright by Thuan Automation Channel
    ⛔️ Do not Reup

Komentáře • 142

  • @ThuanAutomation
    @ThuanAutomation  Před 3 lety +3

    Video này mình hướng dẫn cấu hình và test mạng CC-LINK của PLC Mitsubishi dòng Q.
    In this video, I guide the configuration and test of CC-LINK network of PLC Mitsubishi MELSEC-Q series.

  •  Před 3 lety +1

    chia sẻ hay quá bạn ơi Cấu hình và test mạng CC-LINK của PLC dòng Q

  • @vuongvubac5744
    @vuongvubac5744 Před 3 lety +1

    Rất chi tiết - cảm ơn

  • @kpschannel6706
    @kpschannel6706 Před 2 lety

    I've never tried Q series, its interesting...But I've tried FX series..
    I Will try .. thanks

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety

      Ok you. If i have the cc-link fx plc, i will make video

  • @nanangjeni9725
    @nanangjeni9725 Před 3 lety +1

    Nice from indonesia

  • @sudalaimuthup
    @sudalaimuthup Před 3 měsíci

    good video...
    from india

  • @sathishs1265
    @sathishs1265 Před 2 lety +1

    Excellent

  • @tientran-mu6yw
    @tientran-mu6yw Před 11 měsíci

    anh cho em hỏi em muốn khi chuyền giữ liệu tới trạm bị lỗi báo được lên HMI thì làm cách nào ạ. có cách nào gắn cờ báo cho các trạm không anh?

  • @dungtranvan8221
    @dungtranvan8221 Před 3 lety +1

    Anh ơi anh làm thêm phần video truyền thông giữa 2plc mitsubishi Q đi an

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      Em muốn truyền thông qua chuẩn nào

    • @dungtranvan8221
      @dungtranvan8221 Před 3 lety

      Anh làm phần truyền thông giữa 2 modul Q3DVCPU ,Qj71C24N _Q3DVCPU-QJ71C24R

  • @tienhoangnguyen7322
    @tienhoangnguyen7322 Před 3 lety +1

    a cho e hỏi ưu điểm của điều khiển bằng hệ thống trạm CC-link thì hơn gì so với chỉ dùng thiết bị mở rộng đầu vào ạ....trong 1 hệ thống e chỉ dùng bộ mở rộng thay vì dùng trạm đc ko ạ

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety +2

      Nếu trạm bơm em ở gần thì kéo dây tín hiệu in/out trực tiếp. Nếu trạm bơm ở xa em kéo chỉ 1 dây mạng nó gọn mà đỡ tốn công, chi phí.

  • @atpanda3008
    @atpanda3008 Před 3 lety +1

    e không có điện trở 110ohm thì có thay được điện trở giá trị khác không hay có thể không đấu trở thì liệu nó có chạy không ạ.

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      Nếu gần thì có thể dc, xa thì không được

  • @thanhnguyen-xn2gk
    @thanhnguyen-xn2gk Před 3 lety +1

    Cho mình hỏi khai báo remote i/o mà không có hiện ra remote i/o giờ mình phải làm sao

  • @vanminhtrip
    @vanminhtrip Před 2 lety

    Anh làm thêm phần cclink của dòng fx3u 16CCL-M. Dòng này e thấy dùng nhiều nhưng trên youtube chưa thấy ai làm kĩ

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety

      Uh em, hiện tai anh chưa có thiết bị để làm

  • @tankienfei1006
    @tankienfei1006 Před 3 lety +1

    do you have any video using CC-Link with analog input and analog output ?

  • @aocongtuong6958
    @aocongtuong6958 Před 3 lety +1

    Cho em hỏi chỗ Mode mình chọn là Remote Net Ver.2 thì xó sự khác biệt gì. Cty em có 1 máy em xem cấu hình chỗ start I/O No là 0200 còn remote inpute là X1000. Khi dùng thì gọi X1200.

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      Chủ yếu khác số lượng thanh ghi cho phép đọc ghi, vùng x và y khai bao bao nhiêu cũng được

    • @aocongtuong6958
      @aocongtuong6958 Před 3 lety +1

      @@ThuanAutomation ý e khi cài đặt remote input đặt cho trạm số 1 là X1000. Nhưng khi lập trình thì lại thành X1200.

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      @@aocongtuong6958 cấu hình trạm đó nó bỏ qua thì nó nhảy địa chỉ thôi

  • @tuongpham3449
    @tuongpham3449 Před rokem

    có video cấu hình dòng FX3U không anh

  • @nhiennguyen5175
    @nhiennguyen5175 Před 3 lety +1

    Bạn cho mình hỏi. Bạn có dậy lập trình plc dòng mitsubishi dòng Q.. Này không?

  • @thanhbinh7687
    @thanhbinh7687 Před 3 lety +1

    Dây micro usb kết nối plc mua ở chỗ nào bác nhỉ

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      Em lên google search USB Mini, có nhiều chỗ bán lắm, giá rẽ

  • @LYNGUYEN-yp8lc
    @LYNGUYEN-yp8lc Před 2 lety +1

    Anh ơi cho em hỏi , ở mục Reservred/invaild em thấy chọn chế độ no setting , vậy khi nào thì chọn chế độ reservred vậy anh

  • @tothanhat2540
    @tothanhat2540 Před 3 lety +1

    cho e hỏi chút ạ . ở đẩu đầu và đầu cuối lắp thêm con trở có tác dụng gì ạ

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety +1

      Xác định điểm đầu và cuối

    • @tothanhat2540
      @tothanhat2540 Před 3 lety +1

      E vẫn chưa hiểu dõ lắm . Cách hoạt động nó ý anh . A có tài liệu nào chỉ cách hoạt động của cclink vs master ko ạ

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      @@tothanhat2540 em search tài liệu của nó trên mạng

  • @taiyou5182
    @taiyou5182 Před 3 lety +2

    Em không tìm được AJ65SBTB1-32D thì phải làm sao ạ

  • @AreebAhmed08
    @AreebAhmed08 Před 3 lety +1

    Very nice. It helped me alot. But please tell me why you use x300 and y300 instead of x0 y0. Also tell me please what is the purpose of sw0 and sb0. Waiting for your expert answer.

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety +2

      I use input X500 and Y500 why not use X0,Y0 . Because you can use X0,Y0 for input and output module plug on base main.
      W0 and W100 are area to read and write data of CC-Link module

    • @AreebAhmed08
      @AreebAhmed08 Před 3 lety +1

      @@ThuanAutomation why use sb0 and sw0

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      @@AreebAhmed08 They are relay and register special.
      It requires you to use SB and SW, you can use other 0 for example 100

    • @AreebAhmed08
      @AreebAhmed08 Před 3 lety +1

      In QnA CPU my Parameters are : X300 Y300.
      D0 D100
      and special relays and special registers and empty. it works fine. but Manufacturer used SB0 and SW0 and they also use SRAM card

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      @@AreebAhmed08 SB0 and SW0 are memory in plc no need memory card

  • @hapham-qd4jl
    @hapham-qd4jl Před 2 lety +1

    e đang connect HMI Touchwin TG765-ET với plc Q03UDECPU qua module QJ71c24N giao tiếp RS232. e đã cấu hình trong Switch setting. hiện tại module không báo lỗi. nhưng vẫn không connect dc 2 cái vs nhau. a giúp e vs. thanks a

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety

      Em kiểm tra lại sơ đồ cáp, setting trong plc và hmi

    • @ThaoNguyen-fz4xg
      @ThaoNguyen-fz4xg Před 2 lety

      @@ThuanAutomation a cho em xin số dt hoặc email với a

    • @ThaoNguyen-fz4xg
      @ThaoNguyen-fz4xg Před 2 lety

      Modul AJ65SBTB1-32D đèn LEr nhấp nháy và thỉnh thoảng mất đèn LRUN. Là bị lỗi gì a

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety

      @@ThaoNguyen-fz4xg kiểm tra lại dây, setting

    • @ThaoNguyen-fz4xg
      @ThaoNguyen-fz4xg Před 2 lety

      @@ThuanAutomation dạ , hệ thống cc link bên em đang chạy bình thường gần 1 năm nay thì tự nhiên bị. Tất cả có 8 trạm cclink , có lúc thì báo lỗi 2 tram, lúc thì báo 3-4 trạm. A cho em xin thông tin em gửi mail hình ảnh nhờ a xem giúp dc ko a

  • @tuyenbui6413
    @tuyenbui6413 Před 2 lety

    sao phần device list của e không có mấy cái modult như biến tần hay remote io nhỉ

  • @dotran1305
    @dotran1305 Před rokem

    SAO MÌNH TÌM MODUM KHÔNG RA BẠN NHỈ.MONG BẠN GIẢI ĐÁP

    • @NguyenTanDat23
      @NguyenTanDat23 Před rokem

      Sao mình ko tìm thấy modul.mong bạn chia sẽ

  • @thachchau7068
    @thachchau7068 Před 2 lety +1

    nếu ko có điện trở thì có vấn đề gì ko anh

  • @Animevn159
    @Animevn159 Před 2 lety

    Cho em hỏi là phần mềm GX Work2 của em khi bật mô phỏng thì bị lỗi cannot cumminicate PLC ạ, mong anh phản hồi ah

  • @minhduynguyen3160
    @minhduynguyen3160 Před 3 lety

    khi lam xong thì chỉ được 1 tác dụng thôi . 1 là IN 2 Là OUT . e sử dụng AJ65SBTBT- 8D AJ65SBTBT- 16T. GIÚP E VỚI

  • @AhmedMohammed-rm3yy
    @AhmedMohammed-rm3yy Před 8 měsíci

    Why Y520 is Y0 on CC-Link while Remote output start from Y500?

    • @ThuanAutomation
      @ThuanAutomation  Před 8 měsíci

      You setting in the parameter

    • @AhmedMohammed-rm3yy
      @AhmedMohammed-rm3yy Před 8 měsíci

      @@ThuanAutomation
      I mean, you set the remote ouput start from y500,but while you closed y520 , y0 become 1.
      Is y0 = y500 not y520?

    • @ThuanAutomation
      @ThuanAutomation  Před 8 měsíci

      @@AhmedMohammed-rm3yy Start module input from X500 to X51F is station 1. Y520 to Y52F is address station 2

    • @AhmedMohammed-rm3yy
      @AhmedMohammed-rm3yy Před 8 měsíci

      Ok, but why you set in setting RY=500 as RX? @@ThuanAutomation

    • @ThuanAutomation
      @ThuanAutomation  Před 8 měsíci

      @@AhmedMohammed-rm3yy you should read document. Startion 2 begin from Y520 not Y500. If next input module startion 3 . It from X540, not X520

  • @tankienfei1006
    @tankienfei1006 Před 3 lety +1

    How do you know the output starts from Y520 instead of Y500 ?

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety +1

      You setting station is 2

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety +1

      @@haodau trạm 1 chiếm 32 bit. Trạm 2 kế tiếp phải là Y520

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety +1

      @@haodau đọc tài liệu plc lạ đi nó qui định địa chỉ plc là thế nào, hỏi câu ,...

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety +1

      @@haodau mở tài liệu đọc đi

  • @hoannguyen2615
    @hoannguyen2615 Před 2 lety

    Không gắn điện trở đầu cuối xẩy ra lỗi như nào anh ơi xin chỉ giáo

  • @vanminhtrip
    @vanminhtrip Před 2 lety

    A làm thêm phần cclink fx3u 16ccl-m

  • @dtentertainment953
    @dtentertainment953 Před 2 lety

    A ơi.. tại sao mình cấu hình Y bắt đầu là Y500.Mà khi ON Y500 thì không được mà phải ON bắt đầu từ Y520.

  • @uynguyenuy8223
    @uynguyenuy8223 Před 3 lety +1

    nếu e cấu hình trạm Master có 4 trạm io. nhưng e ko lắp trạm 1 mà chỉ lắp 3 trạm thì có lỗi ko bác

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      Bình thường nha em

    • @uynguyenuy8223
      @uynguyenuy8223 Před 3 lety +1

      @@ThuanAutomation vâng. cảm ơn bác. em xin hỏi thêm. trước e đã cấu hình và dùng 4 trạm rồi. chạy bình thường. giờ muốn gỡ trạm 1 không dùng nữa thì có cần khai báo lại không bác

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      @@uynguyenuy8223 có nha em

    • @uynguyenuy8223
      @uynguyenuy8223 Před 3 lety +1

      @@ThuanAutomation e thấy bác bảo cấu hình 4 nhưng dùng 3 vẫn bình thường mà

    • @ThuanAutomation
      @ThuanAutomation  Před 3 lety

      @@uynguyenuy8223 vẫn bình thường nhưng em phải setting lại và download chương trình xuống

  • @trangvo393
    @trangvo393 Před 2 lety

    mình muốn cài lại cái driver melsec cc-link sao bạn

  • @Myclips83
    @Myclips83 Před 2 lety

    Bạn cho mình hỏi, mình cc-link trên các PLC FX3U có tương tự không ah ?

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety +1

      Hơi khác nhau

    • @Myclips83
      @Myclips83 Před 2 lety

      Khi cclink 2 PLC fx3u thì địa chỉ trong chương trình đánh dấu như thế nào bạn nhỉ, ví dụ: sẽ có 2 X0, 2 X1......hic, mình chưa làm cclink bao giờ, bạn đã làm video về vấn đề này chưa.

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety +1

      @@Myclips83 nó giống đánh địa chỉ của fx khác dòng q thế nào thì nó là vậy

  • @honkaofficial19
    @honkaofficial19 Před 3 lety +1

    na có link tải phần mềm này k a

  • @rizkymaulana7766
    @rizkymaulana7766 Před 2 lety

    Can you tell me sir, why you use X500 & Y500 not X300 & Y300?

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety

      You can use X300 or Y300. You setting in the parameter. If you use a lot of IO modules you should not use X300, Y300

    • @rizkymaulana7766
      @rizkymaulana7766 Před 2 lety

      @@ThuanAutomation im use master cc link QJ61BT11N (1pcs) Aj65SBTB1-32D1 (1pcs) AJ65SBTN1-32T1 (1pcs) sir.
      What is different of X300 Y300 and X500 Y500 sir?

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety

      @@rizkymaulana7766 you can use X300,Y300

    • @rizkymaulana7766
      @rizkymaulana7766 Před 2 lety

      @@ThuanAutomation thanks for sharing your knowledge sir.

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety

      @@rizkymaulana7766 ok you

  • @ammechimcanh6842
    @ammechimcanh6842 Před 2 lety

    Your video is very good. Can you tell me why I set Start XY to 20? Thank you very much!

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety +1

      Adress of CC-link module in the parameter

    • @ammechimcanh6842
      @ammechimcanh6842 Před 2 lety

      ​@@ThuanAutomation
      I understood thank you very muchch!

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety +1

      @@ammechimcanh6842 ok you

    • @ammechimcanh6842
      @ammechimcanh6842 Před 2 lety

      @@ThuanAutomation Hello, I have 10 CC link I/O modules. Including 5 In, 5Out. I configured in the order of 2In,2Out,3In,3Out, then in the Rx address setting I set X000, now 5 I/O Input modules will run from X000 to X09F, right?

    • @ThuanAutomation
      @ThuanAutomation  Před 2 lety +1

      @@ammechimcanh6842 You should set address from X500 and Y500

  • @luank8599
    @luank8599 Před 2 lety

    a ơi cho e xin file tài liệu pdf được không ạ

  • @sonhoang-ij9oe
    @sonhoang-ij9oe Před rokem

    Giá cả bộ bao nhiêu ạ

  • @ThienNguyenuc-di8pp
    @ThienNguyenuc-di8pp Před 2 lety

    Cho e xin số đt của a để liên lạc khóa học ah!