Video není dostupné.
OmlouvĂĄme se.

SUKAT NG BIGA AT DETALYE NG BAKAL.

SdĂ­let
VloĆŸit
  • čas pƙidĂĄn 7. 03. 2021
  • BEAM DEATAILS , REINFORCEMENTS, TOP BARS AND BOTTOM BARS FOR REINFORCED CONCRETE BEAM.
    This video is NOT sponsored. Some product links are affiliate links which means if you buy something we'll receive a small commission.
    BUILDMATE: invol.co/cl5y7rd
    Buildmate Online Depot
    Welcome ka dito Ka-BUILDMATE! 👋
    🚧Your One Stop Hardware Shop is always here
    with the most complete home & living needs.
    Be updated with our Special offers because every day
    is Guaranteed LOWEST PRICE with us 🎉
    ✹DAILY VOUCHERS GIVEAWAY with just one click
    in our ✅FEED Section & Chat button.
    plus our Special 🚛 FREE SHIPPING deals
    What are you waiting for?
    Follow us and Get a Voucher now!
    Home improvement design (Art Design PH): invol.co/cl5lx7p
    Online Shopping Platform (LAZADA PH):invol.co/cl5lx98
    Shop Online Specialized in hard to find items (Galleon PH): invol.co/cl5lxab
    The Ultimate online shopping Experience (Ubuy PH): invol.co/cl5lxdb

Komentáƙe • 400

  • @josetagalog5145
    @josetagalog5145 Pƙed měsĂ­cem +1

    Ang sarap makinig ng paliwanag. Para akong nag-aaral, very informative. Tamang-tama, plano ko magpagawa ng bahay by early next year. Salamat sa maganda at malinaw mong pagtuturo.

  • @fmcookandtasteshow5176
    @fmcookandtasteshow5176 Pƙed rokem +1

    Good day sir..im 38 yrs old..my experience konte sa construction..plano ko sana mag enroll bilang civil engineer..salamat sa mga video nio..talagang nakakatulong

  • @user-mq8lm3cq2z
    @user-mq8lm3cq2z Pƙed 7 měsĂ­ci +1

    Share ko lang din po, na yung b (base) must not be equal or less than 0.4d (depth) = meaning if yung 'd' ng beam nyo is 0.5m, dapat hindi aabot or bababa yung base nyo ng 0.2m. > which is yung gamit ni sir na > factors for computing 'b' na 1.5, 1.4, at 1.3 is Safe Ratio for Beam Dimensions. NICE.

  • @Carlo-ws7km
    @Carlo-ws7km Pƙed 3 lety +24

    Asko ko sir kung Lic. Civil Engineer kayo or Architect kasi concern lang ako sa min. Na bakal na sinasabi nyo sir. Isa akong structural Engineer as per code ang min na bakal ay 16mm dia hindi 12mm dia. 5mtrs pa naman yang sinasabi mo na haba ng beam. Ok lang mag bigay ng idea or information pero pag hindi sure sir minsan kailangan din basahin uli ang code paka kasi naka ligtaan mo lang.

    • @XERTZ1925
      @XERTZ1925 Pƙed 3 lety +1

      pwede yan sa 3m span thumb rule pero sa 5m span pwede rin basta sa roof lang ng garage at walang pupuntang mga tao or live loads mo lang siguro pusa.

    • @noobslayer2441
      @noobslayer2441 Pƙed 3 lety +2

      "experience is the only source of knowledge"..... Hnd lahat ng bagay ay nasa libro...

    • @HanzotheSalamander.
      @HanzotheSalamander. Pƙed 2 lety +2

      @@noobslayer2441 Hindi lahat ng bagay nasa libro tama. Pero akala mo ba hinulaan lang yung mga nilagay sa libro? Base yun sa mga tests and experiences na sinasabi mo

    • @HanzotheSalamander.
      @HanzotheSalamander. Pƙed 2 lety +3

      Nakalimutan lang siguro magbasa ni kuya ng code

  • @lasktrob2715
    @lasktrob2715 Pƙed 3 lety +11

    Hey guys please Consult Civil/Structural Engineer. Rule of thumb is dumb things of the past construction of any structure is serious business if mistake occur occupant will result to injury and worst death.

  • @princebasaya950
    @princebasaya950 Pƙed 2 lety +2

    Ang galing po ninyo sir mag explain. Kahit kumplikado ang topic, madali niyong napapaliwanag nang maayos. Dami ko pong natutunan. Salamat sir

  • @franciscovelasquez9734
    @franciscovelasquez9734 Pƙed 3 lety +4

    Excellent tutorial hindi ka suplado or mayabang ang dating pang masa ang explanation mo at malinaw kahit student maeencourage manood at makinig maraming salamat po more power keep ssfe po sir ingat po sa covid god bless po

    • @GabsRomano
      @GabsRomano  Pƙed 2 lety

      Thanks for watching

    • @leonardofetalvero6942
      @leonardofetalvero6942 Pƙed 2 lety

      sa studyante baka magdalawang isip kung nakabasa na ng nscp,kay engr,rule of thumb at experience ang nakikita ko at simplified design.

  • @arjayfernando8053
    @arjayfernando8053 Pƙed 5 měsĂ­ci

    Ang galing nyo Po mag explain sir. Salamat Ang Dami ko Po na tutunan sa Inyo. ❀❀❀ Good bless po

  • @engrhidalgo
    @engrhidalgo Pƙed 3 lety +9

    Engr. Gabs very helpful and interesting presentation. I would like to add only the importance of proper Anchorage of steel embedded inside the columns to develop the stresses.

  • @dennisfideli.estrella6060
    @dennisfideli.estrella6060 Pƙed 3 lety +5

    Thank you very much Engr Gab... very helpful ang mga Rules of Thumb, Factors of Safety, yung mga bunga ng experience sa construction... I appreciated your video very much... lalo sa Cost Estimates ng project... salamat talaga!

  • @3AGCONSTRUCTION
    @3AGCONSTRUCTION Pƙed měsĂ­cem +1

    Good job sir

  • @watchme7192
    @watchme7192 Pƙed 3 lety +1

    may napanood ako na video na naka bend ang bakal pero di ko maintindihan kala ko design lang . pero sa video n ito gets ko na. maraming salamat Sir share ko ito .

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety +1

      Please do share and thanks for watching po.
      Have a nice day

  • @milagroslayug964
    @milagroslayug964 Pƙed rokem

    Thanks engr.may natutuhan na Naman Ang asawa ko.simpleng contractor lang kasi siya.

  • @rocco8592
    @rocco8592 Pƙed 2 lety +1

    For ROT of beams kung residential dapat 3m lng ang distance between columns plus 1/3 of the total lenght for cantiliver,para siguradong safe.mas mahaba kasi ang lenght ng beam,mas lumalapad ang size ng biga,at mas lumalaki din ang size ng poste.mas maigse ang pagitan ng poste mas safe sa biga,the longer the span of a beam needs more extra bars.

  • @perlitocaballa1551
    @perlitocaballa1551 Pƙed 3 lety +1

    Sir sana po sa susunod na vedeo kung papano po naman iyong mga reinforcement sa slab at ano po iyong single wire mess at double wire mess at papano e apply salamat po boss Idol ang galing mong mag explain malinaw

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety +1

      ok po , salamat po sa pagtangkilik.

  • @johnvem6432
    @johnvem6432 Pƙed 3 lety +1

    Napaka basic po sir, ang Dali pong intindihin. Salamat ng marami

  • @javierreyes6251
    @javierreyes6251 Pƙed rokem

    Engr.gab romano maraming salamat po sa pashare nyo sa amin ng inyong kaalaman.đŸ‘â€

  • @carlvokscabigas2416
    @carlvokscabigas2416 Pƙed 17 dny

    Boss idol.. penge idea ng concrete mixing ratio para sa column , long span beam at lomg span slab

  • @rogergonzaga6346
    @rogergonzaga6346 Pƙed 2 lety

    Ganda ng paliwanag mo enginer, naintindihan ko ng hosto, salamat sa paliwanag sir,,,

  • @bhingvillanueva4840
    @bhingvillanueva4840 Pƙed 2 lety

    Salamat Po Ng inyong binahaging karagdagsn naming kAalaman engr..godbless Po sir

    • @GabsRomano
      @GabsRomano  Pƙed 2 lety

      Maraming salamat po, have a great day

  • @cezexploresvlogs
    @cezexploresvlogs Pƙed 2 lety +1

    Biga namin 30x40 L/3 meron syang extra bar n 3 pcs haligi sa haligi ung guitna 2 malalaking bakal n nk hook. bale 4 n bakal n sa baba.

    • @GabsRomano
      @GabsRomano  Pƙed 2 lety

      Thats good po. Thanks for watching

  • @podztv7478
    @podztv7478 Pƙed 2 lety +1

    Maramng salamat po sir very imformative

  • @paolopablo5292
    @paolopablo5292 Pƙed 3 lety +10

    A good thing to know how to get the ratio of the cross-section of the typical beam design using its length.
    Base on my experience, the structural engineers usually allow 1 to 2-50mm 10mm rebar stirrups along with the end support of the beam before allows 4" to 6" spacing of the first quarter of the length then rest 8" toward the center. Another thing, the Structural Code (NSCP) allows only a minimum of 16mm rebar reinforcement. Lower than 16mm rebars like 12mm and 10mm are prohibited to use. Probably because of the seismic loads I think. Anyway, thanks for the lesson. =)

    • @aureliotorres2408
      @aureliotorres2408 Pƙed 2 lety

      Medyo lakas lakas an mo ang boses kasi sa mga mHihina ang mga pandinig konting lakas at ayos ka na.

    • @ryanmedrina9411
      @ryanmedrina9411 Pƙed 2 lety +1

      Kapag residential lang na maliliit, hindi na ginagamit ang NSCP na yan. Kinukuha na lang lagi ang minimum... Bahay ko nga 2 flrs pa 10mm lang ang lahat ng bakal at 9mm mga anillo... Inabutan na nung malakas na lindol dati, buo pa... Sa building siguro magcode ka o sa mga mansion na bahay, sa maliliit, hindi na, kaekekan lang yan...

    • @ivanacejomotorattv7934
      @ivanacejomotorattv7934 Pƙed 2 lety +1

      @@ryanmedrina9411 sir sana masagot mopo ako sa 50sqm may 6pcs na poste 4pcs 12mm at 2pcs 10mm tapos 10mm din anilyo, sa biga naman 12mm 4pcs tapos 9mm anilyo pwede napo ba?

    • @alterm1347
      @alterm1347 Pƙed 2 lety +1

      Eto tanong ko e kung ang common ginagawa sa beam ay d10 spaced na 1 to 2-50mm, 100mm hangang sa first quarter ng beam and rest 200mm. Paano naman sa column? May idea po ba kayo? L/4 din ba limit sa spacing ng 50mm to 100mm or L/3 o may ibang limit length? Para malaman sana na sakto ang design na hindi magover/under reinforced ang column at beam.

  • @rudyfernando916
    @rudyfernando916 Pƙed 3 lety +5

    Nice video presentation. Well done and very informative. Observed ko lang sa construction, kulang sa detalye ang mga drawings regarding bale or joint ng bakal sa dugtungan ng poste at biga sa sons floor or upper floor, Kaya diskarte ng carpintero ang nasusunod na minsan ay mali. Kung may lindol at gumalaw ang building problema marahil. (2) hindi gumagamit ng spacer (pagitan ng forma at bakal) resulta ng buhos nakalabas ang bakal sa concrete or walang concrete cover ang bakal (3) hindi sealed ang forma para sa poste or biga, kaya tagas ang concrete mix at sometimes resulta ng buhos ay ampaw. (4) ang bakal galing hardware ay minsan undersize, kailangan gamitan ng caliper to make sure masunod ang sukat ayon sa plano or bumili ng next bigger size rebar. Is there any problem to oversize the rebar, magastos pero matbay sa lindol?? Salamat Engr. Romano for sharing. Sana supportahan mag subscribe ng 1M pinoy ang bawat isang pinoy vlogger - Sir, you deserve that 1M . God bless.

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety

      Thank you po for bringing this matter sana po maresolve ung mga importanteng details saka masunod ung expected standards especially sa management ng construction.

  • @richardatanacio4049
    @richardatanacio4049 Pƙed 2 lety

    Thank u so many much engineer, I learnt a lot from ur vlog

  • @jadebaes2354
    @jadebaes2354 Pƙed 2 lety

    galing mag explain naunawaan ko agad salamat sir

  • @lofiworld6213
    @lofiworld6213 Pƙed 2 lety +1

    Very informative yung vlog nyo sr, more power to you po, ask ko lng po, kc yung size ng poste for 2 storey is 200mmX300mm pwede po ba na gawin ko na size ng beam is 200mmX300mm rin po? para magkaparehas sya nang laki but yung mga size ng steelbar po ay standard nmn po..medyo malaki kc yung 10inch X 16inch na beam po. Thanks in advance po

  • @wilsa.wilson2755
    @wilsa.wilson2755 Pƙed rokem +1

    Sir nasa bundok kmi sa Rizal yon gumagawa sa amin yon (FTB) biga sa pundasyon parang hagdanan style

  • @raymundbunyi7996
    @raymundbunyi7996 Pƙed 3 lety +2

    Salamat sir sa knowledge

  • @virgilioabalos7559
    @virgilioabalos7559 Pƙed 2 lety +1

    Engr isa ako sa subscriber mo at sumosubaybay sa mga vlog mo. Kaylangan ko ng advice mo engr. May plano ako magpatau ng bahay 5x6 2story na tubular at phenolic ang sahig 9poste may isa sa gitna 2.5 meters lang pag itan ng bawat poste. Pwedi bang gamitin kng bakal sa poste ay 6na 12mm? At pwedi ko bang gamitin sa beam ang 12mm pls..

  • @reneflorencio3014
    @reneflorencio3014 Pƙed 2 lety

    Ang aking rule of thumb sa size ng beam is multiply the length by 0.09. Ito ang depth ng beam. 3 m L depth is .27. 4 mL is .36m

  • @katebalolongtv6861
    @katebalolongtv6861 Pƙed 2 lety

    Thank u for sharing po. Lagi ako ngnonood ng video nyo. Tanong ko po sana kung ung 5m na layo ng poste. Kung mag oover hang pa po xa pwede paba at ilang meters po pwedeng iover hang?

  • @lesleiangelicag.floresca541
    @lesleiangelicag.floresca541 Pƙed 3 lety +1

    Thank you po sir for teaching us! More power po

    • @josepalazon6349
      @josepalazon6349 Pƙed 3 lety

      Sir 4x4 m 7 Ang poste pero
      Kalahate git na dereyso ang beaming 2m at SA gilid dereyso pwedi poyan. Taming Lang po

  • @reynaldosira5770
    @reynaldosira5770 Pƙed 3 lety

    Free Learning on CZcams. Thanks for sharing.

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety +1

      Thanks for watching sir and have a great day.

  • @michaelmelocoton8197
    @michaelmelocoton8197 Pƙed 3 lety +1

    Very good content sir..

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety

      salamat din po sa pagtangkilik sir

  • @carlitogloria5521
    @carlitogloria5521 Pƙed 3 lety

    Sir nag subsribe ako dahil maganda ang poliwanag mo step by step at mga materyales n gagamitin. 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏

  • @user-sl8mm6et2l
    @user-sl8mm6et2l Pƙed rokem

    napaka gandang lesson.....bigs thanks

    • @GabsRomano
      @GabsRomano  Pƙed rokem

      Thank you rin po for supporting this channel sir

  • @archie1680
    @archie1680 Pƙed 3 lety +1

    galing mo magexplain. new subscriber here.

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety +1

      maraming salamat po sa pagtangkilik.

  • @marvinjaspercastaneda5030
    @marvinjaspercastaneda5030 Pƙed 3 lety +1

    Nice content sir. Very helpful po.

  • @casparroofingchannel
    @casparroofingchannel Pƙed 3 lety +1

    Thanks for this Bro.. Very informative

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety

      Salamat din bro, I also like ur channel and keep growing sir

  • @miguelpalileo3890
    @miguelpalileo3890 Pƙed 3 lety +2

    More power engr i've learned so many things from you👍👍

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety

      Happy to hear that! salamat po sa pagtangkilik sir

  • @NVM-JC
    @NVM-JC Pƙed 3 lety +1

    Salamat po dami kong nattunan đŸ„ł
    Sana po sa ssunod magkaroon kayo about sa CANTILEVER BEAM
    SALAMAT PO 😇

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety +2

      Yes po I will upload cantilever beam soon.
      Thanks for watching and have a nice day.

  • @esperanzajacob3910
    @esperanzajacob3910 Pƙed 10 měsĂ­ci

    Very well explained. Thank you.

  • @cezexploresvlogs
    @cezexploresvlogs Pƙed 3 lety +1

    Request naman po..ung second floor gagwing 3rd floor na may roof deck? Thnks

  • @glennarriola9308
    @glennarriola9308 Pƙed rokem

    Very Informative po ser.
    👍👍👍

  • @missunique989
    @missunique989 Pƙed 3 lety

    Thanks poh s information malaking tulong poh .god bless poh.

  • @dennispajalla844
    @dennispajalla844 Pƙed 2 lety +1

    Ayoz!!Sir..may idea napo ako..tnx

  • @denmarlhuns7216
    @denmarlhuns7216 Pƙed 3 lety

    Thank you bro! I learned alot from you 2day. Mhalaga tlga yung tinuro mo ngayon kasi nagkaroon ng knowledge sa beam construction. Ty!

  • @dennisaldea4790
    @dennisaldea4790 Pƙed 3 lety

    so clear ng pag paka explain .

    • @mahirapipilit4452
      @mahirapipilit4452 Pƙed 3 lety

      kung nakikinig ka lamang sa guro mo sa college ay ganoon din yan.

  • @Federico_Madriaga_Jr
    @Federico_Madriaga_Jr Pƙed 3 měsĂ­ci

    Kahit papaano ok na sana ang cross section ng biga pero pagdating ng bakal sa tension area ay 2-12 at 2-16 medyo compromised yata lalo na ang span mo ay 5m.

  • @mawkishrich3851
    @mawkishrich3851 Pƙed 2 lety +6

    Sir, we are building a 2-storey house and the schedule of columns are 4 (16 mm steel bars) and 2 (12 mm steel brs), the schedule of beam is 4 (16 mm)?is that okay? The steel.of.the beam used are heavier than the columns?

  • @ramisesumali1119
    @ramisesumali1119 Pƙed 3 lety +1

    Thank you bro.

  • @rojeanmarklopez7023
    @rojeanmarklopez7023 Pƙed 2 lety

    Engr. Gud eve. Para sa unsupported na 5m na lenght ng biga . 20x30cm 4-16mm continues, 2-16mm extra bars. Pwede na po ba sa second floor na light materials lang na tubular at phenolic ?

  • @thehalllife9076
    @thehalllife9076 Pƙed 2 lety

    New subscriber here thank you for your detailed videos

  • @raymondomuk4806
    @raymondomuk4806 Pƙed 3 lety

    Tnx Sir very informative ginagawa nyo more power

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety

      thanks for watching sir and have a great day.

  • @stereotype4102
    @stereotype4102 Pƙed 2 měsĂ­ci

    Ask ko lng po as a fresh grad and a new licensed. Di ba engr ang min. Depth ng beam if simply supported ay L/16 Base po sa nscp?

  • @reiden4442
    @reiden4442 Pƙed 3 lety +1

    Sir, request po sa solid slab.

  • @markanthonylazaro5248
    @markanthonylazaro5248 Pƙed 3 lety

    Ty engr. Romano it helps a lot

  • @NenethGarments
    @NenethGarments Pƙed 2 měsĂ­ci

    Sir anu po ang sukat at luwang ng beam at footing para sa 3 storey house

  • @junjietrawon9151
    @junjietrawon9151 Pƙed 3 lety

    Sir request lang po paturo kame pagawa ng structural analysis sa bldg permit ung basic lang

  • @Naspi_tv
    @Naspi_tv Pƙed 3 lety +2

    Idol ano ba tamang sukat ng bakal sa ibabaw ng steel deck sa slab? At ano po ang distances ? Thank you idol!

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety

      may video upload po aq ng detail nyan sir

  • @teamceiso1829
    @teamceiso1829 Pƙed 3 lety +1

    maraming salamat po

  • @bangkagtv3872
    @bangkagtv3872 Pƙed rokem

    Thanks for the info sir.. tanong ko lng po.. 6x6 m po pagawa ko 2-storey po.. 3 m po pagitan ng poste pwede na po ba diretso po bakal.. ano po standard na bakal gamitin sa biga... thanks po..

  • @nongarellano515
    @nongarellano515 Pƙed 2 lety

    Engr.gabs tnks sa info.

  • @marvinampeloquio6305
    @marvinampeloquio6305 Pƙed rokem

    Gdmorng, sir gab, tanung ko lang po kung magkanu Ang kuntrata ng labor and material per square meter po

  • @albertoornedo2419
    @albertoornedo2419 Pƙed rokem

    Thank you so much po engineer

  • @gonzaloamoyo70
    @gonzaloamoyo70 Pƙed 2 lety

    Thank you po engr,,,

  • @jayosborn1573
    @jayosborn1573 Pƙed rokem

    Engeineer pwde n po grade 33 n bakal sa bungalow house 7x7 meter?sana po masagot,,solid subscriber,,salamat po

  • @fernandocruz52
    @fernandocruz52 Pƙed 3 lety

    Very imformative...👍👍👍👍👍

  • @josephcatubiganz3231
    @josephcatubiganz3231 Pƙed 2 měsĂ­ci

    Hi sir, tanong ko lang po halimbawa iba-iba ang distance ng mga poste like may 3meters meron din 4meters, ok lng ba iba2x size ng beam based don sa computation ng 3m at 4m? Or mas ok na e uniform lng lahat ng mga bega based don sa pinaka mataas na haba ng poste? Hehehe thank you po sa sagot. Amen! 😊

  • @virgilioreymatias8042
    @virgilioreymatias8042 Pƙed 2 lety

    Sir gud eve po kung Ang Gawin kung ilan Yung bakal SA itaas Yun na rin bakal SA ibaba di Po b mas ok

  • @bostondefranco5992
    @bostondefranco5992 Pƙed 3 lety +2

    ARCHITECT BAKA GAYAHIN NG MASON AT KARPINTERO NA ADVISE SA KANILA CONFIRN MUNA SA DIRECT ENGINEER ABOUT DOWEL SYSTEM PARA SA TENSILE STRENGTH

  • @Federico_Madriaga_Jr
    @Federico_Madriaga_Jr Pƙed 3 měsĂ­ci

    Pag 12mm diameter ang ginamit bakal baka di aprobahan ng municipal/city engr ang detail sir accrdg sa bldg code.

  • @roxycally-8187
    @roxycally-8187 Pƙed 8 měsĂ­ci

    Sir possible po ba ang 3.5meters to 3.8meters na ceiling height? Beam to beam po? From beam sa ibaba at beam sa itaas?

  • @sonnyfelipe689
    @sonnyfelipe689 Pƙed rokem

    Engr. Gab, pwede ba chanel beam gamitin Jan at ganun din sa poste? Paanu Po estimation nun Sir or sizes ng chanel up to 3rd floor?open floor napo Ang 3rd floor..thank you Po sa pagsagot

  • @user-wc6il5ow8g
    @user-wc6il5ow8g Pƙed 3 lety +2

    Sana meron rc stair reinforcement detail engineet.

  • @jcbriton
    @jcbriton Pƙed rokem

    _sir? ask ko lang po, yung L/4 susukatin sya sa dulo ng poste kung san magsisimula ang biga? hindi magsisimula pagsukat ng L/4 sa gitna ng poste?

  • @wearecartoonschannel6336
    @wearecartoonschannel6336 Pƙed 2 lety

    Engr.pwede ba magtusok ng bakal sa beam para kakapitan ng traces at mag welding,palalagyan ko kasi ng support traces sa ilalim ng slab

  • @ronniekawakami2547
    @ronniekawakami2547 Pƙed 2 lety +1

    hindi po lahat nang engineer ay maganda ang plano po at matibay may mga engineer din na marunong sa magic work pero kulang ang quality nang trabaho nila kaya humanap ka nang mapag katiwalaan talaga

  • @aledzbuilders
    @aledzbuilders Pƙed 2 lety

    Very informative vids

  • @melvinmeneses8746
    @melvinmeneses8746 Pƙed 2 lety +1

    Good day sir,pwede po ba magtanong po sa inyo. Paano po magiging bakal if ever ang beam schedule is left support 3-2 ,mid support 2-3, right support 3-2 sana po mapansin nyo po salamat po

  • @airsoftone5893
    @airsoftone5893 Pƙed rokem

    Hello sir, pwede ba magkabit/maglagay ng beam sa poste mismo para sa porch. Height ng column na kakabitan ay 3.2m then ang ikakabit na Beam ay para lang sa height na 2.5m na taas ng Porch(slab ang roof ng Porch). salamat

  • @matsmixvlogs
    @matsmixvlogs Pƙed 3 lety

    Tnx very educational

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety +1

      thanks and have a nice day sir

  • @raymondcollantesvlogs8316

    Very informative.

    • @GabsRomano
      @GabsRomano  Pƙed 2 lety +1

      Glad it was helpful! thanks for watching

  • @rolanddelacruz8618
    @rolanddelacruz8618 Pƙed rokem

    Sir gabs,khit anong haba ba ng beam L/4 ang sukat at lhat ba klangan my midspan? Tnx

  • @romeoduldulao9228
    @romeoduldulao9228 Pƙed 3 lety +1

    Sir i suggest you discuss NSCP 2015 sa minimum amt of steel reinforcement for both longitudinal and transverse reinforcement with consideration to the effects of seismic loads aside from dead and live loads

    • @bethzarin6439
      @bethzarin6439 Pƙed 2 lety +6

      Gets ko na ang punto mo. Lowkey karin eh. Code of Rule of Thumb, Practical Design and Effective Site Classic Engineers Design tawag dyan. No need codes, basta safe ang compute sa analysis or at least sa common sense analysis.. sabihin nating 2 pcs 12mm is almost the same MPa sa 20mm parang ganun lng yan idol..
      Yung style ni Gabs is safe yan, more of analytic design ang style at hindi basta sa codes naka based. Pag libro, pang newbie lng yan. Pag Pro, either rule of thumb pag small project or etabs gamit pag big project. if ano lalabas yun ang sagot. pero sa ganitong discussion pang ordinary people lng naman eto na madali maintindihan at least mas safe kesa wala. Kasi kung sa mga engineers na viewers, syempre alam nyo na yan at hindi para sa engineers etong vlog kundi para lng sa mga normal na tao na gusto matuto.

    • @bonifaciojamisola2738
      @bonifaciojamisola2738 Pƙed 2 lety +2

      Tama, pang masa Ang vlog ni sir gabs, ngunit very informative. tulad naming Hindi mga engr ordinariong tao at nag babalak mag patayo Ng sariling tahanan, at least informed kami or kahit magka IDEA man lang, Ng mapanatag Ang kalooban sa ipapatayong tahanan.
      God bless...

    • @leonardofetalvero6942
      @leonardofetalvero6942 Pƙed 10 měsĂ­ci

      totoo yan,kung aasa ka sa nscp,aisc at geo technical ay mas malalim.ang tama lang ay garantisado na yun tinuturo niya kesa sa nakaklito na nscp code sa libro.@@bonifaciojamisola2738

  • @KuyaShane
    @KuyaShane Pƙed 3 lety

    Question po.
    Regarding 5 meter na biga.
    D 16inch. B 12 inch.
    Panu po kung ang load sa ibabaw ay moving na SUV or Van? ( Parking lot )
    Ok parin po ba itong D 16inch and B 12 inch? Or need na mag adjust dahil moving weight na ang load ng biga. Thanks po.

  • @russelnuque7506
    @russelnuque7506 Pƙed 7 měsĂ­ci

    sir gab hinge ako idea 4x8 meters area pero secondfloor po cya anu po tama sukat ng poste sa slab at beam

  • @vicentedenticojr3173
    @vicentedenticojr3173 Pƙed 3 lety +1

    Nice one boss

  • @roelvicenteobaob6936
    @roelvicenteobaob6936 Pƙed 3 lety

    engr.,gusto ko sana mgtayo ng maliit n bahay pero ako ang gagawa..slamat more power!

  • @user-ds7yy9fk7c
    @user-ds7yy9fk7c Pƙed 5 měsĂ­ci

    Pwedi po ba nka hanger ang crank bar s top....pls answer me..thanks po..

  • @boysilong5514
    @boysilong5514 Pƙed rokem

    Engr paano mag lagay ng column footing na may existing column footing na kapitbahy

  • @adelaidaguanzon3443
    @adelaidaguanzon3443 Pƙed 3 lety

    Nagpagawa po ako ng planom para sa proposed 2-storey 8-door apt.. there 15 200mmx400mm posts and 7 200mmMagx200mm smaller posts.maglalagay po
    ng footing tie beam kc ang distance between post ranges

    • @adelaidaguanzon3443
      @adelaidaguanzon3443 Pƙed 3 lety

      (continuation- Adelaida Guanzon)
      from 3.7m to 4.2m. Ito po yong malaking poste. FTB size is 300mm x 500 mm using 20 mm deformed bar. The apt is 2 floors with provision for 3rd floor. Walang roofdeck. Question: di po kaya masyadong malaki FTBs. Ok lang po kung kailangan pero baka po magkaroon ng excess or useless protection from buckling and maintaining slenderness of column and of course, unnecessary costs of materials. We've relayed the question to our Architect but he said it is necessary to ensure strength of structure at ito na raw po modern way.

    • @adelaidaguanzon3443
      @adelaidaguanzon3443 Pƙed 3 lety

      (Continuation-Adelaida)
      Ang main df po bawat poste are 6 pcs each side or 12 pcs for 2 sides of 16mm excluding other bars.

    • @GabsRomano
      @GabsRomano  Pƙed 3 lety

      ung slenderness ratio po is more about the unsupported distance of column, I think may reason po or other considerations kaya ganun ung size ng ftb mam.

  • @hersheylino8195
    @hersheylino8195 Pƙed 2 lety

    hello po.. magtatanong lang po kung ok lang ba ang magtiktik ng poste para makapaglagay mg floor level tie beam kapag hindi nkapag abang ng bakal sa poste?10x10 po size mg poste.. mga 2 incges po ang klamgan yiktikin para lumabas ang bakal sa poste

  • @yshan7851
    @yshan7851 Pƙed rokem

    Parang ang haba naman po ata ng depth na 5m? may ganon po ba talagang depth ng beam sa mga residential?

  • @roneldemagiba1563
    @roneldemagiba1563 Pƙed 2 lety

    Galing mo sir Gab

  • @user-ci3sm9rg7b
    @user-ci3sm9rg7b Pƙed 7 měsĂ­ci

    Sir, paano layout ang bakal? ang sukat ei 700mx350m, diba ang haba lng ng bakal ay 6m?

  • @johnsalac4116
    @johnsalac4116 Pƙed 3 lety

    Maraming salamat po sir sa kaalaman.. nagsubscribe napo ako maganda po pagpapaliwanag nyo..salamat po ult

  • @LouiseCabahug-tl5bq
    @LouiseCabahug-tl5bq Pƙed rokem

    Good morning sir safe po ba 12 by 12 inches ang column at ang steel reenforcement 4 16mm at 4 12mm Safe po ba ito

  • @lifetravelsportv3031
    @lifetravelsportv3031 Pƙed 4 měsĂ­ci

    Sir ang 2 storey house nilalagyan pa ba ng roof beam?