  • ADPRW : MODBUS Communication Instruction
    This instruction allows the MODBUS Master to communicate (read/write data) with the Slaves.
    ---------------------------------------------------------------------------------------------------------------------------------------------------------------
    Program Sample At:
    automationsolu...
    automationsolu...
    Download Sample Section
    ---------------------------------------------------------------------------------------------------------------------------------------------------------------

Komentáře • 25

  • @AAAAAA-ny4ib
    @AAAAAA-ny4ib Před rokem

    Hello! I send a data packet "slave func data srs16", but the result is this signal "00 slave func data srs16". Why do two zeros appear? ModbusRTU

  • @v.fig.3683
    @v.fig.3683 Před 4 lety

    Thanks my friend...

  • @almightyjovi3906
    @almightyjovi3906 Před rokem

    what instructions and modules if using QCPU if using communication via modbus

  • @kandarpmathane8896
    @kandarpmathane8896 Před 3 lety

    What is icvk & ivdr instructions? Can you make a video about it? Your channel is so helpful. Thanks

    • @Technocrats91
      @Technocrats91  Před 3 lety

      these instruction are for Freqrol communication with VFD

  • @thuangia9214
    @thuangia9214 Před 3 lety

    Can you please explain me about H1 (K13 H1 D100 M10)

  • @sonukushwaha7977
    @sonukushwaha7977 Před 2 lety

    what is H1, H3, H10 .......WHY USE THIS ( H1, H3 , H10 ) DIFFERENT IN EVRY LINE PLS COMMENT

  • @pratikpandit2026
    @pratikpandit2026 Před 4 lety

    Pr.117 is used as 2 and in program it is k1 whether it is correct slave address

    • @Technocrats91
      @Technocrats91  Před 4 lety

      The slave address is used as 1, Pr 117 must be 1 in this program

  • @thuangia9214
    @thuangia9214 Před 3 lety

    Can you please explain me about H3 (K200 H3 D110 M30). THANKS

    • @truemanautomation4433
      @truemanautomation4433 Před 2 lety +1

      H3 (holding register) k200 is reading actual register last 3 digt of ( 40200) d110 that reading values move to d110 m30 this is bit for after received datas

  • @rinkuanjusiddharth2514
    @rinkuanjusiddharth2514 Před 11 měsíci

    Sir please ek video fx5 Rs232adp par bando

  • @subashstreakz4805
    @subashstreakz4805 Před 3 lety

    Did u have manual for vfd modbus address?

  • @vasus7244
    @vasus7244 Před 3 lety

    How to connect to delta drive and fx 5u

    • @Technocrats91
      @Technocrats91  Před 3 lety +1

      Same method just modbus address will differ

  • @user-br8by4yw4c
    @user-br8by4yw4c Před 4 lety

    Hi
    If connection between two plc what is modbus address for (d0, m0, y0) in slave

    • @Technocrats91
      @Technocrats91  Před 4 lety +1

      In Fx5u there is a setting for modbus device assignment

    • @user-br8by4yw4c
      @user-br8by4yw4c Před 4 lety

      @@Technocrats91
      How i can set this adresses?

    • @Technocrats91
      @Technocrats91  Před 4 lety +1

      Go to rs485 setting in fx5u plc
      Open modbus device assignment

    • @user-br8by4yw4c
      @user-br8by4yw4c Před 4 lety

      @@Technocrats91
      Can i use simulator to test that?

    • @Technocrats91
      @Technocrats91  Před 4 lety +1

      No not in simulator mode

  • @miguel4606
    @miguel4606 Před 4 lety

    Im new to Mitsubishi, why K13??

    • @Technocrats91
      @Technocrats91  Před 4 lety +1

      That is Modbus address for Set Running Freq(40013)