Installing a UV Light and Air Treatment System in an HVAC Unit! STEP BY STEP

Sdílet
Vložit
  • čas přidán 1. 06. 2024
  • In this HVAC Training Video, I Explain How the UV Light and Air Treatment Works and How to Install It Step by Step. I Show the Installation in Sheet Metal Ductwork and in Fiber Board Duct. I Show How to Power both the 120v model and the 24v model. I also Explain Mounting Locations on a Furnace and an AC A-coil and N-coil as well as on an Air Handler. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    www.freshaireuv.com/apco-x/
    APCO-X Single lamp 24v model: TUV-APCOX-ER3
    APCO-X Two lamp 24v model: TUV-APCOX-DER3
    APCO-X Single lamp 110v to 277v model: TUV-APCOX-SI3-P
    APCO-X Two lamp 110v to 277v model: TUV-APCOX-DI3P
    APCO-X advantages
    -Unit has lifetime parts warranty except UVC lamp has 3 year warranty
    -The UVC is non-ozone emitting
    -The UVC and lifetime activated carbon catalyst treats microorganisms, odors and VOCs
    -Available in an 18-32V and 110-277V plug-&-play models
    -Available in single and two light versions
    -Lifetime warranty. 3 year UVC lamp
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.com/show/74KXLz5...
    Apple Podcasts: podcasts.apple.com/us/podcast...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #unvlight #airhandler #uv #light #airflow #airtreatment #ductwork #sheetmetal
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Komentáře • 158

  • @stroodles42
    @stroodles42 Před 2 lety +2

    You win the award for best music for an HVAC CZcams channel

  • @vernroach3413
    @vernroach3413 Před 2 lety +23

    Some guys, like myself, often wire the light power source to the EAC "Electronic Air Filter terminal", on the brain board, thats Hot L1 voltage and the common or neutral line return, also on the brain board.....Light comes on, only if the blower is on...Good video.

    • @donsturtevant2396
      @donsturtevant2396 Před 2 lety +1

      Yeah but he said the light is controlled by the exterior on/off light switch and when the switch is on, the UV light will stay on 24/7…so you’re wiring is wrong

    • @vernroach3413
      @vernroach3413 Před 2 lety +11

      @@donsturtevant2396... Why would you have it on 27/7 if the blower is not running?...DUH...If hooked up to the EAC terminal it turns on when the blower turns on, either heating of cooling and only when the blower turns on...Why leave the lights burning while no air is moving and they're doing nothing...Do you leave your house lights on 24/7 or only when you need them...If you don't know how to do it, then don't...Just plug it in and let them lights burn and burn out...Leave all your lights on, but I'm thinking, in some cases, like yours, the lights are on, but no one is home.

    • @mitchc1263
      @mitchc1263 Před 2 lety +5

      @@vernroach3413 Hey Vern, you would keep the light on to bake the coil 24/7 and keep it germ free.

    • @vernonroach918
      @vernonroach918 Před 2 lety +4

      You have the light close enough to bake the coil, kiss it goodbye...UV light can be harmful to many materials, especially with constant exposer over time...On 24/7 accomplishes nothing without air movement, other than shorter life of the bulbs and wasted electric...The unit is made to clean and sanitize the air, not the coil...Stay safe and Lets go Brandon.

    • @mitchc1263
      @mitchc1263 Před 2 lety +1

      @@vernonroach918 that's why we quit selling them... destroys flex duct and probably evap. Insulation... and yes let's go Brandon

  • @warrenstaben6166
    @warrenstaben6166 Před 2 lety +9

    Craig, so glad I found this channel. Great videos, no fillers, no bs, to the point and the best part fantastic music at the right volume and time. Well done sir!!!

  • @jimmysegovia2688
    @jimmysegovia2688 Před 2 lety +1

    the king of ac!!!! awesome video Craig thank you for sharing!!!!! you are the best man!!!!!.

  • @kmadrid2325
    @kmadrid2325 Před 11 měsíci +1

    What a quality video! Thorough, yet concise, right on the money. So helpful!

  • @ishalljr
    @ishalljr Před 2 lety +2

    Nice! Please do a video on the dual set up for the air handler. Thanks.

  • @Sonicrick66
    @Sonicrick66 Před 2 lety

    Very Nice tyty. I understood before i saw video where the wire be connected to unit but wanted watch a Video showing to be 1000% sure. like always great videos tutorials.

  • @scsclassics
    @scsclassics Před 2 lety +1

    Good work ! . You should show how to install a media filter box and filter next .Honeywell , carrier , Lennox ….ext. I just bought a Reme halo led and can’t wait to install it .

  • @jaguilar11009
    @jaguilar11009 Před 2 lety

    Thanks for all your videos, they are very helpful, I will sign up for heating and air conditioning school good 👍 job thanks again 👏👏

  • @richardweidner1625
    @richardweidner1625 Před 3 měsíci

    thanks for the mandatory minor key, four on the floor rock music during install

  • @Reedgains
    @Reedgains Před 7 měsíci

    Super high quality video. Thank you.

  • @a11ten071
    @a11ten071 Před 2 lety

    Great Job as always sir TNX a bunch!

  • @darnellfisher4148
    @darnellfisher4148 Před 2 lety

    Thanks for the video!

  • @baderaltamimi87
    @baderaltamimi87 Před 2 lety

    You are the man! Can't thank you enough.

  • @tunaman2200
    @tunaman2200 Před 2 lety

    Excellent! Thank you

  • @heatncool
    @heatncool Před 2 lety

    Very educational and helpful

  • @petekane2501
    @petekane2501 Před 2 lety

    Great information & review

  • @georgecartwright5184
    @georgecartwright5184 Před 2 lety +1

    These are great videos and very helpful. Thank you for them.

  • @fergify1989
    @fergify1989 Před 8 měsíci

    Great video, Im trying to install a second UV light but I am unsure how to wire the Packard multi tap. Do you have a video or would be able to help with wiring?

  • @toolemanful
    @toolemanful Před 2 lety

    Great video!!!! I there a video on installing a large bypass humidifier

  • @Rocket3576
    @Rocket3576 Před rokem

    Great video! Have you heard of the Jumper King from Supco? It would be cool if you did a demo video on that tool.👍

  • @firstbadboy1
    @firstbadboy1 Před rokem

    Hi there. Thank you for sharing all your knowledge to us. I'm trying install a uv light to my system but I'm not clear on the power connection, you're saying one end on 24v R and the other on Common, I'm I right?

  • @logmeindog
    @logmeindog Před 2 lety +2

    I always wonder how that small amount of activated carbon will do any appreciable good. The same goes with those thin activated carbon sheets you can slap over a filter. From what I gather, commercial installations use large canisters with 10's of lbs. of activated carbon.

  • @Rojs011
    @Rojs011 Před 9 měsíci

    ⁠ Thanks for the video. Made me start the research best light for my system. But I have a question, is it true that uv light is bad for plastic and can damage the drain pan?​​⁠ ​​⁠

  • @OthmanAlikhan
    @OthmanAlikhan Před 2 lety

    Thanks for the video =)

  • @MegaRisenshine
    @MegaRisenshine Před rokem

    Great video thanks for sharing… I just have heating furnace Ultr v tech 80…. Where to I installed the uv light??

  • @jaguilar11009
    @jaguilar11009 Před 2 lety

    Please can you ,make a video of what is the proper way , to check the furnace before we use it, in the winter, I will be grateful for it thanks 👍👏👏👏

  • @Damian-ir8gn
    @Damian-ir8gn Před 2 lety +1

    Thk I'm only three months in and furnace season kicking my ass

  • @chesstime356
    @chesstime356 Před 2 lety

    Very nice thank you

  • @hoopie1022
    @hoopie1022 Před 2 lety

    Thank you !

  • @joemartinez7765
    @joemartinez7765 Před 2 lety

    How would you install one on a modular home down flow furnace with ac coil ??
    Thank you.

  • @SmokyRibsBBQ
    @SmokyRibsBBQ Před 4 měsíci

    I'm interested in putting this in my system. The only question I have is does running in heat mode affect or damage the light? My evaporator is above my heat exchangers like the unit you have in the video.

  • @NorCal-refrigeration
    @NorCal-refrigeration Před 2 lety

    Craig just got this video and I’m subscribed. CZcams is glitching or something. I’ve had other content makers going through this as well.

    • @acservicetechchannel
      @acservicetechchannel  Před 2 lety +1

      Yeah it is odd. CZcams is not acting like it used to in reference to algorithms, home screen, and up next, even when the notification bell is selected. It is always changing! Thanks for letting me know Dave! I hope all is well! Keep doing what you are doing! You're a great guy to follow and learn from for those who are hungry and seeking real world knowledge and skills!

  • @michaelsera746
    @michaelsera746 Před rokem

    Hello, Does the UV deteriorate the Fibrous Acoil insulation on the side walls. Also, Is a superior location inside the A(coil) ? Thx Much.

  • @frontiermarvin71
    @frontiermarvin71 Před 2 lety

    Exactly what I need it ! Thank you .

  • @angelofonseca8452
    @angelofonseca8452 Před rokem

    Hello,
    Does the uv light deteriorate the insulated lining?

  • @PubliusHadrianus
    @PubliusHadrianus Před 2 lety +19

    nice tips, but i had some "oh, no, you're doing it wrong" moments, because handling the lamp without gloves and leaving fingerprints on it will actually shorten its life span. This is because oil in the greasy fingerprints will degrade over time and darken the lamp surface, it can even cause cracks in the quartz glass - the effect is the same as with halogen quartz light bulbs.

    • @sctony3
      @sctony3 Před 2 lety +9

      Unlike most other manufacturers lamps Fresh-Aire UV lamps can be handled when not lit. This is because they are made using high-quality hard quartz not the soft quartz found in inexpensive imports (handling soft quartz lamps may cause them to fail).

    • @joshl3323
      @joshl3323 Před rokem

      I was i aware to put it in the supply. I believed it always went into the return to reduce o3

  • @wowmenso
    @wowmenso Před rokem

    Nice info

  • @Sandwebbspider
    @Sandwebbspider Před 2 lety

    Craig , is it ok to touch the bulb with your fingers ?

  • @RC-Heli835
    @RC-Heli835 Před 3 měsíci

    I have a flat coil!
    Should the light go on the in or out side?

  • @jarbarian
    @jarbarian Před 6 měsíci

    There is APCO and APCO-X. On Amazon I only see the APCO. Is that sufficient for a single level 3000 sq ft home? Also, would I need one for the air handler and the condenser?

  • @7HEREALDON
    @7HEREALDON Před 6 měsíci

    Moved into a new build and started to notice a musty smell, company builder used to install HVAC came out twice and found no issues, both times the smells came back after a few days. Third visit they replaced the coils and cleaned the pan, I can still slightly smell it.
    I wanted to get a reme halo, but I've been getting conflicting feedback about it. Any advice? (I'm in need of clean air as I'm trying to regain my health from living in hidden mold)

  • @stickybandit2346
    @stickybandit2346 Před rokem

    There's pipes in the way on mine, but could I put it a foot higher?

  • @deanmartin1966
    @deanmartin1966 Před 2 lety

    Great video Craig.

  • @amio_roseto1
    @amio_roseto1 Před 2 lety +1

    great video, will this lamp also work well on Oil Burner furnaces with a hvac Coil ?

  • @erikizquierdo7130
    @erikizquierdo7130 Před rokem

    I had a question did you Pig tail the common wire to the c terminal couldn’t you just put the common wire in the c terminal on the board instead of putting a wire nut ?

  • @tphvac87
    @tphvac87 Před 2 lety

    How do you feel about air scrubbers?

  • @andresdelgado5698
    @andresdelgado5698 Před 2 lety +1

    Craig, thanks for the exceptional video. I’m seriously considering an APCO X for my new 5 ton Heat Pump. The AHU will come with 10KW of emergency heat/strip heating. Will that impact my APCO X installation. I checked Fresh-Aire UV’s website for additional installation information but did not find anything. Thanks again.

    • @ronasaunders
      @ronasaunders Před 2 lety

      Andres, the APCO-X was designed and built in Jupiter, FL with plenty of heat strips/air handlers. The ceramic base, the hard quartz lamp, and the activated carbon cells can withstand any heat generated from the heat strip.

  • @LEARNPROJECTMANAGEMENT

    Thanks so much Craig . Is it safe to connect the UV light electricity to the unit R and C .? Does the UV affect the AC unit life time or create any fire ?

    • @MrBababuwi
      @MrBababuwi Před 2 lety

      As long as you dont overload the transformer, it is safe. However, it is crucial you check the transformer capacity before connecting to R&C, otherwise a dedicate power supply should be used.

  • @arthurwilliams4160
    @arthurwilliams4160 Před 2 lety

    Please put more install videos Thanks

  • @jasonbengel
    @jasonbengel Před rokem

    Great info! I searched the thread, but didn't see anyone mention how UV can accelerate "photo-corrosion" of aluminum (for the duct work). I'm curious if the UV light should be placed in any particular location -- I imagine boring duct work with no electronics would be fine to be exposed to UV, but wiring and/or an evap coil might be bad around UV? I've found a few papers that discuss photo-corrosion by UV and aluminum is apparently higher on the list.

    • @bartwilliams4478
      @bartwilliams4478 Před rokem +1

      I just added a honeywell UV lamp in my goodman airhandler, The goodman handler has a knock out for UV and the V shaped evaporator has a knock out that places the uv dead center of the inside v shape which happened to be inverted in my application and is just above the airfilter so filter air is drawn through a filter then uv then evap then blower. The goodman knockout was 1/4 inch to small for the Honeywell mounting but larger enough for the lamp going into the evaporator assembly.

    • @bartwilliams4478
      @bartwilliams4478 Před rokem

      Looking up UV corrosion it seems that most testing was done under aqueous conditions not open air and was specific to aluminum specific alloys, I suspect the loss would be minimal otherwise HVAC manufacturers would have already changed the metallurgy of the materials had there been significant damage from UV

  • @jkbrown5496
    @jkbrown5496 Před 2 lety +3

    Another reason to put these on the supply side is it is far more likely to kill the biologics in the drier, dehumidified air where there is less water vapor in the way. Also, any biologics in larger water droplets will have condensed out with the water and ran down the drain.

    • @PIndyJones
      @PIndyJones Před rokem

      That explains the shit that gets stuck in there that looks like snot

  • @bigbite9804
    @bigbite9804 Před 2 lety +2

    For best result...
    UV light before installation. We have to check the air quality. And we need to check the air quality again after the installation of the UV light. In this way we can find the difference in whether it is working or not. I did the same thing a year ago in Dubai

  • @Twoface0233
    @Twoface0233 Před 2 lety

    Craig, are you involved in new construction by any chance?

  • @leestebbins5051
    @leestebbins5051 Před rokem

    What is a ballpark figure for an installation?

  • @nilborne1
    @nilborne1 Před 2 lety +1

    Will the UV light deteriorate insulation in equipment cabinet? I have seen uv light ruin filters.

    • @RandysMixtable
      @RandysMixtable Před 2 lety +1

      It will dry rot and strip the shielding on any and all wires within the system, none of them are rated or sunlight.

    • @ronasaunders
      @ronasaunders Před 2 lety +1

      All equipment from 2005 has UVC inhibitors in it. APCO-X is residential, and some contractors install commercial UVC, which will create these problems. Stick with products that are designed for residential applications.

  • @geoffreyhoffman2739
    @geoffreyhoffman2739 Před 2 lety

    I got quoted $1,200 to install one of these, Mesa AZ. Is that normal?

  • @andysmith9785
    @andysmith9785 Před 2 lety +1

    How long does this last and how often do you change bulb

    • @ronasaunders
      @ronasaunders Před 2 lety +2

      Lifetime on ALL parts, including the carbon cells....Lamp is 3 years guaranteed

  • @ptaweston
    @ptaweston Před 2 lety +2

    Why do you need a dual version for an air handler? All of the air has to pass through the top part. No? What am I missing? Thank you!

    • @zclarkeman
      @zclarkeman Před 2 lety +1

      Well, the air is cleaned but the light isnt going to hit the coil without the other lamp being at the bottom.

    • @donsturtevant2396
      @donsturtevant2396 Před 2 lety +1

      You need to watch the video again and this time listen. The light needs to cover all exhaust sides of the A-coil core. It’s function is to kill growth on the A-coil and should be on 24/7

  • @butlerstouchHVAC
    @butlerstouchHVAC Před 11 měsíci

    what sheet metal cutter is that? please reply

  • @jerrygrayson8421
    @jerrygrayson8421 Před rokem

    I now have above A coil a humidifier thus I am told UV will degrade plastic frame of humidifier. Still I want uv light reaching A coil. Please make suggestions. I now have UV light in out flow plenum four feet from coil.

  • @rando_webb8704
    @rando_webb8704 Před 2 lety

    Been there done that, but my company uses the REME Halo.

    • @ronasaunders
      @ronasaunders Před 2 lety

      The APCO-X offers a Lifetimer Performance Guarantee. and the Carbon cells last forever without having to be cleaned every 3 months, like the product you sell

  • @johnspitta6725
    @johnspitta6725 Před rokem +2

    Our HVAC peeps just installed this in our plenum in our condo. I can actually see two vents glowing blue. Not the light bulb directly but blue light. I guess, indirectly. Is that a problem?

    • @grglyzen
      @grglyzen Před 10 měsíci

      This is what I'm also trying to figure out. Would also like to know of it is safe to replace the air filter while the uv light is shining on it from above. Is it safe to look at the air filter while uv light is being shined on it?

  • @dfigueroa903
    @dfigueroa903 Před 2 lety

    Can you install this in a furance supplying only heat only

    • @ronasaunders
      @ronasaunders Před 2 lety

      You can, but be sure to move air across all filters/uvlights/carbon to help with air quality when no calls for heat come in.

  • @briancarlton9973
    @briancarlton9973 Před 2 lety +3

    Do those things really work with 1/2 second exposure to the air passing through?

    • @easkeybikes1966
      @easkeybikes1966 Před 2 lety +1

      That's why they work best with a snake oil injector on the return side.

    • @briancarlton9973
      @briancarlton9973 Před 2 lety

      @@easkeybikes1966 lol, I have 2 of em trying to sell, didn't install em.

    • @paulh3973
      @paulh3973 Před 2 lety

      UV light will deteriorate anything it touches over a period of time. Wiring, insulation, anything plastic, etc. It will also build up a white slag on the metal. I wouldn’t install one based on what I’ve seen long term.

    • @caseyroberts9522
      @caseyroberts9522 Před 2 lety +1

      No

    • @nsudatta-roy8154
      @nsudatta-roy8154 Před 2 lety

      @@paulh3973 It makes a good up sell due to cv19 though. You should be able to sell a shit ton of these to businesses.

  • @norb231
    @norb231 Před rokem

    Why does the lamp have to be on 24 hrs a day? Not only when the fan runs?

  • @tomman1718
    @tomman1718 Před 2 lety

    why is it necessary the light runs 24/7?

  • @KINGPAFA
    @KINGPAFA Před 2 lety

    Thanks, I only work on Refrigeration equipment but I always watch your videos, It would be nice if you could make another video on pressure switches and explain it a bit more, I think the previous video on pressure switches was a bit short! Thanks again and God Bless.

  • @sharmahw
    @sharmahw Před 5 měsíci

    Hello Craig. I tried to reach you re getting FreshaireUV installed in NJ. I can't find a contact number on your website. I emailed on the address listed but never heard back. If you don't do installs can you please recommend someone in Somerset NJ area?
    Do any other viewers of this channel know a FreshaireUV installer in central NJ area? I need to install in 2 homes. Thanks much all.

    • @acservicetechchannel
      @acservicetechchannel  Před 5 měsíci

      We are only doing the HVACR education and don't know of contractors in that location, sorry.

  • @varandavakian
    @varandavakian Před 2 lety

    👌🏼👌🏼👌🏼👌🏼

  • @stephwaylonwells3218
    @stephwaylonwells3218 Před 2 lety

    👍

  • @zclarkeman
    @zclarkeman Před 2 lety +2

    I wish you would have connected it to the additional transformer you had to show us how that worked. Ive always been told to add a transformer on these just incase.

    • @ronasaunders
      @ronasaunders Před 2 lety

      The 24vac does pull 16va...so it may be necessary to upgrade or provide a secondary transformer.

  • @RandysMixtable
    @RandysMixtable Před 2 lety +1

    Side note, don't install these where the uv light will hit any sort of wiring inside the system or by blower, just had a system pop a breaker because the uv light stripped away the shielding on the high voltage wires.

    • @hvacpartspros9275
      @hvacpartspros9275 Před 2 lety

      You can purchase UV coating UV protectant wire chases it’s very in expensive a box of 50 or 100 feet is probably 30 bucks

    • @ronasaunders
      @ronasaunders Před 2 lety

      All equipment from 2005 has UVC inhibitors in it. APCO-X is residential, and some contractors install commercial UVC, which will create these problems. Stick with products that are designed for residential applications.

  • @Review-This
    @Review-This Před 2 lety +1

    Why not run it on the 24V green so that the customer can run it with the blower fan on or fan circulate so that way the UV isn’t always on consistently?
    I know with the ozone cells if it’s on consistently the ozone will build up in the Plenum boxe and over whelm the customer with a hydrogen Peroxide type smell.

    • @Froggability
      @Froggability Před 2 lety

      Agree. The lamp has life span of so many hours, customer never notice if the lamp died

    • @jkbrown5496
      @jkbrown5496 Před 2 lety +4

      @@Froggability Actually, discharge lamps are limited by on/off cycles. It is the startup that is hard on them.

    • @scotts4125
      @scotts4125 Před 2 lety +2

      Manufacturer recommends light stays on 24/7. Bulbs are rated how long they last based on 24/7 usage. Mine are the highest rated they offer and will last 3 years. My above post will tell why I was skeptical about these and became a believer. I set a reminder in my phone plus wrote the install date on the sticker they give you to replace the bulbs. If you are changing the filter every month you should be seeing the sticker on the A/H.

    • @michaelengel9162
      @michaelengel9162 Před 2 lety +1

      Mold grows 24/7 and on/off shortens the life of the bulb. APCO-X is ozone free and H2O2 free so those "products" require to cycle on/off with blower. The only biproduct of APCO-X is clean air

    • @ronasaunders
      @ronasaunders Před 2 lety

      @@jkbrown5496 YES!

  • @chada472
    @chada472 Před 11 měsíci

    Big air flow restriction!

  • @PhillipDonohue
    @PhillipDonohue Před rokem

    wheres the package units?

  • @scotts4125
    @scotts4125 Před 2 lety

    I have two of the dual units in my 2 systems. I had a really dirty coil on a 1 year old house. The installers put the filter in the stand the A/H sits on instead of the filter slot inside the A/H. The stand was open on 2 sides. Coil was a mess. Cleaned the coil with NuCalgon and installed the dual Apco's. I got the coil fairly clean but it wasn't 100%. Less then a week after the install and the filter in the correct place, the coil was spotless. It has been spotless ever since. I'm not sure if the black stuff was mold or just wet dirt but the light got rid of it 100%. I was a bit skeptical but I also wanted to be as safe as possible from the rona. I am sold on these. The sightglass is really not needed as you can see the bluelight on the part of the Apco that is attached to the duct. They have different levels of lights that go by how many years they last. I opted for the 3 year. In 3 years I will need to buy 4 lights. I have the main unit mounted pretty much like in the video but in ductboard. For the second light it's just the wire coming from the main unit to the bulb holder. They provide a magnet for the second light. I put mine in between the A coil. I also installed a transformer for each unit just for the lights. I don't have electrical outlets in the A/C closets. I wago'ed line voltage off the OEM transformer for the second transformer. Install is very easy.

  • @Review-This
    @Review-This Před 2 lety

    The Reme Halo LED is so much better.
    In my opinion

    • @ronasaunders
      @ronasaunders Před 2 lety

      Be sure you ask them for their studies....the original protocol. I think you'll find many products are tested in a shoebox. And the APCO-X is guaranteed for life, with just a 3 year lamp replacement required. Does your IAQ product offer that guarantee to you and your customers?

  • @UnconsciousCompetence
    @UnconsciousCompetence Před 2 lety +1

    Installing a UV light inside the air handler cabinet seems like poor practice to me. I have seen several cases of a UV light inside an air handler cabinet breaking down the electrical wire insulation. The wire insulation eventually turns into powdery whitish dust. Prolonged UV exposure is no joke!

    • @revealingfacts4all
      @revealingfacts4all Před 2 lety +3

      Agree. It also breaks down the drain pan. The bulbs are expensive to replace too. And in all my years, I just never seen where this was even necessary to install.

    • @ronasaunders
      @ronasaunders Před 2 lety

      It is true, you are turning your customers air handler into a disinfecting device, so be sure to follow the manufacturers recommendations in the manual.

    • @ronasaunders
      @ronasaunders Před 2 lety

      @@revealingfacts4all If you consider portable air purifiers with 5 cfm blowers cost $3-500 each, and cover a 10x10 room, a whole house system is a no brainer for you and your customer. And these lamps last 3 years, guaranteed. The whole APCO-X offers a Lifetime Performance Guarantee. Just install it per the manufacturers specs.

  • @DaiPheo
    @DaiPheo Před 2 lety

    *Chào bạn,Mình đến từ Việt Nam,cũng làm nghề điện tử,điện lạnh,mong dk giao lưu học hỏi các bạn*

    • @Blockdagdaddy
      @Blockdagdaddy Před 2 lety

      Mine didn’t come with an insulation mounting kit. How should I mount it? I really need it in the insulation above the coils ?

  • @techfive7202
    @techfive7202 Před 2 lety +4

    Cant emphasize enough not to look at that light more than a second. Not even that if you can avoid it. It'll burn your eyes and you'll have thousands of tiny blisters on your eyeballs. When you blink it will pop the blisters. Your night will be absolutely miserable.

  • @NES088
    @NES088 Před 2 lety +1

    I heard that UV lights will shorten the life of plastic drain pans...

    • @Froggability
      @Froggability Před 2 lety

      Any plastic include cabling and paper labels

    • @ronasaunders
      @ronasaunders Před 2 lety

      All equipment from 2005 has UVC inhibitors in it. APCO-X is residential, and some contractors install commercial UVC, which will create these problems. Stick with products that are designed for residential applications.

  • @garza7676
    @garza7676 Před 2 lety +1

    Get video but the background music is super annoying . Tell your Audio guy to mute it . Thanx

  • @bryanleofarmore7697
    @bryanleofarmore7697 Před 2 lety

    Are you hiring sir? Or other company? Thanks

  • @darriendelossantos3958

    Jesus crisis he did that so manly

  • @realestateservicessaleshea99

    My only question is,how did we survive without all this crap?🤯
    🍺🍺🍺🥃🥃🍿🎯
    Stay safe.
    Retired (werk'n) keyboard super tech. Wear your safety glasses!

    • @roberts1159
      @roberts1159 Před 2 lety +3

      Just checked the cost for 120v unit, about $460. No thank you!

    • @wholeNwon
      @wholeNwon Před 2 lety

      Many didn't.

    • @srobeck77
      @srobeck77 Před 2 lety

      capt obvious guy: human lifespan has gone up 2-3x longer in past 100 years.

    • @realestateservicessaleshea99
      @realestateservicessaleshea99 Před 2 lety

      @@srobeck77 pal 🤣 there hasn't been that many uv lights sold in the last 100 years to contribute to any increase of life expectancy.
      🤣🥃🍺