004 | Learn BIT, BYTE, WORD, DOUBLE WORD Concept & Conversion in SIEMENS PLC | SITRAIN |

Sdílet
Vložit
  • čas přidán 29. 08. 2022
  • In summary, the BIT, BYTE, WORD, and DOUBLE WORD data types are essential concepts in Siemens PLC programming. Understanding the conversion rules for these data types is crucial to effectively program a Siemens PLC. By using the appropriate data types and conversion rules, we can efficiently control and read digital signals in our automation and control applications. As technology continues to advance, it is essential to stay updated with these concepts to remain competitive in the industry.
    ➡️ BIT
    A BIT is the smallest unit of data in a PLC. It can either have two states: ON or OFF. In Siemens PLC programming, we use the data type BOOL to represent a BIT. This data type can be used to control a single digital input or output.
    ➡️BYTE
    A BYTE is a group of 8 BITS. In Siemens PLC programming, we use the data type BYTE to represent a group of 8 digital inputs or outputs. The BYTE data type can be used to control or read 8 digital signals at once.
    ➡️WORD
    A WORD is a group of 16 BITS. In Siemens PLC programming, we use the data type WORD to represent a group of 16 digital inputs or outputs. The WORD data type can be used to control or read 16 digital signals at once.
    ➡️DOUBLE WORD
    A DOUBLE WORD is a group of 32 BITS. In Siemens PLC programming, we use the data type DWORD to represent a group of 32 digital inputs or outputs. The DWORD data type can be used to control or read 32 digital signals at once.
    ➡️Conversion
    In Siemens PLC programming, we may need to convert data from one data type to another. For example, we may need to convert a BYTE to a WORD, or a DWORD to a BYTE. In order to do this correctly, we must understand the process of conversion. The following are the conversion rules for BIT, BYTE, WORD, and DOUBLE WORD data types:
    - To convert a BYTE to a WORD, we need to concatenate two BYTEs.
    - To convert a BYTE to a DOUBLE WORD, we need to concatenate four BYTEs.
    - To convert a WORD to a DOUBLE WORD, we need to concatenate two WORDs.
    - To convert a WORD to a BYTE, we need to extract the high BYTE or low BYTE of the WORD.
    - To convert a DOUBLE WORD to a WORD, we need to extract the high WORD or low WORD of the DOUBLE WORD.
    - To convert a DOUBLE WORD to a BYTE, we need to extract the high BYTE, second high BYTE, third high BYTE, or low BYTE of the DOUBLE WORD.
    ➡️Practical use of Data Types
    In practice, we use these data types to control and read digital signals in automation and control applications. For example, in a manufacturing plant, we may use a Siemens PLC to control a conveyor belt. The PLC would use the data types to control the motors and read signals from sensors. When a product reaches a certain point, a sensor would send a signal to the PLC, which would then use the data types to control the motors to either stop or start the conveyor belt.
    ➡️Conclusion
    In summary, the BIT, BYTE, WORD, and DOUBLE WORD data types are essential concepts in Siemens PLC programming. Understanding the conversion rules for these data types is crucial to effectively program a Siemens PLC. By using the appropriate data types and conversion rules, we can efficiently control and read digital signals in our automation and control applications. As technology continues to advance, it is essential to stay updated with these concepts to remain competitive in the industry.