Gas training picture quiz on unsafe situations part 9.

Sdílet
Vložit
  • čas přidán 7. 09. 2024

Komentáře • 51

  • @andrewtomlinson18
    @andrewtomlinson18 Před 2 lety +9

    Loving the picture quiz, great way of topping up the memory bank, more please please

  • @timeyre9985
    @timeyre9985 Před měsícem

    VERY informative, caught me out on a few of those. thank you very much for the training.

  • @all4heatinggaslimited40
    @all4heatinggaslimited40 Před 2 lety +2

    Thank you Derek
    Your are always feeding up and brushing up our knowledges

  • @paulnixon4489
    @paulnixon4489 Před rokem +2

    I almost got 100 percent but you deffo stiffed me on the last one I noticed no sticker, but I'm calling spillage on the case and no controls. 😂. I. D.

    • @mohana.6185
      @mohana.6185 Před 10 měsíci

      Yeh case and above looks as if it has kind of spillage and controls

  • @madmaycon2531
    @madmaycon2531 Před 8 měsíci

    Your videos are perfect and very clear. Tomorrow I have my ACS - Practical Assessment, I hope everything goes well.. Thank you very much.🙏

    • @tomkatgastraining
      @tomkatgastraining  Před 8 měsíci +1

      Good luck with it and let me know how you get on 👍🏻

    • @madmaycon2531
      @madmaycon2531 Před 8 měsíci

      Yes, I'll definitely let you know..But I'm very confident and everything will be fine.👊🙏👊

  • @joeblogs1236
    @joeblogs1236 Před 10 měsíci

    As usual spot on!!!.

  • @lloydhocking3923
    @lloydhocking3923 Před 2 lety

    Best quiz so far, real life scenarios. Thanks

  • @moulesanctuary
    @moulesanctuary Před rokem

    Keep them coming ... great to swat up

  • @stabani6944
    @stabani6944 Před rokem

    Very helpful
    Great way to describe
    Loved it

  • @mcginn002
    @mcginn002 Před 2 lety

    Keep them coming Derek 👍👍

  • @johnward5006
    @johnward5006 Před 2 lety

    Love these quizzes, humed and ha on q 2 . Q 3 I went for AR. Keep them coming. Unsafe Situations, even with IGEM11 can be confusing/ mis diagnosed.

  • @robertyoung3140
    @robertyoung3140 Před 2 lety

    Brilliant bud. Thank you 😊

  • @fredthesavannahcat2899

    This is good. Keep em coming

  • @billybobhouse9559
    @billybobhouse9559 Před 2 lety

    This is awesome! More please. I did get some wrong.

  • @jockster5525
    @jockster5525 Před 2 lety

    Quality viewing mate 😉 thanks for your efforts 😊

  • @mrturner8755
    @mrturner8755 Před 2 lety

    Super helpful please keep doing your videos

  • @edmetcalfe8974
    @edmetcalfe8974 Před 2 lety

    Really enjoy your videos Derek. We’ve disagreed in the past and I got a long way through this one thinking I might agree with your every assessment.
    There are two I might, possibly quibble with. Overall we’re on the same page though. Top work mate.

  • @kevj1964
    @kevj1964 Před 2 lety

    Great Quiz Derek.

  • @jonessenoj6753
    @jonessenoj6753 Před 2 lety

    Great video 👍

  • @joshd790
    @joshd790 Před rokem

    Great video

  • @stevenmiller3784
    @stevenmiller3784 Před 2 lety

    Very enjoyable , the cooker knob thing is a bit grey, maybe remove another knob , purge and relight , observe flame picture etc
    Albeit the hob shown would be a candidate for the above lol

  • @mcDarkD
    @mcDarkD Před 2 lety +1

    6.46 not to right dimensions from back wall too, min 50mm(cant see the rest) and if someone did replace that cooker knob someones been there with a souring pad. guessing game.
    love your uplaods.
    8.30 i have one of them close to me. but its a glowworm or vaillant. i have thought about dropping off an old flue from a taken out boiler so they can maybe get it righ "next time". selfish i know. i just dont want gas safe inspector assuming i did that work.
    if i got all your questions right what do i win!!! i guess i failed though...................i never riddored anything.

  • @lj4434
    @lj4434 Před 9 měsíci

    Thanks alot

  • @joco5906
    @joco5906 Před rokem

    Hi Derek, great vids as always! regards the final example (the water heater). Should we not also be concerned about the positioning of the plug in relation to the hot gases exiting the flue and the control knob is missing - wasn't that I.D.?

  • @MindMechanicsIC
    @MindMechanicsIC Před 2 lety

    Great content on pretty much all videos, very helpful & informative. One suggestion, if possible, would be to link any downloadable documents for us to access.

  • @robincurwood
    @robincurwood Před 6 měsíci

    The final picture looks like it has soot marks on the casing. Surely makes it ID?

  • @muzzz33
    @muzzz33 Před 2 lety

    Number 9 would only be AR if it was not sealed internally and the flue was insecure . If it's just not cemented externally and no products entering then only NCS . Also the meter box one , most boxes of that type have the service and installation pipe work passing through that outer edge of the box but at the bottom, so how is it AR when it's at the top? . Are you suggesting there is a pathway for gas to enter the building when it passes through the top but not if it passes through the bottom as normal? This would be AR if it passes through the back of the box and not sealed allowing gas to potentially pass into the property .keep up the good work with these videos ,great resource for trainee's .

    • @tomkatgastraining
      @tomkatgastraining  Před 2 lety +1

      Number 9 is AR as the flue is not sealed and products of combustion could enter the cavity and the meter box one is AR as the integrity of the box is broken so it’s classed as like the door is missing.

  • @carlfisher5195
    @carlfisher5195 Před 2 lety

    If in doubt... ID it and put it right...!!

    • @tomkatgastraining
      @tomkatgastraining  Před 2 lety

      If it’s ID and riddor you will still need to report the riddor even if you fix it and what if you ID an NCS

  • @mervinpermalloo8589
    @mervinpermalloo8589 Před rokem

    🙏😊

  • @sebastiaandevries6428

    funny that some things are considdered worse in the netherlands and some not

  • @SuperWayneyb
    @SuperWayneyb Před 2 lety

    🤘😎🤘

  • @trevcam6892
    @trevcam6892 Před 2 lety

    I'm no gas engineer but in the thumb nail picture it seems to me that on the flue there should be a grommet to cover the hole to prevent CO ingress. I just took a gander at my boiler and there's no hole there at all. My service engineer puts the gas probe in the sampling port above when serving my boiler.

  • @marvindallen8916
    @marvindallen8916 Před 2 lety

    👍🏾

  • @mohana.6185
    @mohana.6185 Před 10 měsíci

    14 looks as if it has some spillage, am I wrong?

  • @mattylad8035
    @mattylad8035 Před 2 lety

    As a non RGI - What's ID? I understand RIDDOR. (I got several right).
    Is it Immediately Disconnect ?

  • @tonyadams380
    @tonyadams380 Před 2 lety +1

    Can't go with no.10! You can't ID and RIDDOR work that hasn't even been carried out. And what idiot would install it then RIDDOR their own work?

    • @tomkatgastraining
      @tomkatgastraining  Před 2 lety

      Don’t get you number 10 is the boiler that a builder has removed the walls around the boiler and is holding it up with wood and then has used a bit of rainwater pipe as a flue extensions. So you find the boiler the way of the picture so how’s that not ID and riddor

    • @tonyadams380
      @tonyadams380 Před 2 lety

      @@tomkatgastraining
      Yes I do now mate. Sorry.Totally got the wrong end stick. Sorry to hear your not doing the quizzes for now. Can't stress the importance of engineers understand IGEM G11 enough. Hope they pay more attention than I obviously did when I'm teaching them🙄

  • @k956upg
    @k956upg Před měsícem

    This is an ok idea aaa video but it’s painfully slow listing the at risk ncs id etc being slowly listed every question

    • @tomkatgastraining
      @tomkatgastraining  Před měsícem

      @@k956upg that my friend gives you the time to think what the answer is