HQST MPPT 20A 40A 60A Lithium Solar Charge Controller Review

Sdílet
Vložit
  • čas přidán 22. 07. 2024
  • The Professor reviews the HQST 20A 40A and 60A MPPT solar charge controllers for use with Lead or LiFePO4 12v 24v 36v 48v battery banks. Includes built in Parallel Ability, Bluetooth, and Low Temperature Charging Protection!
    CHECK OUT HQST MPPT: gohobo.io/hqstmppt use code HOBOTECH10
    DISCOUNT CODES on SOLAR PANELS - GENERATORS - REFRIGERATORS
    hobotech.tv/amazon
    SUBSCRIBE To BLOG (e-mail notifications)
    hobotech.tv/blog/
    FACEBOOK GROUP
    / hobotechcrew
    SNEAK PEEK of UPCOMING products
    / hobotech
    HAS THIS HELPED YOU?
    Buy me a coffee! You'll automatically be subscribed to e-mail notifications!
    www.buymeacoffee.com/HOBOTECH
    // - GENERATORS - //
    BLUETTI AC500 5000w Modular UPS LFP Generator BEST BUY
    gohobo.io/ac500 use code HOBOAC500
    ECOFLOW DELTA PRO 3600w Modular UPS LFP Battery Generator BEST BUY
    gohobo.io/CkOL use code EFHOBOTECH50
    Amazon + tax amzn.to/3MlPzCq
    ECOFLOW DELTA II 1800w LFP Generator BEST BUY
    gohobo.io/delta2 use code EFHOBOTECH50
    BLUETTI AC300 3000w Modular UPS LFP Battery Generator RECOMMENDED
    gohobo.io/nYHw use code HOBOAC3001B
    CANADA? shrsl.com/3hl1v
    Amazon +tax amzn.to/3MuBYZt
    BLUETTI AC200MAX 2048 Modular Battery Generator RECOMMENDED
    gohobo.io/goXO use code HOBO200MAX
    CANADA? shrsl.com/3hl1v
    Amazon +tax amzn.to/3rPywky
    JACKERY Explorer 2000 Pro RECOMMENDED
    gohobo.io/jackpro use code HOBOTECH
    JACKERY Explorer 1000 Pro RECOMMENDED
    gohobo.io/j1000p use code HOBOTECH
    BLUETTI EP500 PRO 5100wh UPS LFP Battery Generator
    gohobo.io/ZvQy use code HOBOEP500
    CANADA? shrsl.com/3hl1v
    BLUETTI AC200P 2000wh LiFePO4 Battery Generator
    gohobo.io/X6ys use code HOBO200P
    CANADA? shrsl.com/3hl1v
    Amazon +tax amzn.to/3xBp6u4
    JACKERY Explorer 1500
    gohobo.io/CweA use code HOBOTECH
    Amazon +tax amzn.to/3jfi8pV
    CANADA amzn.to/3fZ4aX1
    JACKERY Explorer 1000
    gohobo.io/vqkr use code HOBOTECH
    Amazon +tax amzn.to/38TEJiR
    CANADA amzn.to/3d7ll5g
    BLUETTI EB70s 800w LiFePO4 Generator
    gohobo.io/nBuo use code HOBO70S
    CANADA? shrsl.com/3hl1v
    BLUETTI AC50s 500wh Generator
    Use code HOBO50 gohobo.io/uCK6
    Amazon + tax amzn.to/36fwWg0
    CANADA? shrsl.com/3hl1v
    MAXOAK BLUETTI 2400w
    gohobo.io/Q3uo use code HOBO3000
    CANADA? shrsl.com/3hl1v
    Amazon +tax amzn.to/33UZKcj
    ECOFLOW RIVER PRO
    gohobo.io/2fTn use code EFHOBOTECH20
    Amazon +tax: amzn.to/3Ms9Iqx
    Jackery Explorer 500
    gohobo.io/ZiRP use code HOBOTECH
    Amazon +tax amzn.to/2XWA3bl
    CANADA amzn.to/2mI0CQf
    JACKERY Explorer 300
    gohobo.io/MZWw use code HOBOTECH
    Amazon +tax amzn.to/3lCbbhl
    CANADA amzn.to/3bPwPfO
    Jackery Explorer 240
    gohobo.io/bBPu use code HOBOTECH
    Amazon +tax: amzn.to/2VOL51s
    CANADA amzn.to/2pj5Rah
    //-- SOLAR PANELS --//
    BLUETTI 350w Solar Panel RECOMMENDED
    gohobo.io/ayja use code HOB350 for best price
    CANADA? shrsl.com/3hl1v
    BLUETTI 200w Solar Panel RECOMMENDED
    gohobo.io/f4UB use code HOBO200
    CANADA? shrsl.com/3hl1v
    On Amazon + tax amzn.to/30AXTs9
    BOUGERV 180w Solar Panels RECOMMENDED
    gohobo.io/ziEW use code HOBOTECH
    Amazon +tax: amzn.to/370r0px
    RENOGY SOLAR PANELS RECOMMENDED
    gohobo.io/8tvB use code RENOGYSOLAR10
    //-- BOOSTERS --//
    HIBOOST 4G Signal Boosters gohobo.io/23IS
    Use code HOBO20 for 20% off ALL mobile boosters!
    Use code 15OFF for 15% off SITE WIDE!
    HOBOTECH is viewer supported. When you buy through these links we may earn an affiliate commission. As an Amazon Associate I earn from qualifying purchases.
    SUPPORT THE CHANNEL
    To shop directly on Amazon for products not on our store page you can use this link: amzn.to/2utihvF
    HOBO STICKERS, T-SHIRTS, MUGS, BEANIES, ODIN MERCH
    hobotech.tv/shop/
    DONATIONS
    hobotech.tv/support/
    GET SOCIAL
    Facebook Group: / hobotechcrew
    Instagram: / hobotechtom
    Hobo HQ: www.hobotech.tv
    BUSINESS INQUIRIES / E-MAIL
    hobotech.tv/contact-us/
    NOT a free help line! Business only!
    ============================
    #reviews #chargecontroller #solar #offgrid #DIYsolar #boondocking #rvlife #rvliving #vanlife
    ============================
    LIKE COMMENT SUBSCRIBE!
    (c)2023 hobotech.tv

Komentáře • 282

  • @HOBOTECH
    @HOBOTECH  Před rokem +19

    The Professor reviews the HQST 20A 40A and 60A MPPT solar charge controllers for use with Lead or LiFePO4 12v 24v 36v 48v battery banks. Includes built in Parallel Ability, Bluetooth, and Low Temperature Charging Protection!
    CHECK OUT HQST MPPT: gohobo.io/hqstmppt use code HOBOTECH10
    [PROOF 20A/40A controllers also have LOW TEMP CUTOFF czcams.com/users/shortssRsq9YqlLxk ]

    • @Mae-nr7wr
      @Mae-nr7wr Před rokem +2

      where is da ecoflow delta 2 max review !!!

    • @Fogatti910
      @Fogatti910 Před rokem

      Awesome!!

    • @afolayandammy9161
      @afolayandammy9161 Před 11 měsíci

      What is the name of the bluetooth app please

    • @5thdayadventures
      @5thdayadventures Před 10 měsíci

      Looks like the code HOBOTECH10 is no longer being accepted

    • @charlestresnicky1144
      @charlestresnicky1144 Před 9 měsíci

      Thank You Professor! I got the 40amp while on sale and set it up this weekend, hoping to upgrade later on panels and run another 40 amp parallel. Cheers

  • @vidzilla1
    @vidzilla1 Před rokem +28

    I have been using this solar charger controller for 8 months, very happy with it !

    • @jtnoodle
      @jtnoodle Před 10 měsíci

      update us in a couple years.

    • @d.l.sstudio8922
      @d.l.sstudio8922 Před 3 měsíci

      @@jtnoodleI’ve had mine for 9 months or so now and it’s been perfect. I bought a second 60A controller to charger for a total of 120A! Haven’t installed the second yet but will soon.

  • @airinbone
    @airinbone Před rokem +18

    This is my choice in price range. It offers so much.

  • @astrobob9432
    @astrobob9432 Před rokem +2

    I have had the 40amp model for about the last year. No real issues with it yet. I was unaware of the low temp cutoff feature, thanks for showing us! Go Hobo!

  • @iggykoopa7756
    @iggykoopa7756 Před rokem +5

    I have had mine for a bit over a year, its hooked up to 3 110ah 12v deep cycles with 3 renogy solar panels running into it. Works awesome and ive been really impressed with it.

  • @Cabernet2000
    @Cabernet2000 Před rokem +2

    Ordered the 60. Thank you, HOBO. Will buy 20,40 later as I expand versatility. Just getting going.

  • @Datzneat
    @Datzneat Před rokem +1

    Picked one up to replace the pwm charger that came with my old flexible Renogy panels. Just need a good inverter charger and the cabling/tools to make it all work now. Thanks for the discount.

  • @jamesthompson7282
    @jamesthompson7282 Před rokem +1

    Great review of a good product with extensive feature set at a VERY competitive price. Prof. Hobo delivers!

  • @davidgunther8428
    @davidgunther8428 Před rokem +10

    I picked up the 40A charger a few months ago. Having built in Bluetooth and the low self power consumption were the selling points.

  • @mikeh1589
    @mikeh1589 Před rokem +1

    Thanks HOBOTECH. You saved me some money on some HQST 60 Amp charge controllers 😎

  • @svenshanah
    @svenshanah Před 7 měsíci +1

    Funny Fact;
    I was about to get the Victron..I was so set on it that I had this video in Que way back when it was new, and ignored this video because due to issues with cheaper stuff, I was done playin'..
    Well, as life goes I got side tracked on other projects and I'm just now getting around to playin' with my solar stuff again, and I decided to hear this video out, only to hear this basically is a Victron - so I just went from buying one Victron at a time to three of these 60 amps (I'm going 48v on this next system, and my bugout location gets in the single digits), and I'll be way better off for it.
    Thanks Professor..😎👍

  • @rtpman1953
    @rtpman1953 Před rokem

    Thanks for the well-done video. I've been using a MPPT controller that handles the same voltage/amps but no parallel. If I factor in the Bluetooth app instead of a remote display, it makes sense to slowly switch over to this.

  • @mkuhlman77
    @mkuhlman77 Před rokem +12

    I've been using the 20A version for 3 years now and love it. I was just thinking about get more power but noticed I'd already maxed her out. I didn't realize you could add another controller. This is great news. Thanks for the review. I'll keep buying these over Renergy any day .

    • @wndy7073
      @wndy7073 Před rokem +1

      I want to get this;
      10% off of $89.oo on this 20 amp model would be a fantastic bargain 😀

    • @junkerzn7312
      @junkerzn7312 Před 6 měsíci +1

      You can put as many charge controllers on your battery as you want, up to the current limit that the battery supports. Though its nice (they all switch charging stages simultaneously when they have comms)... charge controllers don't actually need to know that there are other charge controllers on the system.
      So if you have a battery bank, bus bars, and battery wiring that can handle charging at 100A, nothing is stopping you from putting 5 x 20A charge controllers on the system. (Each charge controller being only 20A can use 10 AWG wiring. The battery cabling itself would have to be 2 AWG to handle 100A reasonably well).
      For the same reason, you can hang multiple inverters off of a battery bank such that the total amperage they pull does not exceed the bank/wiring capabilities.
      -Matt

  • @davef.2329
    @davef.2329 Před rokem +1

    These controllers are great. We now have 4 of them in service and after installing the first one, replaced 3 other functional units of other brands with these, since they work so well. Have a variety of panels from them that work great, too. Good, reliable, quality equipment.

    • @mrdemascal
      @mrdemascal Před 3 měsíci

      Do you have various watts/amps strings of panels running to them? I have 2 400w strings paralleled into our current 60A unit. Want to add 400 to 600 more watts with a 40 amp controller. From your experience will having 600watts on one controller and 800 on the other decrease the input from the 800 unit? Hope that wording makes sense?

  • @Mr.Avuncular
    @Mr.Avuncular Před rokem +2

    Thanks professor for the heads up and great price
    Bang bang!

  • @texasprepperprojects
    @texasprepperprojects Před rokem +4

    I have the 20amp when I built my solar cart. I was pleasantly surprised with the bluetooth app. I also have their solar panels. I think that their pricing is great and I was pleased with the build quality.

    • @junkerzn7312
      @junkerzn7312 Před 6 měsíci

      HQST has some great solar panels. The 9BBs and now 10BBs are great panels.

  • @austindishman6338
    @austindishman6338 Před rokem

    Thank for doing the short video to answer my question

  • @trumpingtonfanhurst694
    @trumpingtonfanhurst694 Před rokem +2

    I always enjoy your vids, thanks hobo 😊

  • @KA9DSL
    @KA9DSL Před rokem +2

    It looks more friendly user and more versatile than my Renogy MPPT. Nice price. Might order one!

  • @jalindell
    @jalindell Před rokem +1

    Heck yeah, I have the small one the 20amp and I love it.

  • @UPdan
    @UPdan Před rokem

    Loving my HQST. Better look at the vtoman Prospeed 3000. Wow !!! Loving that display panel.

  • @vaughnsvideos
    @vaughnsvideos Před rokem +2

    Hey Tom. Sorry I dropped Patreon support, after two years I was just not in the market for a SoGen and was really here for the campervan stuff and I am about to retire and your channel is doing well, so I just had to tighten the belt a little. Still think you are great though and wish you the best of luck and I like to see things like this mixed in. Maybe things will line up again in the future and I can toss more love your way.

  • @joshuafreeman9792
    @joshuafreeman9792 Před rokem +1

    I have the 20 and 40 pluses one of the srn looking one the had before love them all

  • @Banagal
    @Banagal Před rokem +1

    Thanks for this review.

  • @stevecarlisle3323
    @stevecarlisle3323 Před 7 měsíci +1

    Would be very helpful if you explain Advanced Settings mode, and what options are available. Thanks for the video.

  • @HoosierOutdoor
    @HoosierOutdoor Před rokem +5

    Low temp cut-off in a budget controller.. without paying the big blue price.. this is gonna be my next controller

    • @BobBob-il2ku
      @BobBob-il2ku Před 11 měsíci

      Same

    • @rickreid5896
      @rickreid5896 Před 8 měsíci +2

      Send their customer support an email saying your having trouble with a unit you just bought. No answer. Send them another one to the same customer support saying you want to buy there 60a controller. Wow, you just got an answer but not about that first email.

  • @Golfreak
    @Golfreak Před 11 měsíci +1

    I have the same exact HQST but 40a version. It is rock solid and runs very cool. I find the parallel feature not needed. I have the HQST and a SCNE 20a mppt both charging the same battery bank and it's not a problem.

    • @junkerzn7312
      @junkerzn7312 Před 6 měsíci

      Right. You don't need the paralleling feature. The worst that happens is that the various charge controllers don't switch charge stage states in tandem. That can be a bit of an eyesore but it doesn't really hurt anything.

  • @thayne559
    @thayne559 Před dnem

    Im glad I saw this video. I just ordered a piece of junk eco-worthy 60 amp controller last week on amazon and after setting it up I found it doesnt work. Im retuning it and just ordered this one! and it was only $20 more when ordering from their website!

  • @chrisreynolds6331
    @chrisreynolds6331 Před 11 měsíci

    I bought a bench power supply last week it's ideal for testing MPPT controllers

  • @pdieppa
    @pdieppa Před rokem

    Yes!!!! Thank you for the fx!!!!

  • @JeffRoush
    @JeffRoush Před 7 měsíci +2

    I wish I had seen your video first! I just bought the Li Time version of this ( I was buying their batteries so I figured I'd stay in their ecosystem ). It looks to be the exact same device with a different paint job, but they must have modified the firmware. Mine does not have the setting to tun on/off the low temp cutoff and, even though it came with the temperature probe, their version of the manual specifically says to NOT use the temperature probe with LiFePO4 batteries. Odd that it came with the probe but has no way to turn the function on/off. Anyway, thanks for the great video!

    • @2hotscottpro
      @2hotscottpro Před 6 měsíci

      Wonder what’s up with that.But you have 5 year warranty vs just one.

    • @lawrencedavidson6195
      @lawrencedavidson6195 Před 11 dny

      I got the LiTime 60 amp controller on sale on Amazon for $204.00 Nov 2023. Since then the price is up to $270.00. When i upgrade i will be getting the HQST 60A as the price is waay better at $220.00

  • @2626sylver2626
    @2626sylver2626 Před rokem

    Sir you won yourself another subscriber 🙂🙂

  • @NotMeeither
    @NotMeeither Před rokem +2

    I wish that this video had came out before.I ordered a new charge controller!

    • @rickreid5896
      @rickreid5896 Před 8 měsíci

      Don't worry, you saved yourself some money.

  • @kevinroberts781
    @kevinroberts781 Před rokem +10

    The smaller one needs to be the master because its more limited. You don't want the 60 amp model telling the 20 amp model to do something it can't do.

    • @michaelball7440
      @michaelball7440 Před měsícem +1

      I have two 60a units in parallel mode and I see no difference in operation either with or without this mode. What exactly is supposed to occur in parallel. And I have, of course, two solar panel banks, 800w and 760w. Starting either controller first, making that the master, makes no difference either...

    • @2hotscottpro
      @2hotscottpro Před měsícem

      Cable seems to be a joke? I have 2 60a controllers also going to 1 bat bank.Cable paring didn’t make so I only need to see 1 controller on app.Weird

    • @2hotscottpro
      @2hotscottpro Před 28 dny

      LiTime says cable was only used in development.We don’t need one.😊

    • @Ellifiknow
      @Ellifiknow Před dnem

      Good observation.

  • @alaingoyette7103
    @alaingoyette7103 Před měsícem

    Thanks for this great informative video. I had not heard of that product before. I have looked at their documentation and could not find the minimum PV input voltage to get it running. Do you have this information? 🤔😊

  • @thedabbler2753
    @thedabbler2753 Před rokem +2

    I have the 60A. A couple of other things of note. DC load terminal control (dusk/dawn/timer) and battery charge parameters can be controlled completely from the app. Regarding the auto 12/24/48v claim on the front, what I found was that it wasn't actually auto. What happened on switching from 12 to 24v LI was that it registered 26.5v coming in and flashed the error light at me until I changed the system voltage to 24v. Perhaps that's a safety mechanism, and certainly not a big deal by any means, but I thought it would just automatically switch. Other than that and perhaps wishing the Bluetooth range was a bit further without having to buy an external antennae, I love the 60A. It's so well built, it just works, and at a price that should embarrass the likes of Victron (yeah, 31 bucks for the temp sensor *wire* Victron, really???). Great job HQST :)

    • @junkerzn7312
      @junkerzn7312 Před 6 měsíci +1

      It probably works the same as the Victron where it is auto upon initial commissioning, but after that if you change the battery voltage you have to adjust the charger controller manually. Definitely a safety feature because you don't want a charge controller mistaking a dead battery with a lower-voltage battery.

  • @HimitsuYama
    @HimitsuYama Před rokem +7

    My Victron equipment has always been rock solid, though at a price. It would be great if another vendor provided equipment of similar quality at a reduced price. I’ll keep my eye on HQST.

    • @retrozmachine1189
      @retrozmachine1189 Před rokem +2

      If you are looking at these things look into helios (the OEM that makes it) M4860N

    • @superphotog
      @superphotog Před 9 měsíci

      @@retrozmachine1189 - Low temp cut out on Helios? Went to their website and no mention of low temp protection.

    • @stevecarlisle3323
      @stevecarlisle3323 Před 6 měsíci

      Okay, there are many companies selling these re branded Helios units, so what's your point ?​@@retrozmachine1189

  • @JaiManny
    @JaiManny Před 11 měsíci

    Just bought one... Simply based on this video.

  • @brucewoytassek9299
    @brucewoytassek9299 Před 11 měsíci +1

    Thanks for doing what you do! I am educating myself on Solar and you are a good part of my education! I currently have 2 190 watt panels in parallel , 2 wet 12VDC 100 AH batteries in parallel and a 30 amp PWM charge controller. Thinking of upgrading to MPPT controller, smart shunt and eventually Lithium batteries. Would the 60 AMP controller work on my 30 amp system so I can upgrade as finances are ready? (Travel trailer) -- PS: I think you should offer a "HOBO Certificate" for watchers! Thanks again! bw in ND.

  • @ChrisDeLuca
    @ChrisDeLuca Před rokem +4

    I figure the reason the smaller one becomes the master is because. It cannot handle as much input nor can it run a 48 V system. Therefore they will default to the least common. Denominator which would be the smaller of the two units

    • @Avman3369
      @Avman3369 Před rokem +1

      My thoughts also. It would also work for the 60A controller to be the primary if when it was installed in parallel with the 20/40A units and be limited to 12/24V settings automatically.

  • @cardinhamkilligrew9712
    @cardinhamkilligrew9712 Před rokem +1

    I am saving for the 20 AMP now...

  • @ericklein5097
    @ericklein5097 Před rokem +1

    That minute delay might be put in the firmware on purpose to prevent any false readings or something that would cause the sensor to be exposed to a really cold gust of air for a brief period of time

  • @stevecarlisle3323
    @stevecarlisle3323 Před 7 měsíci

    Thanks for your helpfull videos. I have poor solar in the winter months in the north. I also see you have been bench testing charge controllers with lab constant power supply. Is it possible for me to switch between solar source, or wind power ?

  • @MarkSDCA
    @MarkSDCA Před 11 měsíci

    Thanks for all the great videos. Very helpful. Can I charge my 300Ah battery bank with two seperate MPPT charge controllers, one mounted on top of the trailer and the other is a portable panel used when the trailer is in the shade and I need to remote the panel. What do you think?

  • @BobBob-il2ku
    @BobBob-il2ku Před rokem +2

    Can you change the tempature cutoff from 0 Celsius to 5 Celsius for example?

  • @rvertv
    @rvertv Před rokem +2

    what a great price. good review and video

  • @traphouse5941
    @traphouse5941 Před rokem

    Hi i got a question i got a 12v deep cycle marine battery and i would like to know if i can charge it at around 12amps or it would be better 6amps? Thanks

  • @superphotog
    @superphotog Před 9 měsíci

    I wanted to buy the 60amp one but $$ ($290CDN) and current and 'immediate future' solar plans for an emergencies and RVing will not be requiring the 60amp model so I ordered the 40amp. #1 consideration was built in low temp cut off so I can use the refurbished non-heated mini lifepo4's from Power Queen and Li Time. The Li-Time was partially Hobotech's recommendation with an assist from John Daniel.
    There has been talk in the solar power forums as to the relationship between HQST and Renogy. I would say joined at the hip. My order acknowledgement for the HQST controller was from Renogy. Photos in the forums of products received from all HQST products orders have some pieces arrive in Renogy packaging. I would guess part of the strategy is to have a lower cost outlet as one pays royally for Renogy. The other, much to the chagrin of their Canadian customers, is how bad Renogy's customer service reputation is. They have a BBB rating of 1.15. Products are respected, relied on and 'top shelf,' customer service is abysmal.

  • @advancedxdirective
    @advancedxdirective Před rokem

    Do you think the 20 amp version would be good for the 3rd input of the leoch?

  • @AQUASCAN1
    @AQUASCAN1 Před 10 měsíci

    On the parallel cable do you know if all 6 pins being used?
    Thanks in advance.

  • @kevinmills5293
    @kevinmills5293 Před 4 měsíci

    Hi, I’m looking at this as an alternative to the Victron SCC and I’ve studied the user manual but I can’t find anything about the absorb time. Is it user configurable and if not, how is the absorb time determined?

  • @MikeJordanUnCamplicated
    @MikeJordanUnCamplicated Před rokem +4

    Love my HQST panels. I've got an RV full of the Blue stuff. But looking for a DC-DC charger and I don't want to spend Blue stuff money this time around. I have my eye on that other HQST related unmentionable brand. But HQST needs to jump on the DC-DC charger band wagon

  • @DC_tronicFPV
    @DC_tronicFPV Před 7 měsíci

    Just went through the settings on my 40amp and does not have on/off for low temp. Any advice?

  • @jchal5180
    @jchal5180 Před rokem +3

    Really like this

  • @mrdemascal
    @mrdemascal Před 3 měsíci

    If you have various watts/amps strings of panels running to the controller will ot make the efficiency of the bigger system less or just add the watts from each system together ? I have 2 400w strings paralleled into our current 60A unit. Want to add 400 to 600 more watts with a 40 amp controller. From your experience will having 600watts on one controller and 800 on the other decrease the input from the 800 unit? Hope that wording makes sense?

  • @astrobob9432
    @astrobob9432 Před rokem

    Hey, Hobo! when will you have a review on the Bluetti AC180?

  • @mikesgarage394
    @mikesgarage394 Před rokem

    Hmm, that explains why the screen pictures in the manule are identical to thos in the wanderer manual.

  • @user-rx6up8wr2z
    @user-rx6up8wr2z Před 11 měsíci

    Please reply. Can the 60amp controller charge my 12v li batt at 60 amps and still give extra 10+ amps of power off the direct load terminal. Maybe a stupid question but...

  • @nikolatesla5553
    @nikolatesla5553 Před 8 měsíci +2

    I have been extra concerned about the low temperature shutoff. My Lithium battery bank is my most expensive part of my system. At Sunrise in the Northwest thr temperature is often below or hovering around freezing. I would hate to have to replace $1500 of batteries of because of freezing temperatures. Can a minute of charging cause damage? I would feel more comfortable if i could set a temperature shutoff a little above freezing. But I admit I might be just paranoid. Any opinions?

  • @21degrees
    @21degrees Před rokem +1

    Great Vid! Thanx

  • @ccox7072
    @ccox7072 Před 5 měsíci

    This may be a dumb question, but can I over panel these controllers like I can on my Bluetti EB240?

  • @greglp970
    @greglp970 Před 4 měsíci +1

    Just to let everyone know… I was planning on purchasing three (3) 60A MPPT controllers.
    I sent a question to their “sales” email address (the ONLY email address there is) on Feb 24, 2024 and I did NOT get a response.
    I sent another email on March 3, 2024 and have NOT gotten response.
    So… I went to their website looking for a phone # to call them.
    Nope NO phone #!!
    That was it FOR me!!
    If they’re NOT willing to answer “SALES” enquiry emails and there’s NO phone # to call…
    You can FORGET about EVER filling a warranty claim!!

  • @jimhager8583
    @jimhager8583 Před 5 měsíci

    Thank you Hobo, know I know

  • @DeliberateNRandom
    @DeliberateNRandom Před rokem +3

    Even Will Prowse has recommended HQST in the past. I bought one solar panel from them and a couple Renogy ones more recently.

  • @johnsemrau6412
    @johnsemrau6412 Před 2 měsíci

    So would I be safe running a 1000 watts solar with some shade on 400 watts?

  • @ThunderChicken1
    @ThunderChicken1 Před 9 měsíci

    Something else that's not in the manual. How do you set the WH rating on the 2440N

  • @phillipzx3754
    @phillipzx3754 Před 6 měsíci +1

    When I looked up the HQST headquarters address using Google Earth, it seems this is a brand of Renogy? And since the new Li Time controllers look the same as the HQST models, is Li Time also a Renogy brand? Not that I have an issue with it. Just trying to connect the manufacturing dots.

  • @DroneManMurphy
    @DroneManMurphy Před 5 měsíci

    How do we change the temperature from Celsius to Fahrenheit?

  • @VanlifeWithus-lr2et
    @VanlifeWithus-lr2et Před 9 měsíci

    Can these units be connected by Bluetooth to an external android screen/tablet without Internet?

  • @4428314
    @4428314 Před 9 měsíci

    Good Lord, you are a fountain of information! Thank you for your expl

  • @2hotscottpro
    @2hotscottpro Před 6 měsíci

    Go the advanced settings, change your float voltage to 13.6 and change your Boost voltage to not more than 13.9v. Once you set your boost voltage above 13.9, the error happens. If you set your boost voltage below 13.9, you wont have the issue again. However that means you wont be able to fully harness the power of your solar panels. Lifepo4 battery ideally use 14.6v as boost voltage

    • @junkerzn7312
      @junkerzn7312 Před 6 měsíci +2

      The boost voltage generally has to be 14.2V when using generic 4s LiFePO4 batteries, otherwise their internal balancers won't ever trigger. 14.6V is 3.65V/cell which is typically the BMS disconnect voltage... you generally don't want to charge the batteries to that point. The BMS low and high voltage disconnects are always supposed to be the last line of defense, not the first line of defense and the high voltage disconnect can cause the charge controllers to over-volt the battery bus when it trips.
      The float should always be between 13.4V and 13.5V ( 3.35V/cell to 3.375V/cell). Any lower and you lose capacity when dropping down to the float, any higher and the float will overcharge the battery if held long enough.
      -Matt

    • @2hotscottpro
      @2hotscottpro Před 6 měsíci

      I copied that from someone else that had issue from the comments.

  • @junkerzn7312
    @junkerzn7312 Před 6 měsíci

    It actually looks quite decent, very similar to Victron charge controllers though I dunno if they have the level of device integration that Victron has. Particularly if one has a shunt in the system. Victron has a number of very flexible relay control features.
    You can always parallel charge controllers, no integration required for that. But Victron's can be ganged together in a virtual bluetooth network so they will communicate with each other without any cabling.
    Now one area where the Victron really falls short is the auxiliary Load output. Only some of Victron's smaller charge controllers have it, and more importantly the Victron load output can't handle startup surges... for example, if you are trying to power a small inverter or grid-tie microinverter from the load output, or any device with input capacitors, the Victron will fall flat and not be able to enable the output (it thinks it is shorted and gives up). So I wonder how the HQST controller deals with startup surges like that, and also whether the HQST can handle the full 20A on a 48V system, as well as a bit of power factor, without blowing up its load switch (which is usually a FET).
    I also wonder what kind of solar "voltage" headroom is required above the battery voltage to be able to get the full output. It is fairly typical for very high efficiency charge controllers to be buck-only (rather than buck-boost). This means that the solar operating voltage has to be a number of volts above the battery voltage to be able to push full amps into the battery. Usually 5-10V or so.
    It looks on the face of it that the HQST is passively heat-sinked, as is the Victron, which is a big plus. Any charge controller that requires a fan is a charge controller that you should never buy.
    Its too bad that HQST only offers 48V support with their 60A charge controller. And for a premium too, $220. That is not competitive with Victron's SmartSolar 100/20 which is also able to handle 48V battery systems and is only $90. At 48V (well, 51.2V nominal), 20A is usually plenty for a small system... over 1000W and generally one is already ganging a few strings together to get it so you generally want a separate MPPT input for any further expansion. A lot of the 60A capability of the HQST is going to be wasted due to the limited voltage range the HQST support. Victron has a more balanced, useful offering in this regard.
    -Matt

  • @BobBob-il2ku
    @BobBob-il2ku Před rokem

    Epever AN series charge controllers updated there firmware & now have the low temp Charge protection too but you have to enable it via a pc with there usb cable

    • @superphotog
      @superphotog Před 9 měsíci

      And they generally cost more feature for feature.

  • @drgranger2
    @drgranger2 Před rokem

    Good information. Thank you

  • @davidpatrick1813
    @davidpatrick1813 Před rokem

    V V for victory for var var varsity. 🙂 Nice review

  • @johnshaw359
    @johnshaw359 Před rokem +2

    Seems logical that the smaller unit takes control. They switch as a safety feature when you change critical parameters.

  • @d.l.sstudio8922
    @d.l.sstudio8922 Před 3 měsíci

    Have you been using the “LI” mode for lifepo4 batteries? Or are you using a custom setting for them? The “LI” setting will keep your battery at full voltage until the solar panels power output decreases from lack of sun. I thought keeping your batteries at “charging voltage” increased degradation of cells? Or is this a myth? Just trying to find the best charging setting for my Lifepo4 batteries. I’ve been using the “Victron” settings that are posted on will prowes forum. 28.4v boost, 27.2v float
    Would you use the this custom setting or the standard “LI” setting on the HQST controller?

  • @joeclark9042
    @joeclark9042 Před 8 měsíci

    Very good video buddy I really enjoyed this I got to ask you a question will this do flood batteries also please let me know if so I'm going to buy me a couple of these things thank you very much

  • @barongugelsurch1145
    @barongugelsurch1145 Před 8 měsíci

    Can a pwm safely charge a lifepo4 battery?

  • @SolarSun-wp6oh
    @SolarSun-wp6oh Před 11 měsíci +1

    I would like you to test out sunthysis charge controller there is only one other CZcamsr that has tested and it is half the price but is it as good don't know

  • @readypetequalmers7360

    is there any security on the bluetooth like being able to disable it? I always get annoyed how someone can walk by and takes control of devices. I wouldn't want to keep an eye on my settings make sure they are at safe levels.

    • @rickreid5896
      @rickreid5896 Před 8 měsíci

      You need to be really close to use the Bluetooth function. If it works.

  • @lisakroner-reddy4282
    @lisakroner-reddy4282 Před 10 měsíci

    I bought the 40 amp model for use with my 200ah LiFePo4 Powerurus battery, using a gopower 200 watt solar panel. Unfortunately, my battery was pretty low when I installed the Mppt Solar charge controller, and it seems to be taking quite a while to fully charge the battery using only solar. What do you recommend I customize the MPPT settings to? Or, should I just leave the default settings? TIA

    • @2hotscottpro
      @2hotscottpro Před 6 měsíci

      Get 2 more panels.A 600 watt panel is recommended for my 230ah bat.

  • @jheighten7568
    @jheighten7568 Před 8 měsíci +2

    I just bought Yuma 200w flexible panel. Would I be able to use the 60A. ?

  • @WhatNowChris
    @WhatNowChris Před rokem +2

    You should do a complete video on controllers and LifePo4 batteries. I purchased a ampere time 200ah LiPo4 after your review of the battery. I have a renogy rover 40amp charge controller, when I throw it on Li settings, it flashes over charge. I’m not sure why. I contacted ampere time, they told me to put in user settings, and the battery charges fine now, only problem is once the sun goes down and there’s a small load on it, the volts drop to 13.1 volts. According to the book that’s 50-60% charged(something like that). Is that normal? Maybe a bad battery? Please help! Thank you.

  • @user-rp1vu1gk5u
    @user-rp1vu1gk5u Před rokem

    sorry im new to this, i bought a couple lion energy 12v 100 watt pannels and a dr. prepare 1280 battery to run a fridge in the garage.
    will this 20amp or 40amp charge controller plus an ac inverter work for my needs?

  • @TheCornucopiaProject-bd5jk

    I would certainly go for the 60amp model. I think you should have a charge controller that can supply enough energy for a 12v 100ah battery.
    Speaking of battery cables. I use 4/0 cable to and from the battery (via busbar) as well as the inverter and I use 4awg cable for pretty much everything else. Welding cable of course.

    • @davidgunther8428
      @davidgunther8428 Před rokem +1

      At 60A charge rate, a 100Ah battery is pretty small, and going to often leave the solar panel output under utilized. 🤔

    • @TheCornucopiaProject-bd5jk
      @TheCornucopiaProject-bd5jk Před rokem

      @@davidgunther8428 depends on the size of the solar array. In a Van or RV 300-1200 watt of solar is common, with most people being between 300-600 watt. That 60amp charge controller handles 900 watt of solar.

    • @davidgunther8428
      @davidgunther8428 Před rokem

      @@TheCornucopiaProject-bd5jk at 600W the charge time for 12.8V 100Ah battery would be about 2.5 hours. The rest of the day the solar would barely be utilized. At 900W in, I think the battery would be in constant current charging for less than an hour, then start to taper. This is why I thought 100Ah is small for a 60A charger.

    • @TheCornucopiaProject-bd5jk
      @TheCornucopiaProject-bd5jk Před rokem +3

      @@davidgunther8428 ok, I re-read my original statement. I wasn’t clear. I think the 20 and 40amp controllers are undersized even for a 100ah battery. While the 20amp 300watt controller can charge a battery in a day, I rather have the “option” to add solar panels to either charge my battery faster and/or get a full charge even during bad weather conditions. I like to have expansion capabilities even if I don’t exercise them. So I’d always get the larger model

  • @lakorai2
    @lakorai2 Před rokem +1

    Would be all over this if it supported dc to dc charging as well

  • @davidcarrico3385
    @davidcarrico3385 Před rokem +1

    A couple of questions on the 20mpg model. Could this be used to charge something like a Bluetti eb70s? If so, since it supports 12 and 24 volt charging, what would it auto detect from the eb70s’ 8mm port? Also, and I’m not sure what the right term is, but what’s the charge voltage for a 24v lfp battery? I believe it’s in the 14s for a 12 v, does that mean for a 24v that it would be in the 28s or 29s (possibly exceeding the eb70s’ 28v max)? I doubt it would be financially advantageous to do this just to get a few extra w out of my panels, but I have been on a quest of how to squeak out the most efficient charging given the eb70s’ limits, without purchasing their panels, which are fairly expensive. I currently own two 120w panels and I think their VoC is something like 21.7v ish (can’t remember the exact spec off the top of my head), so I hit the 8amp limit on the eb70s before hitting 200w of input.

    • @HOBOTECH
      @HOBOTECH  Před rokem +4

      Solar generators already have built in solar controllers so you can't use this on those.

  • @gregyohngy
    @gregyohngy Před rokem +1

    I can use the 48V version with any solar panels to power my Ebike!
    I missed it, but can you limit the Amps being delivered?

    • @rickreid5896
      @rickreid5896 Před 8 měsíci

      No and it overheats when it gets even close to the 60a mark

  • @maverickmikekauai3515
    @maverickmikekauai3515 Před 6 měsíci +1

    Aloha, is it possible to set user defined specifications for non standard batteries? (like repurposed Nissan Leaf EV batteries) Thanks for the great job I really enjoy your videos.

  • @EccentricOffGrid
    @EccentricOffGrid Před 4 měsíci

    I wish victron had these colors

  • @davidhovis2299
    @davidhovis2299 Před 4 měsíci

    Just stumbled on this after dragging my feet on not wanting to spend victron money but needing 100+ amps of charging with room to expand. I see these can be paralleled, but curious if three can be used together?

  • @mikeh1589
    @mikeh1589 Před rokem

    I cant find HQST customer service phone number ? And how would you rate HQST 60 vs Renogys 60 Amp model ? Have you done a Renogy charge controller review ? Thanks Dr. Hobo.

  • @marsrover001
    @marsrover001 Před rokem

    Other than the settings sharing I don't particularly see a use for "parallel" options. You could always hook 2 mppt's to the same battery with no issues without the parallel cable. Settings only take 10 minutes to program and you never touch them again. I just really don't understand why that's a feature.

    • @hqstsolar2630
      @hqstsolar2630 Před rokem +3

      Two commonly used controllers can be connected to charge a single battery bank system simultaneously. However, our MPPT controllers offer several advantages with their parallel charging function:
      1. Information exchange and charging settings synchronization between the two controllers are possible.
      2. Inconsistencies in setting parameters between the two controllers are avoided. When you adjust the settings of the primary controller through the app, all changes will be automatically synchronized to the secondary controller, reducing the need for manual adjustments.
      3. Enhanced charging efficiency is ensured. Controllers with different specifications may have varying charging accuracies. When two controllers with significant differences in power and precision are used in parallel to charge a single battery bank system, there is a risk of one controller misinterpreting the charging parameter information, which can impact charging efficiency.
      4. Improved safety during charging. If the primary controller detects any abnormalities in the system, it can shut off charging on its own and simultaneously instruct the secondary controller to do the same. This protective measure enhances the overall safety of the battery system.
      Hope it helps clear up your confusion.

  • @MrBumbles2
    @MrBumbles2 Před 10 měsíci

    hqst, redodo, li time all have these out. some the bluetooth works some don't lol. my renogy died looking at one of these

    • @superphotog
      @superphotog Před 9 měsíci

      Don't think Redodo or Li Time have low temp cutoff. I saw the insides of the Redodo and the HQST and they were different circuit boards.

  • @unclechris3958
    @unclechris3958 Před rokem

    I wonder what brand it is associated with

  • @chadrogers3161
    @chadrogers3161 Před rokem +1

    Looking at the 40 amp model now....if my panels are under the 100 volts voc but they produce about 900 watts out of the 4 panels will this blow the controller??

  • @JOHNG104A
    @JOHNG104A Před 2 měsíci

    My hqst controller came in a box labeled renogy

  • @Nemo_IRL
    @Nemo_IRL Před rokem +1

    It's interesting that you can parallel 2 of these together but I'm wondering what are the advantages of doing so, since you can run multiple charge controllers on one battery bank anyway.

    • @Golfreak
      @Golfreak Před 11 měsíci

      That's what I posted. I have 2 different mppts on 1 battery bank and I have zero problem.

    • @junkerzn7312
      @junkerzn7312 Před 6 měsíci

      Multiple charge controllers will read different battery voltages on the battery bus due to a combination of differences in the voltage sensor and differences in the currents each charge controller is pushing.
      Generally speaking the comms are just there so the charge controllers change battery charging states in tandem. e.g. Bulk -> Absorb, Absorb -> Float, Float -> Bulk. It is not absolutely necessary that it happen, it's just less of an eyesore when they are synchronized. The network will choose one charge controller's voltage reading and all the units will use that one source.
      In a Victron system, for example, this is automatic when the charge controllers are on the same Bluetooth VNET. In addition, the Victron app will blare warnings at you if any of the charge controllers have different parameter settings.

  • @kimmer6
    @kimmer6 Před rokem

    I have several Renogy MPPT controllers (20,30, 40, 60 and the 100amp versions) and they have been very reliable for me. I just tested out my old Vandura van's new power system, Rover Elite 40 amp MPPT, 400 watts in panels, Renogy 2000 watt inverter, 300AH Chins battery, BT-2 blue tooth. Went camping overnight at Bodega Bay but were not attacked by Hitchcock birds.... Works great. I watched the Renogy battery SOC meter hit 100% on the way home and saw the solar charge volts drop to zero. However, the Elite does not have the load terminals like the Rover. I'm disappointed. I would like to turn on 12 volt lighting with my cell phone app like the 30 amp Rover has. Is the light bulb over the terminals on the HQST signifying a blue tooth relay? The Rover can operate a 20 amp load. I might pick up the 40 amp HQST but would like to know if those are load terminals. I like the included blue tooth function, too, without having to buy another module.

    • @junkerzn7312
      @junkerzn7312 Před 6 měsíci +1

      Load terminals are a bit of a mixed bag. They are usually controlled by a solid-state relay (a FET in the charge controller), often with serious limitations and a ton of fragility. I don't know how good the HQST's load output is but I can say for sure that Victron's solid state relays are pretty horrible. I've burned more than one out on their smaller charge controllers (Victron doesn't even have load terminals on their larger charger controllers any more). Even Victron's battery protect devices are fairly poor at dealing with inductive loads and devices with input capacitors.
      I wonder how good HQST's load output is.