Lambda MML 400 Switchmode Power Supply Troubleshoot And Repair
Vložit
- čas přidán 21. 06. 2024
- Follow along on this troubleshooting and repair adventure of a Lambda Omega MML 400 switch mode DC power supply (SMPS). No schematics are available so let's see what it takes to track down the problems.
#powersupply #electronicsrepair #learnelectronics - Věda a technologie
Great diagnosis! Lambda made some great supplies
Thanks and yes they sure did make some quality heavy duty power supplies.
Great video and well done trouble shooting!
Thank you!
Wow. Module is quite quality
Thank you for another great video! One minor note for someone trying to replicate the high frequency AC voltage measurement: The 34465A is specified for up to 300kHz, but most hand-held DMMs are much more limited, e. g. Fluke 179: 1kHz, Fluke 87V: 20 kHz, Brymen BM789: 100 kHz. An isolated oscilloscope (consider max. voltage) or a HV differential probe can help here.
One more thing: Did you happen to measure the waveform/peak voltage at this cap afterwards? Would give some peace of mind that the selected capacitor with its voltage rating is properly chosen. (I'm pretty confident it is...)
Thanks for watching! Yes you need to know the limits of your test equipment. I did check the voltage and waveform across the ceramic surface mount capacitor. It is a 94 KHz very narrow spike waveform with the spikes going to about 5 volts and it is riding on 3 volts DC. Note this is voltage across the cap, not referenced to ground, measured with a Fluke 199C isolated ground scopemeter.
Really very helpful diagnosis !
Glad you found the video helpful!
Excellent !, I love your videos, thanks .
Thanks for watching and glad you are enjoying my videos!