Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
Vložit
- čas přidán 24. 10. 2021
- #civilGuruji #civilengineerstraininginstitute #Training #Institute #Civil_Engineer #Slab #Checklist #Casting #Steel
Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
Start Your TRAINING NOW
Join this Training and get started :- civilguruji.com/s/store/cours...
For More Details Call Now : 9111001234
About This Video ------------------------------------------------------------------------------------
In this video Er. Akash Bohar, Corporate Trainer of Civil Guruji explaining about Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
A Reinforced concrete slab is horizontal members made of concrete which is used to resist the flexural bending stress when it is subjected to loads. Generally, the minimum thickness of the slab is 4 inches and the maximum thickness depends upon the span and loads acts on the slab. For Normal residential Building, 5 inches thickness is generally recommended. As we know that checking of slab reinforcement is very important. It is because the wrong layout of reinforcement on site creates a great loss for the client, so the first duties of a civil engineer to read the complete drawing of beam and Slab. The followings are a checklist of a concrete slab that needs to be carried before casting. Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
Check the diameter of Main Bars and Distribution along with Shorter Span as per approved drawings. Check the diameter of Main Bars and Distribution along with Longer Span as per approved drawings. pacing between Main Bar and Distribution along the Shorter span and longer span of slab as per approved drawings. Check the depth of the cover block as per structural drawings. Ensure that spacing between the cover block shall be at 1 m spacing. The depth or thickness of the slab should be checked.
A proper layout of chair Bars shall be provided for a slab.
Check the dowel bars, if provided for future extensions.
Make sure that the Main reinforcement of slab( both long span and short span) shall be passed through the beam in order to transfer loads of slab. Ensure that the reinforcement bar that is lapped should be located in a low-stress zone.
Proper lap length shall be checked for Main Bars. Check diameter and Spacing of Extra Reinforcement in Slab.
Check the dimension of the formwork of each slab panel.
The level and diagonal of each slab panel shall be checked.
Check the thickness of the slab.
Ensure the formworks shall provide all-round the slab edges, openings, etc.
Ensure the Support props of Slab should be in proper alignment and also check the plumb.
Vertical props or support of each slab panel shall be checked.
Make sure all the gaps in the formworks shall be properly sealed in order to prevent slurry leakage.
What an explanation!! Thank you
Dear sir
It is good information & valueable worthy
Pls do videos on Quality engineer
Thank you Gurooji
Very nice thank you So much sir
THANK YOU SIR
Sir Is There offline batches are available in bhopal currently .
Is the main bar of slab laid in shorter direction of the slab or shorter direction of building??
Superb explanation sir ji.....
Thankyou Sahil Solanki
Hame bahut khusi hai ki aapko hamari mehnat pasand aai , Civilguruji isi tarah civil engineers ko aage badhane ke liye mehnat karte rahega aur aap bhi knowledge dusro ko share karte rahe.
KEEP LEARNING, KEEP SHARING.
Thank you sir guruji 🙏
Discuss About Finishing Work And Gypsum Works
Wow sir U r the best Er in the world koi Aap se sikhe Explain karna❤️❤️
Thank you Mahesh 😊 keep sharing knowledge
please let me know how it's 8 Nos
good slab crank bar length at discontinued beam edge & at continued beam including length of crank bar as top bar after entering on adjacent slab #👍👍
Thank you vai🙏🙏
Topics -estimation of circular over head tank from excavation to top slab please sir
Thanks ☺️👍
Sir, 1st slab ka main bar dusre me bhi as a main bar nahi dalsakte ahi kya.
1000/100+1=11
Total length devided by space plus one
to find No.of bars
Great Sir ji
Sir aap bilding me plinth level par ek video lekar aao
Very nice information
Thank you
Thank you for explanations and as always very clear and meaningful information...
Can you plz kindly make one video on Reinforcement Bar Calculation from Foundation to next storey which shall maintain the lapping of next column...
Regards From Kathmandu, Nepal.
Shailesh Singh 🙏🙏🙏
Sailesh welcome👍 surely will make video soon on your demand.. Keep sharing
@@Civil_Guruji
Thank you for your kind reply... Actually want to join your certain courses and my priority is BBS... plz make me clear how do I make Payment as I am from Kathmandu Nepal...
Regards!🙏🙏🙏
1000/100+1=11
Total length devided by space plus one
to find No.of bars
sir good video ❤
Good
Sir offline training kab se start hoga
Can we use cover block in false ceiling?
Sir hmare 3-4 din m slab casting hone wali h. Aur beam bottom. Structure h. Beam 9×9 ka h. Tho isme steel bar kitna use kre. Double story h. Column size 9×14 hai total 20 column h. Kuch jagah column span 15 feet se jyada h. Unme beam m kya steel bar use kre.
Tekedar bolra h 12 mm ki 5 use krege. Kya ye G+1 k structure k hisab se shi h
11 no. Of bars
Sir chhatisgarh may co-operate course kb start ho re h
What about the binders spacing in extra bars ?
अगर क्रैंक बार लगा रहे हैं क्या तब भी चेयर बार देना चाहिए ??
Sir main bar longer span par hoga to kya problem hoga plz sir bataie
Offline training kb se start hogi
Grate sir
Thank you very much for your Love and Support . I appreciate your expression of support and goodwill. Let us continue to learn and share knowledge together.
good sir
Thanks and welcome @vipinpalmaths
No. Of bar = total length of bar/spacing +1
Minor bridge slab and footing under water flowing small river
Integrity steel Beam and column joint
Crank bar k bare me janna chata hu achha se
Check list for column n footing also
Will make in upcoming videos
2700 SQF house ka slab casting ke lye kitna bars chahiye sir?
Longer and shorter span ka size pahile nikalo then kuch formula ahe bar bending schedule hai usska use karke slab me kitne bars lagenge voh calculate hota hai
No. Of bars is 11 for every 1m. having 100 c/c
Bro 150
Cc 150 center to centre dia 50 over laping
Sir cantilever ke bare me bhi video banaao
Will make soon
10 Nos
Any branch in Bangalore
11 no of bars
Sir plz l batch for B.TECT
Sir form work foreman ka interview ka nalej ke bare me
Number of bars in 1 m of 100 mm spacing = 10 bars + 1 = 11 bars
+1 kyu ?
Sir hangars ghar 1300sq feet keep Ghar hai iske slabkeliye konsa saiz Ka bheem daalana chahiye our uskeliy kitane mm ka sariya use karanachagiye .haalkaa size hai 18feet length our 13feet width our bedroom law size hai 16feet Leigha our 13feet width hi .ye first florme hai our ground laval parking hai vaha 12puller deeya hai usame 12mm our 16mm kaa sariya use kiyahi plinth bhaim Me bi yahi sariya use kiya hai .Mara prasn hai ham kitane feet ka bhim daal saktehai our 20mmka sariya mai jaghahame daal saktehai kya. Dhanyawad sir.
11 no's of bar's
1000÷100=10 + 1=11bar
ZABARDAST G ♥️♥️♥️♥️♥️♥️♥️♥️♥️♥️
Thank you
Irfan Gul
Hame bohat khusi hai ki aapko hamari mehnat pasand aai , Civilguruji isi tarah civil engineers ko aage badane ke liye mehnat karte rahega aur aap bhi knowledge dusro ko share karte rahe.
KEEP LEARING, KEEP SHARING.
Sir slab ki steel kaise nikalte hai sir.
Sir Esme bendip kaha utha hua hai
Ok
Nos 10 number
Sir how much you earn?
Number of bar 10
In 1 m = 1000 mm
So in c/c spaceing is 100 mm so 1000÷100 = 10
So I think 10 steel will be
10 num of bars
Cops lifetime ke liye ek bar or laiye sir
Please call 9111001234 our team will help you.
1m main number of bar 11
11 nos.
1000÷100 = 10num of bars
Hello sir
11 bars
11
Correct
10 bars in 1 mtr..
1 m me 11 nos of bar aayenge
11 nos bar
10
1 m pe 10 bar
⭐⭐⭐⭐⭐
Dia dia 1.62
10/12 sabse pehele kahapar giregi iam mistri
Fit me bat Kara karo sir
7
11 nos
L 5
11 Bars for 100 specing
11 bar
10 bar
10+1=11
11 bar in 1 m
7 bars
Wrong sir
Main bar uper hoti h or distribution niche hoti h
Ek baar clear kar lijiye sir
Joni ji main bar slab me niche he hoti hai aur distribution bar uske upar
Doubt clear sir
Thank you sir 👍
Job bataiye
11 nos. Bar
Correct Shyamjeet
11nos
Everything aside, please do wear safety shoes at site , engineers must have safety concern to himself and people surrounding them. Safety should be a habit rather than a protocol...
Sir off-line coaching kab se start hogi
10
11
10 bar
11 bars
11 bar
Correct Sachin
10
11
11
11
Lawkesh correct ✅