    In this video Er. Akash Bohar, Corporate Trainer of Civil Guruji explaining about Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
    A Reinforced concrete slab is horizontal members made of concrete which is used to resist the flexural bending stress when it is subjected to loads. Generally, the minimum thickness of the slab is 4 inches and the maximum thickness depends upon the span and loads acts on the slab. For Normal residential Building, 5 inches thickness is generally recommended. As we know that checking of slab reinforcement is very important. It is because the wrong layout of reinforcement on site creates a great loss for the client, so the first duties of a civil engineer to read the complete drawing of beam and Slab. The followings are a checklist of a concrete slab that needs to be carried before casting. Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
    Slab Casting से पहले ये Steel ज़रूर Check करले | Site Engineer Basic Knowledge | Slab Checklist
    Check the diameter of Main Bars and Distribution along with Shorter Span as per approved drawings. Check the diameter of Main Bars and Distribution along with Longer Span as per approved drawings. pacing between Main Bar and Distribution along the Shorter span and longer span of slab as per approved drawings. Check the depth of the cover block as per structural drawings. Ensure that spacing between the cover block shall be at 1 m spacing. The depth or thickness of the slab should be checked.
    A proper layout of chair Bars shall be provided for a slab.
    Check the dowel bars, if provided for future extensions.
    Make sure that the Main reinforcement of slab( both long span and short span) shall be passed through the beam in order to transfer loads of slab. Ensure that the reinforcement bar that is lapped should be located in a low-stress zone.
    Proper lap length shall be checked for Main Bars. Check diameter and Spacing of Extra Reinforcement in Slab.
    Check the dimension of the formwork of each slab panel.
    The level and diagonal of each slab panel shall be checked.
    Check the thickness of the slab.
    Ensure the formworks shall provide all-round the slab edges, openings, etc.
    Ensure the Support props of Slab should be in proper alignment and also check the plumb.
    Vertical props or support of each slab panel shall be checked.
    Make sure all the gaps in the formworks shall be properly sealed in order to prevent slurry leakage.

Komentáře • 132

  • @subhankardutta6928
    @subhankardutta6928 Před 2 lety +3

    What an explanation!! Thank you

  • @praisethelord1828
    @praisethelord1828 Před 2 lety +1

    Dear sir
    It is good information & valueable worthy
    Pls do videos on Quality engineer

  • @jaysk.2862
    @jaysk.2862 Před 2 lety +2

    Thank you Gurooji

  • @dilsediltak6879
    @dilsediltak6879 Před 2 lety

    Very nice thank you So much sir

  • @SARTHAKGANJARE
    @SARTHAKGANJARE Před 2 lety +2

    THANK YOU SIR

  • @muzeebmadni6028
    @muzeebmadni6028 Před 2 lety +2

    Sir Is There offline batches are available in bhopal currently .

  • @EAGLE-ov8ui
    @EAGLE-ov8ui Před rokem +1

    Is the main bar of slab laid in shorter direction of the slab or shorter direction of building??

  • @sahilsolanki2246
    @sahilsolanki2246 Před rokem +1

    Superb explanation sir ji.....

    • @Civil_Guruji
      @Civil_Guruji  Před rokem

      Thankyou Sahil Solanki
      Hame bahut khusi hai ki aapko hamari mehnat pasand aai , Civilguruji isi tarah civil engineers ko aage badhane ke liye mehnat karte rahega aur aap bhi knowledge dusro ko share karte rahe.
      KEEP LEARNING, KEEP SHARING.

  • @kemitikahibitumaku
    @kemitikahibitumaku Před 5 měsíci

    Thank you sir guruji 🙏

  • @mohdmashood5685
    @mohdmashood5685 Před rokem

    Discuss About Finishing Work And Gypsum Works

  • @maheshnayak1512
    @maheshnayak1512 Před 2 lety +13

    Wow sir U r the best Er in the world koi Aap se sikhe Explain karna❤️❤️

    • @Civil_Guruji
      @Civil_Guruji  Před 2 lety +3

      Thank you Mahesh 😊 keep sharing knowledge

    • @rameshbs5595
      @rameshbs5595 Před rokem

      please let me know how it's 8 Nos

  • @ziauddin7948
    @ziauddin7948 Před rokem

    good slab crank bar length at discontinued beam edge & at continued beam including length of crank bar as top bar after entering on adjacent slab #👍👍

  • @manjumagar6540
    @manjumagar6540 Před rokem

    Thank you vai🙏🙏

  • @sahujainpremiereleague
    @sahujainpremiereleague Před 2 lety +1

    Topics -estimation of circular over head tank from excavation to top slab please sir

  • @syedhassan4570
    @syedhassan4570 Před 2 lety

    Thanks ☺️👍

  • @MasterTechWord
    @MasterTechWord Před 2 lety +1

    Sir, 1st slab ka main bar dusre me bhi as a main bar nahi dalsakte ahi kya.

  • @civilcknowledge6204
    @civilcknowledge6204 Před rokem +3

    1000/100+1=11
    Total length devided by space plus one
    to find No.of bars

  • @rakesharekar8776
    @rakesharekar8776 Před rokem

    Great Sir ji

  • @DurgeshKumar-nd2uf
    @DurgeshKumar-nd2uf Před 2 lety +2

    Sir aap bilding me plinth level par ek video lekar aao

  • @erkundanyadav
    @erkundanyadav Před 2 lety

    Very nice information

  • @saileshsingh1
    @saileshsingh1 Před 2 lety +4

    Thank you for explanations and as always very clear and meaningful information...
    Can you plz kindly make one video on Reinforcement Bar Calculation from Foundation to next storey which shall maintain the lapping of next column...
    Regards From Kathmandu, Nepal.
    Shailesh Singh 🙏🙏🙏

    • @Civil_Guruji
      @Civil_Guruji  Před 2 lety

      Sailesh welcome👍 surely will make video soon on your demand.. Keep sharing

    • @saileshsingh1
      @saileshsingh1 Před 2 lety

      @@Civil_Guruji
      Thank you for your kind reply... Actually want to join your certain courses and my priority is BBS... plz make me clear how do I make Payment as I am from Kathmandu Nepal...
      Regards!🙏🙏🙏

  • @gyancivil1
    @gyancivil1 Před měsícem

    1000/100+1=11
    Total length devided by space plus one
    to find No.of bars
    sir good video ❤

  • @lakshmansingh3865
    @lakshmansingh3865 Před rokem

    Good

  • @mohdshahid1330
    @mohdshahid1330 Před 2 lety +1

    Sir offline training kab se start hoga

  • @ramakantasenapati660
    @ramakantasenapati660 Před 7 měsíci

    Can we use cover block in false ceiling?

  • @builttolast5249
    @builttolast5249 Před rokem

    Sir hmare 3-4 din m slab casting hone wali h. Aur beam bottom. Structure h. Beam 9×9 ka h. Tho isme steel bar kitna use kre. Double story h. Column size 9×14 hai total 20 column h. Kuch jagah column span 15 feet se jyada h. Unme beam m kya steel bar use kre.
    Tekedar bolra h 12 mm ki 5 use krege. Kya ye G+1 k structure k hisab se shi h

  • @utkarshgoel7873
    @utkarshgoel7873 Před 2 lety

    11 no. Of bars

  • @ideapadgaming1164
    @ideapadgaming1164 Před 2 lety

    Sir chhatisgarh may co-operate course kb start ho re h

  • @avneetpatel5175
    @avneetpatel5175 Před 19 dny

    What about the binders spacing in extra bars ?

  • @pra20011983
    @pra20011983 Před 10 měsíci +1

    अगर क्रैंक बार लगा रहे हैं क्या तब भी चेयर बार देना चाहिए ??

  • @balaramacharya8640
    @balaramacharya8640 Před rokem

    Sir main bar longer span par hoga to kya problem hoga plz sir bataie

  • @SANDEEPKUMAR-mh4we
    @SANDEEPKUMAR-mh4we Před 2 lety +1

    Offline training kb se start hogi

  • @user-cr2np7hn6o
    @user-cr2np7hn6o Před 2 měsíci +1

    Grate sir

    • @Civil_Guruji
      @Civil_Guruji  Před 2 měsíci

      Thank you very much for your Love and Support . I appreciate your expression of support and goodwill. Let us continue to learn and share knowledge together.

  • @vipinpalmaths
    @vipinpalmaths Před 8 měsíci +1

    good sir

  • @dheerendrashukla7551
    @dheerendrashukla7551 Před rokem +1

    No. Of bar = total length of bar/spacing +1

  • @premchand-ww4ie
    @premchand-ww4ie Před 2 lety

    Minor bridge slab and footing under water flowing small river

  • @utkarshgoel7873
    @utkarshgoel7873 Před 2 lety

    Integrity steel Beam and column joint

  • @civil.99
    @civil.99 Před 2 lety

    Crank bar k bare me janna chata hu achha se

  • @Knowledgeaboutallll
    @Knowledgeaboutallll Před 2 lety

    Check list for column n footing also

  • @t.ngotan9680
    @t.ngotan9680 Před měsícem +1

    2700 SQF house ka slab casting ke lye kitna bars chahiye sir?

    • @rishikeshdudhe8122
      @rishikeshdudhe8122 Před měsícem

      Longer and shorter span ka size pahile nikalo then kuch formula ahe bar bending schedule hai usska use karke slab me kitne bars lagenge voh calculate hota hai

  • @MdFaizan-pe5hn
    @MdFaizan-pe5hn Před 2 lety +4

    No. Of bars is 11 for every 1m. having 100 c/c

  • @MOHAMMADASIF-un1tq
    @MOHAMMADASIF-un1tq Před 2 lety

    Sir cantilever ke bare me bhi video banaao

  • @rameshbs5595
    @rameshbs5595 Před rokem

    10 Nos

  • @sadikkilledar8484
    @sadikkilledar8484 Před 5 měsíci

    Any branch in Bangalore

  • @shrinivashosamani1935
    @shrinivashosamani1935 Před 2 lety

    11 no of bars

  • @gyamgio_5829
    @gyamgio_5829 Před 2 lety

    Sir plz l batch for B.TECT

  • @rakeshrakes5558
    @rakeshrakes5558 Před 2 lety

    Sir form work foreman ka interview ka nalej ke bare me

  • @sahilbagave7708
    @sahilbagave7708 Před 2 lety +2

    Number of bars in 1 m of 100 mm spacing = 10 bars + 1 = 11 bars

  • @rachayyas3529
    @rachayyas3529 Před rokem

    Sir hangars ghar 1300sq feet keep Ghar hai iske slabkeliye konsa saiz Ka bheem daalana chahiye our uskeliy kitane mm ka sariya use karanachagiye .haalkaa size hai 18feet length our 13feet width our bedroom law size hai 16feet Leigha our 13feet width hi .ye first florme hai our ground laval parking hai vaha 12puller deeya hai usame 12mm our 16mm kaa sariya use kiyahi plinth bhaim Me bi yahi sariya use kiya hai .Mara prasn hai ham kitane feet ka bhim daal saktehai our 20mmka sariya mai jaghahame daal saktehai kya. Dhanyawad sir.

  • @shaikyousufbasha3287
    @shaikyousufbasha3287 Před 2 lety

    11 no's of bar's

  • @noorain27
    @noorain27 Před 2 lety +1

    1000÷100=10 + 1=11bar

  • @irfangul4345
    @irfangul4345 Před rokem +1

    ZABARDAST G ♥️♥️♥️♥️♥️♥️♥️♥️♥️♥️

    • @Civil_Guruji
      @Civil_Guruji  Před rokem

      Thank you
      Irfan Gul
      Hame bohat khusi hai ki aapko hamari mehnat pasand aai , Civilguruji isi tarah civil engineers ko aage badane ke liye mehnat karte rahega aur aap bhi knowledge dusro ko share karte rahe.
      KEEP LEARING, KEEP SHARING.

  • @tilaksahu4873
    @tilaksahu4873 Před rokem

    Sir slab ki steel kaise nikalte hai sir.

  • @ajayahir740
    @ajayahir740 Před 4 měsíci

    Sir Esme bendip kaha utha hua hai

  • @PANKAJKUMAR-je4pk
    @PANKAJKUMAR-je4pk Před 2 lety

    Ok

  • @furquanahmad87
    @furquanahmad87 Před 2 lety

    Nos 10 number

  • @sumitbhute1042
    @sumitbhute1042 Před 2 lety +1

    Sir how much you earn?

  • @haideraliidrishi6637
    @haideraliidrishi6637 Před rokem

    Number of bar 10

  • @behappy2901
    @behappy2901 Před rokem

    In 1 m = 1000 mm
    So in c/c spaceing is 100 mm so 1000÷100 = 10
    So I think 10 steel will be

  • @mdbelal37db64
    @mdbelal37db64 Před rokem

    10 num of bars

  • @mrkumar4404
    @mrkumar4404 Před rokem +1

    Cops lifetime ke liye ek bar or laiye sir

    • @Civil_Guruji
      @Civil_Guruji  Před rokem

      Please call 9111001234 our team will help you.

  • @sandeeppatta7869
    @sandeeppatta7869 Před 10 měsíci

    1m main number of bar 11

  • @MasterTechWord
    @MasterTechWord Před 2 lety

    11 nos.

  • @mdbelal37db64
    @mdbelal37db64 Před rokem

    1000÷100 = 10num of bars

  • @tilaksahu4873
    @tilaksahu4873 Před rokem

    Hello sir

  • @meraindia5367
    @meraindia5367 Před 7 měsíci +1

    11 bars

  • @j.fconstructioncnsltnt1553

    11

  • @MrPrafulyadav
    @MrPrafulyadav Před 4 měsíci +1

    10 bars in 1 mtr..

  • @omprakashmahawar5883
    @omprakashmahawar5883 Před 2 lety

    1 m me 11 nos of bar aayenge

  • @faiyyajshaikh1110
    @faiyyajshaikh1110 Před 2 lety

    11 nos bar

  • @amankumarprajapati7509

    10

  • @amansomkuwar9958
    @amansomkuwar9958 Před 5 měsíci

    1 m pe 10 bar

  • @faisalqureshi9287
    @faisalqureshi9287 Před 2 lety +1

    ⭐⭐⭐⭐⭐

  • @KuldeepKumar-do9wu
    @KuldeepKumar-do9wu Před 10 měsíci

    Dia dia 1.62

  • @romjansk6414
    @romjansk6414 Před rokem

    10/12 sabse pehele kahapar giregi iam mistri

  • @SameerShaikh-zn4gh
    @SameerShaikh-zn4gh Před rokem

    Fit me bat Kara karo sir

  • @rajprajapat5597
    @rajprajapat5597 Před 2 lety

    7

  • @SunilRajput-eo9fs
    @SunilRajput-eo9fs Před rokem

    11 nos

  • @kabiulkhan282
    @kabiulkhan282 Před 2 lety

    L 5

  • @nirmanroy9689
    @nirmanroy9689 Před 2 lety

    11 Bars for 100 specing

  • @RajanSingh-vq2zu
    @RajanSingh-vq2zu Před 2 lety

    11 bar

  • @43_rushikeshpatil35
    @43_rushikeshpatil35 Před 2 lety

    10 bar

  • @braj596
    @braj596 Před 2 lety

    10+1=11

  • @Sk-dq4im
    @Sk-dq4im Před 2 lety

    11 bar in 1 m

  • @abuzain1038
    @abuzain1038 Před 2 lety

    7 bars

  • @joniverma2743
    @joniverma2743 Před 2 lety +1

    Wrong sir
    Main bar uper hoti h or distribution niche hoti h
    Ek baar clear kar lijiye sir

    • @Civil_Guruji
      @Civil_Guruji  Před 2 lety +3

      Joni ji main bar slab me niche he hoti hai aur distribution bar uske upar

    • @joniverma2743
      @joniverma2743 Před 2 lety

      Doubt clear sir
      Thank you sir 👍

  • @nitishbhandarkar7733
    @nitishbhandarkar7733 Před 2 lety

    Job bataiye

  • @shyamjeetchauhan2142
    @shyamjeetchauhan2142 Před 2 lety +2

    11 nos. Bar

  • @sukantamandal3025
    @sukantamandal3025 Před rokem

    11nos

  • @1356abhi
    @1356abhi Před rokem

    Everything aside, please do wear safety shoes at site , engineers must have safety concern to himself and people surrounding them. Safety should be a habit rather than a protocol...

  • @sunilkumargupta1984
    @sunilkumargupta1984 Před 2 lety

    Sir off-line coaching kab se start hogi

  • @vikramsinghrathore5112
    @vikramsinghrathore5112 Před 8 měsíci

    10

  • @deepakankushe9833
    @deepakankushe9833 Před 11 měsíci

    11

  • @parshuramchothe3439
    @parshuramchothe3439 Před rokem

    10 bar

  • @riteshraj981
    @riteshraj981 Před rokem

    11 bars

  • @SachinYadav-on2ff
    @SachinYadav-on2ff Před 2 lety +1

    11 bar

  • @vijendraarya5855
    @vijendraarya5855 Před 10 dny

    10

  • @civilengineer8018
    @civilengineer8018 Před 3 měsíci

    11

  • @virendraramteke6524
    @virendraramteke6524 Před měsícem

    11

  • @lawkeshthombare1454
    @lawkeshthombare1454 Před 2 lety +2

    11