अमृतधारा, माय अस्पताल में मरीज़ो की सुरक्षा के लिए अग्निशमन अभ्यास (fire mock drill) किया गया। आज जानिए की आग बुझाने का नल (fire hose) व अग्निशामक (fire extinguisher ) को किस तरह इस्तेमाल किया जाता है
1. Before adequately holding the nozzle of fire hose , don't try to open the valve , it may cause of fatal injury while hitting to body . 2. Don't stay infront of hydrant point while opening the valve of hydrant , accidently when disconnect it may also cause of injury. 3. While introducing about the fire fighting equipments use a proper ppe such as hand gloves , safety shoes , safety glass and hard hat .
Sir hose pipe aur nozzle kaise pakadna hi aapne uss bande ko bole nhi,nhi pressure se pura Hose hilta,aur kisiko lg jaata,aise condition pe mout bi ho Sakti hi,aur valve open karne se pehle pehle,are u ready ,krke puchiye use,thank you ,stay alert ,be safe ,🙏
Good morning sir ji jis tarha sey fire hose pipe logo ney pakda hai wo galet tarika hai is tarha sey teg paresar honey ya chodney par Noel chut sakta hai raght tarika batao sabhi ko
Kindly tell me about expire date of foam ,Co2 , automatic fire extinguishers and powder.after how many times they are expire...and kindly send me price details of same.
Class A - fires involving solid materials such as wood, paper or textiles. Class B - fires involving flammable liquids such as petrol, diesel or oils. Class C - fires involving gases. Class D - fires involving metals. Class E - fires involving live electrical apparatus
Class A mein foam, water, aur dry powder use kr skte hai, B mein Foam and co2. E mein co2, expect sabh mein powder use kr skte hai, class f mein shyd wet chemical use hota hai, powder har trah k fire pr chl jata hai
सर जी आपने ट्रैनिंग देने का प्रयास तो अच्छा किया हैं ।किंतु आप बहुत ही अधूरा ज्ञान दे रहे हैं आप ने न ही Classification of fire न ही type of Extinguisher और न ही तरीका से Extinguisher Operation को बताया और न ही hose (पाईप) and Branch (नोजल) को पकड़ने का सही तरीका बताया जिससे लोगो को चोट व जान भी जा सकती हैं। इस लिये आप लोगो से निवेदन हैं सही जानकारी देवे, व सही जानकारी के साथ ही फायर एक्सटिंगईशेर व होज पाईपों का इस्तेमाल करें
Totally wrong... Fire extinguisher ko ground per rakkar thodasa bend karke 3 meter gap se use karna chahiye.. Aur aapka ppe kaha hy saab....emergency numbers fire ambulance medical jagah jagah lagaani chahiye..
Worth to watch. Thnx for learning us too good thing while emergencies
Knew something today which is quite helpfull...👍👍👍
did not knew about ABC kind of fire. last part was something new to me. i would buy ABC type
You can buy ABC but specially you can't use liquor store and liquid area .
Bhut achi
1. Before adequately holding the nozzle of fire hose , don't try to open the valve , it may cause of fatal injury while hitting to body .
2. Don't stay infront of hydrant point while opening the valve of hydrant , accidently when disconnect it may also cause of injury.
3. While introducing about the fire fighting equipments use a proper ppe such as hand gloves , safety shoes , safety glass and hard hat .
Ryt
Very Informative
Thanks sir for this lesson 🙏
Aap jo extinghusher use kra rahe hai o konsa hai aabi drill ko
seafarers are very smart in firefighting...hit like seafarers
Fantastic sir
Outgo
Mast...
Is this is the right position to hold the fire reel pipe... its wrong
Trainer not properly trained; opened the hydrant valve fastly putting branch men at Risk & the way he explained how the branch is held.
Right
czcams.com/video/kmqqPKRivqg/video.html
Thank you sir, I learn this
very nice
thank you sir
nice
Fire righting ka kam norms ke acording nahi huwa hai..butterfly walve kahan hai sir..
Good
best. price. and. lowest. rates Fire extinguisher available
why do these drill videos come from india in youtube?
Good job
Not proper training Hose pipe ko ese khali karte he kya (wrong)
Sir hose pipe aur nozzle kaise pakadna hi aapne uss bande ko bole nhi,nhi pressure se pura Hose hilta,aur kisiko lg jaata,aise condition pe mout bi ho Sakti hi,aur valve open karne se pehle pehle,are u ready ,krke puchiye use,thank you ,stay alert ,be safe ,🙏
How to open the fire extinguisher ?
right
good
Sir ap ka idara kaha ha mein experince k liye awonga mein safety studnt ho..plz help me
mast h
Tq sir
Nice
Co2 extinguisher ki jagah ABC extinguisher karke trainig de rahe ho Sir...
Hamm chalaye h to chhodne ke baad hava nikal rha h kya kare btaye
Thank you
Sir hydrants operate krte samay saamne khade nhi hote h
Sir petrol disel or baki k liye foam wala extingusher hota hai jo disel or petrol ki aag ko bujhane k liye use main liya jata hai
best
Sir isme safety instrument to hai hi nahi agar hmare pass suraksha yantra hi nahi h to suraksha kis se krenge.
Best knownlage
sir I think this is wrong...if you don't mind..tell them properly how to use DHV system..otherwise somebody injured by brance pipe
Es video me Fire Hydrant ka hose holding position wrong bataya gya hai.
Trainer se request h ki students ko wrong posture na bataye...
Thinkyou sir
Branch rong pakde hai ji please sahi se pakdo nehi to चोट लग जाएगी
agi branch to pakdni bata dete enhe or aapne unko es important cheej ko chod diya enko branch pakdna ka acha tarika batao
Good morning sir
Esh fireman ko koe batao ki nozal pakdne ka sahi tarika kya ye to jaan le lega kisi ki
😍😍😍👍👍👍👍👍🔵🔴🔵🔴
Pakadh ki sistam bataye sir ji
Sir mere pass two years ka experience hai
ham Nisa ham aise nahi sikhe hai sir pls sahi tarika bataye
Sir kbhi bhi CO2 ka extinguisher chalane se phle uska hukk pkdte h hose nhi sir ji
Jay hind
Way hose was hold is dangerous
dear sir,
fire hydrant nozzle and hose pipe handling method is wrong is a over presser water
thinks
Dear sir..
Branch Aisi nahi kado jati..7kg..Pressure doge to Uper jayegi
Sir phele phimel ko haat se pkd kr apne se upr uttana pdta h tb usko khali krte h sir ji
Good morning sir ji jis tarha sey fire hose pipe logo ney pakda hai wo galet tarika hai is tarha sey teg paresar honey ya chodney par Noel chut sakta hai raght tarika batao sabhi ko
Kindly tell me about expire date of foam ,Co2 , automatic fire extinguishers and powder.after how many times they are expire...and kindly send me price details of same.
We are not sellers, therefore please enquire about the cost with the sellers.
ATA Jata kuchnai hydrant nozzle Aise nahi used Kiya jatahye bhai
SR g or fire ke bare m video Bana do please
thanks
Bahali kab hai es bhakaishi
Sir that is wrong method handling of Branch it's big reason for accident
And 4 class of fire A,B,C,D according to standard
According to UK 5 classes
Thanks for the feedback Mr. Dyanand
Class A - fires involving solid materials such as wood, paper or textiles.
Class B - fires involving flammable liquids such as petrol, diesel or oils.
Class C - fires involving gases.
Class D - fires involving metals.
Class E - fires involving live electrical apparatus
Kuch countries mein class f bhi hai Class F - fires involving cooking oils such as in deep-fat fryers.
Class A mein foam, water, aur dry powder use kr skte hai, B mein Foam and co2. E mein co2, expect sabh mein powder use kr skte hai, class f mein shyd wet chemical use hota hai, powder har trah k fire pr chl jata hai
fire p pany nhi dalna chahiye abcdry pawder use karna chahiye
Fire line flushing to kr lete sir
सर जी आपने ट्रैनिंग देने का प्रयास तो अच्छा किया हैं ।किंतु आप बहुत ही अधूरा ज्ञान दे रहे हैं आप ने न ही Classification of fire न ही type of Extinguisher और न ही तरीका से Extinguisher Operation को बताया और न ही hose (पाईप) and Branch (नोजल) को पकड़ने का सही तरीका बताया जिससे लोगो को चोट व जान भी जा सकती हैं।
इस लिये आप लोगो से निवेदन हैं सही जानकारी देवे, व सही जानकारी के साथ ही फायर एक्सटिंगईशेर व होज पाईपों का इस्तेमाल करें
आपके और बच्चों के लिए 👇 Subscribe now! 👆🧍🧍🧍🧍🧍🧍🧍
czcams.com/video/Ktnzb921BdM/video.html
#Childsafety #Ranveersingh #Schoolsafety
#Firesafetyclasses
Its not a cylinder its a fire extinguisher sir
Instructor not properly train
Hi
It's a very wrong way to hold the branch...It may cause a serious injury
Bhai Saab diploma banvana s....btao
Ban jayega jee haryana se ITI se. 9053304980
संर जी आपने नोजल पकड ने का तरिका बराबर नहीं बताया और pass कि प्रकिया भी नाही बताई
Dlf plaza towér
Shut of branch ko holding Ka Tarika galat hai Sir....
Rong branch holding
Sir ji Nozol pakdane Ka Tarika golot he sir ji
70%ok
harendra m
branch pipe holding method is wrong
for extinguishers we have to use pass method
Sir ji fire ka jo nozzal h wo pakdne ka tarika galat h
Nozzle to pakdne ache se shikao sir
sir branch pakdne ka tatika galat he apka
Class d is metal fire
sir apke pas security gaud ja job milega
contact on this number 01844098603
Hose pipe pakdne ka tarika apne galat batya sir
Pehele apna safety
Vedio puri banate
Don't mind sir. First you know how to use the fire fighting devices. then do it. It's completely wrong method.
Obviously you r saying right, wrong training, fire fighting hose handled totally wrong
Iam not certify in this training
Jo naujal pakdane Ka Tarika apnaya Hai aapane ismein Se Jaan Bhi Ja sakti hai sar pakdane ka tarika thoda alag hai
Hello Sir Fire trenning shi dijiye Sir jis trh aap bta rhe h Sir please ye glt h hydrent jo pakana h bh glt h hose pipe se pani nikanana glt h
Totally wrong...
Fire extinguisher ko ground per rakkar thodasa bend karke 3 meter gap se use karna chahiye..
Aur aapka ppe kaha hy saab....emergency numbers fire ambulance medical jagah jagah lagaani chahiye..
Industrial safety engineering lectures.
Lecture-1. Introduction to Industrial Safety Engineering. czcams.com/video/ZHO3J5ry-lo/video.html
Lecture-2. Key concepts and terminologies. czcams.com/video/e8CoR_jv5Us/video.html
Lecture-3. Key concepts and terminologies-Safety domain ontology. czcams.com/video/6JcFkrPtkMA/video.html
Lecture-4. Key concepts and terminologies-Risk Assessment & Control. czcams.com/video/3wq0RXQoI84/video.html
Lecture-5. Safety Engineering & Accident causing mechanisms. czcams.com/video/Q_veegUkjCs/video.html
Lecture-6. Preliminary Hazard List. czcams.com/video/h6NSpupWR4I/video.html
Lecture-7. Preliminary Hazard Analysis. czcams.com/video/5B7eeuGbOiE/video.html
Lecture-8. Hazard and operability study (HAZOP) czcams.com/video/y1zGxalGL5w/video.html
Lecture-9. (FMEA)- Identification of Failure Modes. czcams.com/video/nDhp-TaJyFc/video.html
Lecture-10. Failure Modes and Effects Analysis (FMEA)-Continue. czcams.com/video/TAnPlzMHii4/video.html
Lecture-11. Application of Hazard Identification Techniques. czcams.com/video/l-eZXTmieUY/video.html
Lecture-12. FAULT TREE ANALYSIS (FTA)- Construction. czcams.com/video/7oKiCAR7ohI/video.html
Lecture-13. FAULT TREE ANALYSIS (FTA)- Gate by Gate method. czcams.com/video/VkPnzhpfSsk/video.html
Lecture-14. FAULT TREE ANALYSIS (FTA)- Cut-set method. czcams.com/video/SGBQtnYA1VE/video.html
Lecture-15. EVENT TREE ANALYSIS (ETA). ok. czcams.com/video/J7tnFOZtM-c/video.html
Lecture-16. FAULT TREE ANALYSIS (FTA) Importance measures. czcams.com/video/boUgDFBKfC0/video.html
Lecture-17. Bow-tie. czcams.com/video/SNfSbse9ivY/video.html
Lecture-18. Bow-tie_ Common Cause Cut Sets. czcams.com/video/8PhveicMkWU/video.html
Lecture-19. Bow-tie_ Cut-sets for Accident Scenarios. czcams.com/video/AZe6GVJNqz0/video.html
Lecture-20. Bow-tie_ Cut-sets for Accident Scenarios (Cont.) czcams.com/video/YGdPRmOkGNE/video.html
Lecture-21. Bow-tie_ Identification of Safety Barriers. czcams.com/video/J2tK0_icemw/video.html
Lecture-22. Risk assessment, risk management system. czcams.com/video/YDw97riGzrk/video.html
Lecture-23. Consequences assessment czcams.com/video/07BoNl6Th44/video.html
Lecture-24. Energy control model and Hazard control hierarchy czcams.com/video/ENpFXj9yiMM/video.html
Lecture-25. Safety function deployment czcams.com/video/m3QuZ7c0ZuQ/video.html
Lecture-26. Ranking of design solutions. AHP approach czcams.com/video/AzfJy_8ZAcI/video.html
Lecture-27. Quantification of basic events for Non - repairable components czcams.com/video/udgyZ-PA6ds/video.html
Lecture-28. Qualification of Basic events - Hazard rate. What is IFR, CFR and DFR. czcams.com/video/xpacBhN8U9w/video.html
Lecture-29. Quantification of basic events- Exponential distribution czcams.com/video/4A8204-jWp8/video.html
Lecture-30. Quantification of Basic events- weibull Distribution. Parameter estimation from graphical czcams.com/video/JOKCWE9oBBg/video.html
A Class - water
B Class- M.Foam
C Class- CO2
D Class - DCP
Electric fire cut off fire - CO2
Don't play with fire hose it will give severe injury
The way that staff is holding the branch is wrong
Sir ji pakdane ka apka tarika galat he
Right sir
Hose handled totally wrong
Sahi pakde h
Sahi bole aap
Sir hoj pakdne ka trika bilkul glt h aap bta rhe ho us trike se hoj biranch sir me aakr lge ga
Wrong method of holding branch.