Optical Coherence Tomography Basic Explanation

Sdílet
Vložit
  • čas přidán 27. 07. 2024
  • A very introductory look at Optical Coherence Tomography (OCT), an imaging technology used in medicine.

Komentáře • 57

  • @linafessi67
    @linafessi67 Před 4 měsíci +4

    This litterally the best video i saw on youtube to understand what OCT is, in a more physical way. Thank you soooo much!!

  • @JoelSchuman
    @JoelSchuman Před 9 lety

    Nice work Zach! We're looking forward to great things!

  • @linamarcelapinedagutierrez4650

    Thank you for the tutorial, it has helped me a lot since it was kind of hard to understand this written on a book.

  • @anjham
    @anjham Před 6 lety

    outstanding and to the point.
    well done zach

  • @davidmusoke
    @davidmusoke Před 5 lety

    Great tutorial Zach. Thank you!

  • @samanmonazami9156
    @samanmonazami9156 Před 5 lety

    Nicely explained! Thanks Zach!

  • @warnacokelat
    @warnacokelat Před 8 lety

    Saved me a lot of trouble. Thanks a lot.

  • @Rzapata14
    @Rzapata14 Před rokem

    Amazing! thank you for sharing with us.

  • @acousp4515
    @acousp4515 Před 4 lety +6

    What a perfect mouse control!

  • @MrWabouz
    @MrWabouz Před 4 lety +28

    Too bad you rushed it in the end... I'm familiar with Michelson interferometery but you really went to quickly on the reason why I clicked on this video: explaining exactly how we build the image layer by layer...

  • @anthonyphan4036
    @anthonyphan4036 Před 7 lety +9

    Great Video! Could you make one on Swept Source OCT?

  • @anooptiwari2011
    @anooptiwari2011 Před 2 lety

    Simplified !! Good work. Thanks too.

  • @yandai6253
    @yandai6253 Před 2 lety

    Thanks a lot. It is a gerat introduction for OCT.

  • @MsHilol92
    @MsHilol92 Před 8 lety

    awesome explanation thank you!!!

  • @gsonwu475
    @gsonwu475 Před 2 lety

    Nice video! You explain the principales of OCT much better than my teachers hhh

  • @nathanclin70
    @nathanclin70 Před 7 lety

    Great explanation. Could you talk about the Spectral Domain OCT?

  • @nadarasarbahavan6269
    @nadarasarbahavan6269 Před 5 lety

    Brilliant! Subscribed.

  • @SidneyCrosbyGOAT
    @SidneyCrosbyGOAT Před 9 lety

    Great stuff!!!

  • @majdhaddad6184
    @majdhaddad6184 Před 3 lety

    Thank you very muck this really did help me a lot❤

  • @HarishSasikumar
    @HarishSasikumar Před 8 lety +1

    Great tutorial :)

  • @kazzie1998
    @kazzie1998 Před 7 lety +1

    Great video! I really understand TD-OCT now, but could you explain how FD-OCT works? i can't really grasp how that would be implemented in this system. Do you detect all photons with different frequencies? How would different path lengths affect these numbers? I hope you read this!

  • @alighazi6352
    @alighazi6352 Před 6 lety +1

    great lecture

  • @nc956
    @nc956 Před 10 měsíci

    Great video - thanks !

  • @nertev8731
    @nertev8731 Před 2 lety

    Thank you,it's a great video

  • @gokhangokdogan
    @gokhangokdogan Před 6 lety

    When we send red and orange light together, will the beamsplitter split the red light to object (or mirror) and the orange light to mirror (or object) ?

  • @sevadahakobyan504
    @sevadahakobyan504 Před 7 lety

    Thanks for sharing.

  • @gokhangokdogan
    @gokhangokdogan Před 6 lety

    If we mention the 4th case for L1 and L2 distances, L1 is not equal L2, but the difference between them is not lamda/2. What happens?

  • @nesrineogab5885
    @nesrineogab5885 Před 2 lety

    amazing!! god bless you

  • @seshachary5580
    @seshachary5580 Před 2 lety

    very educative. thank you regards

  • @rokeyamumtahanamou6188

    how do we adjust the mirror for the next layer?in this video for example the green layer.I understood for L1=L2 we see blue but how do we see for green layer?
    Thnaks in advance

  • @seshachary5580
    @seshachary5580 Před 6 lety

    Thank you regards

  • @mounirtighilt6348
    @mounirtighilt6348 Před 3 lety

    can u do a video explaining the OCT FD and OCT time domain?

  • @charliefreundlich7963
    @charliefreundlich7963 Před 8 lety +2

    I am just learning about this, but I think the speaker misspoke at around 18:30. He said the coherence has to do with the difference between L1 and L2. Actually, the coherence length cares about the magnitudes of L1 and L2. As long as both L1 and L2 are less than the coherence length, you can still make reasonable observations regarding interference when the are varied by some small delta, provided that L2+delta is less than the coherence length as well.

    • @zachnadler1914
      @zachnadler1914  Před 8 lety +1

      +Charlie Freundlich Hey Charlie, thanks for the comment. I agree that I wasn't very clear on this point, so hopefully I can help with the confusion. The coherence length actually doesn't specifically deal with the L1 or L2 distances. Coherence in the context of light really deals with the ability of light to interfere. For instance, using a Michelson interferometer in the case of a laser (a perfectly coherent source) we can send half the beam a very large distance (ie L1=10m) and the second part a very short distance (ie L2=3mm) and there will still be interference because the laser uses light of very narrow bandwidth (the delta lamda in the equation at 20:15). However, when we have a light source with a broader bandwidth (with orange light as well as red) the coherence length shortens. In that situation there is only interference when the path length difference between the two legs is smaller than the coherence length. All this said, if L1 and L2 are shorter than the coherence length you are correct, there will be interference. Generally speaking, L1 and L2 are much longer than the coherence length which might only be a couple of microns. Thanks again! Let me know if there is further confusion.

    • @siddharthrawat7205
      @siddharthrawat7205 Před 8 lety

      also the fringe contrast depends upon the magnitude of intensity values reflected from the two arms, one can adjust it by using OD filters or by putting a glass slide instead of a mirror assuming that you sample is on a glass slide too in the other arm if you don't want to use ODs to complicate the system

    • @inaugurated
      @inaugurated Před 5 lety

      @@zachnadler1914 I was also really confused about this and had the same thought that L1 and L2 had to be shorter than the coherence length. But I get it now. Even though L1 and L2 are larger than the coherence length and the individual light beams may not be coherent anymore, the phase shifts between the red and orange waves are still (almost) the same for L1 and L2 as long as the path length difference is within the coherence length. As long as the phase shift between red and orange is the same for the interfering beams, an interference pattern will emerge.

  • @lambda4931
    @lambda4931 Před 5 měsíci

    Thank you!

  • @sheetalsharma1996
    @sheetalsharma1996 Před 6 lety

    Very informative

  • @maxkotlarchyk4242
    @maxkotlarchyk4242 Před 8 lety +4

    Hi Zach. Decent very beginner video but I think it may be misleading to most because you are talking about versions of OCT which are no longer used. All current systems work in the spectral domain, require long coherence length, and have no scanning mirror. Most modern ones sweep the laser source to achieve an artificially large bandwidth and fine resolution. The A-scan information is recovered from the fourier transform of the fringes. To me the most difficult thing to grasp is the relation between bandwidth, coherence autocorrelation, and resolution... i.e. why sweeping through multiple wavelengths gives you higher resolution.

    • @MrObear
      @MrObear Před 6 měsíci

      Max, do you have a link that explains how the current systems work?

  • @viraj__shah
    @viraj__shah Před 9 lety +2

    Great video. I have a couple of follow up questions.
    1) I'm not sure I understood why the addition of "extra" frequencies (larger bandwidth light source) solved the picosecond laser/monochromatic issue (i.e. that picosecond lasers are too expensive). Is it just that a pulsed light source that isn't as spatially coherent as a monochromatic laser is much cheaper and that you can get away with a light source that has a reasonable coherent length?
    2) Let's say you want to get L1 to equal L2. I imagine you can just calibrate until you see a bright spot. L1 might not be equal to L2 but you know that they are integer half wavelength in difference. Is this correct? Or are you able to move these within

    • @zachnadler1914
      @zachnadler1914  Před 9 lety +3

      Viraj Shah Great questions! Not sure I can adequately answer them in a comment but, I will try...
      1. I was a little confused on this question. The broader the bandwidth of the light source equals a smaller the coherence length (and by extension finer axial resolution). Interference of light between the two legs of the interferometer only occurs when the path length of light traveled by one leg is within one coherence length of the distance traveled by the other leg. In regards to the femtosecond laser, one of the primary limitations I didn't mention is that the sensitivity of these sources are not great enough for biological tissues and can be 1000x less than the broad bandwidth sources.
      2. Because the interference occurs within a coherence length you can bring the optical path lengths of the two legs to within tens of microns of one another just by observing interference and technically even closer than that. My engineering background is limited so I don't have a great answer for you in terms of the mechanism for scanning. Probably somewhat system dependent but galvos, resonant scanners and stepper motors sound good to me. One thing I left out is that the moving reference mirror was used in the original systems (called Time Domain OCT) but newer technology (Spectral Domain OCT) leverages a fourier transform to replace the moving reference mirror. These systems are faster and less susceptible to noise so most common commercial systems use SDOCT. Maybe I'll make a video detailing that technology.
      Thanks for the questions! Let me know if I can help any further!

    • @viraj__shah
      @viraj__shah Před 9 lety

      Zach Nadler This is great and very helpful. Thank you!

  • @RoentgenChernobyl
    @RoentgenChernobyl Před 2 lety

    Thank you.

  • @sowmyanandipati5359
    @sowmyanandipati5359 Před 4 lety

    Can I have the references for this presentation....which article have you taken ???

  • @ZainabFakhraMD
    @ZainabFakhraMD Před 9 měsíci

    does the L1 in the explanation correlate to depth and L2 width?

  • @CyberHo4X
    @CyberHo4X Před měsícem

    Unfortunately the fourier part and building layer for layer is missing.

  • @rooneymax9144
    @rooneymax9144 Před 4 lety

    Very good

  • @veronicanicholls7132
    @veronicanicholls7132 Před 6 lety

    Should high myopes have one every year

  • @deepakkrishnan2175
    @deepakkrishnan2175 Před 8 lety

    I have a doubt. Is it better to use light with high coherence length?

    • @bcsushi91
      @bcsushi91 Před 7 lety +1

      If it is high coherence length you don't get as much "spread" of the light and you won't see as much, but it would increase resolution

  • @idoctor-manjotkaur8574

    V helpful

  • @inventaunmanana4860
    @inventaunmanana4860 Před 5 lety

    i love you

  • @live4Cha
    @live4Cha Před 5 lety

    Come on!!! Its not mikelson interferometer its michael + son its michelson intrf...

  • @mandolinic
    @mandolinic Před 5 lety +1

    Painfully slow presentation. I recommend watching at 1.75x normal speed.

  • @sendafessi1733
    @sendafessi1733 Před 4 měsíci +1

    i love you