Video není dostupné.
Omlouváme se.

Mitutoyo Metrology Class: How to Measure Surface Roughness with the Surftest SJ-210

Sdílet
Vložit
  • čas přidán 13. 10. 2019
  • Surface roughness measurement can be tricky, learn how easy it is to do this with the portable Surftest SJ-210. Go to mitutoyo.eu/ to find out more about Mitutoyo’s surface roughness measuring instruments.
    CHECK OUT OUR RESOURCES
    Webshop: bit.ly/mitutoyo-shop
    Specified Tool: bit.ly/sj-210
    Latest Article: bit.ly/Emo2019
    Events: bit.ly/mitutoyo-events
    LIKE FREQUENT UPDATES?
    Linkedin: bit.ly/mitutoyo-Li
    Subscribe: bit.ly/mitutoyo-subscribe
    Previous Video: • Mitutoyo Metrology Cla...

Komentáře • 62

  • @ssaihtc8922
    @ssaihtc8922 Před 2 lety +1

    Thanks for sharing 😊

  • @esamlyful
    @esamlyful Před 4 lety +1

    Thanks, this is very nice tutorial

  • @AnangKatyayanrandomvideos

    nicely explained..

  • @krnika4047
    @krnika4047 Před 4 lety +2

    Very informative .......

  • @shawan5309
    @shawan5309 Před 3 lety

    Which model is more feasible for surface profile range from 3 to 5 Mills?

  • @s.janakiammamusicparadise6137

    Sir,iI have SJ 210 roughness but I need to check R max ..how to set ?Pls tell

  • @bishalthapa3874
    @bishalthapa3874 Před 4 lety +3

    very nicely explained ... even a non skilled person can understand about the device clearly . Great way of explaining. And really useful device.

  • @michaelgraber5750
    @michaelgraber5750 Před 6 měsíci

    How do you measure spherical surfaces, or corner radii?

  • @TheLuchyboy
    @TheLuchyboy Před 7 měsíci

    I have an SJ 3-10 and I’m getting an OVER RANGE warning on my display? Any advice?

  • @wowmoment2593
    @wowmoment2593 Před 4 lety

    Sir how we can make report can u explain.

  • @sagaringole3933
    @sagaringole3933 Před 7 měsíci

    Can we operate with PC and get measurements in soft form.

  • @mechtech1976
    @mechtech1976 Před 4 lety +1

    Please describe Ra,Rz like this

  • @waynet8327
    @waynet8327 Před 3 lety

    What the +/- range from the specimen standard before you press update after you calibrate? I have 115 micro inch standard and after reading it shows sometimes 114.2, 115.6 or 116. What is supposed to be the range before pressing update?

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety

      For detailed support on your particular device, please choose your country here and get in contact with your local support team: www.mitutoyo.co.jp/global.html

  • @thebinayak
    @thebinayak Před 2 lety +1

    Nice video, how can I get the users manual? Also my problem is that the stylus does not go back. Thank you

    • @MitutoyoEurope
      @MitutoyoEurope  Před 9 měsíci

      The user manual is usually delivered with the product. When this is not the case, please contact your local Mitutoyo office or dealer. You can find their contact information at www.mitutoyo.eu by changing the country at the top right corner.

  • @tatmiyajayesh1016
    @tatmiyajayesh1016 Před 3 lety

    Sj-410 calibration and after stylish change settings.

  • @sushmautnoori5596
    @sushmautnoori5596 Před 2 měsíci

    How can we calculate the Q value sir?

  • @rajnikantengg
    @rajnikantengg Před rokem

    how to conver measuring unit to microinch

  • @singhjadon8835
    @singhjadon8835 Před 2 lety

    Plz tell me least count of this instrument .

  • @punchole
    @punchole Před 6 měsíci +1

    I have drawing that mention Rmax, i can not get any references related to this value, cannot be convert to micron, can this tools measure the Rmax 5?

    • @MitutoyoEurope
      @MitutoyoEurope  Před 6 měsíci

      The parameter Rmax can be evaluated according to the VDA guideline or the ANSI or JIS standard.

  • @hayatiakgul8906
    @hayatiakgul8906 Před 3 lety

    please, how to choose λc on the user manual? can you explain it

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety

      Please refer to chapter 7.6 in your user manual for this function.

  • @a.t.s.tharindu2822
    @a.t.s.tharindu2822 Před 3 měsíci

    How do I know the range of Ra value? It is not given in the specifications.

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 měsíci

      The measurement conditions for Ra must be selected in accordance with EN ISO 4288.
      You can check it in our “Quick Guide to Surface Roughness Measurement”, downloadable via mitutoyo.eu/education/education-packs !

  • @segunoladunjoye2610
    @segunoladunjoye2610 Před 4 lety

    I tried to measure dent on a flange face and i get "over range". How can i solve this problem?

    • @MitutoyoEurope
      @MitutoyoEurope  Před 4 lety +1

      Dear Segun,
      The result exceeds the measuring range of 360 µm.
      Please check your user manual - you will find in the “troubleshooting section” information on how to solve your issue.

  • @GentiluomoStraniero
    @GentiluomoStraniero Před 10 měsíci +1

    Another cool gadget

  • @user-ui2qo2kf9h
    @user-ui2qo2kf9h Před 9 měsíci

    What is difference between- standard, retractable and traverse type ? also 0.75 or 4 mN ? how to diffrentiate and choose the right model ?

    • @MitutoyoEurope
      @MitutoyoEurope  Před 9 měsíci

      Hi! Thanks for your question. We have sent your questions to one of our specialists and here is his answer.
      The difference lies in the behavior of the detector.
      The standard model, called Surftest SJ-210, has a straight measuring direction.
      The transversal type can used to measure for example in a crankshaft by moving the detector in the transverse direction. This model is called Surftest SJ-210S.
      The retractable model can be placed at the measuring position so that it does not come into contact with the surface until the start button on the device is pressed. The detector then lowers onto the surface to be measured; this model is called Surftest SJ-210R.
      The difference between 0.75 mN and 4 mN meets the requirements of ISO standards.
      To select the correct code number, please visit your local Mitutoyo website by selecting your country of residence: mitutoyo.eu/

  • @ruthranpappusamy9514
    @ruthranpappusamy9514 Před 3 lety +1

    We tested the master (Ra 2.97) ,but we got only 0.015 micron .How to fix this problem or change any setting on that device.

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety +1

      Please check the correct steps for a stylus calibration in our user manual. You will find therein detail on how to set up the right values, measuring length, cut-off, and how to do a correct stylus calibration.
      In addition please check the stylus tip if anything is broken and the calibration reference specimen.

    • @ruthranpappusamy9514
      @ruthranpappusamy9514 Před 3 lety

      @@MitutoyoEurope kindly send the user manual.

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety

      @@ruthranpappusamy9514 Please contact your local Mitutoyo subsidiary for this - if you need assistance locating them, do not hesitate to ask.

  • @rajendradesitech1234
    @rajendradesitech1234 Před rokem

    Sj210 showing over range please rectify

    • @MitutoyoEurope
      @MitutoyoEurope  Před rokem

      @ Rajendra Desi Tech
      Please check the user manual chapter 16.2.
      Possibly causes:
      The result exceeds the measuring range.
      Solutions:
      Properly connect the detector to the drive unit.
      Refer to the user manual chapter 3.2.1 “attaching and detaching the detector”.
      When the measurement range has been fixed, set it to Auto.
      Refer to the user manual chapter 6.5.2 “modifying the measuring range”.

  • @muhammadazam339
    @muhammadazam339 Před 2 lety

    Hi, whenever I try to measure Ra using SJ 210, the detector does not move. Message on the display unit appears as " Returning?". What can go wrong? Tell the solution plz.

  • @valentinaterihaj8751
    @valentinaterihaj8751 Před 2 lety

    What "returning" erorr means? 😶

  • @mohsinmohsin-kt4tj
    @mohsinmohsin-kt4tj Před 3 lety

    salut
    j'ai un code d'erreur = erreur de limite sur l'écran du mon surftest SJ-210???

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety

      Please contact your local Mitutoyo subsidiary for this! You can use the link below to access our Mitutoyo's global portal:
      www.mitutoyo.co.jp/global.html

  • @Arunkumar123973
    @Arunkumar123973 Před 2 lety

    surface tester is not showing date row in red colour if stylus not measuring

  • @dianfadli7825
    @dianfadli7825 Před rokem

    Dear sir, thanks for tutorial
    I already start but indicator in screen "RETURNING"
    Please give me solver
    Thanks

    • @MitutoyoEurope
      @MitutoyoEurope  Před rokem

      Dear Dian,
      I am sorry, can you please give some more detail?
      What exactly is happening?
      At which point during the measurement process does this happen?

    • @dianfadli7825
      @dianfadli7825 Před rokem +1

      @@MitutoyoEurope already finish sir, jack connector not 100 % push

  • @MohdSalman-rg2bu
    @MohdSalman-rg2bu Před 3 lety

    Please tell me about lamda c what is this???

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety

      Dear Mohd Salman,
      The roughness profile (R-profile) is the profile resulting from electronic high-pass filtering of the primary profile with a cut-off wavelength λc. This process removes the longer wavelength components. The parameters are designated R and evaluated within the evaluation length ln, which generally consist of five sampling lengths lr. The sampling length corresponds to the cut-off wavelength λc of the profile filter. You can get all details for example in the ISO 4287, ISO 4288, ISO 3274.

    • @MohdSalman-rg2bu
      @MohdSalman-rg2bu Před 3 lety

      @@MitutoyoEurope thnxxx sir

  • @unexpectmoments1285
    @unexpectmoments1285 Před 3 lety

    How to check number of deavition

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety

      For detailed support on your particular device, please choose your country here and get in contact with your local support team: www.mitutoyo.co.jp/global.html

  • @RahulSharma-pj2js
    @RahulSharma-pj2js Před 3 lety

    How to switch off this device

    • @MitutoyoEurope
      @MitutoyoEurope  Před 3 lety

      Dear Rahil Sharma, please press the [POWER/DATA] key to turn off the power.

  • @ganeshdahatonde7650
    @ganeshdahatonde7650 Před 4 lety

    Sir, what is the accuracy of instrument....

  • @jamesmax7126
    @jamesmax7126 Před 2 lety

    Anda boleh memilih untuk salah satu daripada hadiah di atas

  • @ROYSUMIT1
    @ROYSUMIT1 Před 4 lety

    @5:53 description